The floor sensor has the following temperature / resistance<br />

values:<br />

15°C / 15,8 kΩ<br />

20°C / 12,5 kΩ<br />

25°C / 10,0 kΩ<br />

30°C / 8,04 kΩ<br />

35°C / 6,51 kΩ<br />

The floor sensor may be replaced by a new one. In the event<br />

of malfunction of the room sensor the entire thermostat<br />

must be replaced.<br />

5.3 Calibration of temperature < ><br />

If the desired temperature is not reached or if there is a<br />

difference between real floor/room temperature and the set<br />

value on the display, calibrate the thermostat.<br />

Push OK continuously for full 6 seconds to enter following<br />

Menu:<br />

Menu 1: < > read-out actual measured temperature<br />

Menu 2: < > calibration of the floor/room<br />

temperature<br />

Menu 1:<br />

Service read-out of actual measured temperature (only<br />

valid in floor sensing mode) < >:<br />

To check the actual measured temperature, push the<br />

confirmation button for 6 sec.<br />

In menu number 1 the<br />

measured temperature value is<br />

indicated on the display: infloor<br />

temperature in case of<br />

floor sensing mode < >.<br />

This value can be used to calibrate the floor surface<br />

temperature value to the set temperature value on the<br />

display. Push confirmation button several times (scroll<br />

through Menu structure) for leaving the Configuration mode<br />

to Normal mode<br />