ENGLISH<br />

• Keep the work area clean and well lit.<br />

• Check that the mains voltage corresponds to the rated voltage on the type plate.<br />

• The tool must be connected to an earthed socket.<br />

• Avoid overloading.<br />

• If using the tool outdoors, only use an extension cord approved for outdoor use. Check that the crosssection<br />

of the extension cord’s conductors is suffi cient for the motor’s power supply. Never pull the power<br />

cord to remove the plug from the mains socket. Keep the power cord away from heat, oil and sharp edges.<br />

• Do not use the tool if the cord or plug is damaged.<br />

• Unplug the power cord before performing maintenance and/or cleaning and when the tool is not in use.<br />

• The tool must not be used for mixing material with a fl ash point lower than 21°C.<br />

• Do not use solvent to clean the tool – risk of explosion.<br />

• Do not use the tool in explosive environments, such as in the vicinity of fl ammable liquids, gases or dust.<br />

• Make sure that the mixing drum is standing on a level surface.<br />

• Do not start the tool until the mixer is immersed in the mixing drum.<br />

• Do not run the tool with no load.<br />

• Do not lift up the mixer from the mixture until all moving parts have completely stopped. Make sure that the<br />

mixer does not come into contact with the mixing drum while the tool is running.<br />

• Do not start the tool in a mixing drum containing hardened material.<br />

• Wear eye and ear protection.<br />

• Only use original spare parts.<br />

TECHNICAL DATA<br />

Rated voltage<br />

Output<br />

Speed (no load)<br />

Spindle size<br />

Mixer diameter<br />

Sound pressure level, LpA<br />

Sound power level, LwA<br />

Vibration level<br />

230 V ~ 50 Hz<br />

1200 W<br />

I: 0-500 rpm<br />

II: 0-700 rpm<br />

Ø 14 mm<br />

120 mm<br />

89 dB(A), K=3 dB<br />

100 dB(A), K=3 dB<br />

5.7 m/s², K=1.5 m/s²<br />

Always wear ear protection!<br />

The declared vibration value, which has been measured by a standardised test method, can be used to<br />

compare different tools with each other and for a preliminary assessment of exposure.<br />

WARNING The actual vibration level when using power tools may differ from the specifi ed maximum value,<br />

depending on how the tool is used. It is therefore necessary to determine which safety precautions are required<br />

to protect the user, based on an estimate of exposure in actual operating conditions (taking into account all<br />

stages of the work cycle, e.g. the time when the tool is switched off and when it is idling, in addition to the<br />

start-up time).<br />