New offset = T menu 1 - T surface<br />
Example: Use the floor sensor temperature value from menu<br />
1. If this value is 27°C and the floor surface thermometer<br />
shows 24°C, the new offset value will be 27-24 = 3.<br />
Change the offset from 4°C to 3°C.<br />
Push confirmation button several times (scroll through<br />
Menu structure) for leaving the Calibration mode to Normal<br />
mode<br />
6. Reset to factory settings.<br />
T menu1<br />
T surface<br />
set value floor sensor mode < > 23°C<br />
set value room sensor mode < > 20°C<br />
floor sensor offset value < > 4°C<br />
Reset: switch "off" the thermostat < >. Press < > and<br />
< > simultanously with switching "on" < > the<br />
thermostat "000" is displayed. Press < > and “CLR” is<br />
displayed. The thermostat is reset.<br />