10.11.2014 Views

Vrtložna merila protoka

Vrtložna merila protoka

Vrtložna merila protoka

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Mass flowmeters<br />

39<br />

High Visok degree stepen tačnosti of measurement merenja, čak i pri<br />

accuracy uslovima brzih – even promena for rapidly temperature changing<br />

temperatures medijuma, ili vrste and fluida media. koji se meri<br />

Just Preciznost how precisely i pouzdanost and rada reliably masenih a mass <strong>merila</strong> flowmeter <strong>protoka</strong>, really mogu se utvrditi<br />

works u slučajevima is only kada evident se parametri when constant medijuma, parameters kao što je such temperatura as ili<br />

the gustina, medium, naglo temperature promene. OPTIMASS or density porodica abruptly masenih change. <strong>merila</strong> The KROHNE<br />

postavlja nove standarde za ovakve slučajeve.<br />

OPTIMASS family from KROHNE sets the standards in this<br />

regard as well:<br />

Svi OPTIMASS senzori imaju osnovnu obradu signala postavljenu<br />

With direktno the na new senzoru. sensor-oriented Taj elektronski preprocessing sklop predstavlja electronics osnov brze i<br />

package, visokoprecizne which analize is used dobijenih for all OPTIMASS signala, što omogućuje sensors, the ostvarenje analog<br />

izvanrednih<br />

signal processing<br />

mernih karakteristika.<br />

takes place<br />

Čak<br />

directly<br />

i za vrlo<br />

at<br />

visoke<br />

the sensor:<br />

protoke,<br />

the<br />

sa naglim<br />

promenama temperature i skokovima viskoziteta medijuma, elektronski<br />

basis for quick and highly precise signal analysis – and excellent<br />

measuring performance. The result: even for very<br />

paket pokazuje neosetljivost na navedene uticaje, te da prati protok brzo<br />

i tačno.<br />

high flowrates, with changes in the medium and temperature<br />

or with density jumps, the electronics package has<br />

demonstrated Čuvanje svih parametara that it is not uređaja susceptible i kalibracionih to these podataka influences osigurano<br />

and<br />

je na<br />

it<br />

dva<br />

follows<br />

načina:<br />

the<br />

memorisanjem<br />

flow very quickly<br />

u elektronici<br />

and accurately.<br />

senzora, i u mernom<br />

pretvaraču. Zbog toga nije potrebno ponovno podešavanje parametara<br />

ukoliko, iz bilo kojeg razloga, dođe do zamene mernog pretvarača ili<br />

The storing of all device parameters and calibration data<br />

senzora.<br />

is doubly secure. It is done once in the sensor electronics<br />

itself and once in the measurement transducer. Therefore,<br />

no re-parameterization is required after a measurement<br />

transducer or sensor is swapped.<br />

Industries<br />

Industrije:<br />

• Hemijska<br />

» Chemical<br />

»<br />

• Farmaceutska<br />

Pharmaceuticals<br />

»• Prehrambena<br />

Food<br />

»• Nafta Oil and i gas gas<br />

» Petrochemical<br />

• Petrohemijska<br />

» Paper and pulp<br />

• Papir i papirna pulpa<br />

» Mining and minerals<br />

• Rudarstvo i prerada minerala<br />

» Power Plants<br />

• Termoelektrane<br />

» Water and wastewater<br />

• Vode i otpadne vode<br />

OPTIMASS in the dosing process at Jass

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!