Tehniline andmeleht <strong>Sadulventiilid</strong> <strong>VF</strong> 2, <strong>VL</strong> 2 - 2-tee; <strong>VF</strong> 3, <strong>VL</strong> 3 - 3-tee<br />
Tellimine (järg))<br />
Lisaseadmed - AMV/AME spindli soojendi<br />
Tüüp<br />
Spindli soojendi 24 V (AMV/AME 15, 16,<br />
25, 35 ja ventiilid DN 15 - 50)<br />
Spindli soojendi 24 V (AMV/AME 55, 56<br />
ja ventiilid DN 65 - 100)<br />
Spindli soojendi 24 V (AMV/AME 55 ja<br />
vent iilid DN 125, 150)<br />
Spindli soojendi 24 V (AMV/AME 85, 86<br />
ja ventiilid DN 125, 150)<br />
Code No.<br />
065B2171<br />
065Z7020<br />
065Z7022<br />
065Z7021<br />
Varuosad - tihenduskarp<br />
Mõõtmed<br />
Ventiilid<br />
Kood<br />
DN<br />
<strong>VL</strong> 2 / <strong>VL</strong> 3 <strong>VF</strong> 2 / <strong>VF</strong> 3<br />
15<br />
20<br />
25<br />
32<br />
065B0008 1) 065B0008 1)<br />
Märkus:<br />
1)<br />
Tihenduskarp<br />
Rõngastihend<br />
Juhised<br />
2)<br />
Kolm PFTE rõngast<br />
Rõngastihend<br />
Juhised<br />
40<br />
50<br />
65<br />
80<br />
100<br />
125<br />
150<br />
065B1360 1)<br />
065B1360 1)<br />
- 065B0007 2)<br />
Tehnilised andmed Nimirõhk PN 16 (<strong>VF</strong>); PN 6 (<strong>VL</strong>)<br />
Reguleerimiskarakteristik<br />
LOG - port A-AB; LIN - port B-AB<br />
Soojuskandja Tsirkulatsiooni vesi / vesi-glükool kuni 50 %<br />
Soojuskandja temp. <strong>VL</strong> 2, <strong>VL</strong> 3: 2 (-10* ) ... 120 °C<br />
<strong>VF</strong> 2, <strong>VF</strong> 3 DN 15 - 100: 2 (-10* ) ... 130 °C<br />
<strong>VF</strong> 2, <strong>VF</strong> 3 DN 125 and 150: 2 (-10* ) ... 200 °C<br />
Lekkekadu<br />
0,05 % k VS<br />
Reguleerimisvahemik k VS 0,63: min. 30:1 / k VS 1,0 - 4.0: min. 50:1 / DN 20 - DN 150: min. 100:1<br />
Ühendus Äärik ISO 7005-2<br />
* Temperatuuril -10 ºC kuni +2 ºC on vajalik spindli soojendi.<br />
Materjalid:<br />
<strong>VF</strong> 2 / <strong>VF</strong> 3 / <strong>VL</strong> 2 / <strong>VL</strong> 3 (DN 15 - 100)<br />
Korpus Hall malm EN-GJL-250 (GG-25)<br />
Spindel Roostevaba teras<br />
Koonus - messing (DN15 – 65)<br />
- punane pronks 2.1096.1 (Rg5) (DN 80 - 100)<br />
Tihend EPDM<br />
<strong>VF</strong> 2 / <strong>VF</strong> 3 (DN 125 - 150)<br />
Korpus ja kaas<br />
Koonus GGG 40<br />
Sadul ja spindel<br />
Rõngastihend<br />
Kõrgtugev malm<br />
EN-GJS-400-18-LT (GGG 40.3)<br />
Roostevaba teras<br />
PTFE rõngad<br />
Lekkekadu suletud ventiili korral<br />
2 - tee ventiilid (A-AB) 1) Maks. 0,05% k VS<br />
1)<br />
3 - tee ventiilid<br />
(A-AB) 1)<br />
(B-AB)<br />
Maks. 0,05% k VS<br />
1)<br />
Maks. 1% k VS<br />
1) Lekkekadu ventiilides <strong>VF</strong>/<strong>VL</strong> DN 15 (kvs 0.63 - 2.5) on 0.1%<br />
Tihedus- ja rõhukatsetused vastavad standardile VDI/VDE 2174<br />
Rõhu / temperatuuri diagramm<br />
2 VD.HC.K2.26 © <strong>Danfoss</strong> 01/2009 DH-SMT/SI