Venting the system<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

NOTE<br />

Hot fluids and hot vapour may occur.<br />

Fluid with air<br />

Flow direction<br />

Aerated fluid<br />

Venting valve<br />

Blowhole<br />

Air/fluid<br />

1. Route the blowhole (5) to the collector.<br />

2. Open the venting valve°(4).<br />

The separated air is drained from the vessel.<br />

3. Close the valve as soon as fluid <strong>com</strong>es out of the<br />

pipe.<br />

Operation and maintenance<br />

For safety reasons the fluid must be able to run out of<br />

the safety valve during the heating process.<br />

Do not close the safety valve.<br />

Check the unit before restarting it when the safety<br />

valve has been deployed (normally only occurs at start<br />

up).<br />

Problem free operation is only possible with open ball<br />

valves (position 0°. See section Start-up and inspection<br />

on page 14.<br />

Maintenance intervals<br />

When<br />

Flow meter can no longer<br />

be read off.<br />

Fault in the circulation<br />

pump.<br />

Activity<br />

Drain, flush and fill the system.<br />

Replace the circulation<br />

pump.<br />

GB<br />