608 P a r t V I I : T u n i n g , T r o u b l e s h o o t i n g , a n d D e s i g n A i d<br />

One of the latest designs in VSWR meter sensors is the current transformer assembly<br />

shown in Fig. 27.15. In this instrument, a single-Âturn ferrite toroid transformer is used<br />

as the directional sensor. The transmission line passing through the hole in the toroid<br />

forms the primary winding of a broadband RF transformer. The secondary, which consists<br />

of 10 to 40 turns of small enamel wire, is connected to a measurement bridge circuit<br />

(C 1 + C 2 + load) with a rectified dc output.<br />

Figures 27.16 and 27.17 show instruments that can be left in the transmission line for<br />

all amateur power levels. The upper unit in Fig. 27.16, from Diamond <strong>Antenna</strong>s, houses<br />

the transformer with the metering and control functions. The Kenwood wattmeter below<br />

it allows the user to Âfront-Âpanel select any of up to three separate companion transformer<br />

units, each capable of being located as much as 18 in from the meter enclosure.<br />

The Bird Model 43 Thruline RF wattmeter shown in Fig. 27.17 has for years been one<br />

of the industry standards in communications service work. Although it is slightly more<br />

expensive than other instruments, it is versatile and has a reputation for being accurate<br />

and rugged. The Thruline meter can be inserted into the transmission line of an antenna<br />

system with so little loss that it may be left permanently in the line during normal operations.<br />

The Model 43 Thruline is popular with land mobile and marine radio technicians.<br />

T 1<br />

J 1<br />

XMTR<br />

C 1<br />

10 pF<br />

Conductor<br />

D 1<br />

IN60<br />

D 2<br />

IN60<br />

C 2<br />

10 pF<br />

J 2<br />

ant<br />

C 3<br />

330 pF<br />

R 1<br />

68 k<br />

R 2<br />

68 k<br />

C 4<br />

330 pF<br />

L 1<br />

C 5<br />

0.001 F<br />

1 mH<br />

10 k<br />

cal<br />

S 1<br />

REV FWD<br />

10 k<br />

cal<br />

L2 1 mH<br />

C 6<br />

0.001 F<br />

S 2<br />

VSWR PWR<br />

C 7<br />

0.01 F<br />

M 1<br />

0–100 A<br />

Figure 27.15 Current transformer wattmeter.