CamSep 4 2

31.03.2017 Views

Uniwersytet Przyrodniczo‐Humanistyczny w Siedlcach<br />

Instytut Chemii<br />

Camera Separatoria<br />

Volume 4, Number 2 / December 2012<br />

Siedlce 2012


Editors (reviewers):<br />

Tadeusz Dzido – Lublin, Bronisław K. Głód – Siedlce, Marian Kamiński – Gdańsk,<br />

Piotr M. Słomkiewicz – Kielce, Piotr Stepnowski – Gdańsk, Andrzej Stołyhwo –<br />

Warszawa, Monika E. Waksmundzka-Hajnos – Lublin, Paweł K. Zarzycki – Koszalin<br />

Co-Editors-in-Chief:<br />

Bronisław K. Głód (Siedlce) and Marian Kamiński (Gdańsk)<br />

Technical Editors:<br />

Paweł Piszcz, Paweł M. Wantusiak<br />

URL: http://dach.ich.uph.edu.pl/pl/_cs.html<br />

Adres Redakcji / Editorial office’s address:<br />

Zakład Chemii Analitycznej, Instytut Chemii<br />

Uniwersytet Przyrodniczo-Humanistyczny w Siedlcach<br />

ul. 3 Maja 54, 08-110 Siedlce<br />

tel. (25) 64310 41<br />

e-mail: psc1@onet.eu<br />

Publishing House<br />

Siedlce University of Natural Sciences and Humanities<br />

08-110 Siedlce, ul. Bema 1<br />

phone: 48 25 643 15 20<br />

e-mail: wydawnictwo@uph.edu.pl<br />

www.wydawnictwo.uph.edu.pl


SPIS TREŚCI<br />

(CONTENTS)<br />

Bronisław K. Głód, Iwona Kiersztyn, Anna Lamert, Monika Skwarek,<br />

Paweł Wantusiak, Paweł Piszcz<br />

4-te Podlaskie Spotkania Chromatograficzne ............................................ 107<br />

Prace oryginalne / Original papers<br />

Grażyna Gałęzowska, Joanna Podwysocka, Marian Kamiński<br />

Badania nad możliwościa wykorzystania chromatografii wykluczania<br />

do indentyfikacji i oznaczania modyfikatorów w masie bitumicznej i<br />

nawierzchni asfaltowej ............................................................................... 113<br />

Grzegorz Boczkaj, Mariusz Jaszczołt, Marian Kamiński<br />

Demulgowanie jako efektywna technika rozdzielania stosowana w<br />

procesach oczyszczania ścieków przemysłowych ..................................... 123<br />

Prace przeglądowe / Review papers<br />

Piotr Lisowski, Paweł K. Zarzycki<br />

Badania nad mikroprzepływowymi urządzeniami analitycznymi na bazie<br />

papieru ( PADs) - przegład literatury ......................................................... 135<br />

Pozostałe / Other<br />

Bronisław K. Głod<br />

Jeden, dwa, trzy …… Podlaskie Spotkania Chromatograficzne czyli krótka<br />

historia Podlaskich Spotkań Chromatograficznych .................................... 151<br />

Instrukcje dla autorów ................................................................................. 172<br />

Instructions for Authors and Editorial Policy ............................................... 176


CAMERA SEPARATORIA<br />

Volume 4, Number 2 / December 2012, 107-111<br />

Bronisław K. GŁÓD, Iwona KIERSZTYN, Anna LAMERT,<br />

Monika SKWAREK, Paweł M. WANTUSIAK, Paweł PISZCZ<br />

Zakład Chemii Analitycznej, Instytut Chemii, Wydział Nauk Ścisłych,<br />

Uniwersytet Przyrodniczo-Humanistyczny w Siedlcach,<br />

ul. 3 Maja 54, 08-110 Siedlce<br />

e-mail: bkg@onet.eu; URL: http://dach.ich.uph.edu.pl<br />

4-te Podlaskie Spotkanie Chromatograficzne<br />

4 th Podlasie’s Chromatographic Meeting<br />

W dniach 23-26 września 2012 r. odbyło się IV Podlaskie Spotkanie<br />

Chromatograficzne w dworku Reymontówka w Chlewiskach. Zorganizowane<br />

zostało pod opieką Komitetu Naukowego (Tadeusz Dzido – Lublin;<br />

Bronisław K. Głód – Siedlce; Marian Kamiński – Gdańsk; Piotr Słomkiewicz<br />

– Kielce; Piotr Stepnowski – Gdańsk; Andrzej Stołyhwo – Warszawa;<br />

Monika E. Waksmundzka-Hajnos – Lublin; Paweł Zarzycki – Koszalin) oraz<br />

przez Komitet Organizacyjny w składzie Bronisław K. Głód; Iwona Kiersztyn;<br />

Anna Lamert; Monika Skwarek, Paweł Piszcz i Paweł Wantusiak.<br />

W niedzielny wieczór, 23 września konferencję zainaugurował bankiet<br />

powitalny, podczas którego tradycyjnie został zaprezentowany młody<br />

siedlecki talent muzyczny. Tym razem była to 10 letnia, śpiewająca<br />

stypendystka Prezydenta Miasta Siedlce, Anita Radzikowska. Wieczorne<br />

biesiadowanie umilił, jak co roku fortepianowy koncert pani profesor Moniki<br />

Waksmundzkiej.<br />

Kolejny dzień to wykłady i bardzo bogata sesja posterowa. Popołudniowe<br />

dyskusje moderowane były przez panie Monikę Asztemborską i Iwonę<br />

Kiersztyn oraz panów profesorów Pawła Zarzyckiego i Piotra Słomkiewicza.<br />

Dyskusje naukowe przedłużyły się do późnych godzin wieczornych.<br />

Wtorkowy program zachęcił wszystkich do bardzo wczesnej pobudki. Już o<br />

siódmej rano wyruszyliśmy na wycieczkę do Białowieży (patrz załączone<br />

zdjęcia). Pogoda i nastroje dopisywały wszystkim. Na spacer po Puszczy<br />

Białowieskiej podzieliliśmy się na dwie grupy, aby w tempie spacerowym i<br />

sprinterskim podziwiać uroki natury. Przed zwiedzaniem rezerwatu żubrów<br />

posililiśmy się wyśmienitymi żeberkami i po zakupieniu pamiątek ruszyliśmy


108 B.K. Głód, I. Kiersztyn, A. Lamert, M. Skwarek, P.M. Wantusiak, P. Piszcz<br />

w drogę powrotną. Dzień zakończyliśmy wspólnym biesiadowaniem przy<br />

ognisku, podczas którego została wręczona nagroda za najlepszy poster<br />

(album ze zdjęciami z poprzednich Spotkań) pani mgr Magdalenie<br />

Cerkowniak z Zakładu Analizy Środowiska Uniwersytetu Gdańskiego.<br />

W środę rano zakończyliśmy IV Podlaskie Spotkanie Chromatograficzne,<br />

które niewątpliwie zaliczyliśmy do udanych.<br />

Camera Separatoria Vol. 4, No 2/2012


4-te Podlaskie Spotkanie Chromatograficzne 109<br />

Camera Separatoria Vol. 4, No 2/2012


110 B.K. Głód, I. Kiersztyn, A. Lamert, M. Skwarek, P.M. Wantusiak, P. Piszcz<br />

Camera Separatoria Vol. 4, No 2/2012


4-te Podlaskie Spotkanie Chromatograficzne 111<br />

Camera Separatoria Vol. 4, No 2/2012


Camera Separatoria<br />

PRACE ORYGINALNE<br />

(ORIGINAL PAPERS)


CAMERA SEPARATORIA<br />

Volume 4, Number 2 / December 2012, 113-122<br />

Grażyna GAŁĘZOWSKA 2 , Joanna PODWYSOCKA 1 , Marian KAMIŃSKI 1<br />

1<br />

Politechnika Gdańska, Wydział Chemiczny, Katedra Technologii Chemicznej,<br />

ul. G. Narutowicza 11/12, 80-952 Gdańsk,<br />

e-mail: mknkj@chem.pg.gda.pl<br />

2<br />

Gdański Uniwersytet Medyczny, Wydział Nauk o Zdrowiu z oddziałem Pielęgniarstwa<br />

i Instytutem Medycyny Morskiej i Tropikalnej, Zakład Toksykologii Środowisk,<br />

ul. Powstania Styczniowego 9b, 81-519 Gdynia,<br />

e-mail: grazynagalezowska@gumed.edu.pl<br />

Badania nad możliwością wykorzystania chromatografii<br />

wykluczania do identyfikacji i oznaczania modyfikatorów<br />

w masie bitumicznej i nawierzchni asfaltowej<br />

Streszczenie: Zapotrzebowanie na asfalty modyfikowane wzrasta ze względu na szybkie<br />

tempo rozwoju infrastruktury w kraju. Konieczne jest, więc opracowanie obiektywnego<br />

parametru określającego zawartość modyfikatora w masie bitumicznej, czy nawierzchni<br />

asfaltowej. W aktualnej normie PN EN 14023, dotyczącej zasad klasyfikacji asfaltów<br />

modyfikowanych polimerami, oznaczanie zawartości modyfikatora nie jest parametrem<br />

wymaganym. Masa bitumiczna modyfikowana jest droższa o około 20-25% od materiałów<br />

„klasycznych”. W związku z tym, istnieje prawdopodobieństwo stosowania modyfikatorów w<br />

niższej od wymaganej ilości do tworzenia nawierzchni drogowych. Stąd ważna jest umiejętność<br />

oznaczania zawartości modyfikatora w lepiszczu zastosowanym do wykonania mieszanki<br />

bitumiczno mineralnej oraz w nawierzchni drogi. W pracy przedstawiono przydatność techniki<br />

chromatografii wykluczania do rozdzielania modyfikatora od masy bitumicznej oraz oznaczenia<br />

zawartości modyfikatorów polimerowych w masach bitumicznych i asfaltach. Do badań wybrano<br />

dwa najpowszechniej stosowane modyfikatory asfaltów drogowych - kopolimer styrenbutadien-<br />

styren (SBS) i styren- butadien (SB). Badano asfalty modyfikowane i<br />

niemodyfikowane oraz mieszanki mineralno - asfaltowe pobrane z różnych ulic Gdańska.<br />

Słowa kluczowe: asfalt drogowy, modyfikatory asfaltu, styren-butadien - SB, styren-butadienstyren<br />

- SBS, chromatografia wykluczania – GPC-SEC<br />

Determination of polymer modifiers in bitumen and road<br />

asphalt by size exclusion chromatography<br />

Abstract: Demand for modified asphalt road increases due to fast development of the<br />

infrastructure. Therefore it is necessary to elaborate a reliable parameter which would indicate<br />

the modifier content in a given asphalt sample. The currently used standard PN EN 14023,<br />

which spells out the rules of classification for polymer modified asphalts, does not require the<br />

determination of the content of a modifier in bitumen and in road pavement. Modified asphalts<br />

are about 20 to 25% more expensive as compared to traditional asphalts. Such cost difference<br />

creates a very likely scenario of tampering with the pavement composition by lowering the<br />

required content of modified asphalt. In this study we describe the application of High<br />

Performance Size Exclusion Chromatography for separation of modifier and bitumen with the<br />

determining of the content of polymer modifiers of the content of a modifier in bitumen and in<br />

road pavement. Two most commonly used modifiers of paving asphalts, namely, styrenebutadiene-styrene<br />

(SBS) and styrene-butadiene (SB) copolymers as well as modified asphalts,<br />

non-modified asphalts and the mixtures of asphalt and mineral aggregates sampled from<br />

various streets in the city of Gdansk were investigated.<br />

Key words: polymer modifiers, styrene-butadiene (SB), styrene-butadiene-styrene (SBS), road<br />

asphalts, bitumen, size exclusion chromatography


114 G. Gałęzowska, J. Podwysocka, M. Kamiński<br />

1. Wstęp<br />

(Introduction)<br />

Asfalty to materiały należące do grupy tworzyw termoplastycznych<br />

i lepkosprężystych. Ogrzewane miękną przechodząc stopniowo<br />

z konsystencji stałej do ciekłej, natomiast pod wpływem oziębiania w stan<br />

sprężysty, kruchy. W pośrednich warunkach temperaturowych asfalty<br />

wykazują właściwości zarówno cieczy lepkiej, jak również sprężystego ciała<br />

stałego. Właściwości asfaltu, mieszanki mineralno-asfaltowej oraz<br />

nawierzchni ulegają zmianom w funkcji temperatury i czasu trwania<br />

obciążenia. Ważne jest więc by zakres lepkosprężystości asfaltu był na tyle<br />

szeroki, aby w temperaturach osiąganych w czasie eksploatacji obiektu, nie<br />

zmieniał swojego stanu reologicznego. Celem modyfikacji asfaltu jest<br />

poprawa własności użytkowych mieszanek mineralno- asfaltowych oraz<br />

wydłużenie czasu eksploatacji nawierzchni drogowej. Wymaga to<br />

zwiększenia odporności nawierzchni na odkształcenia trwałe, pękanie,<br />

starzenie, zmęczenie, czy oddziaływanie czynników zewnętrznych. Metody<br />

poprawy właściwości mieszanek mineralno- asfaltowych, polegające na<br />

zwiększeniu kąta tarcia wewnętrznego mieszanki (zwiększenie udziału<br />

ziaren łamanych oraz frakcji grysowej) oraz optymalizacji zawartości<br />

i konsystencji lepiszcza nie są w stanie zapewnić nawierzchni wszystkich<br />

wymaganych właściwości, szczególnie w warunkach rosnącego obciążenia<br />

ruchem samochodowym [1].<br />

Polska, jak wiele krajów, leży w klimacie niezbyt przyjaznym dla<br />

nawierzchni drogowych. Tradycyjne (konwencjonalne) asfalty nie są w<br />

stanie spełnić wszystkich wymagań użytkowników dróg. Uciążliwe dla<br />

kierowców są koleiny powstające w upalne lato wywołane przez powoli<br />

jadące samochody ciężarowe oraz spękania poprzeczne wywołane przez<br />

szybkie spadki temperatury w zimie. Jedną z najszerzej znanych na świecie<br />

metod przeciwdziałania powyższym zjawiskom jest zastąpienie<br />

konwencjonalnego asfaltu – polimeroasfaltem.<br />

Polimeroasfalt to asfalt drogowy zawierający określoną ilość<br />

modyfikatora w postaci polimeru, który został wprowadzony podczas<br />

procesu technologicznego zwanego modyfikacją [2]. W wyniku modyfikacji<br />

następuje połączenie polimeru i asfaltu. W konsekwencji, otrzymujemy<br />

produkt o właściwościach, które zwiększają odporność nawierzchni, na<br />

koleinowanie i pękanie. Zastosowanie polimeroasfaltów to głównie, jako<br />

nawierzchnia dróg obciążonych dużym i ciężkim ruchem, mostów, rond,<br />

skrzyżowań. Wraz z wprowadzaniem poliemroasfaltów wzrosła konieczność<br />

oznaczania modyfikatorów asfaltowych. Jest to jedno ze współczesnych<br />

zadań analitycznych dotyczących oznaczania składników skomplikowanych<br />

mieszanin. W takich przypadkach nieocenione są techniki chromatografii,<br />

a gdy zadanie dotyczy składników niskolotnych, bądź nielotnych – techniki<br />

chromatografii cieczowej. Stosowanie techniki chromatografii cieczowej<br />

jest szczególnie korzystne w przypadku oznaczania składu grupowego<br />

Camera Separatoria Vol. 4, No 2/2012


Badania nad możliwością wykorzystania chromatografii wykluczania...<br />

115<br />

asfaltów [3]. Również w przypadku oznaczania modyfikatorów zastosowanie<br />

techniki chromatografii cieczowej wydaje się być celowe.<br />

Do tej pory opracowano procedurę oznaczania kopolimeru styren–<br />

butadien- styren (SBS), kauczuku butadienowo-styrenowego (SBR) oraz<br />

styrenu-butadienu (SB) z zastosowaniem techniki spektroskopii w<br />

podczerwieni (FTIR) [4]. Dodatkowo w literaturze istnieją doniesienia o<br />

możliwości wykorzystania chromatografii wykluczania (GPC/SEC) w tego<br />

typu analizach [5]. Jest to spowodowane wysokimi masami molekularnymi<br />

stosowanych polimerów. Technika chromatografii cienkowarstwowej z<br />

detektorem płomieniowo-jonizacyjnym wydaje się być również przydatna do<br />

oznaczania modyfikatorów, jednak jej podstawowe zastosowanie to<br />

oznaczanie składu grupowego. Obecnie w normie PN EN 14023 [6],<br />

dotyczącej zasad klasyfikacji asfaltów modyfikowanych polimerami,<br />

oznaczanie zawartości modyfikatora nie jest parametrem wymaganym.<br />

Asfalty modyfikowane są droższe o około 20-25% od asfaltów „klasycznych”.<br />

W związku z tym istnieje prawdopodobieństwo fałszowania asfaltów<br />

modyfikowanych poprzez stosowanie ich w niższej od wymaganej ilości do<br />

tworzenia nawierzchni drogowych. Tym bardziej, że ilość zastosowanych<br />

modyfikatorów nie podlega kontroli.<br />

W związku z powyższym celowe było opracowanie procedury<br />

rozdzielania i w konsekwencji oznaczania modyfikatorów w asfaltach.<br />

Opracowana metodyka powinna znaleźć zastosowanie w laboratorium<br />

kontroli jakości, a także w analityce procesowej. Rezultaty i wnioski z badań<br />

powinny mieć także znaczenie dla identyfikacji zafałszowania w/w<br />

produktów.<br />

2. Część eksperymentalna<br />

(Experimental)<br />

2.1. Materiały<br />

(Materials)<br />

Tabela 1. Zestawienie stosowanych kolumn chromatograficznych<br />

Table 1. List of chromatographic columns<br />

Nazwa Parametry kolumny Producent<br />

LiChrogel PS1- dwie<br />

5 µm, 250 x 7 mm Merck (Niemcy)<br />

LiChrogel PSmix - dwie 5 µm, 250 x 7 mm Merck (Niemcy)<br />

Tabela 2. Zestawienie stosowanych rozpuszczalników i eluentów<br />

Table 2. List of solvents<br />

Nazwa Stopień czystości Producent<br />

tetrahydrofuran do HPLC Merck (Niemcy)<br />

dichlorometan cz. d. a. POCH (Polska)<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


116 G. Gałęzowska, J. Podwysocka, M. Kamiński<br />

Tabela 3. Zestawienie stosowanych substancji wzorcowych<br />

Table 3. List of standards<br />

Substancja wzorcowań<br />

Producent<br />

Polistyreny o masach:<br />

Merck (Niemcy)<br />

1) 1260000 Da, 2) 120000 Da, 3) 30300 Da,<br />

4) 2450 Da 5) benzen<br />

SBS<br />

Joss Group (Holandia)<br />

SB<br />

Minova Ekochem S.A. (Polska)<br />

2.2. Aparatura<br />

(Equipment)<br />

Gradientowy chromatograf cieczowy LaChrom Merck-Hitachi<br />

(Niemcy) wyposażony w czterokanałowy system do elucji gradientowej z<br />

zaworami proporcjonującymi (tzw. gradient niskociśnieniowy), pompę L-<br />

6200, zawór dozujący Rheodyne Rh-7725i z pętlą dozującą 50 μl, kolumnę<br />

chromatograficzną, termostat, detektor UV/DAD 7450A, detektor<br />

refraktometryczny RI, oprogramowanie HSM.<br />

Waga analityczna RADWAG (Polska).<br />

Łaźnia ultradźwiękowa model XL – 2020 Sonificator® Misonix (USA).<br />

Wyparka obrotowa Heidolph ( Niemcy).<br />

Asfalty niemodyfikowane o penetracji: 35/50, 160/220, asfalty<br />

modyfikowane: 25/55-60, 45/80-55, wyprodukowane w Grupie LOTOS S.A.<br />

Polska. Do badań zostały pobrane również próbki asfaltów wbudowanych<br />

w różnym okresie, z ulic Gdańska oznaczonych kolejno 1(2008), 2(2007),<br />

3(2006). Daty oznaczają terminy oddania asfaltu do użytkowania.<br />

2.3. Przygotowanie próbek do analizy<br />

(Samples preparation)<br />

Na terenie Gdańska pobrano 3 próbki nawierzchni asfaltowych<br />

modyfikowanych i niemodyfikowanych, z różnego okresu budowy dróg.<br />

Próbki zostały pobrane na głębokość 1 cm (szerokości ok. 1 cm). Kolejno,<br />

materiały zostały rozdrobnione, następnie przeniesione do wytarowanych<br />

fiolek 10 ml i poddane ługowaniu/ekstrakcji dichlorometanem z<br />

zastosowaniem techniki ekstrakcji za pomocą rozpuszczalnika<br />

wspomaganej ultradźwiękami (ok.10 minut). Zawartość fiolek była ługowana<br />

do chwili, gdy kruszywo było czyste, a całość odmytego asfaltu była w<br />

widoczny sposób rozpuszczona. Nierozpuszczony materiał został<br />

oddzielony za pomocą filtracji próżniowej, stosując miękki filtr o średnicy 90<br />

mm, który został przepłukany kilkukrotnie dichlorometanem. Filtrat został<br />

przeniesiony ilościowo do wytarowanych kolb okrogłodennych 100 ml.<br />

Zawartość kolby odparowano do sucha z zastosowaniem wyparki obrotowej<br />

w temperaturze 40˚C. Kolbki suszono w suszarce 30 minut w temperaturze<br />

120˚C w celu całkowitego wysuszenia.<br />

Camera Separatoria Vol. 4, No 2/2012


Badania nad możliwością wykorzystania chromatografii wykluczania...<br />

117<br />

Podczas rozdzielania składników mas bitumicznych i nawierzchni<br />

asfaltowych zastosowano cztery kolumny połączone szeregowo: dwie typu<br />

PS1 oraz dwie typu PS MIX, tetrahydrofuran, jako eluent (1 ml/min), oraz<br />

szeregowo połączone detektory: refraktometryczny i UV-VIS typu DAD.<br />

Rozdzielaniu w warunkach wykluczania poddano roztwory próbek w<br />

tetrahydrofuranie o stężeniu 50 mg/ml oraz pojedynczych modyfikatorów o<br />

stężeniu 5 mg/ml. Przygotowane roztwory przed wprowadzeniem do<br />

kolumny zostały przefiltrowane przez filtr teflonowy (PTFE) o średnicy porów<br />

0,45 µm. Wszystkie roztwory poddano rozdzielaniu w temperaturze 20˚C. Do<br />

wyznaczenia masy cząsteczkowej badanego polimeru wykonano kalibrację<br />

w odniesieniu do polistyrenu, czyli wykorzystano nisko – dyspersyjne<br />

standardy polistyrenu od najwyższej do najniższej masy molekularnej:<br />

1260000 Da, 120000 Da, 30300 Da, 2450 Da, benzen.<br />

Dodatkowo kalibrację dla obu modyfikatorów w masach bitumicznych<br />

dla roztworów o wzrastającej zawartości modyfikatora: materiał odniesienia<br />

zawierający 1% SBS, 3% SBS, 5% SBS, 7% SBS o stężeniach 50 mg/ml<br />

THF.<br />

2.4. Obliczenia statystyczne<br />

(Statistical calculations)<br />

Opracowanie statystyczne wyników badań dokonano w oparci o<br />

narzędzia dostępne w programie Microsoft Excel w pakiecie Analiza<br />

Danych. Obliczono wartość średnią, odchylenie standardowe (SD),<br />

względne odchylenie standardowe (RSD), powtarzalność oraz parametry<br />

opisujące regresję, tj. wartości współczynnika nachylenia i współczynniki<br />

korelacji. Wartości podawane są wartościami średnimi z pięciu pomiarów.<br />

3. Wyniki i dyskusja<br />

(Results and discussion)<br />

Rozdzielanie modyfikatorów od składników asfaltów odbyło się<br />

z wykorzystaniem chromatografii wykluczania. Oznaczenie dodatków<br />

zostało wykonane z wykorzystaniem metody krzywej kalibracyjnej, na<br />

podstawie czterech roztworów asfaltu o penetracji 35/50 o rosnącej<br />

zawartości polimeru (1%, 3%, 5%, 7%; R 2 = 0,9884).<br />

Dodatkowo, na podstawie krzywej kalibracyjnej stworzonej<br />

z wykorzystaniem analiz chromatograficznych dla wzorców polistyrenów o<br />

różnych masach oraz benzenu, wyznaczono masę cząsteczkową<br />

modyfikatora, która wynosi ok. 562341 Da. Należy podkreślić, że nie jest to<br />

rzeczywista masa cząsteczkowa badanego polimeru, a tylko jego<br />

odniesienie (miara) względem masy cząsteczkowej polistyrenu.<br />

Na rysunku 1 przedstawione zostały przykłady chromatogramów<br />

rozdzielania składników wybranych próbek masy bitumicznej modyfikowanej<br />

i niemodyfikowanej, a na rysunku 2 przedstawiono przykłady<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


118 G. Gałęzowska, J. Podwysocka, M. Kamiński<br />

chromatogramów rozdzielania modyfikatorów SB i SBS wykorzystywanych<br />

do otrzymywania nawierzchni asfaltowych modyfikowanych.<br />

Rys. 1. Chromatogramy detektora refraktometrycznego RI (większe) oraz<br />

spektrofotometrycznego UV-VIS (mniejsze) uzyskane z rozdzielania asfaltów; a- masa<br />

bitumiczna 25/55-60; b- masa bitumiczna niemodyfikowana 35/50; c- masa bitumiczna<br />

niemodyfikowany 160/220; Stężenie każdego z roztworów to 50 mg/ml; eluent THF,<br />

natężenie przepływu 1ml/min; objętość próbki 20μl; temperatura 20 0 C; 2 kolumny PS1 i<br />

2 kolumny PS mix (250-7 mm, 5 µm)<br />

Fig. 1. The GPC/SEC chromatograms; columns: 2xPS1+2xPS MIX, eluent: tetrahydrofuran 1<br />

mL/min, 20 µL injection volume, temerature 200C, a- modified bitumen 25/55-60; b- non<br />

modified bitumen 35/50; c- non modified bitumen 160/220<br />

Camera Separatoria Vol. 4, No 2/2012


Badania nad możliwością wykorzystania chromatografii wykluczania...<br />

119<br />

a<br />

b<br />

Rys. 2. Chromatogramy uzyskane z rozdzielania: a- SBS o stężeniu 5 mg/ml; b- SB o stężeniu<br />

5,3 mg/ml; eluent THF, natężenie przepływu 1ml/min; objętość próbki 20 ul;<br />

temperatura 20 0 C; 2 kolumny PS1 i 2 kolumny PS mix (250-7 mm, 5 µm)<br />

Fig. 2. The GPC/SEC chromatograms; columns: 2xPS1+2xPSmix, eluent: tetrahydrofuran,<br />

1 mL/min, 20 µL injection volume, temperature 20 0 C; a- SBS; b- SB<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


120 G. Gałęzowska, J. Podwysocka, M. Kamiński<br />

W przypadku masy bitumicznej i nawierzchni asfaltowej<br />

modyfikowanych w stosunku do próbek niemodyfikowanych na<br />

chromatogramach możemy zaobserwować dodatkowy pik modyfikatora,<br />

około 16 minuty (rys. 1a). Posiada on niższą retencje ze względu na wysoka<br />

masę molekularną (powyżej Da 562341, rys. 2.).<br />

Opracowana procedura może być z powodzeniem wykorzystywana do<br />

oznaczania zawartości modyfikatorów w masie bitumicznej i nawierzchni<br />

asfaltowej. W wyniku niewielkich różnic mas molekularnych SBSu i SB<br />

technika chromatografii wykluczania jest niewystarczająca do rozróżnienia<br />

obu modyfikatorów, nie jest to jednak koniczne.<br />

Rozdzielenie modyfikatorów od pozostałych składników próbek<br />

wymaga zastosowania aż cztery kolumny do chromatografii wykluczania<br />

(dwie PS1 i dwie PS mix), a zastosowanie detektora UV typu DAD nie<br />

wniosło żadnych dodatkowych informacji na temat modyfikatorów<br />

polimerowych.<br />

W celu integracji pików odzwierciedlających modyfikatory<br />

zastosowano metodę tzw. „kropli”. Z całą pewności wpływa to na<br />

zwiększenie poziomu błędu wyznaczania zawartości modyfikatorów w masie<br />

bitumicznej czy nawierzchni asfaltowej. Rozwiązaniem byłoby zastosowanie<br />

dekonwolucji, jednak jest to niemożliwe ze względu, iż zastosowywanie<br />

detektora UV-DAD nie umożliwi oznaczania modyfikatorów (brak absorpcji w<br />

całym zakresie pomiarowym.<br />

W przypadku rozdzielania modyfikowanych nawierzchni asfaltowych i<br />

masy bitumicznej z wykorzystaniem hydrofobowej fazy stacjonarnej, na<br />

etapie przygotowanie próbki należało odwodnić próbki. Zastosowano<br />

suszenie w 120°C. Jako alternatywa można użyć substancji suszących –<br />

bezwodne siarczany lub dodać żelu krzemionkowego, który stanowiłby fazę,<br />

na której zaadsorbowałaby się woda. Niestety, w powyższych przypadkach<br />

wiązałoby się z wprowadzeniem dodatkowego etapu, oddzielania fazy<br />

suszącej od próbki, co może powodować utratę analitów.<br />

Wykorzystując opracowaną procedurę rozdzielania wyznaczono<br />

zawartości modyfikatorów w nawierzchniach asfaltowych, które<br />

przedstawiono w tabeli 4.<br />

Camera Separatoria Vol. 4, No 2/2012


Badania nad możliwością wykorzystania chromatografii wykluczania...<br />

121<br />

Tabela 4. Zawartość modyfikatorów w próbkach badanych oraz obliczone<br />

parametry statystyczne, z wykorzystaniem techniki chromatografii<br />

wykluczania<br />

Table 4. The concentration of modifiers in road asphalt and bitumen, the<br />

calculation of statistical parameters<br />

Parametr<br />

Zawartość<br />

modyfikatora<br />

[%]<br />

Odchylenie<br />

standardowe<br />

Względne<br />

odchylenie<br />

standardowe<br />

Asfalt<br />

modyfikowany<br />

25/55-60<br />

Asfalt<br />

modyfikowany<br />

45/80-60<br />

1<br />

(2008)<br />

2<br />

(2007)<br />

3<br />

(2006)<br />

4,41 3,16 2,114 3,28 3,573<br />

0,24 0,13 0,057 0,24 0,064<br />

0,054 0,043 0,027 0,073 0,013<br />

W przypadku próbki nawierzchni asfaltowej numer 1 zaobserwowano<br />

obniżoną zawartość modyfikatora, co wskazuje na zafałszowanie składu<br />

nawierzchni asfaltowej.<br />

4. WNIOSKI<br />

Wyniki przeprowadzonych badań wykazały, iż oprócz stosowania<br />

spektroskopii w podczerwieni celowe i korzystne jest stosowanie techniki<br />

chromatografii wykluczania do rozdzielania modyfikatorów w<br />

modyfikowanych masach bitumicznych i nawierzchniach asfaltowych. Wyniki<br />

uzyskane tą techniką są powtarzalne i obarczone akceptowalnym błędem.<br />

Błąd oznaczania wynosi do maksymalnie ±7,3% dla zawartości modyfikatora<br />

na poziomie 2-4%, co może wiązać się z wykorzystaniem metody tzw.<br />

„kropli” w celu integracji pików chromatograficznych.<br />

Opracowana procedura rozdzielania modyfikatorów polimerowych<br />

w asfaltach drogowych z zastosowaniem techniki chromatografii<br />

wykluczania wykorzystuje cztery szeregowo połączone kolumny: dwie PS1 i<br />

dwie PS mix o wypełnieniach kopolimer styren – diwinylobenzen oraz eluent<br />

- tetrahydrofuran. Procedura ta zapewnia rozdzielanie modyfikatorów od<br />

pozostałych składników masy bitumicznej i nawierzchni asfaltowych, a w<br />

konsekwencji umożliwia ich oznaczanie. Opracowana procedura jest prosta i<br />

łatwa do wykonania.<br />

Należy podkreślić, że dla powszechnie stosowanych w Polsce<br />

modyfikatorów asfaltowych, rozróżnienie typu modyfikatora jest stosunkowo<br />

mało ważne. Pomimo tego, kolejne badania nad rozdzielaniem,<br />

"rozróżnianiem", a kolejno - oznaczaniem, będą przedmiotem następnej<br />

publikacji, która, dodatkowo będzie uwzględniać również dodatki<br />

„promieniowe", dodatek siarki i dodatek "destruktu gumowego".<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


122 G. Gałęzowska, J. Podwysocka, M. Kamiński<br />

Celowe wydaje się także, aby w kolejnym kroku porównać wyniki<br />

otrzymane techniką SEC z techniką FT-IR oraz sprawdzić czy nie będzie<br />

korzystne zastosowanie rozdzielania asfaltów z dodatkiem modyfikatora wg<br />

normy EN 12916 czy z wykorzystaniem techniki TLC-FID.<br />

CONCLUSION<br />

The study results showed that size exclusion chromatography like<br />

infrared spectroscopy should be use for determination modifiers in bitumen<br />

and road asphalt, the resulting in repeatable measurements with small<br />

errors. For the modifier’s content level of 2-4% the measuring errors had<br />

reached about 7%.<br />

The elaborated procedure for the determination of polymer modifiers<br />

in road asphalt by the size exclusion chromatography requires the use of<br />

four serially connected columns, i.e. two PS1 columns and two PS mix<br />

columns filled with styrene-diwinylbenzene copolymer, and tetrahydrofuran<br />

as eluent. This procedure allows for the separation of modifiers from other<br />

asphalt components as well as the determination of modifier content.<br />

Literatura<br />

(Literature)<br />

1. J. Piłat, P. Radziszewski, Nawierzchnie asfaltowe, Wydawnictwo<br />

Komunikacji i Łączności, Warszawa (2007).<br />

2. K. Błażejowski, S. Styk, Technologia warstw asfaltowych, Wydawnictwo<br />

Komunikacji i Łączności, Warszawa (2004).<br />

3. J. Gudebska, rozprawa doktorska, Chromatografia cieczowa w<br />

oznaczaniu składu grupowego olejów bazowych i asfaltów drogowych,<br />

Gdańsk (1999).<br />

4. AASHTO T302-05, Standardowa metoda badania zawartości polimerów<br />

w asfaltach (2007).<br />

5. S. Peramanu, B. B. Pruden, Molecular weight and specific gravity<br />

distributions for Athabasca and cold lake bitumens and their saturate<br />

aromatic, resin and asphaltene fractions, Ind. Eng. Chem. Res.<br />

38(1999)3121.<br />

6. PN EN 14023, Asfalty i lepiszcza asfaltowe, Zasady klasyfikacji<br />

asfaltów modyfikowanych polimerami (2009).<br />

Camera Separatoria Vol. 4, No 2/2012


CAMERA SEPARATORIA<br />

Volume 4, Number 2 / December 2012, 123-134<br />

Grzegorz BOCZKAJ * , Mariusz JASZCZOŁT, Marian KAMIŃSKI **<br />

Katedra Inżynierii Chemicznej i Procesowej, Wydział Chemiczny, Politechnika Gdańska,<br />

ul. G. Narutowicza 11/12, 80-233 Gdańsk<br />

e-mail: * grzegorz.boczkaj@gmail.com, ** mknkj@chem.pg.gda.pl<br />

Demulgowanie jako efektywna technika rozdzielania<br />

stosowana w procesach oczyszczania ścieków<br />

przemysłowych<br />

Streszczenie: Oczyszczanie ścieków przemysłowych ma na celu, z reguły kilku-etapową,<br />

redukcję ładunku zanieczyszczeń na drodze procesów fizycznych, chemicznych i biologicznych.<br />

W przypadku odprowadzania strumienia ścieków poza zakład, parametry ścieków muszą<br />

spełniać normy określające dopuszczalny poziom zanieczyszczeń organicznych i<br />

nieorganicznych w ściekach.<br />

Duże znaczenie w bilansie ekonomicznym oczyszczania ścieków ma dobór procesów<br />

wstępnego oczyszczania pozwalających na znaczną redukcję zanieczyszczeń w prosty i<br />

niedrogi sposób.<br />

W pracy opisano technologię wstępnego oczyszczania ścieków zawierających zemulgowaną<br />

fazę organiczną na drodze demulgowania z dodatkiem flokulanta kationowego w postaci<br />

polielektrolitu. Wysoka efektywność dobranych warunków demulgowania pozwala na całkowite<br />

wydzielenie fazy organicznej ze ścieków w czasie nieprzekraczającym kilkunastu minut.<br />

Kontrolę efektywności poszczególnych operacji technologicznych badano z zastosowaniem<br />

parametrów sumarycznych (ChZT, BZT) oraz technik chromatograficznych (RP- HPLC, GC-MS,<br />

GC-FID). Zbadano również bio-toksyczność ścieków.<br />

Słowa kluczowe: oczyszczanie ścieków, demulgowanie, analityka procesowa, chromatografia<br />

gazowa<br />

Demulsification - an effective separation technique in the<br />

industrial sewage treatment processes<br />

Abstract: Treatment of industrial wastewaters designed to reduce, usually in several-steps, a<br />

pollution load by physical, chemical and biological methods. In the case of sewage stream<br />

discharge out of the plant, the parameters of wastewater must meet standards defining the<br />

acceptable levels of organic and inorganic pollutants in wastewater.<br />

Great importance in the economic balance of wastewater treatment process plays the selection<br />

of pre-treatment methods allowing a significant reduction of pollutants load by simple and<br />

inexpensive way.<br />

The paper describes the technology of pre-treatment of the effluents containing an emulsified<br />

organic phase by the addition of a cationic polyelectrolyte. The high efficiency of selected<br />

conditions of demulsification allows for complete separation of the organic phase from water in<br />

less than a few minutes.<br />

Efficiency of the operation has been studied using a parameters such as COD and BOD as well<br />

by chromatographic techniques (RP-HPLC, GC-MS, GC-FID). The bio-toxicity of the effluents<br />

has been studied as well.<br />

Key words: wastewater treatment, demulsification, process control, gas chromatography.


124 G. Boczkaj, M. Jaszczołt, M. Kamiński<br />

1. Wstęp<br />

(Introduction)<br />

W Polsce lepiszcza asfaltowe pochodzenia naftowego, najczęściej<br />

wytwarzane są poprzez utlenianie gorącym powietrzem ciężkich<br />

pozostałości po destylacji próżniowej ropy naftowej. Intensywność procesu<br />

utleniania jest zróżnicowana, w zależności od wymaganych parametrów<br />

użytkowych produktu. Do reaktora oksydacji asfaltów wprowadza się wsad w<br />

temperaturze 170-180°C. Po odpowiednim czasie utleniania z reaktora<br />

odbiera się gotowy asfalt. Gazy odlotowe powstające w trakcie procesu są<br />

oczyszczane w skruberze zraszanym np. wodnym roztworem ługu<br />

sodowego i kierowane do dopalacza ("pochodni"). Zagadnienia procesowe i<br />

środowiskowe związane z produkcją lepiszczy asfaltowych opisano m.in. w<br />

[1]. Na świecie stosowane są dwie alternatywne grupy technologii, jedna z<br />

zastosowaniem oleju płuczkowego jako absorbentu, druga z zastosowaniem<br />

wody albo wodnego roztworu wodorotlenku sodu. W przypadku stosowania<br />

roztworu ługu, jako absorbentu, znacząco redukuje się emisję dwutlenku<br />

siarki z procesu dopalania, ale jednoczenie powstają ścieki stanowiące<br />

kondensat olejowy zemulgowany w fazie wodnej z rozpuszczonymi, w obu<br />

fazach, lotnymi związkami organicznymi o silnie zasadowym odczynie [2].<br />

Takie, ścieki są kierowane do zakładowych oczyszczalni ścieków. Główne<br />

etapy oczyszczania tego typu ścieków obejmują, zawsze, separację fazy<br />

olejowej, flokulację, oczyszczanie biologiczne oraz klarowanie.<br />

Systematyczne pogłębianie stopnia przeróbki ropy naftowej i coraz<br />

ostrzejszy reżim technologiczny stosowany podczas utleniania asfaltów,<br />

prowadzi do powstawania związków organicznych, które zatrzymywane w<br />

ługowych ściekach po-oksydacyjnych stabilizują emulsję. Z powodu biotoksyczności<br />

ścieków oraz ich wysokiej złowonności istnieje, potrzeba<br />

wstępnego pre-oczyszczania tego typu ścieków przed ich wprowadzeniem<br />

do oczyszczalni ścieków. Za najbardziej optymalne rozwiązanie uważa się<br />

wstępne wydzielenie fazy organicznej na drodze demulgowania przed<br />

właściwym etapem oczyszczania ścieków. Celowe jest też wstępne<br />

"podczyszczenie" fazy wodnej tych ścieków przed ich wprowadzeniem do<br />

"chemicznej części" oczyszczalni ścieków.<br />

Problematyka procesów demulgowania jest przedmiotem prac<br />

poświęconych procesom rafineryjnym [3-6]. Najczęściej procesy<br />

demulgowania stosuje się podczas wstępnego przygotowania ropy naftowej,<br />

kiedy konieczne jest usunięcie wody, często występującej w formie<br />

zemulgowanej [4-5, 7-8]. Demulgowanie można realizować na kilka<br />

sposobów. Można zastosować operacje wykorzystujące zjawiska fizyczne:<br />

flotację gazem [9],<br />

koalescencję [10],<br />

wymrażanie [11],<br />

filtrację membranową [12-13],<br />

ultradźwięki [14]<br />

Camera Separatoria Vol. 4, No 2/2012


Demulgowanie jako efektywna technika rozdzielania stosowana w procesach...<br />

125<br />

zastosowanie układu podziałowego faza organiczna-faza<br />

wodna w wyniku dodatku świeżego oleju do emulsji [15].<br />

Wysoką efektywność wykazują często procesy demulgowania realizowane<br />

w wyniku działania pola elektrycznego [16-17]. W przypadku odsalania ropy<br />

naftowej wyłącznie te procesy są stosowane.<br />

Alternatywą są operacje stosujące flokulację, w wyniku której,<br />

neutralizowany jest elektrostatyczny ładunek powierzchniowy fazy<br />

organicznej, następuje aglomeracja kropli oleju w ścieku oraz na<br />

powierzchni kłaczków [18]. Flokulant jest najczęściej wprowadzany w<br />

postaci roztworu. Istnieje także możliwość generowania jonów<br />

odpowiedzialnych za neutralizację ładunku powierzchniowego bezpośrednio<br />

w demulgowanym strumieniu [19].<br />

W pracy przedstawiono wyniki badań nad opracowaniem optymalnych<br />

warunków technologii demulgowania ścieków po-oksydacyjnych, jako I-ego<br />

etapu ich pre-oczyszczania.<br />

2. Część eksperymentalna<br />

(Experimental)<br />

Badania wykonywano z zastosowaniem przygotowanego w tym celu<br />

stanowiska badawczego w skali wielkolaboratoryjnej. Dla różnych stężeń<br />

demulgatora oraz różnych rodzajów wody zbadano skuteczność kilku<br />

dostępnych komercyjnie demulgatorów. Badano szybkość wydzielenia fazy<br />

organicznej z fazy wodnej. Rysunek 1 przedstawia schemat procesu. W<br />

badaniach zastosowano flokulanty kationowe o różnej kationowości i różnej<br />

masie cząsteczkowej. A – kationowość 60%, masa cząsteczkowa 6-8 MDa,<br />

B – kationowość 80%, masa cząsteczkowa 6-8 MDa, C – kationowość 80%,<br />

masa cząsteczkowa 1-2 MDa. Roztwory demulgatorów przygotowywano z<br />

zastosowaniem wody demineralizowanej, wody wodociągowej oraz tzw.<br />

wody procesowej (strumień wody poddanej kilku stopniowemu oczyszczaniu<br />

stosowanej w obiegu procesowym rafinerii).<br />

Rys. 1. Schemat układu badawczego<br />

Fig. 1 A. Scheme of the research system (A) A mixer with stripping head, (1) effluents (2)<br />

stripping gas (3) flocculant solution<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


126 G. Boczkaj, M. Jaszczołt, M. Kamiński<br />

W badaniach zastosowano ścieki pooksydacyjne pobierane<br />

bezpośrednio z instalacji oczyszczania gazów pooksydacyjnych. Badania<br />

wykonywano na terenie instalacji oksydacji asfaltów produkowanych z<br />

zastosowaniem technologii Biturox ® . Mieszalnik (A) o objętości ok. 30,0 dm 3 ,<br />

wyposażono w mieszadło łopatkowe płaskie pracujące ze stałą prędkością<br />

obrotową 125 obr/min. Układ wyposażony został także w przegrodę pionową<br />

zapobiegającą powstawaniu leja. Ścieki pooksydacyjne (1) wlewano do<br />

mieszalnika i ogrzewano, do uzyskania temperatury prowadzenia badania -<br />

40°C (temperatura panująca w rozdzielaczu płytowym w instalacji w<br />

rafinerii). Następnie za pomocą pompy perystaltycznej o programowanym<br />

objętościowym natężeniu przepływu, wprowadzano roztwór demulgatora<br />

przez króciec (3) przy dnie mieszalnika. Proces demulgowania prowadzono<br />

w dwóch opcjach: - dynamicznej z wprowadzaniem strumienia gazu (2) i<br />

flotacją fazy organicznej lub w opcji statycznej - z mieszaniem cieczy<br />

wyłącznie podczas dozowania roztworu demulgatora (3) za pomocą<br />

mieszadła, a następnie wyłączano mieszanie.<br />

Próbki ścieków do badań pobierano przed rozpoczęciem<br />

wprowadzania demulgatora oraz po zakończeniu demulgowania. Podczas<br />

pierwszych eksperymentów wprowadzano nadmiar demulgatora i<br />

odnotowano wizualnie zmiany przejrzystości ścieków. Na tej podstawie<br />

wstępnie ustalono zakresy optymalnych objętości roztworów demulgatora w<br />

zależności od stężenia wprowadzanego roztworu. Dla optymalnej objętości<br />

demulgatora przy danym stężeniu, optymalizacji poddano prędkość<br />

wprowadzania demulgatora w funkcji stężenia demulgatora dla kilku<br />

rodzajów wody stanowiącej rozpuszczalnik demulgatora oraz porównano<br />

wyniki tych samych warunków badań dla obu opcji.<br />

Kontrolowano następujące parametry ścieków: Chemiczne zapotrzebowanie<br />

na tlen (ChZT), Biologiczne zapotrzebowanie na tlen (BZT), Toksyczność<br />

ostrą, Zmiany sumarycznej zawartości lotnych związków organicznych<br />

(LZO) (technika HS-GC-FID), zmiany zawartości fazy olejowej w ściekach<br />

(technika RP-HPLC), zmiany zidentyfikowanych lotnych składników ścieków<br />

(technika DHS-GC-MS).<br />

3. Wyniki i dyskusja<br />

(Results and disscussion)<br />

3.1. Dobór optymalnych warunków demulgacji<br />

(Selection of optimal condistion of demusification)<br />

W warunkach procesowych ściek jest wprowadzany do separatora<br />

płytowego, w celu wydzielenia fazy organicznej. Efektywność tego<br />

rozwiązania jest jednak znikoma w przypadku ścieków ługowych. Usuwana<br />

jest tylko niewielka część skondensowanej fazy "olejowej" o niewielkim<br />

stopniu zemulgowania w fazie wodnej ścieku. W badaniach wstępnych<br />

realizowanych w skali laboratoryjnej, testowano flokulanty różnego typu –<br />

Camera Separatoria Vol. 4, No 2/2012


Demulgowanie jako efektywna technika rozdzielania stosowana w procesach...<br />

127<br />

neutralne, anionowe i kationowe. Z wielu przetestowanych flokulantów,<br />

jedynie flokulanty kationowe charakteryzowały się wysoką efektywnością<br />

demulgowania. Jest to związane z występowaniem powierzchniowego<br />

ładunku ujemnego fazy organicznej [17-19]. Stąd, jedynie zastosowanie<br />

flokulantów kationowych, pozwala na neutralizację ładunku<br />

powierzchniowego i wydzielenie fazy organicznej ze ścieków. Dlatego do<br />

badań w skali wielkolaboratoryjnej, wytypowano kilka rodzajów flokulantów<br />

kationowych o różnej kationowości i masie cząsteczkowej. Dobór<br />

optymalnych warunków demulgowania przeprowadzono na podstawie<br />

badań wykonanych dla różnych demulgatorów o różnych stężeniach<br />

roztworu przygotowanymi w wodzie demineralizowanej. Następnie badania<br />

wykonywano z zastosowaniem wody procesowej dostarczonej z rafinerii<br />

ropy naftowej w Gdańsku (Grupa LOTOS S.A.), w celu sprawdzenia wpływu<br />

czystości wody oraz jej pH na efektywność demulgacji fazy organicznej<br />

ścieków. Woda procesowa, charakteryzuje się nieco kwaśnym odczynem pH<br />

na poziomie - w zależności od szarży - 5,8 do 6,5.<br />

Czynnikiem limitującym efektywność demulgowania, w dużym<br />

stopniu, okazuje się intensywność wymiany masy (mieszania). Badany<br />

zakres stężeń demulgatorów pokazał, że w przypadku zbyt wysokiego<br />

stężenia wprowadzany roztwór w postaci gęstej smugi unosi się ku górze<br />

mieszalnika i nie zostaje w sposób równomierny rozprowadzony w ścieku,<br />

co skutkuje niską efektywnością procesu w tych warunkach. Porównanie<br />

efektywności demulgowania pomiędzy statyczną i dynamiczną opcją<br />

procesu wykazało, że nie ma istotnych różnic w efektywności procesu.<br />

Jedyna różnica polega na intensyfikacji mieszania, co pozwala na znacznie<br />

szybsze wprowadzanie roztworu demulgatora do ścieków. W przypadku<br />

opcji statycznej, badania wykazały, że optymalna prędkość wprowadzania<br />

demulgatora wynosi 0,2 dm 3 /min. W przypadku opcji dynamicznej mieszanie<br />

zintensyfikowane pęcherzykami powietrza pozwala na zastosowanie<br />

większego objętościowego natężenia przepływu – do 0,5 dm 3 /min. Z<br />

technologicznego punktu widzenia oznacza to możliwość realizowania<br />

procesu w opcji „statycznej” przy zachowaniu optymalnych warunków z<br />

zastosowaniem mieszadła zapewniającego odpowiednio intensywne<br />

mieszanie. Dobór warunków w skali procesowej będzie wymagał<br />

odpowiednich „analiz ruchowych”. Faza organiczna w wyniku neutralizacji<br />

ładunku powierzchniowego oddziela się samoistnie w sposób grawitacyjny<br />

od fazy wodnej ścieków.<br />

Końcowe stężenie demulgatora w ściekach, zapewniające najwyższą<br />

efektywność procesu wynosi 220 ppm (m/m). Optymalne stężenie<br />

demulgatora ustalono na 0,2% masowego demulgatora we wprowadzanym<br />

roztworze. Na rysunku 2 przedstawiono zależność efektywności demulgacji<br />

od stężenia demulgatora w stosowanym roztworze - dla każdego z trzech<br />

badanych demulgatorów (A-C) przedstawiono procentową zmianę wartości<br />

ChZT i BZT. Dla wszystkich badanych typów demulgatorów uzyskano<br />

jednakowe optymalne stężenie. W oparciu o wyniki badań poszczególnych<br />

parametrów ścieków dokonano wyboru najbardziej efektywnego<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


128 G. Boczkaj, M. Jaszczołt, M. Kamiński<br />

demulgatora. Przedstawione na rysunku 2 dane odnoszą się do<br />

efektywności demulgacji uzyskanej z zastosowaniem wody de mineralizowanej<br />

stosowanej do przygotowania roztworu demulgatora. Badania<br />

wykazały, że w przypadku wszystkich trzech typów demulgatorów możliwe<br />

jest uzyskanie wysokiej efektywności, a najskuteczniejszym demulgatorem<br />

okazał się demulgator C. Szczegółową analizę zmian parametrów ścieków<br />

przedstawiono w sekcji Zmiany składu ścieków w wyniku procesu<br />

demulgacji.<br />

Rys. 2. Wykres zależności efektywności demulgacji (procentowa redukcja wartości ChZT i<br />

BZT)od stężenia i rodzaju demulgatora<br />

Fig. 2 A. Plot of the demulsification effectiveness (COD and BOD percent reduction) depending<br />

on the type and concentration of the flocculant<br />

Na rysunku 3 przedstawiono zmiany przejrzystości ścieków (fotografie<br />

szklanej części mieszalnika) uzyskane w wyniku zastosowania optymalnych<br />

warunków demulgacji. Ścieki w formie pierwotnej są całkowicie<br />

nieprzejrzyste. Podczas demulgowania wrasta przejrzystość ścieków wraz<br />

ze stopniem usunięcia fazy organicznej. W końcowym etapie demulgowania<br />

przejrzystość ścieków jest wysoka - w mieszalniku widoczne są wszystkie<br />

elementy<br />

mechaniczne.<br />

Camera Separatoria Vol. 4, No 2/2012


Demulgowanie jako efektywna technika rozdzielania stosowana w procesach...<br />

129<br />

Rys. 3.<br />

Fig. 3.<br />

Zmiany przejrzystości ścieków w trakcie procesu demulgacji<br />

The changes the sewages transparency during demulsification<br />

3.2. Wpływ sposobu przygotowania demulgatora na efektywność<br />

demulgacji<br />

(Effect of flocculent preparation method on the efficiency of<br />

demulsification)<br />

Stabilność roztworów demulgatorów jest z reguły podawana dla wody<br />

demineralizowanej. W przypadku zastosowania wody o niższej czystości,<br />

może dochodzi do przyspieszonej hydrolizy demulgatorów. Ma to miejsce<br />

szczególnie w przypadku flokulantów w postaci polielektrolitu. W tym<br />

przypadku także pH wody zastosowanej do przygotowania roztworu ma<br />

ogromne znaczenie. Zastosowane kationowe polielektrolity okazały się<br />

niestabilne w przypadku zastosowania wody o pH wyższym od 7. Znany jest<br />

także silny, negatywny, wpływ jonów żelaza, które przyspieszają ich<br />

hydrolizę. W przypadku zastosowania wody o pH na poziomie 10,5-11,0<br />

(odpowiadającym pH ścieków pooksydacyjnych) polielektrolit traci swoje<br />

właściwości już w trakcie jego przygotowania – wizualnie objawia się to<br />

znacznym spadkiem lepkości roztworu. Badania wykazały, że zastosowanie<br />

roztworu przygotowanego w środowisku alkalicznym nie przynosi żadnych<br />

efektów. Najczęściej stosowanym rozwiązaniem w przypadku kationowych<br />

polielektrolitów jest zakwaszanie wody stosowanej do przygotowania<br />

roztworu demulgatora do pH ok. 5.5. Wybór kwasu jest podyktowany<br />

wyłącznie kwestiami finansowymi i ograniczeniami procesowymi związanymi<br />

z obecnością niektórych jonów (chlorki, siarczany).<br />

Z procesowego punktu widzenia, zastosowanie wody<br />

demineralizowanej jest niekorzystne z powodu wysokich kosztów jej<br />

wytwarzania lub zakupu. W skali technicznej zapotrzebowanie na wodę do<br />

przygotowania roztworu demulgatora będzie wynosiło przy objętościowym<br />

natężeniu ścieków na poziomie 3-5 m 3 /h (typowe zakresy dla instalacji typu<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


130 G. Boczkaj, M. Jaszczołt, M. Kamiński<br />

Biturox) ok. 0,5 m 3 /h (10% strumienia ścieków). Z tego powodu<br />

korzystniejsze jest użycie bardziej dostępnych i tańszych strumieni wody, tj.<br />

woda gospodarcza i woda procesowa. Dla wody gospodarczej badania<br />

prowadzono przy pH obojętnym (wartości pierwotna) oraz wartościach pH<br />

5,2 i 4,2 (korekta pH kwasem octowym). Woda procesowa użyta do badań<br />

już pierwotnie miała odczyn lekko kwaśny – wartość pH równa 6. Z tego<br />

powodu wykonano badania z wodą procesową stosowaną bezpośrednio<br />

oraz zakwaszoną kwasem octowym do uzyskania wartości pH 4,5<br />

W przypadku wody gospodarczej (surowej, bez zakwaszania)<br />

demulgatory A i B wykazują nieznaczne różnice w efektywności względem<br />

wody procesowej – redukcja ChZT do poziomu 6500 mgO 2 /dm 3 (redukcja o<br />

46% względem wartości pierwotnej). Zakwaszanie wody gospodarczej do<br />

pH 5,5 lub 4,5 nie wpłynęło w żaden sposób na efektywność procesu. W<br />

przypadku wody gospodarczej (surowej, bez zakwaszania) demulgator C<br />

wykazuje mniejszą efektywność – redukcja ChZT do poziomu 6600<br />

mgO 2 /dm 3 (redukcja o 45%). Zakwaszanie wody do pH 5,5 lub 4,5 pozwala<br />

na uzyskanie wyższej efektywności redukcji ChZT do poziomu 6550<br />

mgO 2 /dm 3 (redukcja o 46%).<br />

W wyniku zastosowania wody procesowej i demulgatorów B i A<br />

uzyskuje się redukcję ChZT z poziomu 12120 mgO 2 /dm 3 (ChZT ścieku<br />

surowego) do poziomu odpowiednio 6510 (redukcja o 46%) mgO 2 /dm 3 i<br />

6370 (redukcja o 47%). Korekta pH wody procesowej z 6 do 4,5 z<br />

zastosowaniem kwasu octowego okazała się nie mieć znaczącego wpływu<br />

na efektywność procesu. Demulgatory B i A pozwoliły na redukcję ChZT do<br />

poziomu odpowiednio 6240 (redukcja o 48,5%) mgO 2 /dm 3 i 6160 mgO 2 /dm 3<br />

(redukcja o 49,2%). Zastosowanie demulgatora C było mniej efektywne, tj.<br />

osiągana jest redukcja ChZT do poziomu 6500 mgO 2 /dm 3 (redukcja o 46%),<br />

a po zakwaszeniu do 6450 mgO 2 /dm 3 (47%). Na tej podstawie można<br />

stwierdzić, ze zastosowanie wody procesowej w pierwotnej formie do<br />

przygotowania demulgatora zapewnia skuteczność procesu demulgowania i<br />

nie ma potrzeby dodatkowej korekty pH.<br />

3.3. Zmiany składu ścieków w wyniku procesu demulgacji<br />

(Changes in the composition of these wages through<br />

demulsification process)<br />

Oprócz podstawowych parametrów procesowych, tj. ChZT czy BZT,<br />

przeanalizowano także zmiany innych ważnych parametrów pozwalających<br />

na bardziej wnikliwą analizę efektywności demulgowania. Przedstawione<br />

poniżej analizy dotyczą wyników badań dla próbek ścieków przed i po<br />

demulgowaniu uzyskanych w warunkach procesu z zastosowaniem wody<br />

procesowej do przygotowania roztworu demulgatora – opcja najbardziej<br />

korzystna ekonomicznie, preferowana w przypadku wdrożenia wyników<br />

badań objętych niniejszą pracą.<br />

Jednym z problemów środowiskowych, związanych ze ściekami<br />

pooksydacyjnymi jest ich wysoka złowonność. Rozpuszczone w ścieku lotne<br />

Camera Separatoria Vol. 4, No 2/2012


Demulgowanie jako efektywna technika rozdzielania stosowana w procesach...<br />

131<br />

i średnio lotne związki organiczne mogą być emitowane do atmosfery<br />

podczas kolejnych etapów oczyszczania, realizowanych w nie<br />

hermetycznych warunkach, tj. separatory flotacyjne, etapy biologicznego<br />

oczyszczania ścieków. Rozwiązanie najczęściej stosowane polegają na<br />

zraszaniu powietrza nad otwartymi zbiornikami odpowiednimi roztworami<br />

mającymi na celu neutralizację zapachu oparów. Z tego punktu widzenia<br />

możliwość znacznego obniżenia zawartości lotnych związków organicznych<br />

jest jednym pozytywnych aspektów stosowania demulgacji.<br />

Badania wstępne wykonane techniką chromatografii gazowej<br />

sprzężonej ze spektrometrią mas (GC-MS) pozwoliły na porównanie zmian<br />

zawartości poszczególnych, zidentyfikowanych LZO w wyniku zastosowania<br />

poszczególnych demulgatorów nie wykazało różnic jakościowych w składzie<br />

ścieków. Różnice w efektywności usuwania LZO dla poszczególnych trzech<br />

demulgatorów są nieznaczne dla poszczególnych związków i nie<br />

przekraczają 10%. Badania wykazały, że związki o charakterze<br />

hydrofobowym są praktycznie w całości usuwane ze ścieków w wyniku<br />

demulgacji. Związki zawierające grupy polarne – alkohole, aldehydy, ketony<br />

są usuwane tym efektywniej im dłuższy łańcuch węglowodorowy posiadają.<br />

Udział związków niskocząsteczkowych (do C 4 ) w sumarycznej zawartości<br />

LZO jest niewielki, ale efektywność ich usuwania nie jest już tak wysoka jak<br />

dla związków zawierających, co najmniej pięć atomów węgla w cząsteczce.<br />

Zmiany sumarycznej zawartości LZO mieszczą się na poziomie 65-67%<br />

redukcji dla wody demineralizowanej i 62-63% redukcji dla wody<br />

procesowej.<br />

W celu zbadania stopnia usunięcia wysoce hydrofobowych<br />

składników ścieków zastosowano wysokosprawną chromatografię cieczową<br />

w układzie faz odwróconych (RP-HPLC). Rozdzielane z zastosowaniem<br />

HPLC składniki ścieków podzielono na pięć grup w zależności od ich<br />

hydrofobowości. Piąta grupa (związki silnie hydrofobowe) była eluowana z<br />

zastosowaniem przepływu zwrotnego eluentu w kolumnie (EBF). Badania<br />

wykazały, że proces demulgowania pozwala na usunięcie niezależnie od<br />

typu demulgatora, powyżej 90% związków silnie hydrofobowych. Stopień<br />

usunięcia związków silnie hydrofobowych dobrze koreluje ze stopniem<br />

redukcji ChZT, stąd w obu przypadkach najkorzystniejszy okazał się<br />

demulgator C (w przypadku zastosowania wody demineralizowanej) i A<br />

(woda procesowa).<br />

Część pozostałych w ściekach związków, wykazująca silną retencję w<br />

zastosowanych warunkach rozdzielania – eluowanych w przepływie<br />

zwrotnym – może być częściowo rozpuszczalna w wodzie i stąd nieusuwana<br />

w wyniku demulgowania, tj. związki o charakterze powierzchniowoczynnym<br />

– długołańcuchowe alkohole czy związki karbonylowe.<br />

W wyniku procesu demulgowania obniżana jest również tzw.<br />

toksyczność ostra ścieków - redukcja o 50%. Wartości EC 20 i EC 50 dla ścieku<br />

po demulgowaniu wynoszą odpowiednio 0,2% i 0,8%. Zmniejszenie<br />

toksyczności, a także ładunku zanieczyszczeń korzystnie wpływa na<br />

„kondycję” osadu czynnego rafineryjnej oczyszczalni ścieków. Pozwala to na<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


132 G. Boczkaj, M. Jaszczołt, M. Kamiński<br />

stosowanie niższych wartości czasu zatrzymania ścieków w<br />

oczyszczalni i obniżenie kosztów oczyszczania.<br />

4. Podsumowanie<br />

(Conclusions)<br />

Porównanie wyników z poszczególnych etapów badań wskazuje, że<br />

efektywność badanych trzech demulgatorów jest zbliżona i stopień redukcji<br />

ChZT oscyluje na poziomie 50% w przypadku zastosowania wody<br />

procesowej i ok. 55 - 60% w przypadku zastosowania wody<br />

demineralizowanej. Dla tych samych warunków procesu efektywność w<br />

odniesieniu do stopnia redukcji biologicznego zapotrzebowania na tlen<br />

(BZT 5 ) wynosi 65 – 69%. Znacznie obniżana jest także zawartość lotnych<br />

związków organicznych (ok. 67%) – maleje również odorowość ścieków,<br />

których zapach po oczyszczaniu charakteryzuje się znacznie mniejszą<br />

intensywnością oraz uciążliwością.<br />

Podobny stopień redukcji ChZT niezależnie od pierwotnej wartości dla<br />

ścieku surowego, wskazuje na względnie stały stosunek substancji wysoce<br />

hydrofobowych – nierozpuszczalnych w zasadowym ścieku i substancji<br />

średnio i nisko hydrofobowych rozpuszczalnych w ściekach. Osiągana<br />

procentowa redukcja dla różnych szarż ścieków jest podobna, ponieważ<br />

demulgacja zapewnia usunięcie jedynie substancji zemulgowanych silnie<br />

hydrofobowych, a odpowiadająca im zawartość rozpuszczalnej „organiki”<br />

wpływa na końcową wartość ChZT ścieków po demulgacji.<br />

W przypadku zastosowania wody demineralizowanej najwyższą<br />

skuteczność zapewnia zastosowanie demulgatora C. Jego wrażliwość na<br />

zanieczyszczenia wody, powoduje jednak, że w przypadku zastosowania<br />

wody procesowej jego efektywność maleje. W przypadku zastosowania do<br />

przygotowania demulgatora wody procesowej, najkorzystniejszym<br />

demulgatorem jest środek A. Uzyskiwane rozdzielenie oraz charakter<br />

fizykochemiczny faz ścieku po demulgowaniu, umożliwia zastosowanie do<br />

wydzielania fazy organicznej ze ścieków typowych układów<br />

technologicznych tj. grawitacyjne separatory płytowe lub separatory olejowe<br />

działające na zasadzie flotacji.<br />

Obecność związków organicznych w ściekach zdemulgowanych, z<br />

której wynika wartość ChZT ścieków po demulgowaniu, oznacza, że są to<br />

związki dobrze lub średnio rozpuszczalne w zasadowym ścieku i ich<br />

usunięcie na drodze demulgacji jest niemożliwe. W celu dalszej redukcji<br />

ładunku zanieczyszczeń organicznych rozpuszczonych w ścieku po<br />

demulgowaniu, konieczne jest włączenie w ciąg technologiczny<br />

dodatkowego procesu działającego na zasadzie utleniania chemicznego lub<br />

foto-utleniania. Badania nad tego typu procesami dedykowanymi<br />

zdemulgowanym ściekom pooksydacyjnym będą tematem kolejnych prac.<br />

Camera Separatoria Vol. 4, No 2/2012


Demulgowanie jako efektywna technika rozdzielania stosowana w procesach...<br />

133<br />

Podziękowania<br />

(Acknowledgements)<br />

Autorzy pragną podziękować Grupie LOTOS S.A. oraz firmie KORONA JV<br />

za pomoc w realizacji badań do niniejszej pracy.<br />

Literatura<br />

(Literature)<br />

1. G. Boczkaj, M. Kamiński, A. Przyjazny, Process control and<br />

investigation of oxidation kinetics of postoxidative effluents using gas<br />

chromatography with pulsed flame photometric detection (GC-PFPD),<br />

Ind. Eng. Chem. Res., 49(2010)12654.<br />

2. G. Boczkaj, M. Gołębiowski, M. Kamiński, P. Stepnowski, Identification<br />

of volatile organic compounds in bitumen post-oxidative sewages by<br />

gas chromatography mass spectrometry (GC-MS) (Identyfikacja lotnych<br />

składników ścieków z instalacji oksydacji asfaltów z wykorzystaniem<br />

chromatografii gazowej sprzężonej ze spektrometrią mas GC-MS),<br />

Cam. Sep., 2(2010)130.<br />

3. A. Bhardwaj, S. Hartland, Applications of surfactants in petroleumindustry,<br />

J. Dispersion Sci. Technol., 14(1993)87.<br />

4. R.A. Mohammed, A. I. Bailey, P. F. Luckham, S. E. Taylor, Dewatering<br />

of crude-oil emulsions .1. Rheological behavior of the crude-oil water<br />

interface, Colloids Surf. A, 80(1993)223.<br />

5. D.G. Thompson, A.S.Taylor, D.E. Graham, Emulsification and<br />

demulsification related to crude-oil production, Colloids Surf.,<br />

15(1985)175.<br />

6. L.X. Xia, S.W. Lu, G.Y. Cao, Stability and demulsification of emulsions<br />

stabilized by asphaltenes or resins, J. Colloid Interface Sci.,<br />

271(2004)504.<br />

7. A. Bhardwaj, S. Hartland, Dynamics of emulsification and<br />

demulsification of water-in-crude oil-emulsions, Ind. Eng. Chem. Res.,<br />

33(1994)1271.<br />

8. M.A. Krawczyk, D.T. Wasan, C.S. Shetty, Chemical demulsification of<br />

petroleum emulsions using oil-soluble demulsifiers, Ind. Eng. Chem.<br />

Res., 30(1991)367.<br />

9. A.A. Al-Shamrani, A. James, H. Xiao, Separation of oil from water by<br />

dissolved air flotation, Colloids Surf. A, 209(2002)15.<br />

10. M. Goto, J. Irie, K. Kondo, F. Nakashio, Electrical demulsification of w/o<br />

emulsion by continuous tubular coalesce, J. Chem. Eng. Jpn.,<br />

22(1989)401.<br />

11. T. Harada, K. Yokomizo, Demulsification of oil-in-water emulsion under<br />

freezing conditions: Effect of crystal structure modifier, J. Am. Oil Chem.<br />

Soc., 77(2000)859.<br />

12. M. Hlavacek, Break-up of oil-in-water emulsions induced by permeation<br />

through a microfiltration membrane, J. Membr. Sci., 102(1995)1.<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


134 G. Boczkaj, M. Jaszczołt, M. Kamiński<br />

13. F.L. Hua, Y.F. Tsang, Y.J. Wang, S.Y. Chan, H. Chua, S.N. Sin,<br />

Performance study of ceramic microfiltration membrane for oily<br />

wastewater treatment, Chem. Eng. J., 128(2007)169.<br />

14. G.D. Pangu, D.L. Feke, Acoustically aided separation of oil droplets<br />

from aqueous emulsions, Chem. Eng. Sci., 59(2004)3183.<br />

15. N.X. Yan, J.H. Masliyah, Characterization and demulsification of solidsstabilized<br />

oil-in-water emulsions.2. demulsification by the addition of<br />

fresh oil, Colloids Surf. A, 96(1995)243.<br />

16. T. Hano, T. Ohtake, K. Takagi, Demulsification kinetics of w/o emulsion<br />

in an ac electric-field,J. Chem. Eng. Jpn., 21(1988) 345.<br />

17. T. Ichikawa, K. Itoh, S. Yamamoto, M. Sumita, Rapid demulsification of<br />

dense oil-in-water emulsion by low external electric field - I.<br />

Experimental evidence, Colloids Surf. A, 242(2004)21.<br />

18. S. Bratskaya, V. Avramenko, S. Schwarz, I. Philippova, Enhanced<br />

flocculation of oil-in-water emulsions by hydrophobically modified<br />

chitosan derivatives, Colloids Surf. A, 275(2006)168.<br />

19. C.L. Yang, Electrochemical coagulation for oily water demulsification,<br />

Sep. Purif. Technol., 54(2007)388.<br />

Camera Separatoria Vol. 4, No 2/2012


Camera Separatoria<br />

PRACE PRZEGLĄDOWE<br />

(REVIEW PAPERS)


CAMERA SEPARATORIA<br />

Volume 4, Number 2 / December 2012, 135-149<br />

Piotr LISOWSKI*, Paweł K. ZARZYCKI<br />

Zakład Toksykologii i Bioanalityki, Wydział Inżynierii Lądowej, Środowiska i Geodezji<br />

Politechnika Koszalińska; Śniadeckich 2, 75-453 Koszalin<br />

Telefon: 48 94 3478595<br />

E-mail: * piotr.lisowski@tu.koszalin.pl; dathor@tlen.pl<br />

Strona domowa: http://www.wbiis.tu.koszalin.pl/labtox<br />

Badania nad mikroprzepływowymi urządzeniami<br />

analitycznymi na bazie papieru (µPADs) – przegląd<br />

literatury<br />

Streszczenie: Mikroprzepływowe, urządzenia analityczne na bazie papieru (microfluidic paperbased<br />

analytical devices; µPADs) są relatywnie nową grupą urządzeń analitycznych. Ich<br />

początków możemy się doszukiwać w technikach chromatograficznych a w szczególności<br />

chromatografii planarnej. Możliwości zastosowania tych urządzeń, głównie do celów tanich,<br />

przesiewowych analiz biochemicznych, kryminalistycznych i środowiskowych są obecnie<br />

przedmiotem intensywnych badań. W niniejszej pracy dokonaliśmy podsumowania, które<br />

obejmuje historię powstania, podstawowe techniki wytwarzania, zastosowania praktyczne oraz<br />

potencjalne możliwości rozwoju takich urządzeń.<br />

Słowa kluczowe: Mikroprzepływowe urządzenia analityczne na bazie papieru (µPADs),<br />

badania jakościowe, badania ilościowe, zastosowania medyczne i biochemiczne, przesiewowe<br />

analizy środowiskowe, chemia analityczna.<br />

1. Wstęp<br />

W ciągu ostatnich dwudziestu kilku lat możemy zaobserwować szybki<br />

i dynamiczny rozwój grupy mikroprzepływowych urządzeń analitycznych,<br />

określanych mianem „laboratorium na chipie” (lab-on-chip; LOC). Badania i<br />

zastosowanie technologii zminiaturyzowanych urządzeń otwiera nowe<br />

możliwości w chemii analitycznej, medycynie, genetyce, biologii komórkowej<br />

i dziedzinach pokrewnych. Proste i powtarzalne operowanie małymi<br />

objętościami płynów za pomocą odpowiednio ukształtowanych kanałów w<br />

skali mikrometrycznej zostało uznane za najważniejszą zaletą laboratoriów<br />

na chipie [1]. Urządzenia te są małe, lekkie, przenośne, tanie w produkcji,<br />

użytkowaniu i utylizacji. Szczególnie ważne dla ich powszechnego<br />

zastosowania są korzyści płynące z możliwości analizowania bardzo małych<br />

próbek oraz z niskiego zużycia odczynników potrzebnych do prowadzenia<br />

analizy [2]. LOC są obecne w wielu zastosowaniach praktycznych w<br />

naukach biomedycznych, genetyce, kryminalistyce, toksykologii,<br />

immunologii, badaniach środowiska, chemii lub biochemii. Są wygodnymi<br />

narzędziami do wykrywania i oznaczania wielu związków nieorganicznych i<br />

organicznych. Oferują możliwości analityczne i diagnostyczne, które mogą<br />

zrewolucjonizować medycynę i przemysł farmaceutyczny.


136 P. Lisowski, P.K. Zarzycki<br />

Z powodzeniem są wykorzystane w analizach klinicznych krwi [3, 4], w celu<br />

wykrywania i identyfikacji patogenów, białek [5-7] i zanieczyszczeń<br />

środowiskowych [8, 9], w badaniach genetycznych [10, 11] oraz w<br />

przemyśle farmaceutycznym [12, 13]. W krajach rozwijających się,<br />

zminiaturyzowane medyczne urządzenia diagnostyczne są szczególnie<br />

ważne dla populacji ludzkich, nie mających bezpośredniego dostępu do<br />

laboratoriów medycznych z podstawowym wyposażeniem diagnostycznymi<br />

[1].<br />

2. Charakterystyka „laboratoriów na chipie”<br />

Rozpatrując urządzenia mikroprzepływowe pod kątem budowy i<br />

technik wytwarzania, możemy wyróżnić dwie główne grupy laboratoriów na<br />

chipie. Pierwszą, określaną jako µTAS (micro total analysis systems),<br />

stanowią urządzenia tworzone na bazie szkła, kwarcu, silikonu i polimerów,<br />

połączone z jednostkami zewnętrznymi (np. samplery, detektory, układy<br />

elektroniczne), w których przepływ płynów kontrolowany jest za pomocą<br />

pomp i zaworów [1]. Przyjmuje się, że pierwsze urządzenie<br />

mikroprzepływowe zbudowane ze szkła i silikonu, opracowano w 1975 roku<br />

[14, 15]. Co ciekawe, działało ono na zasadzie chromatografii gazowej.<br />

Obecnie materiały i techniki wytwarzania µTAS oraz spektrum ich<br />

zastosowań zostały znacznie udoskonalone i poszerzone oraz szeroko<br />

opisane w literaturze naukowej. Z kolei, od 2008 roku możemy<br />

zaobserwować szybki rozwój drugiej grupy mikroprzepływowych urządzeń<br />

analitycznych, których zasadnicza część budowy oparta jest na papierze<br />

(celulozie), i stąd określanych mianem µPADs (microfluidic paper-based<br />

analytical devices). Ma to odzwierciedlenie w ilości prac naukowych<br />

poświeconych tym urządzeniom (Rys. 1). Ten typ obejmują tanie i proste w<br />

produkcji, oparte na bazie papieru chipy, które same w sobie są w pełni<br />

wyposażonymi urządzeniami laboratoryjnymi, przeznaczonymi do<br />

wykonywania określonych zadań, głównie w celu wykrycia różnych rodzajów<br />

substancji [16]. Przepływ płynu jest w nich wywołany siłami kapilarnymi a<br />

jego kontrola jest obecnie przedmiotem badań [17].<br />

Camera Separatoria Vol. 4, No 2/2012


Badania nad mikroprzepływowymi urządzeniami analitycznymi na bazie...<br />

137<br />

Rys. 1. Ilość publikacji w literaturze naukowej dotyczących µPADs w latach 2007-12 (źródło:<br />

Web of Knowlegde; data: 15.01.2013 słowo kluczowe: paper-based microfluidic<br />

devices).<br />

3. Materiały i metody wytwarzania µPADs<br />

Zasadniczym celem przy konstruowaniu µPADs jest uformowanie<br />

hydrofobowych barier określających i ograniczających kierunek przepływu<br />

płynu przez materiał podstawowy (papier), czyli utworzenie mikrotunelu.<br />

Pierwsze mikroprzepływowe urządzenie na bazie papieru (z wyłączeniem<br />

pasków papieru do oznaczania pH) zostało wymyślone i opisane przez<br />

Grupę Whiteside’a z Uniwersytetu Harvarda w 2007 roku [18]. Mikrotunele<br />

wykonano techniką fotolitograficzną, przy użyciu światłoutwardzalnych<br />

polimerów i papieru chromatograficznego a urządzenie służyło do<br />

oznaczania glukozy i białka w moczu. Sposób wykonania takich urządzeń<br />

sprawia, że mogą być wytwarzane nawet w warunkach domowych, przy<br />

użyciu taśmy klejącej i papieru [19].<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


138 P. Lisowski, P.K. Zarzycki<br />

Obecnie w literaturze naukowej opisano wiele technik i materiałów<br />

używanych do wytwarzania hydrofobowych barier, zarówno na typowym<br />

papierze filtracyjnym jak i bardziej specjalistycznym – chromatograficznym.<br />

Popularnymi materiałami są polimery (takie jak fotorezyst SU-8, AKD (dimer<br />

alkilowo-ketenowy), PMMA (polimetakrylan metylu), PDMS (polidimetylosiloksan),<br />

PS (polistyren) używane zarówno w technice fotolitograficznej<br />

[18] jak i i ich roztwory zastępujące atrament w ploterach [20] oraz typowych<br />

drukarkach atramentowych [21]. Często wykorzystywaną grupą materiałów<br />

są woski – używane do drukowania komercyjnego [22, 23] jak również<br />

sitodruku woskowego [24]. Wytwarzanie µPADs odbywa się także za<br />

pomocą druku fleksograficznego [25], używając lasera [26] i plazmy [27]<br />

oraz mechanicznie przy pomocy noży tnących [28, 29].<br />

4. Typowe zastosowania µPADs<br />

Obecnie możemy zaobserwować wzrost zainteresowania nowymi<br />

strategiami pozwalającymi na szybkie analizy, głównie kliniczne i<br />

środowiskowe, bez potrzeby użycia zaawansowanego oprzyrządowania.<br />

Wykorzystanie do tego celu papieru jako materiału podstawowego jest coraz<br />

powszechniejsze, na co wskazują dane z dostępnej literatury naukowej<br />

(Rys. 1). Dzieje się tak z oczywistych względów - w laboratoriach papier jest<br />

powszechnie używanym materiałem, stosowanym do filtracji lub<br />

chromatografowania. Z czterech metod detekcji stosowanych w tego typu<br />

urządzeniach (kolorymetrycznej, elektrochemicznej, chemiluminescencyjnej i<br />

elektrochemiluminescencyjnej) najbardziej popularnymi są kolorymetryczna i<br />

elektrochemiczna [16]. Pierwsze mikroprzepływowe urządzenie<br />

diagnostyczne oparte na papierze służyło do kolorymetrycznego oznaczania<br />

glukozy i białka w moczu [18]. Papierowe urządzenia opracowane przez<br />

zespół naukowy Brennana pozwala w ciągu kilku minut dokonać detekcji<br />

paraoksonu i alfatoksyny B1 przy stężeniach, odpowiednio, ~100 nM i ~30<br />

nM [30]. µPADs używane są w badaniach środowiskowych do oznaczania<br />

metali ciężkich (Pb i Cd) [31], klinicznych do analizy krwi [32-34],<br />

genetycznych do detekcji DNA [35, 36] oraz przy ocenie jakości pożywienia<br />

[37, 38]. Podejmowane są próby do zastosowania ich w badaniach<br />

kryminalistycznych - do detekcji środków wybuchowych [39] i medycznych -<br />

do diagnozowania chorób [40]. Prace naukowców skupiają się także nad<br />

włączeniem µPADs w zakres usług telemedycznych, oraz nad ich<br />

kompatybilnością z urządzeniami zewnętrznymi [41-43].<br />

5. Podsumowanie<br />

Badania nad technologią µPADs są prowadzone od zaledwie kilku lat.<br />

Jak wykazano w tej pracy przeglądowej jest to dziedzina nieustannie<br />

rozwijająca się.<br />

Camera Separatoria Vol. 4, No 2/2012


Badania nad mikroprzepływowymi urządzeniami analitycznymi na bazie...<br />

139<br />

Wykorzystanie papieru, jako materiału bazowego do celów analitycznodiagnostycznych<br />

stanowi centrum zainteresowania wielu ośrodków<br />

naukowych na świecie. Oczywistym jest, że µPADs nie mogą zastąpić<br />

specjalistycznego sprzętu laboratoryjnego (jak chromatografów lub<br />

spektrometrów) używanego w laboratoriach na całym świecie. Jednakże w<br />

sytuacjach, które dotyczą głównie krajów rozwijających się, gdy dostęp do<br />

technologicznie zaawansowanych urządzeń jest utrudniony lub wręcz<br />

niemożliwy, µPADs mogą stanowić bardzo dobrą alternatywę sprzętu<br />

analitycznego. Stanie się to jeszcze bardziej realne, gdy technologia oparta<br />

na µPADs zostanie włączona w zakres usług telemedycznych. W takim<br />

przypadku analiza wyników ze zdjęcia wykonanego prostym telefonem<br />

komórkowym, może być przeprowadzona w specjalistycznym laboratorium<br />

znajdującym się tysiące kilometrów od punktu dokonania pomiaru.<br />

Literatura<br />

1. Whitesides G.M., The origins and the future of microfluidics. Nature 442<br />

(2006) 368-373.<br />

2. Craighead H., Future lab-on-a-chip technologies for interrogating<br />

individual molecules. Nature 442 (2006) 387-393.<br />

3. Hou H.W., Bhagat A.A.S, Lee W.C., Huang S., Han J., Lim C.T.,<br />

Microfluidic devices for blood fractionation. Micromachines 2 (2011)<br />

319-343.<br />

4. Lauks I.R., Microfabricated biosensors and microanalytical systems for<br />

blood analysis. Acc Chem Res 31 (1998) 317-324.<br />

5. Bunyakul N., Edwards K.A., Promptmas C., Baeumner A.J., Cholera<br />

toxin subunit B detection in microfluidic devices. Anal Bioanal Chem<br />

393 (2009) 177-186.<br />

6. Diercks A.H., Ozinsky A., Hansen C.L., Spotts J.M., Rodriguez D.J.,<br />

Aderem A., A microfluidic device for multiplexed protein detection in<br />

nano-liter volumes. Anal Biochem 386 (2009) 30-35.<br />

7. Mairhofer J., Roppert K., Ertl P., Microfluidic systems for pathogen<br />

sensing: a review. Sensors 9 (2009) 4804-4823.<br />

8. Marle L., Greenway G.M., Microfluidic devices for environmental<br />

monitoring. Trends Anal Chem 24(9) (2005) 795-802.<br />

9. Li H.F., Lin J.M., Applications of microfluidic systems in environmental<br />

analysis. Anal Bioanal Chem 393(2) (2009) 555-567.<br />

10. Hopwood A.J., Hurth C., Yang J., Cai Z., Moran N., Lee-Edghill J.G.,<br />

Nordquist A., Lenigk R., Estes M.D., Haley J.P., McAlister C.R., Chen<br />

X., Brooks C., Smith S., Elliott K., Koumi P., Zenhausern F., Tully G.,<br />

Integrated microfluidic system for rapid forensic DNA analysis: sample<br />

collection to DNA profile. Anal Chem 82(16) (2010) 6991-6999.<br />

11. Shui L., Bomer J.G., Jin M., Carlen E.T., van den Berg A., Microfluidic<br />

DNA fragmentation for on-chip genomic analysis. Nanotechnology<br />

22(49) (2011) 494013-494019.<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


140 P. Lisowski, P.K. Zarzycki<br />

12. Sekhon B.S., Kamboj S., Microfluidics technology for drug discovery<br />

and development - an overview. Int J Pharm Tech Res 2(1) (2010) 804-<br />

809.<br />

13. Liu C., Wang L., Xu Z., Li J., Ding X., Wang Q., Chunyu L., A multilayer<br />

microdevice for cell-based high-throughput drug screening. J<br />

Micromech Microeng 22 (2012) 1-7.<br />

14. Terry S.C., A gas chromatographic air analyser fabricated on silicon<br />

wafer using integrated circuit technology. PhD Thesis. (1975) Stanford<br />

CA.<br />

15. Terry S.C., Jerman J.H., Angell J.B., A gas chromatographic air<br />

analyzer fabricated on a silicon wafer. IEEE Trans Electron Devices<br />

26(12) (1979) 1880-1886.<br />

16. Li X., Ballerini D.R., Shen W., A perspective on paper-based<br />

microfluidics: current status and future trends. Biomicrofluidics 6 (2012)<br />

011301-13 .<br />

17. Chen H., Cogswell J., Anagnostopoulos C., Faghri M., A fluidic diode,<br />

valves, and a sequential-loading circuit fabricated on layered paper. Lab<br />

Chip 12 (2012) 2909-2913.<br />

18. Martinez A.W., Phillips S.T., Butte M.J., Whitesides G.M., Patterned<br />

paper as a platform for inexpensive, low-volume, portable bioassays.<br />

Angew Chem Int Ed 46 (2007) 1318-1320.<br />

19. Martinez A.W., Phillips S.T., Whitesides G.M., Three-dimensional<br />

microfluidic devices fabricated in layered paper and tape. Proc Natl<br />

Acad Sci U.S.A. 105(50) (2008) 19606-19611.<br />

20. Bruzewicz D.A., Reches M., Whitesides G.M., Low-cost printing of<br />

poly(dimethylsiloxane) barriers to define microchannels in paper. Anal<br />

Chem 80 (2008) 3387-3392.<br />

21. Abe K., Kotera K., Suzuki K., Citterio D., Inkjet-printed microfluidic<br />

multianalyte chemical sensing paper. Anal Chem 80(18) (2008) 6928-<br />

6934.<br />

22. Carrilho E., Martinez A.W., Whitesides G.M., Understanding wax<br />

printing: a simple micropatterning process for paper-based<br />

microfluidics. Anal Chem 81 (2009) 7091-7095.<br />

23. Lu Y., Shi W., Jiang L., Qin J., Lin B., Rapid prototyping of paper-based<br />

microfluidics with wax for low-cost, portable bioassay. Electrophoresis<br />

30 (2009) 1497-1500.<br />

24. Dungchai W., Chailapakul O., Henry C.S., A low-cost, simple, and rapid<br />

fabrication method for paper-based microfluidics using wax screenprinting.<br />

Analyst 136(1) (2011) 77-82.<br />

25. Olkkonen J., Lehtinen K., Erho T., Flexographically printed fluidic<br />

structures in paper. Anal Chem 82(24) (2010) 10246-10250<br />

26. Chitnis G., Ding Z., Chang C.L., Savran C.A., Ziaie B., Laser-treated<br />

hydrophobic paper: an inexpensive microfluidic platform. Lab Chip 11<br />

(2011) 1161-1165.<br />

27. Li X., Tian J., Nguyen T.H., Shen W., Paper-based microfluidic devices<br />

by plasma treatment. Anal Chem 80(23) (2008) 9131-9134.<br />

Camera Separatoria Vol. 4, No 2/2012


Badania nad mikroprzepływowymi urządzeniami analitycznymi na bazie...<br />

141<br />

28. Fenton E.M., Mascarenas M.R., López G.P., Sibbett S.S., Multiplex<br />

lateral-flow test strips fabricated by two-dimensional shaping. ACS Appl<br />

Mater Interfaces 1(1) (2009) 124-129.<br />

29. Wang W., Wu W.Y., Zhu J.J., Tree-shaped paper strip for<br />

semiquantitative colorimetric detection of protein with self-calibration. J<br />

Chromatogr A 1217(24) (2010) 3896-3899.<br />

30. Hossain S.M.Z., Luckham R.E., Smith A.M., Lebert J.M., Davies L.M.,<br />

Pelton R.H., Filipe C.D.M., Brennan J.D., Development of a bioactive<br />

paper sensor for detection of neurotoxins using piezoelectric inkjet<br />

printing of sol−gel-derived bioinks. Anal Chem 81(2009) 5474-5483.<br />

31. Shi J., Tang F., Xing H., Zheng H., Bi L., Wang W., Electrochemical<br />

detection of Pb and Cd in paper-based microfluidic devices. J Braz<br />

Chem Soc 23(6) (2012)1124-1130.<br />

32. Khan M.S., Thouas G., Shen W., Whyte G., Garnier G., Paper<br />

diagnostic for instantaneous blood typing. Anal Chem 82 (2010) 4158-<br />

4164.<br />

33. Li M., Tian J., Al-Tamimi M., Shen W., Paper-based blood-typing device<br />

that reports patient's blood type "in writing". Angew Chem Int Ed 51<br />

(2012) 5497-5501.<br />

34. Su J., Al-Tamimi M., Garnier G., Engineering paper as a substrate for<br />

blood typing bio-diagnostics. Cellulose 19 (2012) 1749-1758.<br />

35. Ali M.M., Aguirre S.D., Xu Y., Filipe C.D.M., Pelton R., Li Y., Detection<br />

of DNA using bioactive paper strips. Chem Commun 43 (2009) 6640-<br />

6642.<br />

36. Lu J., Ge S.., Ge L., Yan M., Yu J., Electrochemical DNA sensor based<br />

on three-dimensional folding paper device for specific and sensitive<br />

point-of-care testing. Electrochimica Acta 80 (2012) 334-341.<br />

37. Hossain S.M.Z., Luckham R.E., McFadden M.J., Brennan J.D.,<br />

Reagentless bidirectional lateral flow bioactive paper sensors for<br />

detection of pesticides in beverage and food samples. Anal Chem 81<br />

(2009) 9055-9064.<br />

38. Nie Z.H., Deiss F., Liu X.Y., Akbulut O., Whitesides G.M., Integration of<br />

paper-based microfluidic devices with commercial electrochemical<br />

readers. Lab Chip 10 (2010) 3163-3169.<br />

39. Doble P., Blanes L., Development of microfluidic paper-based analytical<br />

devices (μ-PADs) using a 3D printer: in-field screening of organic<br />

explosives. In: Bachelor of forensic science (honours) in applied<br />

chemistry; Forensic Honours Projects 2013, University of Technology,<br />

Sydney, 2012.<br />

40. Ge L., Wang S., Song X., Ge S., Yu J., 3D origami-based multifunctionintegrated<br />

immunodevice: Low-cost and multiplexed sandwich<br />

chemiluminescence immunoassay on microfluidic paper-based<br />

analytical device. Lab Chip 12 (2012) 3150-3158.<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


142 P. Lisowski, P.K. Zarzycki<br />

41. Martinez A.W., Scott T.P., Carrilho E., Thomas III S.W., Sindi H.,<br />

Whitesides G.M., Simple telemedicine for developing regions: camera<br />

phones and paper-based microfluidic devices for real-time, off-site<br />

diagnosis. Anal Chem 80(10) (2008) 3699-3707.<br />

42. Liu H., Crooks R.M., Paper-based electrochemical sensing platform<br />

with integral battery and electrochromic read-out. Anal Chem 84(5)<br />

(2012) 2528-2532.<br />

43. Vella S.J., Beattie P., Cademartiri R., Laromaine A., Martinez A.W.,<br />

Phillips S.T., Mirica K.A., Whitesides G.M., Measuring markers of liver<br />

function using a micropatterned paper device designed for blood from a<br />

fingerstick. Anal Chem 84 (2012) 2883-2891.<br />

Camera Separatoria Vol. 4, No 2/2012


Advances on paper-based analytical devices (µPADs) – literature review<br />

143<br />

Piotr LISOWSKI, Paweł K. ZARZYCKI<br />

Section of Toxicology and Bioanalytics, Faculty of Civil Engineering, Environmental and<br />

Geodetic Sciences<br />

Koszalin University of Technology, Sniadeckich 2, 75-453 Koszalin, Poland<br />

Phone: 48 94 3478595<br />

E-mail: piotr.lisowski@tu.koszalin.pl; dathor@tlen.pl<br />

Webpage address: http://www.wbiis.tu.koszalin.pl/labtox<br />

Advances on paper-based analytical devices (µPADs) –<br />

literature review<br />

Abstract: Microfluidic paper-based analytical devices (µPADs) are relatively new group of<br />

analytical tools. Work principles of such devices partially evolved from chromatographic<br />

techniques, particularly planar chromatography. Recently, analytical devices based on paper<br />

are subject of extensive research, mostly focused on fast and non-expensive biochemical<br />

analysis but also for screening of medical and environmental samples. Attempts are being<br />

made for their applications in forensic - to organic explosives detection and in medicine - to<br />

diseases diagnosis. In this short review we presented a recent advances in area of µPADs<br />

technology.<br />

Key Words: Microfluidic paper-based analytical devices (µPADs); qualitative analysis,<br />

quantitative analysis, medical and biochemical analysis, environmental screening, analytical<br />

chemistry.<br />

1. Introduction<br />

Laboratories on a chip (lab-on-chip or LOC) – microfluidic analytical<br />

devices - are subject of extensive research over last twenty years. Through<br />

them new ways in medicine, biochemistry, genetic, cell biology can be<br />

opened. Simple and robust manipulation of small volumes of fluids within<br />

microchannels has been regarded as the most important advantage of<br />

laboratories on a chip [1]. Especially important for their application are the<br />

benefits flowing of low consumption of reagents and analytes [2]. LOC are<br />

used in a wide range of practical applications, particularly in the biomedical<br />

sciences and environmental studies, also in biochemistry. They are<br />

recognized as the convenient tools for detection and determination of many<br />

inorganic and organic compounds. Moreover, they provide number of<br />

analytical and diagnostic capabilities, which may revolutionize medicine and<br />

the pharmaceutical industry. In recent times labs-on-chip are successfully<br />

used in clinical analysis of blood [3, 4], detection of proteins and pathogens<br />

[5-7], environmental pollutants [8, 9], genetic studies [10, 11] and the<br />

pharmaceutical industry [12, 13]. Miniaturized medical diagnostics devices<br />

can be important for people living in developing countries, where access to<br />

laboratories or diagnostic equipment is difficult or even impossible [1].<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


144 P. Lisowski, P.K. Zarzycki<br />

2. Characterization of „lab-on-chip”<br />

Considering construction and manufacturing techniques of the<br />

microfluidic devices, we may distinguish two main groups of laboratories on<br />

a chip. The first one gather devices known as μTAS (micro total analysis<br />

systems) that are created on the basis of glass, quartz, silicon and polymers<br />

and combined with external units (such as samplers, detectors, electronic<br />

units), in which fluid flow is controlled by pumps and valves [1]. It is<br />

assumed, that the first device constructed from glass and silicon was<br />

developed in 1975 [14, 15]. Interestingly, it was based on gas<br />

chromatography principles. Currently, materials and manufacturing<br />

techniques of μTAS, as well as their application range have been greatly<br />

improved and expanded, which is widely described in the scientific literature.<br />

From the other side, since year 2008, we may observe rapid development of<br />

another group of microfluidic analytical devices, where the major part of the<br />

construction is based on a paper material (cellulose) - and hence known as<br />

μPADs (paper-based microfluidic analytical devices) (Fig. 1). This type<br />

includes non-expensive and easy to make paper chips, which can be<br />

considered as fully equipped laboratory instruments. They are designed to<br />

perform specific tasks, mainly in order to detect different types of substances<br />

[16]. In such devices the fluid flow is caused by capillary forces, which<br />

controlling is currently under extensive investigation [17].<br />

Camera Separatoria Vol. 4, No 2/2012


Advances on paper-based analytical devices (µPADs) – literature review<br />

145<br />

Fig. 1. Research papers concerning µPADs in years 2007-12 (source: Web of Knowledge;<br />

data: 15.01.2103; key word: paper-based microfluidic devices).<br />

3. µPADs - materials and manufacturing techniques<br />

The main goal of manufacturing a μPADs is to create hydrophobic<br />

barriers, which are directing fluid flow through microchannels within the base<br />

material (paper). The first microfluidic device based on paper (with the<br />

exception of paper strips to pH determination) was invented and described<br />

by Whiteside Group at Harvard University in 2007 [18]. Photolithography<br />

technique to made microtunnels was performed using a photoresist polymer<br />

and chromatography paper. This device was used for glucose and protein<br />

determination in the urine. It is noteworthy to say that μPADs production is<br />

possible even in home using adhesive tape and paper [19].<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


146 P. Lisowski, P.K. Zarzycki<br />

Currently, the scientific publications describe a number of techniques and<br />

materials used to form hydrophobic barriers, both on the typical filter or<br />

chromatographic paper. They involve polymers (such as SU-8 photoresist,<br />

AKD (alkyl ketene dimer), PMMA (poly(methyl methacrylate), PDMS<br />

(polydimethylsiloxane), PS (polystyrene)) used in the photolithographic<br />

technique [18] and their solutions used in converted ink plotters [20] and<br />

typical ink jet printers [21]. Next group of materials consist a waxes used for<br />

commercial printing [22, 23] and screen-printing [24]. μPADs can be also<br />

created by using flexographic printing [25], a laser [26] and plasma treatment<br />

[27] and finally - by cutting knives [28, 29].<br />

4. µPADs - typical applications<br />

Today, we may observe an increase of interest in new strategies<br />

allowing to rapid analysis and diagnostics for clinical, environmental and<br />

forensic purposes without sophisticated instrumentation. According to<br />

literature data, application of paper systematically increase, as can be seen<br />

from the graph presented in Figure 1. In laboratories, paper is commonly<br />

used as basic material for filtration and chromatography. Typical µPADs<br />

detection systems are based on colorimetry, electrochemistry,<br />

chemiluminescence and electrochemiluminescence, however colorimetric<br />

and electrochemical qualitative and quantitative determinations are the most<br />

popular [16]. The first diagnostic system involving paper based device was<br />

used for colorimetric determination of glucose and protein in urine [18].<br />

Brennan's research team developed a device, which allow to perform a rapid<br />

(in few minutes) detection of paraoxon and aflatoxin B1 at concentrations~<br />

100 nM and ~ 30 nM, respectively [30]. μPADs are used in environmental<br />

studies for heavy metals determination (Pb and Cd) [31], in clinical analysis<br />

of blood [32-34] and genetic for DNA detection [35, 36], also in food quality<br />

control [37, 38]. Attempts are being made for their applications in forensic -<br />

to organic explosives detection [39] and in medicine - to diseases diagnosis<br />

[40]. Numbers of research teams are extensively working on application of<br />

μPADs in telemedicine services as well as its hyphenation with the external<br />

devices [41-43].<br />

5. Conclusions<br />

Research concerning μPADs is carried out for last few years.<br />

However, as it is presented in this survey, the usage of paper as the base<br />

material for analytical and diagnostic purposes is in the center of interest of<br />

many researchers in the world. It is obvious that μPADs cannot replace<br />

sophisticated laboratory equipment, including spectrometers or<br />

chromatographs, which is used in laboratories around the world. However, in<br />

specific situations, especially in developing countries, μPADs may be a very<br />

good alternative, when access to hi-tech equipment is very limited. This<br />

becomes even more real, when such methodology will be included in the<br />

Camera Separatoria Vol. 4, No 2/2012


Advances on paper-based analytical devices (µPADs) – literature review<br />

147<br />

scope of telemedicine services. Under such conditions, μPADs photo taken<br />

by mobile phone can be instantly transferred thousands miles away from<br />

analysis place to specialized laboratory.<br />

References<br />

1. Whitesides G.M., The origins and the future of microfluidics. Nature 442<br />

(2006)368-373.<br />

2. Craighead H., Future lab-on-a-chip technologies for interrogating<br />

individual molecules. Nature 442 (2006) 387-393.<br />

3. Hou H.W., Bhagat A.A.S, Lee W.C., Huang S., Han J., Lim C.T.,<br />

Microfluidic devices for blood fractionation. Micromachines 2 (2011)<br />

319-343.<br />

4. Lauks I.R., Microfabricated biosensors and microanalytical systems for<br />

blood analysis. Acc Chem Res 31 (1998) 317-324.<br />

5. Bunyakul N., Edwards K.A., Promptmas C., Baeumner A.J., Cholera<br />

toxin subunit B detection in microfluidic devices. Anal Bioanal Chem<br />

393 (2009) 177-186.<br />

6. Diercks A.H., Ozinsky A., Hansen C.L., Spotts J.M., Rodriguez D.J.,<br />

Aderem A., A microfluidic device for multiplexed protein detection in<br />

nano-liter volumes. Anal Biochem 386 (2009) 30-35.<br />

7. Mairhofer J., Roppert K., Ertl P., Microfluidic systems for pathogen<br />

sensing: a review. Sensors 9 (2009) 4804-4823.<br />

8. Marle L., Greenway G.M., Microfluidic devices for environmental<br />

monitoring. Trends Anal Chem 24(9) (2005) 795-802.<br />

9. Li H.F., Lin J.M., Applications of microfluidic systems in environmental<br />

analysis. Anal Bioanal Chem 393(2) (2009) 555-567.<br />

10. Hopwood A.J., Hurth C., Yang J., Cai Z., Moran N., Lee-Edghill J.G.,<br />

Nordquist A., Lenigk R., Estes M.D., Haley J.P., McAlister C.R., Chen<br />

X., Brooks C., Smith S., Elliott K., Koumi P., Zenhausern F., Tully G.,<br />

Integrated microfluidic system for rapid forensic DNA analysis: sample<br />

collection to DNA profile. Anal Chem 82(16) (2010) 6991-6999.<br />

11. Shui L., Bomer J.G., Jin M., Carlen E.T., van den Berg A., Microfluidic<br />

DNA fragmentation for on-chip genomic analysis. Nanotechnology<br />

22(49) (2011) 494013-494019.<br />

12. Sekhon B.S., Kamboj S., Microfluidics technology for drug discovery<br />

and development - an overview. Int J Pharm Tech Res 2(1) (2010) 804-<br />

809.<br />

13. Liu C., Wang L., Xu Z., Li J., Ding X., Wang Q., Chunyu L., A multilayer<br />

microdevice for cell-based high-throughput drug screening. J<br />

Micromech Microeng 22 (2012) 1-7.<br />

14. Terry S.C., A gas chromatographic air analyser fabricated on silicon<br />

wafer using integrated circuit technology. PhD Thesis. (1975) Stanford<br />

CA.<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


148 P. Lisowski, P.K. Zarzycki<br />

15. Terry S.C., Jerman J.H., Angell J.B., A gas chromatographic air<br />

analyzer fabricated on a silicon wafer. IEEE Trans Electron Devices<br />

26(12) (1979) 1880-1886.<br />

16. Li X., Ballerini D.R., Shen W., A perspective on paper-based<br />

microfluidics: current status and future trends. Biomicrofluidics 6 (2012)<br />

011301-13 .<br />

17. Chen H., Cogswell J., Anagnostopoulos C., Faghri M., A fluidic diode,<br />

valves, and a sequential-loading circuit fabricated on layered paper. Lab<br />

Chip 12 (2012) 2909-2913.<br />

18. Martinez A.W., Phillips S.T., Butte M.J., Whitesides G.M., Patterned<br />

paper as a platform for inexpensive, low-volume, portable bioassays.<br />

Angew Chem Int Ed 46 (2007) 1318-1320.<br />

19. Martinez A.W., Phillips S.T., Whitesides G.M., Three-dimensional<br />

microfluidic devices fabricated in layered paper and tape. Proc Natl<br />

Acad Sci U.S.A. 105(50) (2008) 19606-19611.<br />

20. Bruzewicz D.A., Reches M., Whitesides G.M., Low-cost printing of<br />

poly(dimethylsiloxane) barriers to define microchannels in paper. Anal<br />

Chem 80 (2008) 3387-3392.<br />

21. Abe K., Kotera K., Suzuki K., Citterio D., Inkjet-printed microfluidic<br />

multianalyte chemical sensing paper. Anal Chem 80(18) (2008) 6928-<br />

6934.<br />

22. Carrilho E., Martinez A.W., Whitesides G.M., Understanding wax<br />

printing: a simple micropatterning process for paper-based<br />

microfluidics. Anal Chem 81 (2009) 7091-7095.<br />

23. Lu Y., Shi W., Jiang L., Qin J., Lin B., Rapid prototyping of paper-based<br />

microfluidics with wax for low-cost, portable bioassay. Electrophoresis<br />

30 (2009) 1497-1500.<br />

24. Dungchai W., Chailapakul O., Henry C.S., A low-cost, simple, and rapid<br />

fabrication method for paper-based microfluidics using wax screenprinting.<br />

Analyst 136(1) (2011) 77-82.<br />

25. Olkkonen J., Lehtinen K., Erho T., Flexographically printed fluidic<br />

structures in paper. Anal Chem 82(24) (2010) 10246-10250.<br />

26. Chitnis G., Ding Z., Chang C.L., Savran C.A., Ziaie B., Laser-treated<br />

hydrophobic paper: an inexpensive microfluidic platform. Lab Chip 11<br />

(2011) 1161-1165.<br />

27. Li X., Tian J., Nguyen T.H., Shen W., Paper-based microfluidic devices<br />

by plasma treatment. Anal Chem 80(23) (2008) 9131-9134.<br />

28. Fenton E.M., Mascarenas M.R., López G.P., Sibbett S.S., Multiplex<br />

lateral-flow test strips fabricated by two-dimensional shaping. ACS Appl<br />

Mater Interfaces 1(1) (2009) 124-129.<br />

29. Wang W., Wu W.Y., Zhu J.J., Tree-shaped paper strip for<br />

semiquantitative colorimetric detection of protein with self-calibration. J<br />

Chromatogr A 1217(24) (2010) 3896-3899.<br />

30. Hossain S.M.Z., Luckham R.E., Smith A.M., Lebert J.M., Davies L.M.,<br />

Pelton R.H., Filipe C.D.M., Brennan J.D., Development of a bioactive<br />

Camera Separatoria Vol. 4, No 2/2012


Advances on paper-based analytical devices (µPADs) – literature review<br />

149<br />

paper sensor for detection of neurotoxins using piezoelectric inkjet<br />

printing of sol−gel-derived bioinks. Anal Chem 81(2009) 5474-5483.<br />

31. Shi J., Tang F., Xing H., Zheng H., Bi L., Wang W., Electrochemical<br />

detection of Pb and Cd in paper-based microfluidic devices. J Braz<br />

Chem Soc 23(6) (2012)1124-1130.<br />

32. Khan M.S., Thouas G., Shen W., Whyte G., Garnier G., Paper<br />

diagnostic for instantaneous blood typing. Anal Chem 82 (2010) 4158-<br />

4164.<br />

33. Li M., Tian J., Al-Tamimi M., Shen W., Paper-based blood-typing device<br />

that reports patient's blood type "in writing". Angew Chem Int Ed 51<br />

(2012) 5497-5501.<br />

34. Su J., Al-Tamimi M., Garnier G., Engineering paper as a substrate for<br />

blood typing bio-diagnostics. Cellulose 19 (2012) 1749-1758.<br />

35. Ali M.M., Aguirre S.D., Xu Y., Filipe C.D.M., Pelton R., Li Y., Detection<br />

of DNA using bioactive paper strips. Chem Commun 43 (2009) 6640-<br />

6642.<br />

36. Lu J., Ge S.., Ge L., Yan M., Yu J., Electrochemical DNA sensor based<br />

on three-dimensional folding paper device for specific and sensitive<br />

point-of-care testing. Electrochimica Acta 80 (2012) 334-341.<br />

37. Hossain S.M.Z., Luckham R.E., McFadden M.J., Brennan J.D.,<br />

Reagentless bidirectional lateral flow bioactive paper sensors for<br />

detection of pesticides in beverage and food samples. Anal Chem 81<br />

(2009) 9055-9064.<br />

38. Nie Z.H., Deiss F., Liu X.Y., Akbulut O., Whitesides G.M., Integration of<br />

paper-based microfluidic devices with commercial electrochemical<br />

readers. Lab Chip 10 (2010) 3163-3169.<br />

39. Doble P., Blanes L., Development of microfluidic paper-based analytical<br />

devices (μ-PADs) using a 3D printer: in-field screening of organic<br />

explosives. In: Bachelor of forensic science (honours) in applied<br />

chemistry; Forensic Honours Projects 2013, University of Technology,<br />

Sydney, 2012.<br />

40. Ge L., Wang S., Song X., Ge S., Yu J., 3D origami-based multifunctionintegrated<br />

immunodevice: Low-cost and multiplexed sandwich<br />

chemiluminescence immunoassay on microfluidic paper-based<br />

analytical device. Lab Chip 12 (2012) 3150-3158.<br />

41. Martinez A.W., Scott T.P., Carrilho E., Thomas III S.W., Sindi H.,<br />

Whitesides G.M., Simple telemedicine for developing regions: camera<br />

phones and paper-based microfluidic devices for real-time, off-site<br />

diagnosis. Anal Chem 80(10) (2008) 3699-3707.<br />

42. Liu H., Crooks R.M., Paper-based electrochemical sensing platform<br />

with integral battery and electrochromic read-out. Anal Chem 84(5)<br />

(2012) 2528-2532.<br />

43. Vella S.J., Beattie P., Cademartiri R., Laromaine A., Martinez A.W.,<br />

Phillips S.T., Mirica K.A., Whitesides G.M., Measuring markers of liver<br />

function using a micropatterned paper device designed for blood from a<br />

fingerstick. Anal Chem 84 (2012) 2883-2891.<br />

Vol. 4, No 2/2012<br />

Camera Separatoria


Camera Separatoria<br />

POZOSTAŁE<br />

(OTHERS)


Jeden, dwa, trzy …… Podlaskie Spotkania Chromatograficzne<br />

czyli krótka historia Podlaskich Spotkań Chromatograficznych<br />

Bronisław K. GŁÓD<br />

Zakład Chemii Analitycznej, Instytut Chemii, Uniwersytet<br />

Przyrodniczo-Humanistyczny w Siedlcach<br />

ul. 3 Maja 54, 08-110 Siedlce,<br />

Już cztery razy (począwszy od 2009 r.) odbyły się, w Reymontówce -<br />

Domu Pracy Twórczej, Podlaskie Spotkania Chromatograficzne.<br />

Zabytkowy dworek wybudowano w połowie XIX w. dla rodziny<br />

Różańskich. W 1926 r. dworek wraz z 300 ha gruntów kupiła wdowa<br />

po Władysławie Reymoncie - Aurelia, przeznaczywszy na ten cel<br />

część pieniędzy z nagrody Nobla, jaką otrzymał Reymont za powieść<br />

Chłopi.<br />

I Podlaskie Spotkanie Chromatograficzne odbyło się w dniach od 20<br />

do 23 września 2009 r. pod honorowym patronatem JM Rektora<br />

Akademii Podlaskiej i prezydenta miasta Siedlce. Organizatorem<br />

spotkania była Akademia Podlaska (Zakład Chemii Analitycznej).<br />

Materiały konferencyjne zostały wydane w postaci książki<br />

abstraktów. Dodatkowo uczestnicy otrzymali dwie monografie:<br />

Wysokosprawna chromatografia cieczowa: Podstawy teoretyczne<br />

(B.K. Głód, P. Piszcz) i Postępy chromatografii (Monografie nr 111,<br />

B.K. Głód, red.). Druga z nich pomyślana została jako pierwsza z<br />

cyklu monografii poświęconych najnowszym trendom w<br />

chromatografii, zawierająca prace przeglądowe w języku polskim.<br />

Spotkaniom towarzyszą imprezy dodatkowe. Wycieczka po Siedlcach<br />

i okolicach obejmowała zwiedzanie zabytkowego, XVIII-wiecznego<br />

kościoła w Żeliszewie Podkościelnym, Siedlec, pałacu Ogińskich w<br />

Siedlcach, który obecnie jest siedzibą władz Akademii Podlaskiej,<br />

oraz Muzeum Diecezjalne w Siedlcach, gdzie podziwiano Ekstazę św.<br />

Franciszka, dzieło El Greca. Podczas II Spotkania zorganizowana<br />

została wycieczka do Pałacu Ogińskich w Siedlcach, który jest<br />

siedzibą władz Uniwersytetu Przyrodniczo-Humanistycznego w<br />

Siedlcach, oraz Muzeum Architektury Drewnianej Regionu<br />

Siedleckiego w Suchej.<br />

W trakcie trzeciego Spotkania zorganizowana została wycieczka do<br />

miejscowości Mielnik nad Bugiem oraz na świętą Górę Grabarkę. Po<br />

drodze uczestnicy przejechali przez Drohiczyn oraz najmniejszą<br />

miejscowość w Polsce, liczącą tylko jednego mieszkańca, Końskie<br />

Góry.<br />

Podczas 1-szych Spotkań zrodził się pomysł utworzenia Polskiego<br />

Towarzystwa Nauk o Rozdzielaniu. W trakcie 2-giego Spotkania<br />

odbyło się zebranie Polskiego Towarzystwa Nauk o Rozdzielaniu.<br />

Ustalono, że istnieje potrzeba stworzenia polskiego czasopisma<br />

poświęconego temu działowi nauki. Przyjmie ono nazwę Camera<br />

Separatoria, pierwszego państwowego laboratorium poświęconego<br />

rozdzielaniu złota od srebra. Zostało ono powołane do życia przez<br />

Zygmunta I Starego w 1517 roku. Ponadto produkowano tam kwas<br />

azotowy, siarkowy i wodę królewską, a także oczyszczano siarkę,<br />

rtęć, antymon, glejtę (tlenek ołowiu) i ołów. Pierwszym dyrektorem<br />

Camera Separatoria został krakowski mieszczanin Kasper Ber. W<br />

Camera Separatoria będą zamieszczane w języku polskim lub<br />

angielskim artykuły oryginalne i przeglądowe poświęcone różnym<br />

działom nauki, techniki i technologii rozdzielania. Pierwsze wydanie<br />

ukazało się w 2011 r. z numerem 3, jako kontynuacja Postępów<br />

Chromatografii.<br />

Podczas 3-ciego Spotkania firma Merck ufundowała nagrodę za<br />

najlepszą prezentacją posterową oraz dwie nagrody pocieszenia.<br />

Otrzymali je: (i) Adrian Szabrański, Pro- i antyoksydanty w procesie<br />

fermentacji miodów, UP-HwS; (ii) Magdalena Caban, Zastosowanie<br />

złóż ekstrakcyjnych o charakterze polimerycznym do wydzielania<br />

leków o właściwościach zasadowych, UG oraz (iii) Kinga<br />

Marszewska, Wykorzystanie technik chromatograficznych do<br />

określania składu cukrowego O-polisacharydów wyodrębnionych z<br />

wybranych szczepów bakterii rodzaju Cronobacter, UG.


Camera Separatoria<br />

INSTRUKCJE DLA AUTORÓW<br />

W Camera Separatoria wydawane są artykuły oryginalne (nie<br />

publikowane wcześniej) oraz przeglądowe poświęcone różnym działom<br />

nauki, techniki i technologii rozdzielania. Dodatkowo publikowane będą listy<br />

do redakcji, informacje na temat aparatury naukowej, recenzje książek,<br />

reklamy, materiały firmowe, sprawozdania redakcji jak również informacje o<br />

konferencjach.<br />

Artykuł do <strong>CamSep</strong> przygotowany w edytorze Microsoft Word 2003<br />

lub nowszym (w formacie .doc lub .docx) zgodnie z przedstawionym poniżej<br />

opisem należy przesłać wraz z listem motywacyjnym na adres e-mail:<br />

psc1@onet.eu. Nie ma ograniczenia co do długości artykułu.<br />

* * *<br />

Jan KOWALSKI 1 , Anna KOWALSKA 2* (Arial 10 pkt., bold)<br />

1<br />

Uniwersytet Przyrodniczo-Humanistyczny, Wydział Nauk Ścisłych, Instytut Chemii,<br />

Zakład Chemii Analitycznej, ul. 3 Maja 54, 08-110 Siedlce,<br />

e-mail: psc1@onet.eu<br />

2<br />

Uniwersytet … (Afiliacja – Arial 8 pkt., normal bez boldu)<br />

Tytuł artykułu w języku polskim – 12 pkt. Arial bold<br />

Streszczenie: (Arial 8 pkt. normal bold). Treść streszczenia – Arial 8 pkt. kursywa bez boldu.<br />

Streszczenie polskojęzyczne powinno zawierać około 500 – 700 znaków (ze spacjami). Należy<br />

w nim krótko wskazać czego dotyczy artykuł, co jest w nim nowego oraz podsumowanie<br />

wniosków.<br />

Słowa kluczowe: Arial 8 pkt., bez boldu, kursywą<br />

Tytuł artykułu w języku angielskim – 12 pkt. Arial bold -<br />

kursywa


Instrukcje dla autorów<br />

173<br />

Abstract: (Arial 8 pkt. normal bold). Streszczenie anglojęzyczne – Arial 8 pkt. kursywa bez<br />

boldu, powinno być rozszerzone, o objętości około 1000 – 1200 znaków (ze spacjami). Powinno<br />

zawierać: wskazanie czego dotyczy artykuł, co jest w nim nowego oraz podsumowanie<br />

wniosków.<br />

Key words: Arial 8 pkt., bez boldu, kursywą<br />

* autor do korespondencji<br />

Podtytuły – Arial 11 pkt., bold (Wstęp, Część eksperymentalna, Wyniki i<br />

dyskusja, Podsumowanie lub Wnioski, Literatura itp.) – wersja polska -<br />

normal i (angielska - kursywą),<br />

śródtytuły – Arial 10 pkt., bold, wersja polska - normal i (angielska -<br />

kursywą)<br />

Wcięcia akapitowe na 1,0 cm, tekst podstawowy wyjustowany – Arial<br />

10 pkt., odstępy między wierszami pojedyncze. Nie wymuszać w żaden<br />

sposób podziałów wierszy. Marginesy dostosować tak, aby wysokość<br />

kolumny tekstowej miała 19 cm (bez nr stron), a szerokość 12 cm - zgodnie<br />

z wymogami zamieszczonymi na stronie:<br />

http://www.uph.edu.pl/index.php/druki-firmowe/dokumenty-wydawnictwa-ap.html<br />

http://dach.ich.uph.edu.pl/pl/_cs.html<br />

http://dach.ich.uph.edu.pl/download/cam_sep/<strong>CamSep</strong>_ww.pdf<br />

Wzory i rysunki należy sformatować jako obiekty wyśrodkowane<br />

przenoszone z tekstem. Wzory napisane w edytorze równań należy<br />

traktować jako element zdania np.:<br />

V<br />

t<br />

F<br />

R R<br />

(1)<br />

gdzie:<br />

V R – objętość retencji,<br />

t R – czas retencji [min.],<br />

F – przepływ gazu nośnego [cm 3 /s].<br />

Symbole użyte we wzorach powinny mieć rozmiar zgodny z<br />

rozmiarem czcionki tekstu rozdziału. Wzory należy numerować kolejno w<br />

całym tekście artykułu. Numery wzorów powinny być wyrównane do prawej.<br />

Oznaczenia stosowane na rysunkach i w tabelach muszą być czytelne i<br />

zgodne z oznaczeniami używanymi we wzorach i w tekście artykułu. Nazwy<br />

związków chemicznych stosować zgodnie z nomenklaturą IUPAC, jednostki<br />

z układu SI.<br />

W odpowiednie miejsca w tekście należy wstawić rysunki i tabele wraz<br />

z tytułami. Powinny one znajdować się w miejscach, w których po raz<br />

pierwszy są do nich odwołania w tekście artykułu. Rysunki i zdjęcia<br />

zamieszczone w artykule muszą być czytelne i kontrastowe oraz zapisane<br />

jako czarno-białe lub w skali odcieni szarości.<br />

Rysunki i tabele należy numerować kolejno w całym tekście artykułu<br />

(Rys. i Tab. nr arabskie).<br />

Tytuły rysunków i tabel należy podać w języku polskim i angielskim<br />

(kursywą) jak na przykładzie przedstawionym poniżej:<br />

Vol. 4, No 1/2012<br />

Camera Separatoria


174 Instrukcje dla autorów<br />

Tabela 1. Całkowita emisja metali z obszaru Polski według rodzajów<br />

działalności. Arial 10 pkt.<br />

Table 1. Total emission of heavy metals in the area of Poland kinds of<br />

activities. Arial 10 pkt.<br />

Ogółem<br />

(Total)<br />

Elektrociepłownie, elektrownie,<br />

ciepłownie<br />

(Heat and power plants, power<br />

stations)<br />

Cd Pb Cu Zn Ni<br />

tony<br />

66,1 555,0 390,9 2345,1 295,8<br />

1,9 19,9 12,8 59,2 72,2<br />

Tabele w pionie nie mogą przekraczać szerokości 12 cm, a w poziomie – 18<br />

cm. Czcionka wewnątrz tabeli – Arial 8 pkt.<br />

Rysunek, wykres, czy inna forma materiału ilustracyjnego nie może<br />

przekraczać w pionie – szerokości 12 cm, wysokości 18 cm; w poziomie –<br />

szer. – 18 cm, wysokości – 9÷10 cm (na stronie musi zmieścić się jeszcze<br />

podpis do rysunku). Materiał ilustracyjny powinien być zapisany z<br />

rozszerzeniem JPG i przesłany dodatkowo w oddzielnych plikach<br />

podpisanych, jako Rys.1., Rys. 2. itd.<br />

Rys. 1. Tytuł rysunku w języku polskim, Arial 8 pkt.<br />

Fig. 1. Tytuł rysunku w języku angielskim, Arial 8 pkt.<br />

Literatura<br />

(w tekście numerujemy w kolejności cytowania [1], [2, 3], [4-8] itd., - Arial 10<br />

pkt.):<br />

1. L.E. Green, J.C. Worman, Research of separation…, Anal. Chem.,<br />

37(1965)1620.<br />

Oprócz danych bibliograficznych należy zamieścić tytuł, w tym także<br />

publikacji, materiału z internetu, opisu patentowego itp. Tytuł w j.<br />

polskim, lub innym, niż język polskim jest pisany zwykłym drukiem w<br />

cudzysłowie, tytuł w języku angielskim – kursywą.<br />

Vol. 4, No 1/2012<br />

Camera Separatoria


Instrukcje dla autorów<br />

175<br />

2. T. Paryjczak, „Chromatografia gazowa…”, tłumaczenie tytułu na j.<br />

angielski kursywą, PWN, Warszawa 1986.<br />

(w przypadku, gdy tytuł pracy jest w innym języku, niż po angielsku, należy<br />

tytuł oryginalny napisać w języku oryginału, a następnie jego tłumaczenie na<br />

język angielski - kursywą)<br />

Wszystkie materiały:<br />

artykuł (w formacie .doc lub .rtf),<br />

dodatkowo zdjęcia i rysunki (w formacie JPG),<br />

prosimy przesyłać w formie plików, w jednej wiadomości na adres e-mail:<br />

psc1@onet.eu<br />

* * *<br />

Przesłany artykuł do <strong>CamSep</strong> podlega wstępnej ocenie przez Edytora,<br />

następnie przekazywany jest dwóm recenzentom do oceny. Recenzenci<br />

pozostają anonimowi.<br />

O przyjęciu artykułu do druku decyduje redakcja, w oparciu o<br />

przygotowaną recenzję. Jeśli w jej wyniku zachodzi konieczność<br />

poprawienia artykułu przez autora, to powinno to nastąpić w okresie nie<br />

dłuższym niż trzy tygodnie. Po tym terminie uważa się, że autor rezygnuje z<br />

publikacji lub gdy artykuł zostanie przesłany do redakcji podlegać on będzie<br />

ponownej ocenie.<br />

Po opublikowaniu autorzy bezpłatnie otrzymują elektroniczna wersję<br />

artykułu i właściwy nr <strong>CamSep</strong> jako egzemplarz autorski.<br />

Ogłoszenia/reklamy mogą być publikowane za odpowiednią,<br />

wcześniej ustaloną, opłatą.<br />

Przepisy etyczne<br />

Ważne jest, aby uzgodnić standardy etycznych zachowań dla<br />

wszystkich zaangażowanych w działania publikacji: autora, redaktora<br />

czasopisma, recenzenta, wydawcy i społeczeństwa czasopism. Redaktorzy i<br />

recenzent są zobowiązani do zapewnienia, że reklama, przedruk lub inny<br />

przychód komercyjny, nie ma wpływu na decyzje redakcyjne. Nie mogą oni<br />

ujawniać żadnych informacji na temat przedstawionego rękopisu do<br />

kogokolwiek innego niż autora artykułu. Niepublikowane materiały,<br />

ujawnione w przedstawionej pracy, nie mogą być używane przez<br />

redaktorów/recenzentów, jako część własnych badań bez pisemnej zgody<br />

autora. Powielanie lub adaptacja opublikowany wcześniej tabel, rycin,<br />

ilustracji lub obszernych cytatów z innych źródeł, akceptowana jest tylko za<br />

posiadaniem odpowiedniej pisemnej zgody autora.<br />

Vol. 4, No 1/2012<br />

Camera Separatoria


176 Instrukcje dla autorów<br />

Instructions for Authors and Editorial Policy<br />

Camera Separatoria is a scholarly and peer-reviewed journal (print<br />

and online) published 2 times per year which was founded in 2009. It is a<br />

continuation of the journal Postępy Chromatografii (Progress in<br />

Chromatography) devoted to the science, technique and technology of<br />

separation. It provides a medium for the publication of theoretical and<br />

experimental studies and reviews related to separation science:<br />

chromatography, electrophoresis, mass spectrometry, exctraction,<br />

electroseparation etc.<br />

Camera Separatoria publishes original (not published previously and<br />

are not currently under consideration by another journal except in the form of<br />

an abstract or as part of a published lecture, review, or thesis) and review<br />

papers from all branches of separation science, technique and technology.<br />

Additionally letters to the editor; expert opinions; information on<br />

instrumentation, book reviews and information about conferences as well as<br />

advertisements are also published. The journal welcomes contributions<br />

which promote the exchange of ideas and rational discourse between<br />

practicing educators and material researchers all over the world.<br />

The manuscript can be submitted to any editor, together with the<br />

cover letter, using e-mail. No limitation of the articles lengths are provided.<br />

The manuscript should be original, has not been published previously and<br />

should not be currently being considered by another journal.<br />

The manuscript can be submitted to any editor, together with the<br />

cover letter, using e-mail. No limitation of the articles lengths are provided.<br />

Manuscript should be prepared using MS-Word editor in the<br />

.doc/.docx format. Detailed rules are presented on<br />

http://www.uph.edu.pl/index.php/druki-firmowe/dokumenty-wydawnictwa-ap.html. It<br />

should be typed in single-spaced lines using Arial 10p. font with the overall<br />

page numbering (at the center of bottom margins). Tables (Arabic<br />

numeration, title in Polish and English, Arial 10p.), figures and figure<br />

captions (Arabic numeration, in Polish and English, Arial 8p.) and<br />

references can be placed directly to the text. The main heading appears in<br />

the following order:<br />

- list of Authors by first, middle names, surname (capital letters); the<br />

Corresponding Author’s name should be accompanied by an asterisk (*); if<br />

Authors are from more than one affiliation, use superscript numbers to link<br />

the Authors’ names and their affiliations,<br />

- list of affiliations and complete mailing addresses of the authors (including<br />

zip code, city, street, and number; for universities, the faculty or<br />

department should be given),<br />

- the title (should not exceed 20 words) of the article in Polish as well as<br />

English, (in all capital letters, Arial 12p.),<br />

- if there is more than one affiliation, use asterisks to indicate the institute<br />

with which each author is affiliated,<br />

as it is presented below:<br />

Vol. 4, No 1/2012<br />

Camera Separatoria


Instrukcje dla autorów<br />

177<br />

Jan K. KOWALSKI, Karol ROBERT*<br />

Department of Separation Science, Institute of Chemistry<br />

ul. 1 Maja 3, 00-000 Warszawa<br />

*e-mail: camera@separatoria.eu<br />

I Podlaskie Spotkanie Chromatograficzne<br />

1 st Podlasie’s Chromatographic Meeting<br />

Body text…<br />

In the subsequent text, the following parts are is desirable: abstract (in<br />

Polish and English, Arial 8p.), keywords (about five, in Polish and English,<br />

Arial 8p.), introduction (review of literature and formulation the aim of the<br />

paper), experimental (reagents, apparatus, protocols, data analysis), results<br />

and discussion, conclusions, acknowledgments and literature. The SI units<br />

and nomenclature recommended by IUPAC should be used. References<br />

should be typed in the forms:<br />

1. J.K. Kowalski, K. Robert, Research of separation…, J. Sep. Sci.,<br />

44(2000)666.<br />

2. A. Adzik, in Fundamentals of Separation Science, K. Karol, ed., PTNoR,<br />

Reymontówka 2000.<br />

3. Polish standard PN – EN ISO 17993, text…<br />

4. S. Separator, Proceedings of 2 nd Podlachia’s Chromatographic Meeting,<br />

Kotuń-Chlewiska, Sep. 12-18, 1987.<br />

in a list at the end of article and numbered in the order of appearance.<br />

Citation in the text should be denoted by number in square brackets.<br />

One of the Editor first evaluates the manuscript. Exceptionally it can<br />

be accepted at this stage. Those rejected at this stage are passed on to 2<br />

experts for review. Acceptance for publication is subject to positive<br />

recommendation from the referees. The referees remains anonymous<br />

throughout the process. Reviewers are not supposed to contact the authors<br />

or to otherwise make their identity known. The referees are asked to<br />

evaluate the manuscript according to the below rules within 3 weeks.<br />

Authors have three months to correct the article after the reviewing process.<br />

After this time, the returned article is considered as newly received. The<br />

authors receive the electronic version of their paper and the proper volume<br />

of Camera Separatoria free of charge.<br />

Advertisements may be published according to the prescribed rates.<br />

Ethical guidelines<br />

* * *<br />

It is crucial to agree upon standards of expected ethical behavior for<br />

all involved in the act of publishing: author, editor, reviewer, publisher and<br />

Vol. 4, No 1/2012<br />

Camera Separatoria


178 Instrukcje dla autorów<br />

society. Editors and reviewer are committed to ensuring that advertising,<br />

reprint or other commercial revenue has no impact or influence on editorial<br />

decisions. They must not disclose any information about a submitted<br />

manuscript to anyone other than the corresponding author. The unpublished<br />

materials disclosed in a submitted manuscript must not be used in an<br />

editor's/referee’s own research without the express written consent of the<br />

author. The reproduction or adaptation of previously published tables,<br />

figures, illustrations, or extensive quotations from other sources must obtain<br />

appropriate written permission.<br />

Vol. 4, No 1/2012<br />

Camera Separatoria


Instrukcje dla autorów<br />

179<br />

Vol. 4, No 1/2012<br />

Camera Separatoria

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!