Model:<br />

Frequency:<br />

Fuel Type:<br />

C22 D5<br />

50<br />

Diesel<br />

» Generator set data sheet<br />

22kVA Standby @ 50Hz<br />

Our energy working for you.<br />

Spec sheet:<br />

Noise data sheet (Open/enclosed):<br />

Airflow data sheet:<br />

Derate data sheet (Open/enclosed):<br />

Transient data sheet:<br />

SS2-CPGK<br />

ND50-OS550 / ND50-CS550<br />

AF50-550<br />

DD50-OS550 / DD50-CS550<br />

TD50-550<br />

Fuel consumption<br />

Ratings<br />

Load<br />

gph<br />

L/hr<br />

Standby<br />

Prime<br />

kVA (kW)<br />

kVA (kW)<br />

22 (17.6)<br />

20 (16)<br />

1/4 1/2 3/4 Full 1/4 1/2 3/4 Full<br />

0.3 0.6 0.9 1.2 0.3 0.6 0.8 1.1<br />

2 3 4 6 2 3 4 5<br />

Engine<br />

Engine manufacturer<br />

Engine model<br />

Configuration<br />

Aspiration<br />

Gross engine power output, kWm<br />

BMEP at set rated load, kPa<br />

Bore, mm<br />

Stroke, mm<br />

Rated speed, rpm<br />

Piston speed, m/s<br />

Compression ratio<br />

Lube oil capacity, L<br />

Overspeed limit, rpm<br />

Regenerative power, kW<br />

Governor type<br />

Starting voltage<br />

Standby rating<br />

Cummins<br />

4B3.3G1<br />

4 Cycle; In-line; 4 Cylinder Diesel<br />

Naturally Aspirated<br />

36<br />

876<br />

95<br />

115<br />

1500<br />

5.8<br />

18.2:1<br />

7<br />

1800 ±50<br />

3<br />

Mechanical<br />

12 Volts DC<br />

Prime rating<br />

32<br />

787<br />

Fuel flow<br />

Maximum fuel flow, L/hr<br />

Maximum fuel inlet restriction, mm Hg<br />

Maximum fuel inlet temperature (°C)<br />

12.5<br />

73<br />

60<br />

Air<br />

Combustion air, m 3 /min<br />

Maximum air cleaner restriction, kPa<br />

2.10<br />

6.2<br />

2.10<br />

©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and<br />

Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power<br />

Generation. Other company, product, or service names may be trademarks or service marks of others.