Vereenvoudigd CNC-circuit.<br />

J15 CNC<br />

14 pin CPC<br />

rear panel<br />

SUSTAINED START / STOP<br />

MOMENTARY START / STOP<br />

STOP<br />

TB1-4<br />

Remote CC Pot connections<br />

Art # A-09191<br />

START / STOP<br />

START<br />

.<br />

.<br />

J15<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

POT<br />

.<br />

TB1<br />

11<br />

10<br />

9<br />

TB1-5<br />

TB1-6<br />

TB1-5<br />

TB1-6<br />

E-STOP Ret (-)<br />

E-STOP input (+)<br />

OK2<br />

STOP (NC)<br />

START/STOP Ret (-)<br />

START/STOP OR START LATCH (+)<br />

DIVIDED ARC V (-)<br />

DIVIDED ARC V (+)<br />

Remote Analog Current Control ret (-)<br />

Remote Analog Current Control input (+)<br />

Supply for remote CC pot, +10 VDC @ 10ma.<br />

OK2<br />

Plasma Marking Remote<br />

SW or Relay activated.<br />

(use with DFC 3000 only)<br />

OK TO MOVE<br />

output<br />

(contacts or<br />

DC Volts)<br />

HOLD START (-)<br />

HOLD START (+)<br />

PREFLOW ON (-)<br />

PREFLOW ON (+)<br />

PILOT ON<br />

output<br />

(Contacts)<br />

OK to MOVE (-)<br />

OK to MOVE (+)<br />

Remote Analog Current Control (-)<br />

START / STOP (+)<br />

START / STOP (-)<br />

Remote Analog Current Control (+)<br />

Divided Arc V (-)<br />

SC 11 Comm Ref<br />

Divided Arc V (+)<br />

ARC V_100K (+)<br />

ARC V_100K (-)<br />

OK to MOVE (-)<br />

OK to MOVE (+)<br />

Ultra-cUt <strong>200</strong><br />

Handleiding 0-5133NL A-11 BIJLAGE<br />

TB1<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

TB2<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

J1<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

J4<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

TB3<br />

1<br />

2<br />

I1<br />

CCM Module<br />

I1<br />

Active LOW Logic Input<br />

Active LOW Logic Input<br />

Active LOW Logic Input<br />

+10 VDC @ 10ma.<br />

OK2- Suplemental<br />

low voltage (24V)<br />

OK to Move<br />

SW11<br />

3<br />

1<br />

2<br />

Active LOW Logic Input<br />

Active LOW Logic Input<br />

PSR<br />

7<br />

- 8<br />

+ 1<br />

OK to Move<br />

Active LOW Logic Input<br />

(not isolated)<br />

All I-O except Plasma Marking is isolated<br />

from plasma power supply circuits. TB3 is<br />

not isolated. Activate with relay or switch<br />

isolated from other circuits.<br />

6<br />

2<br />

ALL SW OFF for 50:1 (default)<br />

SW12-1 ON = 16.7:1 (SC-11)<br />

SW12-2 ON = 30:1<br />

SW12-3 ON = 40:1<br />

SW12-4 ON = 25:1<br />

I1<br />

To CPU PCB<br />

Analog Input<br />

1K<br />

1K<br />

1K<br />

SW12-1<br />

1 8<br />

SW12-2<br />

2 7<br />

SW6<br />

1<br />

2<br />

3<br />

5<br />

4<br />

6<br />

ARC V (+)<br />

ARC V (-)<br />

SW12-3<br />

3 6<br />

SW12-4<br />

4 5<br />

Input Circuit<br />

Common<br />

(isolated)<br />

I1<br />

+16 to 18 VDC<br />

(isolated)