Water leakage<br />

Drainage pipe blocked or broken<br />

Wrap <strong>of</strong> refrigerant pipe joint is not close<br />

enough.<br />

Change drainage pipe<br />

Re-wrap and make it tight.<br />

Fan <strong>of</strong> indoor unit contacts other parts.<br />

Adjust fan location.<br />

Foreign object in indoor unit<br />

Take out the foreign object.<br />

Compressor shakes too much.<br />

Adjust support washer <strong>of</strong> compressor, and<br />

tighten loosen screws.<br />

Abnormal sound<br />

and shake<br />

Touch <strong>of</strong> pipeline <strong>of</strong> outdoor unit<br />

Touch <strong>of</strong> inner plates<br />

Separate the touching pipeline.<br />

1. Tighten connect screw.<br />

2. Stick absorbing clay between plates.<br />

Louver <strong>of</strong> outdoor unit touched outer<br />

case.<br />

Abnormal sound inside compressor<br />

Adjust location <strong>of</strong> louver.<br />

Change compressor<br />

Abnormal solenoid sound from 4-way<br />

valve when heating<br />

Circuit-short inside solenoid <strong>of</strong> the valve<br />

and change the solenoid valve.<br />

There are no heating malfunctions in the above for the cooling only unit.