13.07.2015 Views

SILHOUETTE 15 XL2 - Armstrong

SILHOUETTE 15 XL2 - Armstrong

SILHOUETTE 15 XL2 - Armstrong

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Design OptionsSilhouette <strong>15</strong> XL 2- Pre-mitred intersections- Choice of either 6 or 3 mm reveal dimension- Silhouette <strong>15</strong> XL 2 with 3 mm reveal is supplied asstandard in RAL 9010 white to compliment <strong>Armstrong</strong> metal tilesPerimeter Solutions<strong>SILHOUETTE</strong> <strong>15</strong> XL 2SectionCross Tee trimmed to wall angleView of mitred intersection from beneathSection8424Cross Tee trimmed to shadowlineT <strong>15</strong>08 HB at perimeterMCC4 GMitre closure clip for 6 mm revealAxiom Profiles(50, 100, 112, <strong>15</strong>0 and 200 mm heights available)Silhouette <strong>15</strong> XL 2 systemA 339 GAxiom universal T bar connector clipGrid Load CapacitySilhouette <strong>15</strong> XL 2 SystemThe following table gives the maximum permitted hanger distance (mm) along the Silhouette Main Runner (80 40 42 G) for the tile weights and Main Runner spacings noted.Tile weight Main Runner spacing 1200 mm1200 mm XL 2 Cross Tee80 30 42 G2,5 kg/m 218003,0 kg/m 170023,5 kg/m 165024,0 kg/m 160025,0 kg/m <strong>15</strong>0025,5 kg/m 145026,0 kg/m 140027,0 kg/m 130028,5 kg/m 1200210,5 kg/m 1100213,0 kg/m 9502Hanger spacingAvailability of products may vary according to location.Please contact our <strong>Armstrong</strong> Technical Sales for further details.Main Runner spacing 600 mm600 mm XL 2 Cross Tee80 20 42 G210021002050200019001850180017001600<strong>15</strong>5013501) Values in the above table conform to Class 1 as defined in EN13964:2004+A1:2006 table 6.For other classes /deflection limits please contact your local <strong>Armstrong</strong>Technical Sales.2) Values are determined from laboratory tests methods in accordance withEN 13964:2004+A1:2006 clause 5.3) Values are applicable for 600 x 600 mm tiles assuming that the maximumdeflection of the grid is L/500 but not greater than 4 mm (L = span).4) No other applied loads such as luminaires, air diffusers, smokedetectors, sprinklers, hanging signs etc. are permitted.5) No overlays such as mineral wool or fibre glass quilts, as may be required forenhanced acoustic, fire or thermal performance, are permitted unless their fullweight is established and included, together with the weight of the tile, withinthe appropriate weight groups.6) For grid loading data calculated to different criteria than Class 1 toEN13964:2004+A1:2006, please contact your local <strong>Armstrong</strong> TechnicalSales team.CENTRAL EUROPE NORTH(DK/EE/FIN/IS/LT/LV/N/PL/S)<strong>Armstrong</strong> Building Products B.V.Sp. z o.o. Oddział w PolsceUl. Domaniewska 3702-672 WarszawaPolandTel. : (+48) 22 337 86 10 / 86 11Fax : (+48) 22 337 86 12e-mail : service-ce@armstrong.comLatvia : www.armstrong.lvLithuania : www.armstrong.ltNorway : www.armstrong.noPoland : www.armstrong.plSweden : www.armstrong.se

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!