NORMATIVE 46<br />
5.The design seismic inertia forces F H and F V acting on the ground mass, for<br />
the horizontal and vertical directions respectively, in pseudo-static analyses<br />
shall be taken as:<br />
F H<br />
= 0,5<br />
S W<br />
F V<br />
= ± 0,5 F H<br />
if the ratio a vg<br />
/a g<br />
is greater than 0,6<br />
F V<br />
= ± 0,33 F H<br />
if the ratio a vg<br />
/a g<br />
is not greater than 0,6.<br />
Where:<br />
is the ratio of the design ground acceleration on type A<br />
ground, a g<br />
, to the acceleration of gravity g;<br />
a vg<br />
a g<br />
is the design ground acceleration in the vertical direction;<br />
is the design ground acceleration for type A ground;<br />
S is the soil parameter of EN 1998-1:2004, 3.2.2.2;<br />
W<br />
is the weight of the sliding mass.<br />
A topographic amplification factor for a g shall be taken into account according<br />
to 4.1.3.2 (2).<br />
6. A limit state condition shall then be checked for the least safe potential slip<br />
surface.<br />
7. The serviceability limit state condition may be checked by calculating the<br />
permanent displacement of the sliding mass by using a simplified dynamic model<br />
consisting of a rigid block sliding against a friction force on the slope. In this<br />
model the seismic action should be a time history representation in accordance<br />
with 2.2 and based on the design acceleration without reductions.<br />
8. Simplified methods, such as the pseudo-static simplified methods mentioned<br />
in (3) to (6) in this subclause, shall not be used for soils capable of developing<br />
high pore water pressures or significant degradation of stiffness under cyclic<br />
loading.<br />
9. The pore pressure increment should be evaluated using appropriate tests. In<br />
© <strong>GeoStru</strong> <strong>Software</strong>-<strong>Slope</strong> 8.0.1