Materiaal( Voor metselwerk :H x L x B )Dikte (m)Thermischegeleidbaarheidλ (W/m.K)ThermischeweerstandR (m²K/W)Belang in %1 Pleisterwerk 0,008 0,520 0,015 0,37%2 mHollebetonmetselsteen0,19 0,678 0,280 6,87%8/1,4 19 x 29 x 193 Isolatie 0,08 0,023 3,478 85,33%4 Luchtspouw 0,03 0,085 2,09%5 bZichtbetonmetselsteen7,2 x 19,8 x 90,09 1,860 0,048 1,18%Oppervlakte weerstand interieur R si= 0,130 3,19%Oppervlakte weerstand exterieur R se= 0,040 0,98%Totale thermische weerstand R T( m²K/W ) = 4,0764 ← ø spouwhaken ( 4 of 5 mm ) → ∆Uf = 0,023Warmtedoorgangscoëfficient K of U ( W/m²K ) = 0,27