185<br />

colour<br />

– excessive air by reading<br />

CO 2 /CO<br />

14. Treat the feed water<br />

Make routine test of:<br />

14.1. boiler water<br />

14.2. feed water<br />

15. Treat the feed water<br />

according to test and duty<br />

engineer instructions<br />

16. Control the condensate<br />

coming from heating coils<br />

and other heaters<br />

17. Control the work of all<br />

indicators and alarms<br />

related to boiler<br />

18. Control the feed water<br />

system, and water levels<br />

19. Make soot blowing<br />

Before starting steam system (piping or engine), all spaces must be dry properly warmed. The system must be drained before use,<br />

and steam releasing very slow in the beginning. Very small steam quantity in the beginning will push condensate through drain<br />

system and heat all system as well.<br />

When we have working temperature and all system is drained main stop valve can be open easily. Water in the system is product of<br />

condensation, especially on the cold surfaces. The water can not be compressed. When the steam enters the system, steam is<br />

condensate so the mixture activate in the very low pressure (high vacuum). Water enters vacuum spaces very quickly what can<br />

cause damage. That phenomenon is called »water hammer«.<br />

Piping changes length during temperature change, so the compensators must be checked.<br />

Anyhow steam releasing must be done very slowly.<br />

12. MAINTENANCE OF THE AUXILIARY BOILERS<br />

TASKS<br />

SERIAL<br />

NUMBER<br />

OF THE<br />

SHIP<br />

DATE<br />

TASK DONE<br />

DUTY<br />

OFFICER<br />

CHIEF ENG.<br />

SIGNATURE<br />

REMARKS<br />

1. Put the boiler out of service<br />

2. Drain out the boiler water<br />

3. Open the boiler<br />

4. Inspect the boiler, make<br />

report of:<br />

4.1. boiler inside<br />

4.2. boiler outside<br />

5. Dismantle level indicators<br />

and connections, control cocks<br />

and valves<br />

6. Open and inspect:<br />

6.1. safety valves