Parameterlista<br />
Parameter Alternativ Fabriksinställning<br />
SPRÅK SVE/ENG/FRA/TYS/SPA SVE<br />
MODELL TS 62, T 196, TS 92, FC 18 FC 18<br />
RESET JA -<br />
ENHET GRADER C/F C<br />
MIN TEMP [-- --], 25 -> [MED-5] 40<br />
MED TEMP [MIN + 5] -> [MAX-5] 60<br />
MAX TEMP [MED + 5]-90 80<br />
FÖRV TEMP MIN/MED/MAX MAX<br />
VISA GRADER AV/PÅ PÅ<br />
MAX TID 1:00-09:59 04:00<br />
FÖRV TID 0:00-[MAX TID] 01:30<br />
AUTOPROG AV, 1-9 3<br />
PR1 TEMP MIN/MED/MAX MAX<br />
PR1 HU STOP 0-99 4<br />
PR1 REAKTIV 0:00-1:00 00:30<br />
PR2 TEMP MIN/MED/MAX MAX<br />
PR2 HU STOP 0-99 6<br />
PR2 REAKTIV 0:00-1:00 00:30<br />
PR3 TEMP MIN/MED/MAX MED<br />
PR3 HU STOP 0-99 7<br />
PR3 REAKTIV 0:00-1:00 00:00<br />
HYST TEMP 0-20 10<br />
NEDKYLNING 0:00-0:20 00:15<br />
VISA TEMP+HU AV/PÅ AV<br />
VISA LOGO AV/PÅ PÅ<br />
LJUD AV/PÅ PÅ<br />
STANDBY AV/PÅ PÅ<br />
BELYSN TID 0:00-0:30 00:10<br />
PAUS TID 0:00-0:30 00:10<br />
BOKNSYSTEM AV/PÅ AV<br />
SIGNALTYP PLS/N-O N-O<br />
ARBETSTIMMAR - [000000] h<br />
TESTPROGRAM AV/PÅ AV<br />
RADERA E-KOD JA -<br />