29 Montering af ”Protector System”<br />
(se tilbehør)<br />
Installér dette tilbehør i forbindelse med alle<br />
”Canopy”-vippeporte, Vippeport med lodret og<br />
vandret køreskinne , porte på over 2,5 m og hvis<br />
lukkekraften målt på underkanten af porten er på<br />
mere end 400N (40 kg).<br />
Efter åbneren er blevet installeret og justeret, kan<br />
Protector-systemet installeres som ekstraudstyr.<br />
Instruktioner leveres med dette.<br />
Protector-systemet giver en yderligere grad af<br />
sikkerhed mod, at små børn kommer i klemme<br />
under garageporten.<br />
Systemet anvender en usynlig stråle som, når den<br />
brydes af en hindring, får en port, som er i færd med<br />
30 Specialudsty<br />
1. Tilslutning for dør i porten<br />
Lysafskærmningen åbnes. Under afskærmningen<br />
findes der ekstra lyntilslutningsklemmer.<br />
Ringeledning tilsluttes til lyntilslutningsklemme 1<br />
og 2.<br />
2. Tilslutning af blinklys<br />
Blinklyset kan installeres på et hvilket som helst<br />
egnet sted. Tilhørende ledninger tilsluttes til<br />
lyntilslutningsklemmerne 3 og 4. Klemme 4 er<br />
jordforbundet.<br />
58LM<br />
75LM<br />
78LM<br />
98LM<br />
31<br />
Tilbehør<br />
(1) Model 94330E Fjernbetjening med<br />
enkeltfunktion<br />
(2) Model 94333E Fjernbetjening med 3 funktioner<br />
(3) Model 94335E Minifjernbetjeningssender med 3<br />
funktioner<br />
(4) Model 9747E Åbningssystem uden nøgle<br />
(5) Model 78LM Multikontrolpanel til port<br />
(6) Model 75E Baggrundbelyst<br />
vægkontrolpanel<br />
(7) Model 98LM Vægkontrolpanel med<br />
bevægelsesmelder<br />
(8) Model 760E Udendørs lås<br />
(9) Model 1702E Nødudløser for lås<br />
(10) Model 770E Protector-systemet<br />
(11) Model FLA230 Blinklyssæt<br />
94330E 94333E 94335E 9747E<br />
760E<br />
MDL100LM<br />
1<br />
8<br />
114A2910B-DK<br />
1702E<br />
14<br />
9<br />
2<br />
EQLl01<br />
15<br />
3<br />
770E<br />
12-DK<br />
at lukke, til at åbne og forhindrer en åben port i at<br />
lukke og det anbefales stærkt til husejere med små<br />
børn.<br />
OBS! <strong>Port</strong>åbneren vil automatisk detektere Protector<br />
Systemet, når dette er installeret. <strong>Port</strong>åbneren lukker<br />
ikke, før sonsorerne er indjusteret.<br />
LOCK<br />
LIGHT<br />
7430E<br />
<strong>800</strong>2E<br />
o<br />
180s 60s<br />
120s<br />
©<br />
1 2<br />
3<br />
16200LM FLA230 770E<br />
(12) Model 1703E The Chamberlain Arm<br />
(13) Model 16200LM <strong>Port</strong> i port-kontakt<br />
(14) Model MDL100LM Låseudstyr til mekanisk port<br />
(15) Model EQLI01 Hurtigudløsning for<br />
porthåndtag<br />
(16) Model 9-13-1 <strong>Port</strong>forstærkning<br />
VEJLEDNING FOR TILSLUTNING AF LEDNINGER<br />
TIL TILBEHØR<br />
Nøgleafbyder – til portåbnerens tilslutningsklemmer:<br />
Rød-1 og hvid-2<br />
Protector System – til portåbnerens<br />
tilslutningsklemmer: Hvid-3 og grå-4<br />
Vægkontrolpanel – til portåbnerens<br />
tilslutningsklemmer: Rød-1 og hvid-2<br />
10 11<br />
9-13-1<br />
FLA230<br />
16<br />
4<br />
78LM<br />
LOCK<br />
LIGHT<br />
12<br />
5<br />
1703E<br />
75LM<br />
6<br />
16200LM<br />
98LM<br />
LOCK LIGHT<br />
13<br />
7<br />
9 Fasten Rail to Opener and Install<br />
Chain/Belt<br />
Holding chain (4) and belt (5) out of the way, slide rail<br />
(1) onto shim (2) until rail is secure. Take the<br />
chain/belt and wrap it around the sprocket (3). Make<br />
1<br />
4<br />
10 Attach Sprocket Cover<br />
Place sprocket cover (1) on top of the opener (2),<br />
secure with screws (3).<br />
11 Assemble Header Sleeve<br />
Thread spring nut on carriage bolt until finger tight.<br />
Insert a screwdriver tip (1) into one of the slots of the<br />
nut ring (2) and brace it firmly against the header<br />
sleeve. Place an open end wrench (3) on the square<br />
end of the spring nut (4), slightly rotate nut about 1/4<br />
turn clockwise until nut ring (2) is released against<br />
header sleeve (5). This sets spring to optimum chain<br />
tension. Chain may slip off sprocket if chain/belt is too<br />
2<br />
3<br />
sure the teeth on the sprocket have engaged the<br />
chain/belt.<br />
3<br />
4<br />
loose. If chain does slip re-tighten spring nut by turing<br />
nut clockwise 1/2 turn. Do NOT overtighten<br />
chain/belt.<br />
INSTALLATION SECTION<br />
Wear protective goggles when working overhead to protect your eyes from injury.<br />
Disengage all existing garage door locks to avoid damage to the garage door.<br />
To avoid serious personal injury from entanglement, remove all ropes connected to the garage door<br />
before installing the opener.<br />
Installation of this product shall comply with ZH1/494, VDE 0700 Part 238, and VDE 0700 Part 1.<br />
It is recommended that the opener be installed 2,1m (7 feet) or more above the floor where space permits.<br />
12 Position the Header Bracket<br />
The header bracket must be rigidly fastened to a<br />
structural support of the garage. Reinforce the wall or<br />
ceiling with a 40mm (1-1/2") board if necessary.<br />
Failure to comply may result in improper operation of<br />
safety reverse system.<br />
You can attach the header bracket either to the header<br />
wall (1) or to the ceiling (3). Follow the instructions which<br />
will work best for your particular requirements. With the<br />
door closed, mark the vertical centerline (2) of the garage<br />
door. Extend line onto header wall above the door.<br />
Open door to highest point of travel. Draw an intersecting<br />
horizontal line (4) on header wall 5 cm (2") above high<br />
point to provide travel clearance for top edge of door.<br />
13 Install the Header Bracket<br />
5<br />
NOTE: Refer to vertical center and horizontal lines<br />
created in step 12 for proper placement of header<br />
bracket.<br />
A. Wall Mount: Center the header bracket (1) on the<br />
vertical center line (2) with the bottom edge of the<br />
header bracket on the horizontal line (4) (with the<br />
arrow pointing toward the ceiling). Mark all of the<br />
50mm<br />
(2")<br />
4<br />
2 1<br />
3 5<br />
150mm<br />
(6")<br />
1<br />
2<br />
header bracket holes (5). Drill 4,5mm (3/16") pilot<br />
3<br />
holes and fasten the header bracket with wood<br />
screws (3).<br />
A<br />
B<br />
B. Ceiling Mount: Extend vertical center line (2) onto<br />
the ceiling. Center the header bracket (1) on the<br />
vertical mark no more than 150mm (6") from the<br />
wall. Make sure the arrow is pointing toward the<br />
opener. Mark all of the header bracket holes (5). Drill<br />
4,5mm (3/16") pilot holes and fasten the header<br />
bracket with wood screws (3). For concrete ceiling<br />
mount, use concrete anchors provided.<br />
4-GB<br />
1<br />
4<br />
3<br />
1<br />
2<br />
2<br />
5<br />
1<br />
5<br />
2<br />
2<br />
1<br />
3<br />
3<br />
3<br />
1<br />
114A2910B-GB<br />
2