12.07.2015 Views

Inhoud 1 Inleiding 2 Programmeren 3 Parameterbeschrijving

Inhoud 1 Inleiding 2 Programmeren 3 Parameterbeschrijving

Inhoud 1 Inleiding 2 Programmeren 3 Parameterbeschrijving

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ParameterlijstenFC 300 Programmeerhandleiding4.1.17 16-** Data-uitlezingenPar. <strong>Parameterbeschrijving</strong> Standaardwaarde 4-set-up Alleen Wijzigen Conversie-indexTypenr.FC 302 tijdensbedrijf16-0* Alg. status16-00 Stuurwoord 0 N/A All set-ups FALSE 0 V216-01 Referentie [Eenh.]0.000 ReferenceFeedbackUnitAll set-ups FALSE -3 Int3216-02 Referentie % 0.0 % All set-ups FALSE -1 Int1616-03 Statuswoord 0 N/A All set-ups FALSE 0 V216-05 Vrnste huid. waarde [%] 0.00 % All set-ups FALSE -2 N216-09 Standaard uitlez. 0.00 CustomReadoutUnit All set-ups FALSE -2 Int3216-1* Motorstatus16-10 Verm. [kW] 0.00 kW All set-ups FALSE 1 Int3216-11 Verm. [pk] 0.00 hp All set-ups FALSE -2 Int3216-12 Motorspanning 0.0 V All set-ups FALSE -1 Uint1616-13 Frequentie 0.0 Hz All set-ups FALSE -1 Uint1616-14 Motorstroom 0.00 A All set-ups FALSE -2 Int3216-15 Frequentie [%] 0.00 % All set-ups FALSE -2 N216-16 Koppel [Nm] 0.0 Nm All set-ups FALSE -1 Int1616-17 Snelh. [RPM] 0 RPM All set-ups FALSE 67 Int3216-18 Motor therm. 0 % All set-ups FALSE 0 Uint816-19 KTY-sensortemperatuur 0 °C All set-ups FALSE 100 Int1616-20 Motorhoek 0 N/A All set-ups TRUE 0 Uint1616-21 Torque [%] High Res. 0.0 % All set-ups FALSE -1 Int1616-22 Koppel [%] 0 % All set-ups FALSE 0 Int1616-25 Koppel [Nm] hoog 0.0 Nm All set-ups FALSE -1 Int3216-3* Status omvormer16-30 DC-aansluitsp. 0 V All set-ups FALSE 0 Uint1616-32 Remenergie/s 0.000 kW All set-ups FALSE 0 Uint3216-33 Remenergie/2 min. 0.000 kW All set-ups FALSE 0 Uint3216-34 Temp. koellich. 0 °C All set-ups FALSE 100 Uint816-35 Inverter therm. 0 % All set-ups FALSE 0 Uint816-36 Geïnv. nom. stroom ExpressionLimit All set-ups FALSE -2 Uint3216-37 Geïnv. max. ingangsstr. ExpressionLimit All set-ups FALSE -2 Uint3216-38 SL-controllerstatus 0 N/A All set-ups FALSE 0 Uint816-39 Temp. stuurkaart 0 °C All set-ups FALSE 100 Uint816-40 Logbuffer vol [0] Nee All set-ups TRUE - Uint816-41 LCP onderste statusreg 0 N/A All set-ups TRUE 0VisStr[50]16-49 Current Fault Source 0 N/A All set-ups x TRUE 0 Uint816-5* Ref. & terugk.16-50 Externe referentie 0.0 N/A All set-ups FALSE -1 Int1616-51 Pulsreferentie 0.0 N/A All set-ups FALSE -1 Int1616-52 Terugk. [Eenh]0.000 ReferenceFeedbackUnitAll set-ups FALSE -3 Int3216-53 Digi Pot referentie 0.00 N/A All set-ups FALSE -2 Int1616-57 Feedback [RPM] 0 RPM All set-ups FALSE 67 Int324 4MG.33.MA.10 – VLT ® is een gedeponeerd handelsmerk van Danfoss 195

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!