CAPÍTULO 8 - DISPOSITIVOS OPCIONAIS<br />

8.24.7 Conexão Física<br />

RS-232 e RS-485<br />

<strong>CFW</strong>-<strong>08</strong><br />

<strong>CFW</strong>-<strong>08</strong><br />

<strong>CFW</strong>-<strong>08</strong><br />

KRS-485-<strong>CFW</strong><strong>08</strong><br />

Mestre da<br />

rede<br />

(PC, CLP)<br />

RS-485<br />

A B<br />

RS-485<br />

XC29<br />

A B<br />

Blindagem<br />

do cabo<br />

RS-485<br />

XC29<br />

Figura 8.32 - Conexão do <strong>CFW</strong>-<strong>08</strong> em rede RS-485<br />

Observações:<br />

Terminação da linha: Conectar os resistores de terminação<br />

nos extremos da linha.<br />

Aterramento da blindagem dos cabos: conectar as<br />

mesmas à carcaça dos equipamentos (devidamente<br />

aterrada).<br />

Cabo recomendado: para balanceado blindado.<br />

Ex.: Linha AFS, fabricante KMP.<br />

A pinagem do conector XC8 do módulo KCS-<strong>CFW</strong><strong>08</strong>-S é<br />

apresentado na figura abaixo.<br />

+5 V<br />

1<br />

2<br />

RTS<br />

0 V<br />

3<br />

Figura 8.33 - Descrição dos sinais do conector XC8 (RJ-6)<br />

NOTA!<br />

A fiação serial RS-232 deve estar separada dos demais cabos<br />

de potência e comando em 110 V/220 V.<br />

NOTA!<br />

Não é possível utilizar simultaneamente RS-232 e RS-485.<br />

6<br />

5<br />

4<br />

TX<br />

0 V<br />

RX<br />