6.2. feed valves<br />

Before doing any boiler control, the boiler must be out of service. If steam plant has more boilers then boiler in question must be<br />

isolated from fuel and steam.<br />

Talk with engineers about procedures for inner and outer inspection of the boiler, important items which have to be discussed about<br />

are:<br />

– deposits on the heating surfaces which reduce heat transfer causing burning of the pipe sometimes<br />

– corrosion occurrence<br />

– wear or damage of the boiler armature (cocks, valves, safety valves, level indicators etc.)<br />

– generally condition of the surfaces where hot gases are passing through.<br />

If the boiler is in service from time to time, it is possible that safety valve is not inspected. But during periodical inspection and<br />

cleaning valves have to be opened and inspected. Safety valve must be checked on the proper releasing pressure by authorised<br />

surveyor. The mechanism for manual pressure release must be also checked. Check all passings on the level indicators and blow<br />

them with compressed air if necessary.<br />

13. ELECTRICAL DISTRIBUTION SYSTEM AND HIS MAINTENANCE<br />

TASKS<br />

SERIAL<br />

NUMBER<br />

OF THE<br />

SHIP<br />

DATE<br />

TASK DONE<br />

DUTY<br />

OFFICER<br />

CHIEF ENG.<br />

SIGNATURE<br />

REMARKS<br />

1. Make drawings of electrical<br />

distribution from generator to<br />

last user, marking:<br />

– breakers<br />

– switches<br />

– trafos<br />

– fuses<br />

– feed voltage<br />

– shore connection<br />

– emergency switchboard<br />

2. Isolate and turn off generator,<br />

and take all precautions<br />

3. Make routine test and<br />

maintenance of:<br />

3.1. breakers<br />

3.2. motor starters<br />

3.3. revolution counter<br />

3.4. electrical motor<br />

3.5. generators<br />

3.6. lighting<br />

3.7. battery<br />

3.8. alarms<br />

Isolate power circuit, block it and<br />

put some warning, record it in