Debit masic minim<br />

Pentru a putea respecta puterea <strong>de</strong><br />

incalzire indicata in tabel, trebuie asigurat<br />

un <strong>de</strong>bit minim necesar pentru<br />

o curgere turbulenta in tuburi. Acest<br />

<strong>de</strong>bit minim <strong>de</strong> apa <strong>de</strong>pin<strong>de</strong> <strong>de</strong> temperatura<br />

cea mai joasa din sistem.<br />

Pentru functia <strong>de</strong> incalzire, aceasta<br />

corespun<strong>de</strong> cu temperatura <strong>de</strong> retur.<br />

Pentru functia <strong>de</strong> racire, aceasta<br />

corespun<strong>de</strong> cu temperatura tur a<br />

circuitului <strong>de</strong> apa rece. Daca <strong>de</strong>bitul<br />

minim <strong>de</strong> apa pentru fiecare tub nu<br />

este atins, este posibila o sca<strong>de</strong>re a<br />

capacitatii cu aproximativ 15%.<br />

Temperaturi limita<br />

Pentru ca sistemul radiant sa<br />

garanteze un confort optim,<br />

trebuie sa se aleaga pentru <strong>proiectare</strong><br />

temperatura corespunzatoare<br />

medie a agentului termic. Aceasta<br />

poate fi verificata cu ajutorul tabelului<br />

si a diagramei alaturate. Temperatura<br />

pentru <strong>proiectare</strong> trebuie <strong>de</strong>ci sa fie<br />

inferioara celor doua valori limita.<br />

Aceste valori sunt cu titlu informativ.<br />

Se poate efectua un calcul <strong>de</strong>taliat<br />

conform ISO 7730.<br />

Inaltime<br />

m<br />

bei<br />

10%<br />

Parte a suprafefeit ta vanului ocupata<br />

<strong>de</strong> panourile radianteZehn<strong>de</strong>r <strong>ZBN</strong><br />

bei<br />

15%<br />

bei<br />

20%<br />

bei<br />

25%<br />

bei<br />

30%<br />

temperatura medie a agentului termic °C<br />

bei<br />

35%<br />

3 73 71 68 64 58 56<br />

4 115 105 91 78 67 60<br />

5 >147 123 100 83 71 64<br />

6 132 104 87 75 69<br />

7 137 108 91 80 74<br />

8 >141 112 96 86 80<br />

9 117 101 92 87<br />

10 122 107 98 94<br />

Etapa 1 : nivel <strong>de</strong> ocupare a<br />

tavanului. Temperatura <strong>de</strong> <strong>proiectare</strong><br />

nu trebuie sa <strong>de</strong>paseasca pragurile<br />

stabilite.<br />

Protectie impotriva<br />

loviturilor <strong>de</strong> minge<br />

Atunci cand sunt instalate in salile <strong>de</strong><br />

sport, stabilitatea panourilor radiante<br />

este extrem <strong>de</strong> importanta, mai ales<br />

atunci cand sunt lovite in mod acci<strong>de</strong>ntal<br />

<strong>de</strong> mingi. Din acest motiv<br />

panourile radiante Zehn<strong>de</strong>r <strong>ZBN</strong> sunt<br />

atestate conform DIN 18032, partea<br />

3, cu privire la protectia impotriva<br />

loviturilor <strong>de</strong> minge. Testul a fost<br />

<strong>de</strong>sfasurat la Institutul <strong>de</strong> Testare a<br />

Materialelor din Stuttgart.<br />