The risk with gas is that leaking gas is ignited, resulting<br />
in an explosion. As LPG has no distinct aroma, sulphur<br />
compounds are added that give a distinct, pungent smell,<br />
even when the concentration of gas is as low as one fifth<br />
of the lower explosion limit. The LPG burner usually works<br />
at a lower pressure than the pressure in the cylinder.<br />
Low pressure is obtained by allowing the LPG to pass<br />
through a regulator.<br />
7:0 Troubleshooting<br />
Here is a brief troubleshooting chart that may be of help<br />
in the event of simple faults.<br />
The ignition spark comes but the boiler does<br />
not start<br />
1. Check gas supply.<br />
2. Is the service tap fully open<br />
3. If the boiler has been out of use for a while or if the gas<br />
cylinder has been changed, it takes longer to ignite<br />
than normal.<br />
4. The thermostat knob must be pushed down as far as<br />
it will go when starting.<br />
5. If this does not help, contact your service workshop.<br />
No ignition spark<br />
1. Check that there is a 12-volt supply to the boiler.<br />
2. Check the fuse on the boiler is intact.<br />
3. Check that the warning light for the ignition spark is<br />
flashing.<br />
4. Remove the lower front cover. Check that the cables<br />
to the ignition transformer (small black box just under<br />
the control panel) and the microswitch (under the<br />
thermostat) are properly attached and that there is no<br />
corrosion on the cable clips.<br />
5. If this does not help, contact your service workshop.<br />
The boiler ignites but goes out when the thermostat<br />
knob is released<br />
1. Repeat the ignition procedure as per instructions in<br />
chapter 2:2 (wait 3 minutes before igniting the boiler<br />
again). Make sure that the thermostat knob is pushed<br />
down as far as it will go and hold it in position for 20-30<br />
seconds after the warning light has gone out.<br />
2. Check that the pilot flame comes into contact with<br />
the tip of the thermoelement (to the right of the pilot<br />
burner).<br />
3. If this does not help, contact your service workshop.<br />
The boiler boils<br />
1. Turn the thermostat knob to 1 (lowest system temperature)<br />
and check that the main flame goes out, as it<br />
should.<br />
2. Check that the sensor is secured correctly. It should<br />
be attached to the body of the boiler by a spring clip<br />
just under the control box with heat-conducting putty<br />
in between.<br />
3. If this does not help, contact your service workshop.<br />
Vibrations in the circulation pump (12-volt)<br />
1. Release the nut holding the circulation pump.<br />
2. Turn the pump a little and tighten up the nut again.<br />
3. Check that the rubber connection between the motor<br />
and the shaft is straight and does not wobble when in<br />
motion.<br />
4. Check that there is no obstruction in the way of the<br />
pump at the bottom of the expansion vessel.<br />
5. If this does not help, contact your service workshop.<br />
Noise in the motor of the circulation pump (12-<br />
volt)<br />
1. Drop a drop of sewing machine oil into the centre hole<br />
at the top of the motor.<br />
2. If the noise does not disappear or returns after a while,<br />
the motor should be replaced.<br />
Circulation pump (12-volt) will not start<br />
1. Check that the slider on the room thermostat is in ”ON”<br />
position.<br />
2. Check that the temperature shown on the room thermostat<br />
is higher than inside the vehicle.<br />
3. Check that the changeover switch on the control panel<br />
for the circulation pump is on ”12-volt pump”.<br />
4. Remove the circulation pump and check that the cables<br />
are properly secured, and that there is a 12-volt<br />
supply.<br />
5. If this does not help, contact your service workshop.<br />
Incorrect temperature on the room thermostat<br />
1. Check by using an accurate thermometer inside the<br />
vehicle.<br />
2. Remove the cover from the room thermostat (press in<br />
the pin on the left-hand side and pull the cover straight<br />
out).<br />
3. Pull out the knob and move it as many degrees up or<br />
down as it indicated wrongly, and press it into place<br />
again.<br />
4. Replace the cover and check that the temperature<br />
agrees with the scale on the room thermostat.<br />
The immersion heater has stopped working<br />
1. Check that there is power (230/240 volts) in the wall<br />
socket.<br />
2. Check that the relays on the immersion heater switch<br />
on (a gentle click should be heard).<br />
3. Check whether the overheating protection has triggered.<br />
If so, press in the button on the side of the<br />
cover.<br />
4. If this does not help, contact the service workshop.<br />
Insufficient hot water<br />
1. Check that boiler thermostat is set on maximum position.<br />
8:0 Guarantee<br />
Alde Internationalʼs guarantee applies for one year from<br />
date of delivery and covers material defects and manufacturing<br />
defects only, on condition that above instructions<br />
have been adhered to.<br />
NB. Use only original parts from Alde as spares.<br />