27.12.2012 Views

1/2006 - Potravinárstvo

1/2006 - Potravinárstvo

1/2006 - Potravinárstvo

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TOKUSOGLU, O., UNAL, M. K. 2003. Biomass Nutrient<br />

Profiles of Three Microalgae: Spirulina platensis, Chlorella<br />

vulgaris and Isochrisis galbana. J. Food Sci., 68, 2003, p.<br />

1144–1148.<br />

TSUI, M. T. K., CHEUNG, K. C., TAM, N. F. Y., WONG,<br />

M. H. <strong>2006</strong>. A comparative study on metal sorption by brown<br />

seaweed. Chemosphere, 65, <strong>2006</strong>, p. 51–56.<br />

VASCONCELOS, M. T. S. D., LEAL, M. F. C. 2001.<br />

Seasonal variability in the kinetics of Cu, Pb, Cd and Hg<br />

accumulation by macroalgae. Mar. Chem., 74, 2001, p. 65–<br />

85.<br />

VILLARES, R., PUENTE, X., CARBALLEIRA, A. 2002.<br />

Seasonal variation and background levels of heavy metals in<br />

two green seaweeds. Environ. Pollut., 119, 2002, p. 79–90.<br />

VIOLA, R., NYVALL, P., PEDERSÉN, M. 2001. The<br />

unique features of starch metabolism in red algae. Proc. R.<br />

Soc. Lond. B, 268, 2001, p. 1417–1422.<br />

ÚVOD<br />

Blízká infračervená spektrometrie (NIR) využívá část<br />

elektromagnetického spektra mezi viditelným zářením a<br />

infračerveným spektrem (800-2500 nm). Umožňuje získat<br />

informace o relativním obsahu a poměru C-H, O-H a N-H<br />

vazeb, které tvoří organickou matrix všech potravin. NIR<br />

spektrometrie je úspěšně využívána v průmyslu pro<br />

chemickou analýzu díky množství výhod jako rychlá a<br />

přesná metoda. V mlékařství se spektrometrie<br />

v infračervené oblasti používá pro stanovení laktózy,<br />

proteinů, obsahu tuku v mléce a dalších parametrů mléka<br />

(Díaz-Carrillo et al., 1993; Albanell et al, 1999; Laporte<br />

a Paquin, 1999; Čurda et al., 2002; Jankovská a<br />

Šustová, 2003;), sýrů (Rodriquez-Otero et al., 1995;<br />

Sorensen a Jepsen, 1998a, b; Wittrup a Norgaard,<br />

1998) a ostaních mléčných výrobků (Rodriquez-Otero a<br />

<strong>Potravinárstvo</strong><br />

WONG, K. H., CHEUNG, P. C. K. 2001. Nutritional<br />

evaluation of some subtropical red and green seaweeds. Part<br />

II. In vitro protein digestibility and amino acid profiles of<br />

protein concentrates. Food Chem., 72, 2001, p. 11–17.<br />

YE, H., WANG, K., ZHOU, CH., LIU, J., ZENG, X. 2008.<br />

Purification, antitumor and antioxidant activities in vitro of<br />

polysaccharides from the brown seaweed A. Food Chemistry.<br />

111, 2008, p. 428–432.<br />

Poděkování:<br />

Práce vznikla za podpory projektu MŠMT: MSM<br />

7088352101<br />

Kontaktní adresa:<br />

Ing. Ladislava Mišurcová, Ph.D., Ústav technologie<br />

a mikrobiologie potravin, Fakulta technologická, Univerzita<br />

Tomáše Bati ve Zlíně, náměstí T. G. Masaryka 275, 762 72<br />

Zlín, Tel: 00420 576 031 201, email: misurcova@ft.utb.cz<br />

VYUŽITÍ BLÍZKÉ INFRAČERVENÉ SPEKTROSKOPIE PRO STANOVENÍ<br />

ZÁKLADNÍCH FYZIKÁLNĚ-CHEMICKÝCH PARAMETRŮ OVČÍHO MLÉKA<br />

APPLICATION OF NEAR INFRARED SPECTROSCOPY TO DETERMINE THE<br />

BASIC CHEMICAL AND PHYSICAL PARAMETERS OF SHEEP MILK<br />

Zuzana Procházková, Michaela Dračková, Alena Remešová, Bohumíra Janštová,<br />

Hana Přidalová, Lenka Vorlová<br />

ABSTRACT<br />

Proteins, lactose, total solids, solids-non-fat and titratable acidity were analyzed from sheep milk without any previous<br />

sample treatment. The spectra were measured in the transflectance mode (0.1 mm path-length) in near infrared region<br />

10 000 – 4 000 cm -1 , with an average of 100 scans. A set of 33 samples was used to calibrate the instrument by partial least<br />

squares regression method (PLS) and checked later with cross validation on the same set of samples. The following<br />

statistical results were obtained: correlation coefficient (R) of 0.966 and standard error of calibration (SEC) 0.328 for<br />

proteins, R = 0.999 and SEC = 0.027 for lactose, R = 0.968 and SEC = 0.684 for total solids, R = 0.951 and SEC = 0.237<br />

for solids-non-fat, R = 0.949 and 0.312 for titratable acidity, respectively. All the parameters of calibration set as obtained<br />

by FT-NIR spectroscopy were compared with those obtained by the reference methods, linear regression and paired t-test<br />

and no significant results were obtained at statistical level P

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!