13.07.2015 Views

User Manual - Data Migration - DK - Energinet.dk

User Manual - Data Migration - DK - Energinet.dk

User Manual - Data Migration - DK - Energinet.dk

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Brugermanual – <strong>Data</strong>migreringVersion 1.0.4Dato 13. april 2012RuleNumberVAL-060VAL-061VAL-062VAL-063VAL-064VAL-065VAL-066VAL-067VAL-068VAL-069VAL-070VAL-071VAL-072VAL-073VAL-074Rule Description Attribute Rule Type ExplanationThe consumption overrun allowed of ametering point is mandatory for a profiledmetering pointThe consumption overrun allowed of ametering point has domain values 1 (Yes), 0(No)The submission delay of a metering point ismandatory for an automatic metering pointThe submission delay of a metering point hasformat DDDThe meter reading occurrence of a meteringpoint is mandatory for a non consumptionmetering pointThe meter reading occurrence of a meteringpoint is mandatory for an automaticconsumption metering pointThe meter reading occurrence of a meteringpoint has domain values PT15M (Every 15minutes), PT1H (Every hour), P1M (Everymonth), P1Y (Every year), ANDET (Other)The source metering grid area of a meteringpoint is mandatoryThe source grid area of a metering point mustbe an existing metering grid areaThe target metering grid area of a meteringpoint is mandatoryThe target grid area of a metering point mustbe an existing metering grid areaThe net settlement group of a metering pointis mandatoryThe net settlement group of a metering pointhas domain values 0, 1, 2, 3, 4, 5, 6The power plant of a metering point ismandatoryThe power plant of a metering point is a validGSRN/EAN18 code (checksum) that starts withe12ConsumptionOverrunAllowedSettlementMethod*ConsumptionOverrunAllowedSubmissionDelayMPReadingCharacteristics*ObligationDependancyDomainObligationDependancyA profiled metering point cannot be registered in CCR without a valid consumptionoverrun allowedOnly specific domain values are allowedAn automatic metering point cannot be registered in CCR without a valid submissiondelaySubmissionDelay Format Delay format is '', so length is restricted to maximal 3MeterReadingOccurrenceTypeOfMPMeterReadingOccurrenceMPReadingCharacteristics*ObligationDependancyObligationDependancyMeterReadingOccurrence Domain Only specific domain values are allowedFromGridAreaIdTypeOfMPObligationDependancyA non consumption metering point cannot be registered in CCR without a valid meterreading occurrenceAn automatic consumption metering point cannot be registered in CCR without a validmeter reading occurrenceAn exchange metering point cannot be registered in CCR without a valid sourcemetering grid areaFromGridArea Reference Only registered from grid areas are allowedToGridAreaIdTypeOfMPObligationDependancyAn exchange metering point cannot be registered in CCR without a valid targetmetering grid areaToGridAreaId Reference Only registered to grid areas are allowedNetSettlementGroupTypeOfMPObligationDependancyNetSettlementGroup Domain Only specific domain values are allowedPowerPlantGSRNTypeOfMPObligationDependancyA metering point cannot be registered in CCR without a valid net settlement groupA metering point cannot be registered in CCR without a valid power plantPowerPlantGSRN Calculation A GSRN code holds 18 digits, the first 2 digits are '57', the last digit contains thechecksum of the preceeding 17 digits, i.e. sum(odd x 3, even x 1) mod 10side 57 af 60

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!