DAMPER SETTING<br />
Measurement socket, fig. 8<br />
The measurement socket (marked M)<br />
is used to<br />
take the measurement pressure ( Pm).<br />
Use the measurement pressure (Pm) and the<br />
position of the damper to check the airflow on the<br />
initial adjustment diagrams, where B1B5 refers to<br />
basic ventilation and A1-A5 refers to forced<br />
ventilation.<br />
If you wish to change the airflow, use the diagrams<br />
to gauge a new damper setting and then adjust the<br />
position of the damper as <strong>de</strong>scribed below.<br />
Damper adjustment, fig. 9<br />
Adjustment of forced ventilation, A.<br />
Set the cooker hood to basic ventilation. To alter<br />
the forced ventilation, loosen the screw and move<br />
stop F to the position required. Retighten the<br />
screw. Set the cooker hood to step 3. Measure the<br />
pressure (Pm) and check that the <strong>de</strong>sired forced<br />
ventilation level has been achieved.<br />
Initial adjustment of basic ventilation, B.<br />
To alter basic ventilation, loosen screws ( H).<br />
Press<br />
down on the Torx screwdriver. This will release the<br />
damper plate from the sprocket and operating<br />
lever <strong>de</strong>vice. Select the <strong>de</strong>sired position for the<br />
damper plate and stop G and then move them<br />
approx. 1 mm further towards “closed”. Press the<br />
screws ( H)<br />
up again until the damper plate<br />
catches. Then retighten the screws ( H).<br />
Fine adjust<br />
the setting by moving stop G to the position<br />
required. Set the cooker hood to basic ventilation.<br />
Measure the pressure (Pm) and check that the<br />
<strong>de</strong>sired basic ventilation level has been achieved.<br />
If setting dial D (fig. 5), springs back when in the<br />
position for forced ventilation for wet rooms,<br />
adjustment of the damper plate must be repeated<br />
in exactly the same way as <strong>de</strong>scribed above.<br />
Factory setting<br />
On <strong>de</strong>livery, the damper in the cooker hood is set<br />
to:<br />
Basic ventilation 20 l/s (72 m³/h) at 120 Pa<br />
Damper setting B 4.3<br />
Noise pressure level = 27 dB(A)<br />
Forced ventilation 40 l/s (144 m³/h) at 100 Pa<br />
Damper setting A 3.7<br />
Noise pressure level = 32 dB(A)<br />
The noise pressure level does not inclu<strong>de</strong> any<br />
noise from the fan.<br />
The factory settings are marked on the diagrams<br />
as an example.<br />
8<br />
9<br />
M<br />
B<br />
M<br />
B<br />
1 2 3 4 5<br />
G<br />
B<br />
Torx str. 10<br />
1 2 3 4 5<br />
B<br />
A<br />
1<br />
2<br />
3 4 5<br />
A<br />
H<br />
20<br />
A 1 2 3 4 5<br />
F<br />
A