NORMATIVE 46<br />

5.The design seismic inertia forces F H and F V acting on the ground mass, for<br />

the horizontal and vertical directions respectively, in pseudo-static analyses<br />

shall be taken as:<br />

F H<br />

= 0,5<br />

S W<br />

F V<br />

= ± 0,5 F H<br />

if the ratio a vg<br />

/a g<br />

is greater than 0,6<br />

F V<br />

= ± 0,33 F H<br />

if the ratio a vg<br />

/a g<br />

is not greater than 0,6.<br />

Where:<br />

is the ratio of the design ground acceleration on type A<br />

ground, a g<br />

, to the acceleration of gravity g;<br />

a vg<br />

a g<br />

is the design ground acceleration in the vertical direction;<br />

is the design ground acceleration for type A ground;<br />

S is the soil parameter of EN 1998-1:2004, 3.2.2.2;<br />

W<br />

is the weight of the sliding mass.<br />

A topographic amplification factor for a g shall be taken into account according<br />

to 4.1.3.2 (2).<br />

6. A limit state condition shall then be checked for the least safe potential slip<br />

surface.<br />

7. The serviceability limit state condition may be checked by calculating the<br />

permanent displacement of the sliding mass by using a simplified dynamic model<br />

consisting of a rigid block sliding against a friction force on the slope. In this<br />

model the seismic action should be a time history representation in accordance<br />

with 2.2 and based on the design acceleration without reductions.<br />

8. Simplified methods, such as the pseudo-static simplified methods mentioned<br />

in (3) to (6) in this subclause, shall not be used for soils capable of developing<br />

high pore water pressures or significant degradation of stiffness under cyclic<br />

loading.<br />

9. The pore pressure increment should be evaluated using appropriate tests. In<br />

© <strong>GeoStru</strong> <strong>Software</strong>-<strong>Slope</strong> 8.0.1