[38] A. F. Fercher, “OPTICAL COHERENCE TOMOGRAPHY,” Journal ofBiomedical Optics, 1(2), 157-173 (1996).[39] E. A. Swanson, D. Huang, M. R. Hee et al., “High-speed optical coherencedomain reflectometry: erratum,” Opt. Lett., 17(7), 547-547 (1992).[40] B. E. Bouma, and G. J. Tearney, “Handbook of Optical CoherenceTomography,” Informa Healthcare, (2001).[41] A. F. Fercher, C. K. Hitzenberger, W. Drexler et al., “In vivo optical coherencetomography,” American Journal of Ophthalmology, 116(1), 113-114 (1993).[42] P. N. T. Wells, “The medical applications of ultrasonics,” Reports on Progress inPhysics, 33(1), 45 (1970).[43] A. M. Rollins, and J. A. Izatt, “Optimal interferometer designs for opticalcoherence tomography,” Opt. Lett., 24(21), 1484-1486 (1999).[44] B. Liu, and M. E. Brezinski, “Theoretical and practical considerations ondetection performance of time domain, Fourier domain, and swept source opticalcoherence tomography,” J Biomed Opt, 12(4), 044007 (2007).[45] R. Leitgeb, C. Hitzenberger, and A. Fercher, “Performance of fourier domain vs.time domain optical coherence tomography,” Opt. Express, 11(8), 889-894(2003).[46] M. Choma, M. Sarunic, C. Yang et al., “Sensitivity advantage of swept sourceand Fourier domain optical coherence tomography,” Opt. Express, 11(18), 2183-2189 (2003).[47] J. F. de Boer, B. Cense, B. H. Park et al., “Improved signal-to-noise ratio inspectral-domain compared with time-domain optical coherence tomography,”Opt. Lett., 28(21), 2067-2069 (2003).[48] M. Wojtkowski, “High-speed optical coherence tomography: basics andapplications,” Appl. Opt., 49(16), D30-D61.[49] B. E. A. Saleh, and M. C. Teich, “Fundamentals of Photonics,” Wiley Series inPure and Applied Optics, (1991).[50] M. A. Parker, “Physics of Optoelectronics,” Taylor & Francis, (2005).[51] B. E. Saleh, and M. Teich, “Fundamentals of Photonics,” Wiley, (1991).[52] B. Bouma, and G. J. Tearney, “Handbook of Optical Coherence Tomography,”Taylor & Francis, (2001).[53] M. A. Choma, C. Yang, and J. A. Izatt, “Instantaneous quadrature lowcoherenceinterferometry with 3×3 fiber-optic couplers,” Opt. Lett., 28(22),2162-2164 (2003).[54] M. Wojtkowski, A. Kowalczyk, R. Leitgeb et al., “Full range complex spectraloptical coherence tomography technique in eye imaging,” Opt. Lett., 27(16),1415-1417 (2002).[55] P. Targowski, M. Wojtkowski, A. Kowalczyk et al., “Complex spectral OCT inhuman eye imagingin vivo,” Optics Communications, 229, 79-84 (2003).[56] T. Electronics, “M/A-COM Application Note #3027,” (www.macom.com).[57] F. Huang, W. Yang, and W. S. Warren, “Quadrature spectral interferometricdetection and pulse shaping,” Opt. Lett., 26(6), 382-384 (2001).[58] E. D. J. Smith, S. C. Moore, N. Wada et al., “Spectral domain interferometry forOCDR using non-Gaussian broadband sources,” IEEE Photon. Technol. Lett,13(1), 64-66 (2001).[59] A. G. Podoleanu, “Unbalanced versus balanced operation in an opticalcoherence tomography system,” Appl. Opt., 39(1), 173-182 (2000).[60] A. Bradu, and A. G. Podoleanu, “Fourier domain optical coherence tomographysystem with balance detection,” Opt. Express, 20(16), 17522-17538.122
[61] J.-S. Park, M.-Y. Jeong, and C.-S. Kim, “Post-tuning of Sample Position inCommon-path Swept-source Optical Coherence Tomography,” J. Opt. Soc.Korea, 15(4), 380-385.[62] C. Blatter, B. Grajciar, C. M. Eigenwillig et al., “Extended focus high-speedswept source OCT with self-reconstructive illumination,” Opt. Express, 19(13),12141-12155.[63] T. Klein, W. Wieser, C. M. Eigenwillig et al., “Megahertz OCT for ultrawidefieldretinal imaging with a 1050nm Fourier domain mode-locked laser,” Opt.Express, 19(4), 3044-3062.[64] P. Meemon, and J. P. Rolland, “Swept-source based, single-shot, multidetectablevelocity range Doppler optical coherence tomography,” Biomed. Opt.Express, 1(3), 955-966.[65] B. Potsaid, B. Baumann, D. Huang et al., “Ultrahigh speed 1050nm sweptsource / Fourier domain OCT retinal and anterior segment imaging at 100,000 to400,000 axial scans per second,” Opt. Express, 18(19), 20029-20048.[66] J. W. Goodman, “Statistical optics,” Wiley, (2000).[67] Y. Chen, D. M. de Bruin, C. Kerbage et al., “Spectrally balanced detection foroptical frequency domain imaging,” Opt. Express, 15(25), 16390-16399 (2007).[68] C. C. Rosa, and A. G. Podoleanu, “Limitation of the Achievable Signal-to-NoiseRatio in Optical Coherence Tomography Due to Mismatch of the BalancedReceiver,” Appl. Opt., 43(25), 4802-4815 (2004).[69] C. E. Shannon, “Communication in the presence of noise,” Proc. Institute ofRadio Engineers, 37(1), 10-21 (1949).[70] T. Bajraszewski, M. Wojtkowski, M. Szkulmowski et al., “Improved spectraloptical coherence tomography using optical frequency comb,” Opt. Express,16(6), 4163-4176 (2008).[71] V. M. Gelikonov, G. V. Gelikonov, and P. A. Shilyagin, “Linear-wavenumberspectrometer for high-speed spectral-domain optical coherence tomography,”Optics and Spectroscopy, 106(3), 459-465.[72] Y. Watanabe, and T. Itagaki, “Real-time display on SD-OCT using a linear-inwavenumberspectrometer and a graphics processing unit,” Proceedings of theSPIE, 7554, (2010).[73] Z. Hu, and A. M. Rollins, “Fourier domain optical coherence tomography with alinear-in-wavenumber spectrometer,” Opt. Lett., 32(24), 3525-3527 (2007).[74] N. Zhang, T. Chen, C. Wang et al., “Spectral-domain optical coherencetomography with a Fresnel spectrometer,” Opt. Lett., 37(8), 1307-1309.[75] C. M. Eigenwillig, B. R. Biedermann, G. Palte et al., “K-space linear Fourierdomain mode locked laser and applications for optical coherence tomography,”Opt. Express, 16(12), 8916-8937 (2008).[76] Y. Yasuno, V. D. Madjarova, S. Makita et al., “Three-dimensional and highspeedswept-source optical coherence tomography for in vivo investigation ofhuman anterior eye segments,” Opt. Express, 13(26), 10652-10664 (2005).[77] W. Kai, G. Huang, Z. H. Ding et al., [High-speed spectral-domain opticalcoherence tomography at 830nm wavelength] Spie-Int Soc Optical Engineering,Bellingham(2008).[78] I. V. Larina, N. Sudheendran, M. Ghosn et al., “Live imaging of blood flow inmammalian embryos using Doppler swept-source optical coherencetomography,” JBO Letters, (2008).123
- Page 1 and 2:
WYDZIAŁ FIZYKI, ASTRONOMIIIINFORMA
- Page 3 and 4:
Spis treści1. WSTĘP .............
- Page 6 and 7:
typowe rozdzielczości odpowiednio
- Page 8 and 9:
pojedynczej linii zwiększono do 13
- Page 10 and 11:
c) zwiększone wnikanie wiązki ska
- Page 12 and 13:
2. TEORIATomografia optyczna OCT z
- Page 14 and 15:
óżnice jakie pojawiają się ze w
- Page 16 and 17:
powracającego z ramienia referency
- Page 18 and 19:
(2.6)gdzie Γ(z) jest funkcją kohe
- Page 20 and 21:
mieszczącej się w zakresie obrazo
- Page 22 and 23:
gdzie, i DC oznacza średni fotopr
- Page 24 and 25:
tłumienie wpływu względnego szum
- Page 26 and 27:
(2.20)Powyższa zależność ma pos
- Page 28 and 29:
i OCT z użycie laserów strojonych
- Page 30:
Jeśli użyjemy jednocześnie obu k
- Page 33 and 34:
Rys. 2. 7 Efekt skrócenia zakresu
- Page 35 and 36:
kwadratu mocy wejściowej. Dodatkow
- Page 37 and 38:
W rezultacie w obu metodach fourier
- Page 39 and 40:
Uwzględniając zmianę położenia
- Page 41 and 42:
najpowszechniejszym obiektem badań
- Page 43 and 44:
Rys. 2. 11 Symulacja średnicy plam
- Page 45 and 46:
2.3. ŚWIATŁOWODOWY LASER STROJONY
- Page 47 and 48:
wzmocnienie w różnych zakresach d
- Page 49 and 50:
(2.56)gdzie η jest wydajnością k
- Page 51 and 52:
Szerokość połówkową piku inter
- Page 53 and 54:
zędu nawet kilku kilometrów (patr
- Page 55 and 56:
Rys. 2. 16 Schemat budowy wnęki re
- Page 57 and 58:
ograniczenia związanego z częstot
- Page 59 and 60:
3. UKŁAD EKSPERYMENTALNYOpisana w
- Page 61 and 62:
pompowania towarzyszy także wzrost
- Page 63 and 64:
Rys. 3. 5 Funkcja transmisji filtra
- Page 65 and 66:
często stosuje się sygnał steruj
- Page 67 and 68:
3.1.3. ŚWIATŁOWODOWA PĘTLA OPÓ
- Page 69 and 70:
światłowodowych, każdorazowo prz
- Page 71 and 72: Warto zauważyć, że dla drugiej z
- Page 73 and 74: Warto zauważyć, że stosowanie sp
- Page 75 and 76: Rys. 3. 14 Moc wyjściowa lasera st
- Page 77 and 78: Tabela 3 Szerokość połówkowa
- Page 79 and 80: Rys. 3. 18 Spadki czułości w funk
- Page 81 and 82: Rys. 3. 20 Krzywe spadku czułości
- Page 83 and 84: światła padającego na kanał uje
- Page 85 and 86: 3.2.2. INTERFEROMETR KALIBRACYJNYW
- Page 87 and 88: przypadających na jeden A-scan, a
- Page 89 and 90: częstotliwość obiegu przez wnęk
- Page 91 and 92: OCT wymaga albo czasochłonnej prze
- Page 93 and 94: Sekwencja pomiarów trójwymiarowyc
- Page 95 and 96: Rys. 4. 7 Przekroje poprzeczne prze
- Page 97 and 98: ssOCT Oculus PantacamPrzeszczep rog
- Page 99 and 100: powierzchni rogówki. Na podstawie
- Page 101 and 102: Rys. 4. 13 Przykład M-skanu genero
- Page 103 and 104: Rys. 4. 15 Krzywe histerezy odpowia
- Page 105 and 106: strojonego, pozwoliły na lepsze zr
- Page 107 and 108: 7. DODATEK BUzupełniający materia
- Page 109 and 110: Zespolona wartość pola padająceg
- Page 111 and 112: C.7[D1_2] człon drugi dotyczący w
- Page 113 and 114: Wprowadza się widmową gęstość
- Page 115 and 116: Ponownie korzystamy ze wzorów Eule
- Page 117 and 118: =W układzie z idealną detekcją r
- Page 119 and 120: Rys. D. 2 Schemat ideowy układu st
- Page 121: [21] R. Huber, M. Wojtkowski, J. G.
- Page 125 and 126: [97] Y. Nakazaki, and S. Yamashita,
- Page 127 and 128: [135] M. W. Belin, and S. S. Khachi
- Page 129 and 130: 2. Wykonawca grantu: NCBiR-LIDER-85
- Page 131 and 132: Pełne artykuły w materiałach kon