GB<br />

The risk with gas is that leaking gas is ignited, resulting<br />

in an explosion. As LPG has no distinct aroma, sulphur<br />

compounds are added that give a distinct, pungent smell,<br />

even when the concentration of gas is as low as one fifth<br />

of the lower explosion limit. The LPG burner usually works<br />

at a lower pressure than the pressure in the cylinder.<br />

Low pressure is obtained by allowing the LPG to pass<br />

through a regulator.<br />

7:0 Troubleshooting<br />

Here is a brief troubleshooting chart that may be of help<br />

in the event of simple faults.<br />

The ignition spark comes but the boiler does<br />

not start<br />

1. Check gas supply.<br />

2. Is the service tap fully open<br />

3. If the boiler has been out of use for a while or if the gas<br />

cylinder has been changed, it takes longer to ignite<br />

than normal.<br />

4. The thermostat knob must be pushed down as far as<br />

it will go when starting.<br />

5. If this does not help, contact your service workshop.<br />

No ignition spark<br />

1. Check that there is a 12-volt supply to the boiler.<br />

2. Check the fuse on the boiler is intact.<br />

3. Check that the warning light for the ignition spark is<br />

flashing.<br />

4. Remove the lower front cover. Check that the cables<br />

to the ignition transformer (small black box just under<br />

the control panel) and the microswitch (under the<br />

thermostat) are properly attached and that there is no<br />

corrosion on the cable clips.<br />

5. If this does not help, contact your service workshop.<br />

The boiler ignites but goes out when the thermostat<br />

knob is released<br />

1. Repeat the ignition procedure as per instructions in<br />

chapter 2:2 (wait 3 minutes before igniting the boiler<br />

again). Make sure that the thermostat knob is pushed<br />

down as far as it will go and hold it in position for 20-30<br />

seconds after the warning light has gone out.<br />

2. Check that the pilot flame comes into contact with<br />

the tip of the thermoelement (to the right of the pilot<br />

burner).<br />

3. If this does not help, contact your service workshop.<br />

The boiler boils<br />

1. Turn the thermostat knob to 1 (lowest system temperature)<br />

and check that the main flame goes out, as it<br />

should.<br />

2. Check that the sensor is secured correctly. It should<br />

be attached to the body of the boiler by a spring clip<br />

just under the control box with heat-conducting putty<br />

in between.<br />

3. If this does not help, contact your service workshop.<br />

Vibrations in the circulation pump (12-volt)<br />

1. Release the nut holding the circulation pump.<br />

2. Turn the pump a little and tighten up the nut again.<br />

3. Check that the rubber connection between the motor<br />

and the shaft is straight and does not wobble when in<br />

motion.<br />

4. Check that there is no obstruction in the way of the<br />

pump at the bottom of the expansion vessel.<br />

5. If this does not help, contact your service workshop.<br />

Noise in the motor of the circulation pump (12-<br />

volt)<br />

1. Drop a drop of sewing machine oil into the centre hole<br />

at the top of the motor.<br />

2. If the noise does not disappear or returns after a while,<br />

the motor should be replaced.<br />

Circulation pump (12-volt) will not start<br />

1. Check that the slider on the room thermostat is in ”ON”<br />

position.<br />

2. Check that the temperature shown on the room thermostat<br />

is higher than inside the vehicle.<br />

3. Check that the changeover switch on the control panel<br />

for the circulation pump is on ”12-volt pump”.<br />

4. Remove the circulation pump and check that the cables<br />

are properly secured, and that there is a 12-volt<br />

supply.<br />

5. If this does not help, contact your service workshop.<br />

Incorrect temperature on the room thermostat<br />

1. Check by using an accurate thermometer inside the<br />

vehicle.<br />

2. Remove the cover from the room thermostat (press in<br />

the pin on the left-hand side and pull the cover straight<br />

out).<br />

3. Pull out the knob and move it as many degrees up or<br />

down as it indicated wrongly, and press it into place<br />

again.<br />

4. Replace the cover and check that the temperature<br />

agrees with the scale on the room thermostat.<br />

The immersion heater has stopped working<br />

1. Check that there is power (230/240 volts) in the wall<br />

socket.<br />

2. Check that the relays on the immersion heater switch<br />

on (a gentle click should be heard).<br />

3. Check whether the overheating protection has triggered.<br />

If so, press in the button on the side of the<br />

cover.<br />

4. If this does not help, contact the service workshop.<br />

Insufficient hot water<br />

1. Check that boiler thermostat is set on maximum position.<br />

8:0 Guarantee<br />

Alde Internationalʼs guarantee applies for one year from<br />

date of delivery and covers material defects and manufacturing<br />

defects only, on condition that above instructions<br />

have been adhered to.<br />

NB. Use only original parts from Alde as spares.<br />