EXHAUSTO 3002324 / 123161 / 20030502 / PMH<br />

UK<br />

DAMPER SETTING<br />

Measurement socket, fig. 8<br />

The measurement socket (marked M)<br />

is used to<br />

take the measurement pressure ( Pm).<br />

Use the measurement pressure (Pm) and the<br />

position of the damper to check the airflow on the<br />

initial adjustment diagrams, where B1B5 refers to<br />

basic ventilation and A1-A5 refers to forced<br />

ventilation.<br />

If you wish to change the airflow, use the diagrams<br />

to gauge a new damper setting and then adjust the<br />

position of the damper as <strong>de</strong>scribed below.<br />

Damper adjustment, fig. 9<br />

Adjustment of forced ventilation, A.<br />

Set the cooker hood to basic ventilation. To alter<br />

the forced ventilation, loosen the screw and move<br />

stop F to the position required. Retighten the<br />

screw. Set the cooker hood to step 3. Measure the<br />

pressure (Pm) and check that the <strong>de</strong>sired forced<br />

ventilation level has been achieved.<br />

Initial adjustment of basic ventilation, B.<br />

To alter basic ventilation, loosen screws ( H).<br />

Press<br />

down on the Torx screwdriver. This will release the<br />

damper plate from the sprocket and operating<br />

lever <strong>de</strong>vice. Select the <strong>de</strong>sired position for the<br />

damper plate and stop G and then move them<br />

approx. 1 mm further towards “closed”. Press the<br />

screws ( H)<br />

up again until the damper plate<br />

catches. Then retighten the screws ( H).<br />

Fine adjust<br />

the setting by moving stop G to the position<br />

required. Set the cooker hood to basic ventilation.<br />

Measure the pressure (Pm) and check that the<br />

<strong>de</strong>sired basic ventilation level has been achieved.<br />

If setting dial D (fig. 5), springs back when in the<br />

position for forced ventilation for wet rooms,<br />

adjustment of the damper plate must be repeated<br />

in exactly the same way as <strong>de</strong>scribed above.<br />

Factory setting<br />

On <strong>de</strong>livery, the damper in the cooker hood is set<br />

to:<br />

Basic ventilation 20 l/s (72 m³/h) at 120 Pa<br />

Damper setting B 4.3<br />

Noise pressure level = 27 dB(A)<br />

Forced ventilation 40 l/s (144 m³/h) at 100 Pa<br />

Damper setting A 3.7<br />

Noise pressure level = 32 dB(A)<br />

The noise pressure level does not inclu<strong>de</strong> any<br />

noise from the fan.<br />

The factory settings are marked on the diagrams<br />

as an example.<br />

8<br />

9<br />

M<br />

B<br />

M<br />

B<br />

1 2 3 4 5<br />

G<br />

B<br />

Torx str. 10<br />

1 2 3 4 5<br />

B<br />

A<br />

1<br />

2<br />

3 4 5<br />

A<br />

H<br />

20<br />

A 1 2 3 4 5<br />

F<br />

A