3004346_2012_12_07.fm Electrical connections<br />
2.2.1 Fault finding one-phase EC motors.<br />
Dio<strong>de</strong>s • Dio<strong>de</strong> 1: Red<br />
• Dio<strong>de</strong> 2: Yellow<br />
• Dio<strong>de</strong> 3: Green<br />
Troubleshooting<br />
chart<br />
• Green dio<strong>de</strong> lights up: no errors<br />
• Red dio<strong>de</strong> lights up: there is an error. Alarm relay has been tripped.<br />
• Yellow dio<strong>de</strong>: blinks for error type<br />
Error co<strong>de</strong> Green Red Yellow Error Relay<br />
None + - -<br />
1 Reserved<br />
2 - + Blinks twice/pause 4 seconds Below voltage 170 v +<br />
3 - + Blinks 3 times/pause 4 seconds Above voltage 255 v +<br />
4 + - Blinks 4 times/pause 4 seconds Overcurrent: Reduced<br />
rpm<br />
-<br />
5 Reserved<br />
6 + - Blinks 6 times/pause 4 seconds Overheating: Reduced<br />
rpm<br />
-<br />
7 - + Blinks 7 times/pause 4 seconds Overheating: Stop +<br />
8 - + Blinks 8 times/pause 4 seconds Hardware error +<br />
9 - + Blinks 9 times/pause 4 seconds MCE Fault +<br />
10 - + Blinks 10 times/pause 4<br />
seconds<br />
Motor blocked +<br />
11 - + Blinks 11 times/pause 4<br />
seconds<br />
Motor phase missing +<br />
12 Reserved<br />
13 - + Reserved<br />
14 Reserved<br />
15 Reserved<br />
16 - + Blinks 16 times/pause 4<br />
seconds<br />
Communication error +<br />
NB When the error has been remedied, the LED indicator (LED blink) on the EC control can be reset<br />
by temporarily cutting the power until the LED goes out.<br />
EXHAUSTO provi<strong>de</strong>s a two-year manufacturer's warranty on the fan.<br />