12.07.2015 Views

EZ-SRV Cartridge Relief Valves

EZ-SRV Cartridge Relief Valves

EZ-SRV Cartridge Relief Valves

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>EZ</strong>-<strong>SRV</strong> CARTRIDGE RELIEF VALVEHansen <strong>EZ</strong>-<strong>SRV</strong> <strong>Cartridge</strong> Pressure-<strong>Relief</strong> <strong>Valves</strong> protectrefrigeration pressure vessels and other refrigeration systemcomponents from excessive pressure. If an abnormally highpressure occurs, the cartridge pressure-relief valve will opento relieve the excess pressure, preventing potential damage toequipment and injury to personnel.<strong>EZ</strong>-<strong>SRV</strong> valves are built in strict conformance with bothASME Boiler and Pressure Vessel Code requirements and ISO4126 — Safety Devices for Protection of Excessive Pressure.Each valve bears the ASME code symbol of certification (UV)and CE mark. Valve capacities are rated by the National Boardof Boiler and Pressure Vessel Inspectors (NB).<strong>EZ</strong>-<strong>SRV</strong>Replacement<strong>Cartridge</strong>Refrigeration pressure-relief valves are recommended forreplacement at least every five years. However, if a relief valvehas discharged, it must be replaced as soon as possible. Valvereplacement with the Hansen <strong>EZ</strong>-<strong>SRV</strong> is fast and easy —saving significant time and expense compared to traditionalrelief valves. The revolutionary design allows for quick, easyreplacement of the cartridge with no need to disconnect fromthe relief piping.The Hansen <strong>EZ</strong>-Fitting is available with welded or threaded endconnections and a ¼˝ NPT connection. An optional HansenGauge Valve can be installed with a tell-tale pressure gaugeto indicate overpressure of a valve and whether pressure ispresent when servicing or troubleshooting system. The gaugevalve can also be used to safely bleed-off residual pressurebetween a three-way manifold valve and the <strong>EZ</strong>-<strong>SRV</strong> valve.<strong>EZ</strong>-FittingAPPLICATIONSHansen <strong>EZ</strong>-<strong>SRV</strong> cartridge pressure-relief valves are typicallyinstalled on pressure vessels to protect from overpressure andcomply with the requirements of ANSI/ASHRAE Standard 15-2007Safety Standard for Refrigeration Systems and European PressureEquipment Directive (PED) requirements. Once installed, a properlyselected Hansen <strong>EZ</strong>-<strong>SRV</strong> cartridge pressure-relief valve will vent toatmosphere excessive overpressure and quickly reseat to minimizeloss of refrigerant. Optional Hansen Rupture Disc Assemblies (RDAs)help indicate when a pressure-relief valve has discharged. Rupturediscs remain open after bursting and if installed with a pressuregauge or switch (required by code), will provide a visual or electronicindication of the occurrence.For liquid relief, Hansen offers the <strong>EZ</strong>LQ liquid relief valve, ratedU.S. GPM. Typical applications include ASME vessels, oil coolersand other components that can be isolated by control valves ormanual shut-off valves.QUICK, EASY REPLACEMENT<strong>EZ</strong>-<strong>SRV</strong> valves offer the same reduced capacities as HansenH5600 "R" series relief valves. The Hansen <strong>EZ</strong>-Adapter simplifiesretrofitting of existing Hansen relief valves. The <strong>EZ</strong>-Adapter providesthe same centerline dimensions as the H5600 series relief valveinstalled with a 2˝ long nipple, thereby minimizing piping changes todischarge line connections.KEY FEATURES – <strong>EZ</strong>-<strong>SRV</strong> Revolutionary cartridge design allowsfor quick and easy replacement—noneed to disconnect from piping Significant time and cost savingscompared to replacement oftraditional relief valves Capacities match existing HansenH5600 "R" series relief valves <strong>EZ</strong>-Fittings have a built in gauge port tofacilitate safer and controlled servicing Optional welded connections eliminatethreaded joint leak potential Low blowdown (15% or less) for gasservice minimizes refrigerant loss <strong>EZ</strong>-Adapter component for simpleretrofit to existing Hansen relief valves <strong>EZ</strong>LQ Liquid Rated <strong>Relief</strong> Valve available<strong>EZ</strong>-AdapterOptional H7771 GaugeValve with HG27Pressure Gauge<strong>EZ</strong>-<strong>SRV</strong>OptionalRupture Disc

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!