8Bijlageframe 314 StromingscontroleP1 P2 P3 P4108100Druk in [kPa]Pomp 100%Pomp 0%Pomp 100%Pomp 0%Voorwaarden:P3 groter dan P2 + 8 [kPa]P4 kleiner dan P3 - 4 [kPa]00 10 25 40 55Tijd in [s]frame 315 VermogensinstellingWeergave inhet display[%]Nominaal cv-vermogen bij 40/30 °C [kW]<strong>Nefit</strong> <strong>TopLine</strong>-toestellen25 kW 30 kW 45 kWL25 5,0 6,6 11,3L30 7,2 8,1 13,5L35 8,4 9,6 15,8L40 9,6 11,1 18,0L45 10,8 12,6 20,3L50 12,0 14,1 22,5L55 13,2 15,6 24,8L60 14,4 17,1 27,0L65 15,6 18,6 29,3L70 16,8 20,1 21,5L75 18,0 21,6 33,8L80 19,2 23,1 36,0L85 20,4 24,6 38,3L90 21,6 26,1 40,5L95 22,8 27,6 42,5L-- 23,5 29,2 45,0Het kleinste percentage is de stand voor laaglast.<strong>Nefit</strong> B.V. • http://www.nefit.nlWijzigingen op grond van technische verbeteringen voorbehouden!98 Service-instructie <strong>Nefit</strong> <strong>TopLine</strong> <strong>HR</strong>, <strong>TopLine</strong> Aquapower <strong>HR</strong>C en <strong>TopLine</strong> AquaPower Plus <strong>HR</strong>C • uitgave 07/2008