Comunicari prezentate - IMNR
Comunicari prezentate - IMNR
Comunicari prezentate - IMNR
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>IMNR</strong><br />
MANUFACTURED NANOBIOMATERIALS - GOOD PRACTICE<br />
Roxana M. Piticescu,<br />
National R&D Institute for Non-ferrous and Rare Metals<br />
102 Biruintei Blvd., Pantelimon, Ilfov, Romania<br />
Multidisciplinary works try to answer to the ETP Nanomedicine<br />
questions:<br />
-What are the best materials to be used in regenerative medicine;<br />
-What are the appropriate cellular lines ;<br />
-Do we need new materials/new technologies;<br />
- What is the level of the research in the field of regenerative<br />
medicine: basic research and applicative research.<br />
Workshop <strong>IMNR</strong> 27 .02. 2008
nano<br />
prefix used to denote the presence of significant features existing or processes operating within the<br />
nanoscale<br />
nanomaterial<br />
material having one or more external dimensions in the nanoscale or which is nanostructured<br />
NOTE Nanomaterials can exhibit properties that differ from those of the same material without nanoscale<br />
features.<br />
nanoscale<br />
size range from approximately 1 nm to 100 nm<br />
NOTE 1 Properties that are not extrapolations from larger size will typically, but not exclusively, be exhibited<br />
in this size range. NOTE 2 The lower limit in this definition (approximately 1 nm) has no physical significance<br />
but is introduced to avoid single and small groups of atoms from being designated as nano-objects or<br />
elements of nanostructures, which might be implied by the absence of a lower limit. [ISO/TS 276871)]<br />
nanostructured<br />
possessing a structure comprising contiguous elements with one or more dimension in the nanoscale but<br />
excluding any primary atomic or molecular structure<br />
NOTE 1 An example of a primary atomic or molecular structure is the<br />
arrangement of atoms in a crystalline solid. NOTE 2 The use of the term contiguous implies that a sphere of<br />
approximately 100 nm diameter, inscribed in a nanostructured material, will intersect more than one element<br />
of the structure.<br />
Source: BSI/PAS 132<br />
DEFINITIONS<br />
Workshop <strong>IMNR</strong> 27 .02. 2008
PHYSICAL AND CHEMICAL CHARACTERISTICS OF NANOMATERIALS<br />
WITH A DEFINITE INFLUENCE ON PRODUCT PERFORMANCE<br />
Specifying manufactured<br />
nanomaterials having all three<br />
dimensions at the nanoscale, i.e.<br />
nanopowders<br />
• Particle size distribution.<br />
• Crystallite size distribution.<br />
• Degree of agglomeration.<br />
• Specific surface area.<br />
• Bulk chemical composition.<br />
• Particle morphology.<br />
• Flow characteristics.<br />
• Tap density; Apparent density.<br />
• Porosity.<br />
• Surface chemical composition.<br />
• Crystal structure.<br />
• Moisture content.<br />
• pH.<br />
• Colour.<br />
• Transparency.<br />
Specifying manufactured<br />
nanomaterials having two<br />
dimensions at the nanoscale – carbon<br />
nanotubes<br />
• Length distribution.<br />
• Diameter distribution.<br />
• Aspect ratio distribution.<br />
• Wall thickness.<br />
• Number of walls, i.e. single-walled, double-walled,<br />
or multi-walled.<br />
• Chemical purity – presence of catalyst.<br />
• Structural/Product purity – presence of other<br />
carbon-based materials.<br />
• Dispersibility.<br />
• Degree of agglomeration.<br />
• Surface chemical analysis.<br />
• Surface functionalization.<br />
• Structure at the ends, i.e. open or closed.<br />
Workshop <strong>IMNR</strong> 27 .02. 2008
PHYSICAL AND CHEMICAL CHARACTERISTICS OF NANOMATERIALS<br />
WITH A DEFINITE INFLUENCE ON PRODUCT PERFORMANCE<br />
Specifying other manufactured<br />
nanomaterials with two dimensions<br />
at the nanoscale, i.e. nanofibres and<br />
nanorods<br />
Specifying manufactured<br />
nanomaterials having only one<br />
dimension at the nanoscale, i.e.<br />
nanoscale thin films or coatings<br />
• Size distribution. Length distribution.<br />
• Diameter distribution.<br />
• Aspect ratio distribution.<br />
• Degree of agglomeration.<br />
• Surface area. Porosity.<br />
• Bulk chemical analysis.<br />
• Dispersibility in solid matrices in specifying<br />
nanoscale reinforcements for composites.<br />
• Strength of the interface with the matrix in<br />
specifying nanoscale<br />
reinforcements for composites.<br />
• Crystallographic and mechanical anisotropy.<br />
• Compatibility with matrices.<br />
• Dispersibility in liquid. Flow characteristics.<br />
• Surface chemical analysis.<br />
• Surface functionalization.<br />
Workshop <strong>IMNR</strong> 27 .02. 2008<br />
• Coating thickness.<br />
• Thickness uniformity.<br />
• Chemical composition of the coating.<br />
• Interfacial strength with the substrate.<br />
• Porosity.<br />
• Surface chemical composition
Measurement methods for batch quality control<br />
Particle size<br />
Distribution<br />
Particle<br />
morphology, including<br />
aspect ratio<br />
Crystallite size X-ray diffraction line<br />
broadening (XRDLB)<br />
Degree of<br />
agglomeration<br />
Surface area Porosity Crystal structure<br />
Workshop <strong>IMNR</strong> 27 .02. 2008
Clean room for the synthesis of nanostructured compounds<br />
Certification of the laboratory for chemical and physical<br />
analysis for nano-bio-materials characterization –<br />
NANOBIOMATLAB<br />
In course of accreditation (final stage march 2008)<br />
Particle sizes, zetapotential, DRX, UV-VIS, AAS, DSC<br />
Workshop <strong>IMNR</strong> 27 .02. 2008
THANK YOU FOR YOUR ATTENTION<br />
Contact: dr. Roxana Mioara Piticescu<br />
Head of Nanostructured Materials Laboratory<br />
National R&D Institute for Nonferrous and Rare Metals<br />
E-mail: roxana@imnr.ro<br />
www.imnr.ro/avanmat<br />
www.imnr.ro/retebdent<br />
www.imnr.ro/nanograf<br />
Workshop <strong>IMNR</strong> 27 .02. 2008
<strong>IMNR</strong><br />
TECHNOLOGY TRANSFER IN ADVANCED<br />
MATERIALS FROM ROMANIA:<br />
RESULTS AND EXPECTATIONS IN THE FIELD<br />
OF NANOBIOMATERIALS<br />
Radu Robert Piticescu-National Institute for Nonferrous<br />
and Rare Metals/Centre for Technology<br />
Transfer in Advanced Materials CTT AVANMAT<br />
Workshop<br />
Nanobiomatlab_27.02.2008 1
General problems of TT in the field<br />
of nanomaterials<br />
Research at frontiers high potential expected now!<br />
High expectations dissipated and slow rhythm due<br />
to different fields and new knowledge involved<br />
Limited competences interdisciplinary at superlative<br />
and communication (science – society, science-business)<br />
Development directions “pushed” by academic media<br />
and not enough “pulled” by industry<br />
Lack of qualified personnel and students<br />
Workshop<br />
Nanobiomatlab_27.02.2008 2
Other problems:<br />
Lack of simple to be applied processes<br />
for industry<br />
Lack of standard characterisation<br />
methods (nano-metrology):<br />
Committee ISO TC 229 Nanotech<br />
launched on 11 Nov.2005 in London<br />
Toxicology problems of Nanomaterials<br />
Workshop<br />
Nanobiomatlab_27.02.2008 3
Ideal Conditions for TT<br />
Universities, institutes and companies under one roof (Modern<br />
characterisation facilities, inter and multidisciplinary)<br />
“Non-conventional meeting rooms”<br />
Different types of SMEs: bio, nano, chemistry, medicine,<br />
equipments, soft….<br />
Formal integration:<br />
Joint projects<br />
Mixed financing: R&D, infrastructure, public / private<br />
Access of end-users at joint laboratories<br />
Entrepreneurial education, consultancy<br />
Workshop<br />
Nanobiomatlab_27.02.2008 4
STRONG for ROMANIA<br />
The role of high added values materials<br />
(biomaterials, inteligent materials...) in the<br />
National Development Strategy for 2007-2013<br />
Still high educated people in Academic &<br />
Research<br />
Portfolio of projects ready to be transferred<br />
Increased number of high annual<br />
development rate of SMEs profit: > 35%<br />
Infrastructure-structural funds<br />
Workshop<br />
Nanobiomatlab_27.02.2008 5
WEAK for ROMANIA<br />
Slight own investments in the field<br />
Management not enough oriented toward<br />
innovation<br />
Lack of high qualified personnel in industry<br />
Incipient stage of innovation and TT<br />
infrastructure;<br />
The slow recovery in high tech field due to<br />
not enough request for valorisation of R&D<br />
results in SMEs and enterprises<br />
Workshop<br />
Nanobiomatlab_27.02.2008 6
OPPORTUNITIES for ROMANIA<br />
New market niches for advanced materials<br />
Increasing productivity, proffit and shorter production<br />
cycles by diversification offered by new materials;<br />
Increase export of biocompatible and inteligent<br />
materials on a market still in formation;<br />
Small scale production with high added value;<br />
Pressure from incresing quality products requirements<br />
and life quality;<br />
Requirments to implement European standars;<br />
Reduce the negative impact over environement<br />
Workshop<br />
Nanobiomatlab_27.02.2008 7
THREATENS<br />
Difficulty to enter on the global market<br />
for Romanian SMEs due to high<br />
investment required and managerial<br />
drawbacks<br />
Expected reaction of concurent<br />
companies: import may exceed export<br />
and own production level<br />
Workshop<br />
Nanobiomatlab_27.02.2008 8
What we can do at CTT AVANMAT<br />
Fast technological transfer towards SME’s of the R&D results in the<br />
field of advanced biocompatible and intelligent materials (metallic,<br />
ceramic, composite);<br />
Assure a continuous qualified training in the target field for the and<br />
students specialists acting in SME's<br />
Consultancy for SME's;<br />
Forecast the market demand for medium and long term in order to<br />
align applied R&D activities to the market trend;<br />
Dissemination of knowledge related to the target filed, especially for<br />
SME's;<br />
Support SME's and other enterprises in the target field to implement<br />
European standards for the characterization of advanced materials:<br />
Establish networks that will facilitate the contact between the R&D<br />
specialists and SME's in this field and to encourage the national and<br />
international partnerships;<br />
Activities linked with intellectual property rights<br />
Workshop<br />
Nanobiomatlab_27.02.2008 9
CONTACTS<br />
National R&D Institute for Non-ferrous and Rare<br />
Metals (<strong>IMNR</strong>P- Centre for Technology Transfer in<br />
Advanced Materials (CTT AVANMAT)<br />
102 Biruintei Blvd, 077145 Pantelimon, judet Ifov,<br />
ROMANIA<br />
Tel/fax +40 21 3522046; +40 21 3522048<br />
Contact person: Dr. Robert Piticescu, director CTT<br />
AVANMAT<br />
Dr. Teodor Velea, director <strong>IMNR</strong><br />
Web page: www.imnr.ro/avanmat<br />
E-mail: rpiticescu@imnr.ro<br />
Workshop<br />
Nanobiomatlab_27.02.2008 10
Acknowledgement<br />
National Centre for Programmes Management of the<br />
National Agency for Scientific Research for support<br />
in the frame of Research for Excellence Module III<br />
Project 217/2006 VIZGRAF<br />
Thank you for your attention<br />
Workshop<br />
Nanobiomatlab_27.02.2008 11
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
Spectrometria de absorbţie atomică –<br />
metodă eficientă de caracterizare<br />
a nanobiomaterialelor<br />
Neagu Eleonora
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
<br />
Ce este spectrometria atomică?<br />
Spectrometria atomică include trei tehnici diferite: : absorbţie atomică,<br />
emisie atomică şi i fluorescenţă ă atomică. . Dintre acestea, absorbţia atomică<br />
şi i emisia atomică (AE) sunt cel mai des utilizate. Spectroscopia de masă<br />
ICP este o tehnică afiliată acestora două.<br />
<br />
Ce este absobţia atomică?<br />
În n termeni foarte simpli, absorbţia atomică este procesul care apare când<br />
atomul aflat în n stare fundamentală absoarbe energie sub formă de lumină<br />
cu o anume lungime de undă şi i este trecut într-o o stare excitată. . Cantitatea<br />
C<br />
de energie luminoasă absorbită, , caracterizată c<br />
de respectiva lungime de<br />
undă, , va creşte pe măsură ce numărul de atomi din elementul selectat<br />
aflaţi în n calea luminii, va creşte. Relaţia dintre cantitatea de lumină<br />
absorbită şi i concentraţia elementului analizat, prezentă în n standardele în<br />
vigoare, poate fi folosită pentru a determina concentraţia unei probe<br />
necunoscute în n funcţie de cantitatea de lumină absorbită.
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
Echipamentul de bază (a se<br />
a se vedea figura de mai jos) ) folosit în n absorbţia<br />
atomică constă dintr-o o sursă primară de lumină, , o sursă de atomi, , un u<br />
monocromator pentru izolarea lungimii de undă specifice luminii ce se doreşte a<br />
fi măsurată, , un detector pentru măsurarea precisă a luminii, , un sistem electronic<br />
de prelucrare a datelor şi i un sistem de afişare are a rezultatelor. În n mod obişnuit<br />
sursa de lumină este fie o lampă cu catod cavitar<br />
(HCL) fie o lampă cu<br />
descărcare fără electrod (EDL). În n general se foloseşte o lampă pentru fiecare<br />
element ce se doreşte a fi determinat, deşi,<br />
în n unele cazuri mai multe elemente<br />
pot fi combinate într-o o singură lampă multielement.<br />
Lampă HCL sau EDL<br />
Flacără<br />
Monocromator<br />
Detecor
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
<br />
Prepararea probelor<br />
- Sensibilitateatea şi i rezultatele analizei depind printre altele şi i de modul<br />
de pregătire al probei. În n cazul materialelor cu aplicaţii<br />
ii medicale (cu<br />
structură nanometrică sau nu) ) contaminarea şi i dozarea exactă a<br />
reactivilor şi i materialului de analizat sunt elemente esenţiale.<br />
- În n multe analize, prepararea probelor constă fie în n diluarea unei probe<br />
lichide sau în n dizolvarea unei probe solide urmate de diluare.<br />
- Se pot analiza materiale de diversitate foarte mare (probe geologice,<br />
ogice,<br />
zguri, şlamuri,<br />
nămoluri provenite din diversele industrii chimice, , soluţii<br />
reziduale, probe de soluri şi i ape naturale) şi i de concentraţii de la zeci de<br />
procente până la concentraţii mici (1-p)<br />
şi i foarte mici de ordinul ppm.<br />
- Contaminarea introdusă de diluanţi i sau solvenţi i poate fi semnificativă. În<br />
acest este indicată folosirea solvenţilor de puritate ridicată comercializate<br />
de firmele de specialitate. În n unele cazuri chiari şi i folosirea acetui tip de<br />
reactiv poate influenţa a negativ analiza, problema putând fi înlăturată doar<br />
printr-o o distilare ulterioară [17 – W. J. Price, Spectrochemical Analysis by Atomic<br />
Absorbtion, Heyden&Son Ltd., 1979].
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
<br />
Analiza în n urme<br />
Sensibilitatea mare a multor metale în n absorbţia atomică sugerează că<br />
aceasta este o tehnică bună pentru a determina urmele de metale în<br />
diverse materiale. Într-adevăr o bună peroioadă de timp, , această a<br />
metodă<br />
de analiză a fost privită ca o tehnică aplicabilă urmelor. În n funcţie de<br />
domeniul de activitate identificarea urmelor se justifică din diverse motive.<br />
Prezenţa în n biomateriale a elementelor nocive organismului uman este<br />
stabilită strict pentru ca acestea să îndeplinească cerinţele ele de<br />
biocompatibilitate – urmele trebuie să fie în n concentraţii de ppm sau chiar<br />
ppb. În n plus, compoziţia ia precisă a unui material este un alt factor impus de<br />
aplicaţiile iile medicale. Utilizând metoda de analiză prin absorbţie atomică în<br />
materialele biologice au fost identificate [18 – Keiichiro Fuwa, Memories of Sir Alan<br />
Walsh: atomic absorbtion spectroscopy in the field of trace elements ents in biology, Spectrochemica<br />
Acta Part B 54 (1999), 2005 - 2009]<br />
- Cd 0,0004 ppm<br />
- Mg 0,005 ppm<br />
- Cu 0,007 ppm<br />
- Co 0,013 ppm<br />
- Ni<br />
0,016 ppm.<br />
2009] urme de metale la următoarele concentraţii:
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
<br />
Aplicaţii ii ale analizei prin absorbţie atomică<br />
Absorbţia atomică este o tehnică versatilă cu o gamă largă de aplicaţii:<br />
ii:<br />
- analiza apelor şi i a soluţiilor apaoase diluate;<br />
- analize metalurgice;<br />
- analize anorganice;<br />
- materiale organice;<br />
- analize de probe biologice;<br />
- medicină şi i patologie;<br />
- metode indirecte de absorbţie atomică;<br />
- aplicaţii ii ale fluorescenţei ei atomice.
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
Echipament nou achiziţionat<br />
ionat în n cadrul proiectului<br />
NANOBIOMATLAB: Spectrometru de absorbţie atomică AAS<br />
ZEEnit 700, Analytic Jena AG - Germania<br />
- Asigură determinarea cantitativă a conţinuturilor de metale într-o o plajă largă de<br />
concentraţii de la ppb până la conţinuturi de procente şi i zeci de procente<br />
- Domeniu de lucru 185- 900 nm şi i temperatura între<br />
20- 3000 o C<br />
- Tipuri de flacără:<br />
- acetilenă / aera<br />
- acetilenă / protoxid de azot<br />
- argon pentru cuptor de grafit şi i generatorul de hidruri<br />
- Este controlat de un PC cu toate operaţiie automatizate<br />
- Aparatul AAS ZEEnit 700 foloseşte tehnicile :<br />
- tehnica cuptor cu grafit pentru probe lichide cu corecţie de tip Zeeman, are<br />
autosampler cu funcţie de diluţie<br />
ie<br />
- tehnica cuptor cu grafit pentru probe solide<br />
- tehnica flacără staţionară sau ca tehnică de injecţie ie cu simplu şi i dublu<br />
fascicul şi i corecţie de fond cu deuteriu<br />
- tehnica hidruri şi i tehnica vaporilor reci cu corecţie de fond cu lampă de<br />
deuteriu<br />
- Are o turelă de 6 poziţii ii pentru lămpi.
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
Tehnica flacără<br />
Din hidroxioapatita de sinteză se determină conţinutul<br />
de<br />
– cadmiu<br />
- PS 004 Procedura specifica pentru determinarea<br />
continutului de cadmiu din biomateriale<br />
– calciu<br />
- PS 005 Procedura specifica pentru determinarea<br />
continutului de calciu din biomateriale<br />
– plumb<br />
- PS 006 Procedura specifica pentru determinarea<br />
continutului de plumb din biomateriale<br />
Cd, Ca, Pb – impurităţi i nedorite în n hidroxiapatită – conţinuturi<br />
reglementate de standardele şi i legislaţia<br />
ia în n vigoare.<br />
Determinarea celor trei elemente reprezintă încercări propuse pentru<br />
acreditare.
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
Tehnica cuptor de grafit<br />
- Se determină conţinuturi<br />
de metale de<br />
domeniul urmelor şi ultraurmelor (ppb).<br />
- Se analizează:<br />
- cupru<br />
- argint<br />
- cobalt<br />
- cadmiu<br />
- plumb<br />
- stibiu<br />
Tehnica hidruri<br />
- Tehnica vaporilor reci se utilizează<br />
pentru determinarea conţinutului<br />
de<br />
mercur.<br />
- Tehnica hidruri se utilizează la<br />
determinarea:<br />
- arsen<br />
- stibiu<br />
- bismut<br />
- seleniu<br />
- taliu
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
PG 004 - Procedura specifica pentru determinarea<br />
continutului de cadmiu din biomateriale<br />
- rezumat -<br />
1. SCOP SI DOMENIU DE APLICARE<br />
Aceasta procedura se aplica la determinarea continutului de Cd din d<br />
hidroxiapatita utilizata in<br />
implanturi chirurgicale. Cadmiul poate fi determinat in continut de ppm si procente cu precizarea ca<br />
dilutiile probelor sa fie de concentratii corespunzatoare domeniului concentratiilor etaloanelor din<br />
curba de calibrare.<br />
2. REFERINTE NORMATIVE<br />
- Manualul de utilizare al spectrometrului de absorbtie atomica AAS ZEEnit 700 Analytic Jena.<br />
- Pye Unicam Atomic Absorption Data Book<br />
- SR ISO 6955 Metode de analiza prin spectroscopie. Emisie in flacara, absorbtie atomica si<br />
fluorescenta atomica – vocabular.<br />
- AFNOR NF T01-040 040 Méthodes M<br />
d’analyse d<br />
par spectroscopie<br />
- AFNOR NF T01-041 041 Spectrometrie d’absorbtion d<br />
atomique<br />
3. PRINCIPIUL METODEI<br />
Proba este adusa in solutie cu HCl si mici cantitati de HNO3. Solutia probei este aspirata in flacara<br />
spectrometrului de absorbtie atomica. Energia absorbita la linia de rezonanta a spectrului cadmiului<br />
este masurata si comparata cu aceea a solutiilor de calibrare. Continutul C<br />
de Cd poate fi determinat in<br />
flacara C2H2/aer si se utilizeaza o solutie de KCl tampon care creste sensibilitatea masurarii.
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
4. ECHIPAMENTE<br />
Spectrometrul de absorbtie atomica cu flacara - AAS ZEEnit 700 ANALYTIC JENA, cu o sensibilitate<br />
foarte buna, care asigura liniaritatea curbei de calibrare, semnal stabil, prevazut cu arzator de titan.<br />
Conditiile optime de lucru se stabilesc conform instructiunilor aparatului.<br />
Lampa cu catod cavitar de Cd.<br />
Compresor pentru aer comprimat si butelie de acetilena de inalta puritate.<br />
Baie electrica de nisip.<br />
Balanta analitica.<br />
5. REACTIVI<br />
5.1 HCl de concentratie 37% si puritate inalta.<br />
HNO3 de concentratie 65% si puritate inalta<br />
Solutie 1% de KCl<br />
Apa bidistilata<br />
5.2 Solutie standard primara de Cd.<br />
Se dizolva 0,5g cadmiu metalic spectral pur in 10mL acid clorhidric ric 5M si 2 picaturi HNO3. Cand<br />
solubilizarea este completa se raceste si se trece intr-un balon cotat de 500mL, se adauga apa<br />
bidistilata pana la semn si se omogenizeaza (1000mgCd/L). Se pastreaza in balon de polietilena.<br />
5.3 Solutie standard secundara de Cd.<br />
Se transfera 10mL solutie 5.2 intr-un balon cotat de 100mL (100mg de Cd/L). Se adauga apa<br />
bidistilata pana la semn si se omogenizeaza.<br />
5.4 Solutii de Cd pentru calibrare<br />
Se transfera 0,0; 0,3; 0,5; 1,0; 2; si 3,0 mL din solutia 5.3 in baloane cotate de 100mL, se adauga in<br />
fiecare cate 1mL solutie 1% KCl, 1mL HNO3, apa bidistilata pana la semn si se omogenizeaza.<br />
C2H2/aer si se utilizeaza o solutie de KCl tampon care creste sensibilitatea s<br />
masurarii.
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
6. MODUL DE LUCRU<br />
Se cantaresc probele de analizat (0,5-1g cu precizie de ±0,0001), se trec in pahare Berzelius<br />
decontaminate, se adauga 10-15mL 15mL apa bidistilata. Se solubilizeaza cu HCl (5mL) si mici cantitati de<br />
HNO3 (1mL), se trec paharele pe baia de nisip la cald, se acopera a cu sticle de ceas si se lasa pana la<br />
solubilizare. Solutia obtinuta trebuie sa fie perfect clara. Daca a raman suspensii, se filtreaza prin hartie<br />
de filtru banda alba, se spala filtrul cu portiuni mici de apa bidistilata. b<br />
Filtrul se trece intr-o o capsula de<br />
platina, se arde si urmeaza o topitura pentru reziduul ramas cu un amestec fondant (carbonat dublu<br />
de Na si Ka anhidru si borax). Topitura se solubilizeaza cu apa bidistilata si HCl si se trece intr-un<br />
balon separat de filtratul obtinut anterior. Solutiile probelor se trec in baloane cotate de 50mL cu<br />
adaos corespunzator de solutie de KCl (0,5mL sol.1%), HNO3 (0,5mL), apa bidistilata si se<br />
omogenizeaza.<br />
7. PREGATIREA APARATULUI PENTRU DETERMINARE<br />
Se pregateste spectrometrul conform instructiunilor de lucru pentru determinarea Cd. Se introduce<br />
lampa cu catod cavitar in turela, se activeaza lampa si se seteaza parametrii optici. Se optimizeaza<br />
conditiile de flacara automat prin stabilirea lungimii de unda, a inaltimii arzatorului, a debitelor de<br />
gaze, a tipului de arzator folosit si tipul de flacara (C2H2/aer).<br />
8. TRASAREA CURBEI DE CALIBRARE<br />
Se aspira in flacara C2H2/aer solutiile de Cd premixate de la paragraful 5.4, succesiv in ordine<br />
crescatoare a concentratiei de Cd. Se fac cate trei masuratori pe fiecare solutie si se inregistreaza<br />
media lor.
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
9. MASURAREA PROBELOR DE ANALIZAT<br />
Se aspira apa bidistilata acidulata (0,5% HNO3).<br />
Se marcheaza in fereastra Samples numarul de probe pentru masurat.<br />
Se aspira solutie de spalare (0,5% HNO3) intre solutiile probelor.<br />
r.<br />
Se efectueaza patru determinari pe proba si se noteaza automat media m<br />
lor.<br />
10. MODUL DE CALCUL<br />
Continutul de Cd masurat se obtine din formula :<br />
Cd,% = (a · c) / (b · 10000)<br />
unde: a – volumul balonului probei<br />
b – masa in grame a probei luata in lucru<br />
c – concentratia dupa curba de calibrare<br />
Aparatul AAS ZEEnit 700 afiseaza un raport de incercare de 4 pagini.
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
Formatul de prezentare a rezultatelor oferit de soft-wear-ul aparatului
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
Formatul de prezentare a rezultatelor oferit de soft-wear-ul aparatului
Metode spectrale (spectrometria de absorbţie atomică şi i difracţia ia de raze X):<br />
o provocare pentru caracterizarea compoziţională<br />
ională şi i microstructurală a nanomaterialelor<br />
INCDMNR - <strong>IMNR</strong><br />
27.02.2008<br />
VA MULTUMESC PENTRU<br />
ATENTIA ACORDATA
INSTITUTUL NATIONAL DE CERCETARE – DEZVOLTARE<br />
PENTRU METALE NEFEROASE SI RARE<br />
B-dul<br />
Biruintei 102, Pantelimon, , ILFOV, 077141, tel/fax (021)3522046, (021)3522048, (021)3522050, imnr@imnr.ro, www.imnr.ro<br />
Caracterizarea prin Difracţie de Raze X a Nanobiomaterialelor<br />
1. Domeniu de aplicare<br />
Examinarea prin difracţie de raze X a materialelor policristaline şi amorfe este cunoscută sub numele Difracţie de Raze X pe Pulberi (Xray<br />
Powder Diffraction / XRPD). Metodele XRPD sunt aplicabile unei vaste categorii de materiale: pulverulente / consolidate, organice /<br />
anorganice, naturale / de sinteză, cristaline / amorfe, în particular şi nanobiomaterialelor, permiţând obţinerea unei mari varietăţi de<br />
informaţii privind structura acestora:<br />
-identificarea şi cuantificarea fazelor cristaline,<br />
-estimarea conţinutului de material amorf sau dezordonat din punct de vedere cristalografic faţă de total material cristalin,<br />
- determinarea dimensiunii cristalitelor, a microdeformărilor,<br />
-determinarea structurii cristaline: parametrii de reţea şi conţinutul celulei elementare.<br />
Rezultatele examinărilor XRPD interesează tehnologia materialelor: ceramice, nanomateriale , metale si aliaje, materiale de constructie,<br />
pigmenti; în geologie: azbest, roci, argile, zeoliti, minereuri; în protecţia mediului: deseuri industriale, subproduse; în arheologie, etc.<br />
2. Referinţe normative<br />
SR EN 13925-1 Examinări nedistructive. Difracţia radiaţiilor X aplicate asupra materialelor policristaline şi amorfe. Partea I: Principii<br />
generale<br />
SR EN 13925-2 Examinări nedistructive. Difracţia radiaţiilor X aplicate asupra materialelor policristaline şi amorfe. Partea II: Proceduri<br />
SR EN 13925-3 Examinări nedistructive. Difracţia radiaţiilor X aplicate asupra materialelor policristaline şi amorfe. Partea III: Aparatură<br />
NFS 94-068 Matériaux pour implants chirurgicaux. Détermination de la cristallinité et de la dimension apparente de poudres, dépôts et<br />
céramiques à base d’ hydroxyapatite<br />
ASTM F1185-03 Standard Specification for Composition of Hydroxylapatite for Surgical Implants<br />
ASTM F 2024-00 Standard Practice for X-ray Diffraction Determination of Phase Content of Plasma Sprayed Hydroxylapatite Coatings<br />
NIST Certificate of Analysis. Standard Reference Material 676. Alumina Internal Standard for Quantitative Analysis by XRPD<br />
NIST Certificate of Analysis. Standard Reference Material 2910. Calcium Hydroxyapatite.<br />
ICDD database, Powder Diffraction File, 2006.<br />
Persoana de contact: Fiz. Viorel Badilita: vbadilita@imnr.ro / vbadilita@yahoo.com
3. Dotarea laboratorului<br />
Difractometru Bruker-AXS D8 ADVANCE în configuraţie Bragg-Brentano pentru difracţie pe pulberi, geometrie verticală θ – θ,<br />
Sursă de radiatie (Cu),<br />
Detector SOL X,<br />
Software: BRUKER AXS, DIFFRAC plus BASIC v.12, 2006<br />
Baza de date ICDD PDF-2 Release 2006.<br />
4. Procedura de caracterizare<br />
4.1. Prepararea specimenelor. Calitatea datelor colectate într-un experiment de difracţie depinde esenţial de modul în care<br />
este tratată proba din care se prepară specimenul ce urmează a fi învestigat. Prepararea specimenelor se va face în conformitate cu SR<br />
EN 13925-2. Datorită diferenţelor de proprietăţi ale diferitelor faze: densitate, dimensiune şi forma particulelor, duritate, stare de<br />
aglomerare, etc., pot apărea neomogeneităţi atât la scară microscopică cât şi macroscopică. Pentru a obţine rezultate reprezentative şi<br />
reproductibile probele trebuie măcinate mecanic sau manual (până la dimensiuni de ordinul a 10 μm cu control pe sita de 36 μm),<br />
realizând omogeneizarea probelor simultan cu creşterea numărului de cristalite în volumul specimenului iradiat. Se va evita măcinarea<br />
excesivă ca intensitate şi timp căci ar putea conduce la alterarea probei prin:<br />
-contaminarea probei cu material din componenţa instrumentului de măcinare: mojar, pistil, bile,<br />
-amorfizarea parţială a materialului de la suprafaţa particulelor prezente în probă,<br />
-reacţii în stare solidă,<br />
-tranziţii către alte forme polimorfice,<br />
-descompuneri chimice (ex.: pierderea conţinutului structural de H2O, CO2).
4.2. Achiziţia datelor se face în<br />
conformitate cu SR EN 13925-2 care în cazul<br />
difractometriei stipulează următoarele:<br />
- alegerea corespunzătoare a puterii<br />
generatorului, a fantei de limitare a<br />
divergenţei fascicolului incident, a fantei<br />
antiîmprăştiere şi a fantei detectorului pentru<br />
a obţine un compromis acceptabil între<br />
intensitatea difractată şi rezoluţia unghiulară,<br />
- alegerea corespunzătoare a intervalului<br />
unghiular de achiziţie a datelor pentru a evita<br />
pierderea de informaţie structurală utilă,<br />
-alegerea pasului unghiular se va face pentru<br />
a obţine un număr de puncte de măsură<br />
suficient de mare în jumătatea superioară a<br />
maximului liniei de difracţie,<br />
-pasul unghiular şi divergenţa unghiulară a<br />
fantei detectorului trebuie corelate pentru a<br />
asigura o bună rezoluţie a peak-urilor,<br />
- timpul de măsură pentru fiecare pas trebuie<br />
corelat cu scopul măsurătorii, cu natura<br />
probei, cu raportul semnal –fond.<br />
Interfaţa programului de achiziţie date DIFFRAC plus XRD Commender permite înregistrare în regim „Continuous”/„Step by step”;<br />
stabilirea vitezei de înregistare “Deg/min”/”Sec/Step”; setarea valorilor tensiunii – “kV” şi intensităţii – „mA” de alimentare a<br />
generatorului de raze X; setarea pasului „Increment”; a intervalulului unghiular de înregistrare a difractogramei „Start” –„Stop” şi de<br />
asemeni scanarea repetată a intervalului unghiular ales cu cumularea intensităţii înregistrate „→ Cont”, în scopul îmbunătăţirii<br />
statisticii de detecţie a fotonilor X. Difractograma se salvează pe hard sub forma unui fişier de tip *.RAW urmând a fi procesată cu alte<br />
programe.
4.3. Procesarea datelor se face în conformitate cu SR EN 13925-2. utilizând softul specializat din dotare. În<br />
procesarea datelor se va ţine seama de următoarele aspecte:<br />
-Fondul care este privit ca informaţie cuprinsă în datele colectate, dar care poate fi eliminată din analiză.<br />
-Eliminarea componentei Kα2.<br />
-Operaţii de căutare a peak-urilor.<br />
-Determinarea poziţiei şi a intensităţii.<br />
-Determinarea profilului peak-ului şi a intensităţii integrale.<br />
-Obţinerea listei d-I.<br />
-Descompunerea difractogramei în linii de difracţie individuale (inclusiv extragerea fondului), al căror profil este fitat cu ajutorul<br />
diferitelor tipuri de funcţii analitice sau prin prin abordarea parametrilor fundamentali (FPA – Fundamental Parameters<br />
Approach).<br />
- Parametrii care definesc modelul ales pentru descrierea profilului sunt rafinaţi până la realizarea minimului funcţiei:<br />
χ 2 = Σw i2<br />
[(I obs<br />
) i<br />
-(I calc<br />
) i<br />
] 2<br />
Calitatea fitării va fi evaluată prin factorul de încredere:<br />
R wp<br />
= [Σw i<br />
[(I obs<br />
) i<br />
-(I calc<br />
) i<br />
] 2 / Σw i<br />
[(I calc<br />
) i<br />
] 2 ] 1/2<br />
Relaţii în care:<br />
I obs<br />
este intensitatea observată în punctual i,<br />
I calc<br />
este intensitatea calculată în punctual i,<br />
w i<br />
= 1 / σ 2 , factor de pondere asociat fiecărui pas i de intensitate I obs<br />
σ 2<br />
reprezintă varianţa mărimii I obs
Procesarea datelor se face cu softul EVA din componenţa pachetului de programe DIFFRAC plus BASIC. Figura prezintă procesarea<br />
preliminară a datelor: datele primare (negru), datele procesate prin extragerea fondului (roşu) şi datele procesate prin eliminarea<br />
componentei Kα2 (albastru).
4.4. Analiza calitativă de fază (Identificarea fazelor) se realizează cu modulul Search/Match V12 din componenţa softului EVA în<br />
următoarele etape: - Lansarea modulului Search/Match,<br />
- Setarea de către utilizator a filtrelor şi a parametrilor de căutare,<br />
-Afişarea candidaţilor din baza de date şi selecţia finală.
4.5. Prezentarea rezultatelor se face atât sub forma unui tabel:<br />
Formula Compound Name PDF number<br />
Ca5(PO4)3(OH) Hydroxylapatite 00-009-0432 (I)<br />
Ca2.993H0.014(PO4)2 Whitlockite 01-070-2065 (I)<br />
cât şi sub formă grafică:<br />
Intensity (cps)<br />
700<br />
600<br />
500<br />
400<br />
300<br />
200<br />
100<br />
(2,0,1) Hydroxylapatite<br />
(1,0,10) Whitlockite<br />
(0,0,2) Hydroxylapatite<br />
(2,1,1) Whitlockite<br />
(1,2,2) Whitlockite<br />
(1,1,9) (2,0,8) Whitlockite<br />
(2,1,4) Whitlockite<br />
(1,0,2) Hydroxylapatite<br />
(0,0,12) (1,2,5) Whitlockite<br />
(2,1,0) Hydroxylapatite<br />
(3,0,0) Whitlockite<br />
(0,2,10) (2,1,7) Whitlockite<br />
(1,1,2) Hydroxylapatite<br />
(1,2,8) Whitlockite<br />
(3,0,0)<br />
(3,0,6)<br />
Hydroxylapatite<br />
Whitlockite<br />
(1,1,12) Whitlockite<br />
(2,0,2) Hydroxylapatite<br />
(2,2,0) Whitlockite<br />
(0,1,14) Whitlockite<br />
(2,2,3) Whitlockite<br />
(3,0,1) Hydroxylapatite<br />
(2,1,10) Whitlockite<br />
(1,3,1) Whitlockite<br />
(3,1,2) Whitlockite<br />
0<br />
25 26 27 28 29 30 31 32 33 34 35 36<br />
2Theta (deg)<br />
NII fond & KA2 extras<br />
Ca5(PO4)3(OH) - Hydroxylapatite<br />
Ca2.993H0.014(PO4)2 - Whitlockite
4.6. Analiza cantitativă (cuantificarea fazelor) şi caracterizarea cristalinităţii fazelor: implică determinarea<br />
concentraţiilor fazelor identificate în cursul analizei calitative de fază care devine astfel o etapă obligatorie a procedurii<br />
de caracterizare a nanobiomaterialelor. Programul DIFFRAC plus BASIC EVA (Bruker AXS) are în compunere un astfel de<br />
subprogram numit FPM (Full Pattern Matching) care permite o analiză cantitativă fără introducerea obligatorie a unui<br />
etalon intern, pornind de la înregistrările de referinţă din PDF, în particular de la listele (d,I).<br />
Principial difractograma unui amestec plurifazic este suma ponderată a difractogramelor fazelor componente.<br />
Ponderea fiecărei difractograme individuale în difractograma mixturii W J<br />
este denumită factor de scală al fazei J. În<br />
fiecare punct 2Θ i<br />
al difractogramei vom avea:<br />
I(2Θ i<br />
) = Σ J<br />
W J<br />
·I J<br />
(2Θ i<br />
)<br />
Suma este extinsă asupra numărului de faze din mixtură, iar I J<br />
reprezintă difractograma digitală construită pe baza<br />
listei (d,I) a fiecarei faze identificate. Cum în PDF pentru fiecare fază J sunt date doar valorile relative ale intensităţilor,<br />
normate faţă de cea mai intensă linie de difracţie, pentru a obţine valori reale, factorul de scală W J<br />
este definit ca<br />
produsul:<br />
W J<br />
= C J<br />
·R J<br />
În care: C J<br />
reprezintă concentraţia fazei J, satisfăcând condiţia:<br />
Σ J<br />
C J<br />
·= Σ J<br />
(W J<br />
/R J<br />
) = 100%<br />
R J<br />
reprezintă raportul dintre intensitatea celei mai intense linii de difracţie a fazei J şi intensitatea celei mai intense linii<br />
a corindonului (alumina α) - I/Icor - când cele două faze sunt în raport masic 1/1, mărime denumită RIR (Reference<br />
Intensity Ratio), de asemeni stocată în PDF alături de celelalte informaţii referitoare la faza J.<br />
Pornind de la lista (d,I) care este o difractogramă (schematică) de segmente, digitalizarea difractogramei se face<br />
dezvoltând segmentele în profile de maxime de difracţie prin convoluţia acestora cu funcţii pseudo-Voigt (simetrice sau<br />
asimetrice) prin rafinarea parametrilor acestor funcţii şi a factorilor de scală W J<br />
până la descrierea corectă a profilului<br />
scanării experimentale, adică până în momentul în care este se realizează condiţia de minim a mărimii:<br />
Σ i<br />
[I exp<br />
(2Θ i<br />
) - Σ J<br />
W J<br />
·I J<br />
(2Θ i<br />
)] 2 = min.<br />
O dată încheiat procesul de simulare a difractogramei experimentale sunt determinate valorile W J<br />
din care se determină<br />
valorile C J<br />
.
Dacă proba studiată nu este 100% cristalină sau nu sunt incluse în analiză toate fazele, atunci determinarea cantitativă a unei<br />
faze necesită adăugarea unei cantităţi cunoscute C s<br />
de material de referinţă (standard intern), care nu exista iniţial în proba<br />
studiată şi care va fi tratată ca orice altă fază, cu excepţia faptului că este cunoscută concentraţia sa. În această situaţie<br />
relaţia de normare a concentraţiilor în amestec devine:<br />
C s<br />
+ Σ J<br />
(W J<br />
/R J<br />
)·= 100% + C s<br />
Iar concentraţiile fazelor în amestecul final pot fi astfel determinate individual din relaţii de tipul:<br />
C Jfinal<br />
= W j<br />
/(1+C s<br />
)<br />
Tabloul următor prezintă expresia funcţiilor analitice utilizate în simularea de tip FPM:
4.6.1. Exemplificare a metodei FPM (Full Pattern Matching) de cuantificare a fazelor şi de caracterizare a cristalinităţii fazelor prin<br />
dimensiunea de cristalit (rutina FPM a programului EVA din componenţa pachetului DIFFRAC plus BASIC):<br />
Lansarea rutinei FPM şi selectarea parametrilor de lucru: fazele identificate, caracteristicele fondului, interval unghiular de simulare, etc.
Rezultatele simulării FPM cuprind scanarea experimentală primară (puncte negre), scanarea simulată (roşu) şi diferenţa lor (albastru în<br />
subsolul imaginii) care caracterizează calitatea rezultatelor alături de mărimile R wp<br />
şi R/R 0<br />
. Rezultatele metodei FPM, conţin<br />
concentraţia şi dimensiunea de cristalit corespunzătoare fiecărei faze.
Prezentarea rezultatelor este redată sub forma unui tabel:<br />
Sample name:<br />
NII<br />
File name:<br />
NII- simulare FPM.raw<br />
Date of fitting: 10.11.2007 22:19:27<br />
Fitting limits: 28.391÷33.691<br />
Number of steps: 100<br />
R/R0: 2.85<br />
RWP: 14.2<br />
Formula Compound Name PDF number Concentrations Crystallite Size (Scherrer)<br />
Ca5(PO4)3(OH) Hydroxylapatite 00-009-0432 (I) 66.2% 64.3 nm<br />
Ca2.993H0.014(PO4)2 Whitlockite 01-070-2065 (I) 33.8% 75.8 nm<br />
şi sub formă grafică:<br />
Intensity (cps)<br />
800<br />
700<br />
600<br />
500<br />
400<br />
300<br />
200<br />
100<br />
0<br />
0<br />
(0,0,12) Whitlockite<br />
(1,2,5) Whitlockite<br />
(2,1,0) Hydroxylapatite<br />
(3,0,0) Whitlockite<br />
28.5 29 30 31 32 33<br />
(0,2,10) Whitlockite<br />
(2,1,7) Whitlockite<br />
2Theta (deg)<br />
(2,1,1) Hydroxylapatite<br />
(1,1,2) Hydroxylapatite<br />
(1,2,8) Whitlockite<br />
(3,0,0) Hydroxylapatite<br />
(3,0,6) Whitlockite<br />
(1,1,12) Whitlockite<br />
28.5 29 30 31 32 33<br />
NII<br />
NII simulare FPM<br />
NII diferenta<br />
Ca5(PO4)3(OH) - Hydroxylapatite 66.2%<br />
Ca2.993H0.014(PO4)2 - Whitlockite 33.8%
4.6.2. Exemplificare a metodei FPM (Full Pattern Matching) pentru caracterizarea cristalinităţii prin determinarea conţinutului de material<br />
cristalin utilizând analiza cantitativă de fază cu standard intern. Pentru exemplificare a fost aleasă o pulbere obţinută hidrotermal, proba<br />
HA6 care permite identificarea unei singure faze cristaline: Ca5(PO4)3(OH) - Hydroxylapatite. Inspecţia vizuală a difractogarmei<br />
materialului original a sugerat prezenţa semnificativă a unei cantităţi de material dezordonat d.p.d.v. cristalografic. Acesta include de<br />
regulă materialul amorf, materialul rezultat din relaxarea legăturilor chimice şi din existenţa unor legături nesatisfăcute la limita de<br />
grăunte sau pe suprafaţa particulelor. Acest material va difracta radiaţia X în mod diferit de materialul din interiorul volumului<br />
cristalitelor, putând fi considerat ca o fracţie de material amorf sau dezordonat. Chiar dacă nu poate fi identificat pe difractograme, prin<br />
maxime difuze specifice amorfului, prezenţa acestui material se manifestă prin diminuarea maximelor de difracţie ale fazelor cristalizate.<br />
Pentru determinarea sa<br />
cantitativă trebuie utilizată analiza<br />
de fază cu etalon intern, descrisă<br />
anterior, care permite<br />
determinarea prin diferenţă a<br />
conţinutului de material<br />
dezordonat d.p.d.v. cristalografic.<br />
O porţie de 2g din materialul<br />
original a fost amestecată cu<br />
0.400g de pulbere de Corindon<br />
folosită ca standard intern.<br />
Cântăririle s-au efectuat cu<br />
balanţa analitică. Omogenizarea<br />
şi micronizarea amestecului s-a<br />
făcut prin mojarare manuală în<br />
mojar de agat. Eşantionul astfel<br />
obţinut, numit HA6&20%Cor, a<br />
fost caracterizat prin metoda<br />
FPM.<br />
Figura alăturată prezintă o etapă<br />
intermediară din rularea rutinei<br />
FPM pentru acest esantion.
Prezentarea rezultatelor sub forma de tabel:<br />
Sample name: HA6&20%Cor<br />
File name:<br />
HA6&20%Cor-simulare FPM<br />
Date of fitting: 11.11.2007 10:55:29<br />
Fitting limits: 26.697 59.191<br />
Number of steps: 42<br />
R/R0: 1.17<br />
RWP: 22.1<br />
Formula Compound Name PDF number Conc. Cry. Size (Scherrer)<br />
Ca5(PO4)3(OH) Hydroxylapatite 00-009-0432 (I) 88.7% 23.2 nm<br />
Amorphous - - rest (11.3%) -<br />
şi sub formă grafică (scanarea primară - puncte negre, scanarea simulată - albastru şi diferenţa lor - mov):<br />
100<br />
Intensity (cps)<br />
0<br />
27 30 40 50<br />
2Theta (deg)<br />
0<br />
27 30 40 50<br />
HA6&20%Cor<br />
HA6&20%Cor diferenta<br />
HA6&20%Cor simulare FPM<br />
Hydroxylapatite cristalin 88.7%<br />
Corundum 20% adaos la proba initiala
Această prezentare se incheie aici, fară pretentia de a fi<br />
exhaustivă, doar cu speranta de a fi suficient de convingătoare în<br />
încercarea de a demonstra utilitatea metodei de Difractie de Raze<br />
X pe Pulberi în caracterizarea bionanomaterialelor dar si a<br />
altor categorii de materiale.<br />
Vă multumesc pentru timpul si atentia acordată!<br />
Viorel Badilita<br />
Persoana de contact: Fiz. Viorel Badilita:<br />
vbadilita@imnr.ro / vbadilita@yahoo.com