WTCB<br />

EEN UITGAVE VAN HET WETENSCHAPPELIJK EN TECHNISCH CENTRUM VOOR HET BOUWBEDRIJF<br />

RAPPORT TOEPASSING VAN<br />

DE EUROCODES OP<br />

HET ONTWERP VAN<br />

BUITENSCHRIJNWERK<br />

(aangepast in oktober 2010)<br />

WTCB-Rapport nr. 11 – 2009<br />

North Galaxy (Jaspers, eyers & partNers – MoNtois partNers architects – art & Built)


RappoRt <strong>Toepassing</strong> <strong>van</strong><br />

<strong>de</strong> euroco<strong>de</strong>s <strong>op</strong><br />

<strong>het</strong> <strong>ontwerp</strong> <strong>van</strong><br />

<strong>buitenschrijnwerk</strong><br />

Samenstelling <strong>van</strong> <strong>het</strong> redactiecomité<br />

Le<strong>de</strong>n Mevr. A. Minne, Saint-Gobain, Brussel<br />

De heren C. Clauwaert, SECO, Brussel<br />

C. Cornu, WTCB, Brussel<br />

F. Coveliers, Confe<strong>de</strong>ratie Bouw, Brussel<br />

J. De Keyser, SECO, Brussel<br />

F. Desmet, Sapa, Lan<strong>de</strong>n<br />

Y. Dupont, Atelier du verre, Alleur<br />

P. Keukeleire, BEEM, Brussel<br />

C. Martinez, Belgometal-Permasteelisa, Gavere<br />

G. Ramaekers, Bouwunie, Brussel<br />

D. Raymaekers, Glaverbel, Brussel<br />

P. Spehl, SECO, Brussel<br />

K. Van <strong>de</strong>n Bergh, Reynaers Aluminium, Duffel<br />

J. Vandommele, Aluminium Center, Zellik<br />

P. Willems, Reynaers Aluminium, Duffel<br />

M. Wagneur, WTCB, Brussel<br />

Redacteur en animator De heer E. Dupont, WTCB, Brussel<br />

WETEnsChappElijk En TEChnisCh CEnTrum voor hET BouWBEdrijf<br />

wtcb, inrichting erkend bij toepassing <strong>van</strong> <strong>de</strong> besluitwet <strong>van</strong> 30 januari 1947<br />

Maatschappelijke zetel : Lombardstraat 42 te 1000 brussel<br />

Dit is een publicatie <strong>van</strong> wetenschappelijke aard. De bedoeling er<strong>van</strong> is <strong>de</strong> resultaten <strong>van</strong> <strong>het</strong><br />

bouwon<strong>de</strong>rzoek uit binnen- en buitenland te helpen versprei<strong>de</strong>n.<br />

Het, zelfs ge<strong>de</strong>eltelijk, overnemen of vertalen <strong>van</strong> <strong>de</strong> tekst <strong>van</strong> dit Rapport is slechts toegelaten<br />

na schriftelijk akkoord <strong>van</strong> <strong>de</strong> verantwoor<strong>de</strong>lijke uitgever.<br />

u1<br />

WTCB-Rapport nr. 11 – 2009


INHOUD<br />

1. VOORWERP VAN DIT RAPPORT.............................................................................................. 7<br />

2. BASISBEGRIPPEN......................................................................................................................... 8<br />

2.1. Definitie <strong>van</strong> <strong>de</strong> grenstoestan<strong>de</strong>n ............................................................................................ 8<br />

2.1.1. Uiterste grenstoestan<strong>de</strong>n (UGT).................................................................................... 8<br />

2.1.2. Gebruiksgrenstoestan<strong>de</strong>n (GGT)................................................................................... 8<br />

2.2. Terminologie............................................................................................................................. 8<br />

2.2.1. Belastingen.................................................................................................................. 8<br />

2.2.1.1. Blijven<strong>de</strong> (permanente) belasting (G) ................................................................ 9<br />

2.2.1.2. Veran<strong>de</strong>rlijke (variabele) belasting (Q).............................................................. 9<br />

2.2.1.3. Toevallige (acci<strong>de</strong>ntele) belasting (A) ............................................................... 9<br />

2.2.1.4. Rekenwaar<strong>de</strong> <strong>van</strong> een belasting of een belastingscombinatie (Fd(x)) .................... 9<br />

2.2.2. Partiële coëfficiënten.................................................................................................... 9<br />

2.2.3. Combinatiecoëfficiënten............................................................................................... 9<br />

2.2.4. De hoofdconstructie ................................................................................................... 10<br />

2.2.5. Secundaire constructies .............................................................................................. 10<br />

2.2.6. Vulelementen ............................................................................................................ 11<br />

2.2.7. Gevolgklassen ........................................................................................................... 11<br />

2.2.8. De borstweringsfunctie in een gevel ............................................................................ 12<br />

3. BEPERKINGEN VAN DEZE SPECIFICATIES....................................................................... 13<br />

3.1. <strong>Toepassing</strong>sgebied .................................................................................................................. 13<br />

3.2. Belastingen en combinaties.................................................................................................... 13<br />

3.3. Controle in <strong>de</strong> grenstoestan<strong>de</strong>n <strong>van</strong> <strong>buitenschrijnwerk</strong>elementen.................................... 14<br />

3.4. Controle <strong>van</strong> <strong>de</strong> grenstoestan<strong>de</strong>n ......................................................................................... 15<br />

3.4.1. Schrijnwerk en grenstoestan<strong>de</strong>n .................................................................................. 15<br />

3.4.1.1. Het geval <strong>van</strong> vensters en dakvensters ............................................................. 15<br />

3.4.1.2. Het geval <strong>van</strong> lichte constructies : gordijngevels en glazen daken...................... 15<br />

3.4.1.3. Het geval <strong>van</strong> vulelementen ............................................................................ 15<br />

3.4.1.4. Het geval <strong>van</strong> verandaconstructies................................................................... 15<br />

3.4.1.4.1. Autonome constructies ..................................................................... 15<br />

3.4.1.4.2. Constructies die door één zij<strong>de</strong> <strong>van</strong> <strong>het</strong> gebouw gestabiliseerd wor<strong>de</strong>n 16<br />

3.4.1.4.3. Constructies die door minstens twee zij<strong>de</strong>n <strong>van</strong> <strong>het</strong> gebouw<br />

gestabiliseerd wor<strong>de</strong>n....................................................................... 16<br />

3.4.1.4.4. Verandacategorieën voor <strong>de</strong> structurele berekening. ........................... 17<br />

3.4.1.4.4.1. Categorie 1....................................................................... 17<br />

3.4.1.4.4.2. Categorie 2....................................................................... 17<br />

3.4.1.4.4.3. Categorie 3....................................................................... 18<br />

3.4.1.4.4.4. Aanvullen<strong>de</strong> voorschriften............................................... 18<br />

3.4.2. Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n ................................................................................. 18<br />

4. BELASTINGEN............................................................................................................................. 19<br />

4.1. Windbelasting......................................................................................................................... 19<br />

4.1.1. Gebruiksduur en terugkeerperio<strong>de</strong> <strong>van</strong> <strong>de</strong> wind (cprob)................................................... 19<br />

4.1.2. Uitdrukking <strong>van</strong> <strong>de</strong> winddruk ..................................................................................... 19<br />

4.1.2.1. Bepaling <strong>van</strong> <strong>de</strong> referentiehoogte voor <strong>de</strong> wind .............................................. 20<br />

4.1.2.1.1. Inleiding.......................................................................................... 20<br />

4.1.2.1.2. Laag referentieniveau z = 0 voor <strong>de</strong> bepaling <strong>van</strong> ze ........................... 20<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

3


4.1.2.1.3. Hoog referentieniveau z voor <strong>de</strong> bepaling <strong>van</strong> ze ................................ 22<br />

4.1.2.1.3.1. Wan<strong>de</strong>n on<strong>de</strong>r <strong>de</strong> wind (on<strong>de</strong>rdruk) ................................ 22<br />

4.1.2.1.3.2. Wan<strong>de</strong>n tegen <strong>de</strong> wind (overdruk)................................... 22<br />

4.1.2.1.3.3. Nabijheid <strong>van</strong> gebouwen met zeer grote hoogte.............. 24<br />

4.1.2.2. Ruwheidscategorie <strong>van</strong> <strong>het</strong> terrein................................................................... 25<br />

4.1.2.3. Hoeksector en terreinruwheidscategorie........................................................... 26<br />

4.1.2.3.1. Windrichting ................................................................................... 27<br />

4.1.2.3.2. Nominale hoeksector........................................................................ 27<br />

4.1.2.3.3. Hoeksector <strong>van</strong> 30°.......................................................................... 27<br />

4.1.2.3.4. Straal <strong>van</strong> <strong>de</strong> hoeksector................................................................... 27<br />

4.1.2.3.5. Procedure voor <strong>de</strong> bepaling <strong>van</strong> <strong>de</strong> ruwheidscategorie ........................ 28<br />

4.1.2.4. Bepaling <strong>van</strong> <strong>de</strong> coëfficiënt ce(z). qref 50jaar ........................................................ 29<br />

4.1.2.5. Bepaling <strong>van</strong> <strong>de</strong> drukcoëfficiënt cp .................................................................. 31<br />

4.1.2.5.1. Definitie <strong>van</strong> cp................................................................................ 31<br />

4.1.2.5.2. Waar<strong>de</strong>n voor <strong>de</strong> buitendrukcoëfficiënt cpe......................................... 32<br />

4.1.2.5.3. Waar<strong>de</strong>n voor <strong>de</strong> binnendrukcoëfficiënt cpi ........................................ 50<br />

4.1.2.5.3.1. Druk uitgeoefend <strong>op</strong> enkelwandige muren en daken....... 50<br />

4.1.2.5.3.2. Druk uitgeoefend <strong>op</strong> meerwandige muren en daken ....... 52<br />

4.1.2.5.4. Specifiek geval <strong>van</strong> kleine constructies in reliëf <strong>op</strong> gevels of daken..... 54<br />

4.2. Belasting veroorzaakt door <strong>het</strong> eigengewicht ...................................................................... 55<br />

4.3. Belasting veroorzaakt door sneeuw ...................................................................................... 57<br />

4.3.1. Daken met één dakschild............................................................................................ 58<br />

4.3.2. Daken met twee dakschil<strong>de</strong>n....................................................................................... 59<br />

4.3.3. Daken tegen een grote <strong>op</strong>gaan<strong>de</strong> constructie ................................................................ 59<br />

4.4. Belastingen veroorzaakt door <strong>de</strong> borstweringsfunctie........................................................ 61<br />

4.4.1. Inleiding.................................................................................................................... 61<br />

4.4.2. Beoor<strong>de</strong>lingsparameters ............................................................................................. 61<br />

4.4.2.1. Beschermingshoogte (H) ................................................................................ 61<br />

4.4.2.2. Valhoogte (hc)................................................................................................ 61<br />

4.4.2.3. Referentiehoogte voor <strong>de</strong> beschermingshoogte (h)............................................ 61<br />

4.4.2.4. Toegankelijkheid <strong>van</strong> <strong>de</strong> gevel ........................................................................ 61<br />

4.4.2.5. Belastingen <strong>op</strong> een gevel die een borstweringsfunctie vervult............................ 62<br />

4.4.2.5.1. Statische veran<strong>de</strong>rlijke belastingen.................................................... 62<br />

4.4.2.5.1.1. Rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> statische belastingen ...................... 62<br />

4.4.2.5.1.2. Controle <strong>van</strong> <strong>de</strong> statische belastingen door proeven........ 64<br />

4.4.2.5.2. Dynamische belastingen ................................................................... 64<br />

4.4.2.5.3. Vereenvoudigen<strong>de</strong> aanbevelingen ..................................................... 65<br />

4.4.2.5.4. Positie <strong>van</strong> <strong>de</strong> statische en dynamische belastingen ............................ 65<br />

4.4.2.5.4.1. Dwarsregel <strong>op</strong> <strong>de</strong> beschermingshoogte H........................ 65<br />

4.4.2.5.4.2. Dwarsregel on<strong>de</strong>r <strong>de</strong> beschermingshoogte H .................. 66<br />

4.4.2.5.4.3. Geen dwarsregel of dwarsregel boven <strong>de</strong><br />

beschermingshoogte H..................................................... 67<br />

4.4.2.6. Controleprogramma, rekening hou<strong>de</strong>nd met <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n ................ 68<br />

4.4.2.6.1. Algemeenhe<strong>de</strong>n ............................................................................... 68<br />

4.4.2.6.2. Steunmuur of tegengevel <strong>op</strong> een hoogte groter dan of gelijk aan H...... 68<br />

4.4.2.6.3. Hoogte <strong>van</strong> een steunmuur of <strong>van</strong> een tegengevel indien h < H en voor<br />

een valhoogte hc ≤ 1,50 m................................................................. 69<br />

4.4.2.6.4. Hoogte <strong>van</strong> een steunmuur of <strong>van</strong> een tegengevel indien h < H en voor<br />

een valhoogte hc > 1,50 m................................................................. 70<br />

4.4.2.6.4.1. Geval <strong>van</strong> schrijnwerk zon<strong>de</strong>r <strong>op</strong>engaan<strong>de</strong> vleugels on<strong>de</strong>r<br />

<strong>de</strong> hoogte H...................................................................... 70<br />

4.4.2.6.4.2. Geval <strong>van</strong> schrijnwerk met <strong>op</strong>engaan<strong>de</strong> vleugels............ 71<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

4


4.4.2.6.5. Samenvatten<strong>de</strong> tabellen voor <strong>de</strong> beoor<strong>de</strong>ling <strong>van</strong> <strong>de</strong> borstwerings-<br />

functie............................................................................................. 72<br />

4.5. Ontbinding <strong>van</strong> <strong>de</strong> belastingen.............................................................................................. 77<br />

4.5.1. De wind .................................................................................................................... 77<br />

4.5.2. Het eigengewicht ....................................................................................................... 77<br />

4.5.3. Sneeuw ..................................................................................................................... 77<br />

4.5.4. Belastingen veroorzaakt door <strong>de</strong> borstweringsfunctie ................................................... 77<br />

4.6. Rekenwaar<strong>de</strong> voor <strong>de</strong> belastingen, voor hun combinaties en criteria voor <strong>de</strong><br />

grenstoestan<strong>de</strong>n...................................................................................................................... 78<br />

4.6.1. In aanmerking nemen <strong>van</strong> <strong>het</strong> gunstige effect <strong>van</strong> <strong>de</strong> blijven<strong>de</strong> (permanente) en<br />

veran<strong>de</strong>rlijke (variabele) belastingen ........................................................................... 78<br />

4.6.2. Geval <strong>van</strong> gevels........................................................................................................ 79<br />

4.6.2.1. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>de</strong> winddruk Fd(w)............... 79<br />

4.6.2.2. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht Fd(gk )....... 79<br />

4.6.2.3. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong><br />

borstwering (Ab), <strong>de</strong> wind (w) en <strong>het</strong> eigengewicht (gk) .................................... 83<br />

4.6.3. Geval <strong>van</strong> daken en hellen<strong>de</strong> gevels ............................................................................ 87<br />

4.6.3.1. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong> wind en <strong>het</strong><br />

eigengewicht Fd(w,gk) .................................................................................... 87<br />

4.6.3.2. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door sneeuw en <strong>het</strong><br />

eigengewicht Fd(gk, sk).................................................................................... 90<br />

4.6.3.3. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong> wind, sneeuw en<br />

<strong>het</strong> eigengewicht Fd(gk, w, sk).......................................................................... 90<br />

4.6.3.4. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong><br />

borstweringsfunctie, <strong>het</strong> eigengewicht en <strong>de</strong> wind Fd(Ab, gk, w)......................... 97<br />

4.6.3.4.1. Geval <strong>van</strong> stijlen .............................................................................. 97<br />

4.6.3.4.2. Geval <strong>van</strong> dwarsregels...................................................................... 98<br />

4.6.3.4.3. Geval <strong>van</strong> vulpanelen en hun bevestiging .......................................... 98<br />

4.6.3.4.4. Belastingscombinatie veroorzaakt door <strong>de</strong> borstweringsfunctie, door <strong>het</strong><br />

eigengewicht en <strong>de</strong> wind .................................................................. 99<br />

4.6.3.5. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong><br />

borstweringsfunctie, <strong>het</strong> eigengewicht en sneeuw Fd(Ab, gk,sk) .......................... 99<br />

5. ONTWERPWAARDEN VAN DE MATERIALEN (EENHEDEN N EN mm) ..................... 103<br />

6. REFERENTIEDOCUMENTEN ................................................................................................ 106<br />

Bijlage 1 Referentiesnelheid <strong>van</strong> <strong>de</strong> wind vb,0 ................................................................................107<br />

Bijlage 2 Bepaling <strong>van</strong> <strong>de</strong> meest ongunstige buitendrukcoëfficiënten cpe voor een gevel ....................... 117<br />

Bijlage 3 Bepaling <strong>van</strong> <strong>de</strong> meest ongunstige buitendrukcoëfficiënten cpe voor daken met één enkel<br />

dakschild .................................................................................................................................................. 122<br />

Bijlage 4 Bepaling <strong>van</strong> <strong>de</strong> meest ongunstige buitendrukcoëfficiënten cpe voor daken met twee dakschil<strong>de</strong>n<br />

.................................................................................................................................................... 126<br />

Bijlage 5 Berekening <strong>van</strong> <strong>de</strong> gemid<strong>de</strong>l<strong>de</strong> elasticiteitsmodulus Em voor <strong>de</strong> dimensionering <strong>van</strong> houten<br />

schrijnwerk............................................................................................................................................... 132<br />

Bijlage 6 Illustratief voorbeeld <strong>van</strong> <strong>het</strong> gunstige of ongunstige effect <strong>van</strong> <strong>de</strong> belasting <strong>op</strong> <strong>de</strong> berekening<br />

<strong>van</strong> een secundaire constructie................................................................................................................. 134<br />

Bijlage 7 Berekening <strong>van</strong> <strong>het</strong> glas............................................................................................................ 138<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

5


Waarschuwing<br />

Stabiliteitsberekeningen in <strong>het</strong> algemeen, en <strong>van</strong> <strong>de</strong> stabiliteit <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

in <strong>het</strong> bijzon<strong>de</strong>r, vereisen specifieke kwalificaties en een dito kennis. De <strong>ontwerp</strong>er<br />

dient hierover te beschikken en zich er<strong>van</strong> te vergewissen of <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n<br />

toelaten om naar dit Rapport te verwijzen. Vermits dit document een normaal<br />

gebruik <strong>van</strong> <strong>het</strong> <strong>buitenschrijnwerk</strong> beoogt, moeten alle niet-conventionele<br />

belastingen en gebruiken er<strong>van</strong> <strong>het</strong> voorwerp uitmaken <strong>van</strong> bijkomen<strong>de</strong> specificaties<br />

die aangepast zijn aan <strong>het</strong> risico dat men wil <strong>de</strong>kken.<br />

Het voorliggen<strong>de</strong> Rapport berust <strong>op</strong> <strong>de</strong> stand <strong>van</strong> <strong>de</strong> normalisatie <strong>op</strong> <strong>het</strong> ogenblik<br />

<strong>van</strong> zijn publicatie. De erin <strong>op</strong>genomen informatie kan dus on<strong>de</strong>rhevig zijn aan<br />

eventuele toekomstige wijzigingen.<br />

Ondanks <strong>het</strong> feit dat men <strong>het</strong> in <strong>de</strong> Euroco<strong>de</strong>s gewoonlijk heeft over <strong>de</strong><br />

bezwijkgrenstoestan<strong>de</strong>n (BGT), hebben we er in dit document voor ge<strong>op</strong>teerd om<br />

<strong>de</strong>ze aan te dui<strong>de</strong>n met <strong>de</strong> term uiterste grenstoestan<strong>de</strong>n (UGT). De afkorting BGT<br />

wordt in bepaal<strong>de</strong> an<strong>de</strong>re naslagwerken immers gehanteerd om <strong>de</strong><br />

bruikbaarheidsgrenstoestan<strong>de</strong>n (d.i. <strong>de</strong> gebruiksgrenstoestan<strong>de</strong>n of GGT) aan te<br />

dui<strong>de</strong>n.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

6


1. VOORWERP VAN DIT RAPPORT<br />

De Euroco<strong>de</strong>s hebben tot doel te helpen bij <strong>de</strong> dimensionering <strong>van</strong> alle constructietypes –<br />

gaan<strong>de</strong> <strong>van</strong> kunstwerken tot gebouwen – voor zover <strong>de</strong>ze <strong>op</strong>getrokken wer<strong>de</strong>n met traditionele<br />

bouwmaterialen.<br />

Hiertoe wordt een beroep gedaan <strong>op</strong> <strong>de</strong> semi-probabilistische metho<strong>de</strong>, tenein<strong>de</strong> een<br />

aanvaardbaar betrouwbaarheidsniveau te bepalen voor <strong>de</strong> levensduur <strong>van</strong> <strong>de</strong> constructie. De<br />

partiële-coëfficiëntenmetho<strong>de</strong> is een toepassing <strong>van</strong> <strong>de</strong> semi-probabilistische metho<strong>de</strong>. Hierbij<br />

wor<strong>de</strong>n er partiële factoren <strong>op</strong> <strong>de</strong> belastingen en <strong>de</strong> weerstan<strong>de</strong>n voorgesteld, die toelaten om <strong>de</strong><br />

gewenste betrouwbaarheid ten aanzien <strong>van</strong> <strong>het</strong> beschouw<strong>de</strong> constructietype te waarborgen.<br />

Dit Rapport vormt een toepassingsdocument <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s voor alle <strong>buitenschrijnwerk</strong>types.<br />

Het gaat hier met name om :<br />

- gevel- en dakvensters<br />

- gordijngevels<br />

- gevels <strong>van</strong> structureel gelijmd glas (SGG)<br />

- veranda’s en glazen daken.<br />

Het beschrijft <strong>de</strong> verschillen<strong>de</strong> grenstoestan<strong>de</strong>n en hun criteria, <strong>de</strong> waar<strong>de</strong>n voor <strong>de</strong> belastingen,<br />

<strong>de</strong> belastingscombinaties en <strong>de</strong> coëfficiënten die er<strong>op</strong> <strong>van</strong> toepassing zijn, evenals <strong>de</strong><br />

karakteristieke coëfficiënten <strong>van</strong> <strong>de</strong> courant gebruikte materialen.<br />

Zodoen<strong>de</strong> reikt <strong>het</strong> <strong>de</strong> <strong>ontwerp</strong>er <strong>van</strong> <strong>de</strong>ze bouwwerken alle elementen aan die nodig zijn voor<br />

<strong>het</strong> dimensioneren <strong>van</strong> <strong>de</strong> verankeringen, <strong>de</strong> constructies en <strong>de</strong> vulpanelen bij een blootstelling<br />

aan <strong>de</strong> meest courante belastingen voor <strong>buitenschrijnwerk</strong>.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

7


2. BASISBEGRIPPEN<br />

2.1. Definitie <strong>van</strong> <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Euroco<strong>de</strong> 0 maakt een on<strong>de</strong>rscheid tussen twee grenstoestan<strong>de</strong>n waaraan voldaan moet wor<strong>de</strong>n<br />

voor <strong>de</strong> berekening <strong>van</strong> elke constructie. In bei<strong>de</strong> gevallen (UGT of GGT, zie ver<strong>de</strong>r) moet<br />

overgegaan wor<strong>de</strong>n tot <strong>de</strong> berekening <strong>van</strong> Ed, <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>het</strong> effect <strong>van</strong> <strong>de</strong> belastingen<br />

(interne kracht, moment, …) <strong>op</strong> een constructie-element of <strong>op</strong> een volledige constructie. Wij<br />

willen er<strong>op</strong> wijzen dat <strong>de</strong>ze waar<strong>de</strong> berekend wordt aan <strong>de</strong> hand <strong>van</strong> een belastingscombinatie<br />

die afhankelijk is <strong>van</strong> <strong>de</strong> beschouw<strong>de</strong> grenstoestand.<br />

2.1.1. Uiterste grenstoestan<strong>de</strong>n (UGT)<br />

Deze betreffen <strong>de</strong> veiligheid <strong>van</strong> personen en/of <strong>de</strong> veiligheid <strong>van</strong> <strong>de</strong> constructie (instorting, …).<br />

Dit begrip komt doorgaans overeen met <strong>het</strong> maximale draagvermogen <strong>van</strong> een constructie of een<br />

constructie-element. De overmatige vervormingen, die kunnen lei<strong>de</strong>n tot structurele gebreken<br />

tengevolge <strong>van</strong> een mechanische instabiliteit, wor<strong>de</strong>n eveneens tot <strong>de</strong> uiterste grenstoestan<strong>de</strong>n<br />

gerekend (bv. knik).<br />

De UGT wor<strong>de</strong>n uitgedrukt met behulp <strong>van</strong> <strong>de</strong> volgen<strong>de</strong> vergelijking :<br />

waarbij<br />

Ed ≤ Rd<br />

Ed = <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>het</strong> effect <strong>van</strong> <strong>de</strong> belastingscombinaties die dienen om <strong>de</strong><br />

overeenkomstige grenstoestand te controleren<br />

Rd = <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> weerstand.<br />

2.1.2. Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

Deze betreffen <strong>de</strong> goe<strong>de</strong> werking <strong>van</strong> <strong>de</strong> constructie of <strong>de</strong> constructie-elementen, <strong>het</strong> comfort<br />

<strong>van</strong> <strong>de</strong> personen en <strong>het</strong> uitzicht <strong>van</strong> <strong>de</strong> constructie (scheurvorming, overmatige vervorming, …).<br />

De GGT wor<strong>de</strong>n uitgedrukt met behulp <strong>van</strong> <strong>de</strong> volgen<strong>de</strong> vergelijking :<br />

waarbij<br />

Ed ≤ Cd<br />

Cd = <strong>de</strong> nominale waar<strong>de</strong> of functie <strong>van</strong> <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> een bepaal<strong>de</strong> materiaaleigenschap,<br />

zoals <strong>de</strong> vervormingsgrenswaar<strong>de</strong><br />

Ed = zie hiervoor.<br />

2.2. Terminologie<br />

2.2.1. Belastingen<br />

Belastingen wor<strong>de</strong>n in <strong>de</strong> Euroco<strong>de</strong>s als volgt ge<strong>de</strong>finieerd :<br />

- geheel <strong>van</strong> krachten (lasten) die aangrijpen <strong>op</strong> <strong>de</strong> constructie (rechtstreekse belastingen)<br />

- geheel <strong>van</strong> <strong>op</strong>geleg<strong>de</strong> vervormingen of versnellingen die <strong>het</strong> resultaat kunnen zijn <strong>van</strong><br />

temperatuurschommelingen, wijzigingen <strong>van</strong> <strong>de</strong> vochtigheidsgraad, differentiële zettingen of<br />

aardbevingen (onrechtstreekse belastingen).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

8


Naargelang <strong>van</strong> haar variatie in <strong>de</strong> tijd kan een belasting blijvend (permanent), veran<strong>de</strong>rlijk<br />

(variabel) of toevallig (acci<strong>de</strong>nteel) zijn.<br />

2.2.1.1. Blijven<strong>de</strong> (permanente) belasting (G)<br />

Belasting die met grote waarschijnlijkheid zal aanhou<strong>de</strong>n geduren<strong>de</strong> <strong>de</strong> totale gegeven<br />

referentieduur en waar<strong>van</strong> <strong>de</strong> variatie in <strong>de</strong> tijd verwaarloosbaar is of waar<strong>van</strong> <strong>de</strong> variatie altijd<br />

in <strong>de</strong>zelf<strong>de</strong> zin (monotoon) plaatsvindt tot <strong>het</strong> bereiken <strong>van</strong> een grenswaar<strong>de</strong>.<br />

2.2.1.2. Veran<strong>de</strong>rlijke (variabele) belasting (Q)<br />

Belasting waar<strong>van</strong> <strong>de</strong> variatie in <strong>de</strong> tijd noch verwaarloosbaar noch monotoon is.<br />

2.2.1.3. Toevallige (acci<strong>de</strong>ntele) belasting (A)<br />

Belasting <strong>van</strong> bedui<strong>de</strong>n<strong>de</strong> om<strong>van</strong>g die gewoonlijk <strong>van</strong> korte duur is en die geduren<strong>de</strong> <strong>de</strong><br />

verho<strong>op</strong>te levensduur naar alle waarschijnlijkheid niet zal aangrijpen <strong>op</strong> <strong>de</strong> constructie.<br />

2.2.1.4. Rekenwaar<strong>de</strong> <strong>van</strong> een belasting of een belastingscombinatie (Fd(x))<br />

Waar<strong>de</strong> die verkregen wordt door <strong>de</strong> representatieve waar<strong>de</strong> te vermenigvuldigen met <strong>de</strong><br />

coëfficiënt of <strong>de</strong> partiële coëfficiënten voor één of meer<strong>de</strong>re belastingen.<br />

2.2.2. Partiële coëfficiënten<br />

− Partiële coëfficiënt voor <strong>de</strong> blijven<strong>de</strong> (permanente) belastingen :<br />

− γG : partiële coëfficiënt voor blijven<strong>de</strong> (permanente) belastingen die rekening houdt met<br />

onzekerhe<strong>de</strong>n <strong>op</strong> <strong>het</strong> rekenmo<strong>de</strong>l en met dimensionale schommelingen<br />

− γG,inf : partiële coëfficiënt voor blijven<strong>de</strong> (permanente) belastingen die rekening houdt met<br />

onzekerhe<strong>de</strong>n <strong>op</strong> <strong>het</strong> rekenmo<strong>de</strong>l en met dimensionale schommelingen, wanneer <strong>de</strong><br />

blijven<strong>de</strong> belasting een gunstig effect heeft<br />

− γG,sup : partiële coëfficiënt voor blijven<strong>de</strong> (permanente) belastingen die rekening houdt met<br />

onzekerhe<strong>de</strong>n <strong>op</strong> <strong>het</strong> rekenmo<strong>de</strong>l en met dimensionale schommelingen, wanneer <strong>de</strong><br />

blijven<strong>de</strong> belasting een ongunstig effect heeft.<br />

− Partiële coëfficiënt voor <strong>de</strong> veran<strong>de</strong>rlijke (variabele) belastingen γQ die rekening houdt met<br />

onzekerhe<strong>de</strong>n <strong>op</strong> <strong>het</strong> rekenmo<strong>de</strong>l en met dimensionale schommelingen.<br />

− Partiële coëfficiënt voor een materiaaleigenschap γM die rekening houdt met onzekerhe<strong>de</strong>n<br />

<strong>op</strong> <strong>het</strong> rekenmo<strong>de</strong>l en met dimensionale schommelingen.<br />

2.2.3. Combinatiecoëfficiënten<br />

− Coëfficiënt die <strong>de</strong> combinatiewaar<strong>de</strong> voor een begelei<strong>de</strong>n<strong>de</strong> veran<strong>de</strong>rlijke belasting ψ0<br />

<strong>de</strong>finieert : waar<strong>de</strong> die (voor zover dit <strong>op</strong> statistische basis mogelijk is) zodanig gekozen<br />

wordt dat <strong>de</strong> waarschijnlijkheid <strong>van</strong> <strong>het</strong> overschrij<strong>de</strong>n <strong>van</strong> <strong>de</strong> effecten die veroorzaakt wor<strong>de</strong>n<br />

door <strong>de</strong> combinatie ongeveer <strong>de</strong>zelf<strong>de</strong> is als voor <strong>de</strong> karakteristieke waar<strong>de</strong> <strong>van</strong> een<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

9


individuele belasting. Deze kan uitgedrukt wor<strong>de</strong>n als een welbepaal<strong>de</strong> fractie <strong>van</strong> <strong>de</strong><br />

karakteristieke waar<strong>de</strong> door toepassing <strong>van</strong> een coëfficiënt ψ0 ≤ 1.<br />

− Begelei<strong>de</strong>n<strong>de</strong> coëfficiënt voor <strong>de</strong> frequente belastingen ψ1 die <strong>de</strong> frequente waar<strong>de</strong> voor een<br />

veran<strong>de</strong>rlijke (variabele) belasting <strong>de</strong>finieert : waar<strong>de</strong> die (voor zover dit <strong>op</strong> statistische basis<br />

mogelijk is) zodanig gekozen wordt dat <strong>de</strong> totale tijdsduur (in <strong>de</strong> lo<strong>op</strong> <strong>van</strong> <strong>de</strong> gebruiksduur)<br />

geduren<strong>de</strong> welke <strong>de</strong>ze overschre<strong>de</strong>n wordt, slechts een kleine gegeven fractie uitmaakt <strong>van</strong> <strong>de</strong><br />

gebruiksduur, of waarbij <strong>de</strong> frequentie <strong>van</strong> overschrijding beperkt is tot een gegeven waar<strong>de</strong>.<br />

Deze kan uitgedrukt wor<strong>de</strong>n als een welbepaal<strong>de</strong> fractie <strong>van</strong> <strong>de</strong> karakteristieke waar<strong>de</strong> door<br />

toepassing <strong>van</strong> een coëfficiënt ψ1 ≤ 1.<br />

− Coëfficiënt die <strong>de</strong> quasi-blijven<strong>de</strong> waar<strong>de</strong> voor een veran<strong>de</strong>rlijke belasting ψ2 <strong>de</strong>finieert :<br />

waar<strong>de</strong> die zodanig bepaald wordt dat <strong>de</strong> totale tijdsduur geduren<strong>de</strong> welke <strong>de</strong>ze zal<br />

overschre<strong>de</strong>n wor<strong>de</strong>n, een aanzienlijke fractie <strong>van</strong> <strong>de</strong> referentieduur uitmaakt. Deze kan<br />

uitgedrukt wor<strong>de</strong>n als een welbepaal<strong>de</strong> fractie <strong>van</strong> <strong>de</strong> karakteristieke waar<strong>de</strong> door toepassing<br />

<strong>van</strong> een coëfficiënt ψ2 ≤ 1.<br />

2.2.4. De hoofdconstructie<br />

In een gebouw vormen <strong>de</strong> kolommen, balken en vloeren constructie-elementen die <strong>de</strong>el<br />

uitmaken <strong>van</strong> <strong>de</strong> hoofdconstructie. Deze elementen zijn ‘structureel’ omdat zij <strong>de</strong> secundaire<br />

constructies dragen en omdat <strong>het</strong> falen er<strong>van</strong> <strong>de</strong> globale stabiliteit <strong>van</strong> <strong>het</strong> gebouw in <strong>het</strong> gedrang<br />

kan brengen met alle economische en menselijke gevolgen <strong>van</strong>dien. Zij moeten met an<strong>de</strong>re<br />

woor<strong>de</strong>n betrouwbaar zijn en een aangepaste veiligheid bie<strong>de</strong>n, die groter is dan <strong>de</strong> veiligheid<br />

die geëist wordt voor <strong>de</strong> secundaire constructie-elementen of niet-structurele elementen.<br />

Dergelijke hoofdconstructies, bestemd voor resi<strong>de</strong>ntiële of kantoorgebouwen, vormen <strong>het</strong><br />

referentieka<strong>de</strong>r <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s. In <strong>het</strong> geval <strong>van</strong> schrijnwerk heeft men <strong>het</strong> over <strong>de</strong><br />

hoofdconstructie voor zover <strong>de</strong>ze <strong>het</strong> uitgangspunt vormt en <strong>de</strong> hierna bepaal<strong>de</strong> vermin<strong>de</strong>rings-<br />

of vermeer<strong>de</strong>ringscoëfficiënten <strong>van</strong> toepassing zijn.<br />

2.2.5. Secundaire constructies<br />

Gordijngevels, schrijnwerkgehelen en vensterramen vormen secundaire constructies omdat hun<br />

stabiliteit en weerstand enkel voor <strong>de</strong>ze elementen zelf <strong>van</strong> belang zijn. Een faling <strong>van</strong> <strong>de</strong>ze<br />

secundaire constructies heeft uitsluitend invloed <strong>op</strong> <strong>de</strong> vulelementen of <strong>de</strong> niet-structurele<br />

elementen die erdoor gedragen wor<strong>de</strong>n en heeft in geen geval gevolgen voor <strong>de</strong> hoofdconstructie<br />

<strong>van</strong> <strong>het</strong> gebouw. Secundaire constructies kunnen onafhankelijk <strong>van</strong> <strong>de</strong> hoofdconstructie<br />

ver<strong>van</strong>gen wor<strong>de</strong>n.<br />

Hoofdconstructie<br />

Vulpaneel en<br />

secundaire<br />

constructie<br />

Afbeelding 1 Voorbeeld <strong>van</strong> een secundaire constructie : glazen dak.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

10


2.2.6. Vulelementen<br />

Afbeelding 2 Voorbeeld <strong>van</strong> een secundaire constructie : gordijngevel.<br />

Het betreft elementen die in <strong>de</strong> constructie wor<strong>de</strong>n geplaatst om <strong>het</strong> gebouw af te sluiten en die<br />

geen rol spelen voor <strong>de</strong> stabiliteit <strong>van</strong> <strong>de</strong> hoofdconstructie. Zij moeten echter wel zodanig<br />

gedimensioneerd wor<strong>de</strong>n dat zij <strong>de</strong> belastingen aan <strong>de</strong> hoofdconstructie kunnen doorgeven via<br />

<strong>de</strong> secundaire constructie (indien aanwezig). Wanneer er geen tegengevel of steunmuur<br />

voorhan<strong>de</strong>n is, dienen <strong>de</strong>ze vulelementen tevens <strong>de</strong> veiligheid <strong>van</strong> personen te verzekeren (zie<br />

§ 2.2.8.).<br />

Nota 1 : indien een element meer<strong>de</strong>re functies tegelijkertijd vervult, moet men er<strong>van</strong> uitgaan dat<br />

<strong>het</strong> <strong>de</strong>el uitmaakt <strong>van</strong> <strong>de</strong> meest ongunstige functie. Wanneer <strong>het</strong> element bijvoorbeeld zowel<br />

behoort tot <strong>de</strong> secundaire constructie als tot <strong>de</strong> hoofdconstructie, dient men <strong>het</strong> te beschouwen als<br />

een hoofdconstructie.<br />

2.2.7. Gevolgklassen<br />

Vulpaneel en<br />

secundaire constructie<br />

Hoofdconstructie<br />

Dankzij <strong>de</strong> gevolgklassen kan er rekening gehou<strong>de</strong>n wor<strong>de</strong>n met <strong>het</strong> feit dat <strong>het</strong> falen <strong>van</strong><br />

secundaire constructies of vulelementen niet <strong>de</strong>zelf<strong>de</strong> economische en/of menselijke gevolgen<br />

heeft als <strong>het</strong> falen <strong>van</strong> <strong>de</strong> hoofdconstructie. De betrouwbaarheid kan met an<strong>de</strong>re woor<strong>de</strong>n<br />

aangepast wor<strong>de</strong>n. Via <strong>de</strong> coëfficiënt kFI is <strong>het</strong> mogelijk <strong>de</strong> betrouwbaarheid die <strong>van</strong> toepassing<br />

is <strong>op</strong> secundaire constructies en vulelementen aan te passen ten aanzien <strong>van</strong> <strong>de</strong>ze die <strong>van</strong><br />

toepassing is <strong>op</strong> <strong>de</strong> hoofdconstructie. Dit gebeurt in overeenstemming met <strong>de</strong> norm NBN<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

11


EN 1990. Deze coëfficiënt is <strong>op</strong>genomen in <strong>de</strong> partiële coëfficiënten voor <strong>de</strong> belastingen γQ en<br />

γG, tenzij <strong>de</strong> beschouw<strong>de</strong> belasting een gunstig effect heeft in een belastingscombinatie (zie nota<br />

NBN EN 1990:2002, bijlage b, § B3.3, tabel 3). De coëfficiënten γQ en γG wor<strong>de</strong>n ge<strong>de</strong>finieerd<br />

in § 2.2.2. De coëfficiënt voor <strong>de</strong> gevolgklasse is niet <strong>van</strong> toepassing <strong>op</strong> <strong>de</strong> partiële coëfficiënt<br />

voor een materiaaleigenschap.<br />

Nota 2 : in <strong>het</strong> vervolg <strong>van</strong> dit Rapport wer<strong>de</strong>n er partiële coëfficiënten toegekend aan <strong>de</strong><br />

verschillen<strong>de</strong> on<strong>de</strong>r<strong>de</strong>len en <strong>buitenschrijnwerk</strong>types. Zodoen<strong>de</strong> werd ge<strong>op</strong>teerd voor<br />

welbepaal<strong>de</strong> menselijke en economische gevolgen en werd er een betrouwbaarheidsniveau<br />

<strong>op</strong>gelegd aan <strong>de</strong> on<strong>de</strong>r<strong>de</strong>len en <strong>de</strong> courante schrijnwerktypes. Het is echter niet uitgesloten dat<br />

<strong>de</strong>ze laatste in <strong>het</strong> bouwwerk een bijzon<strong>de</strong>re plaats innemen, bijvoorbeeld omwille <strong>van</strong> hun<br />

afmetingen, <strong>de</strong> hoogte <strong>van</strong> <strong>het</strong> gebouw, hun functies of <strong>het</strong> exploitatietype <strong>van</strong> <strong>het</strong> bouwwerk<br />

waarin <strong>het</strong> schrijnwerk geplaatst wordt. In voorkomend geval zal <strong>het</strong> nodig zijn om <strong>de</strong> partiële<br />

coëfficiënten aan te passen aan <strong>de</strong> vereiste betrouwbaarheid. Voor gebouwen <strong>van</strong> meer dan<br />

50 meter hoog kan <strong>het</strong> nodig zijn om corrigeren<strong>de</strong> aanpassingen uit te voeren.<br />

2.2.8. De borstweringsfunctie in een gevel<br />

Borstweringen zijn voorzieningen ( 1 ) waarmee <strong>het</strong> mogelijk is <strong>de</strong> veiligheid <strong>van</strong> personen te<br />

verzekeren tegen risico’s die re<strong>de</strong>lijkerwijze voorzienbaar zijn<br />

− vallen in <strong>het</strong> ijle :<br />

o vallen door <strong>het</strong> venster (d.w.z. door <strong>het</strong> schrijnwerk)<br />

o struikelen over <strong>de</strong> vensterborstwering<br />

− verwondingen door contact :<br />

o snijwon<strong>de</strong>n door grote glasscherven<br />

o verwondingen/kneuzingen door toevallig contact met voornamelijk doorzichtige<br />

elementen ( 2 )<br />

als gevolg <strong>van</strong><br />

− inci<strong>de</strong>ntele schokken door één of meer<strong>de</strong>re menselijk(e) licha(a)m(en) tij<strong>de</strong>ns een<br />

voorval dat resulteert uit <strong>de</strong> menselijke activiteit waar<strong>van</strong> <strong>het</strong> risico re<strong>de</strong>lijkerwijze<br />

voorzienbaar is<br />

− <strong>het</strong> gedrum <strong>van</strong> een bewegen<strong>de</strong> mensenmassa, dat geen aanleiding geeft tot schokken,<br />

maar wel tot een druk <strong>op</strong> <strong>de</strong> bescherming.<br />

Schokken wor<strong>de</strong>n gelijkgesteld met dynamische belastingen. Het gedrum <strong>van</strong> een mensenmassa<br />

moet daarentegen beschouwd wor<strong>de</strong>n als een genormaliseer<strong>de</strong> statische belasting volgens <strong>de</strong><br />

norm NBN EN 1991-1-1 (§ 6.4). In dit geval gebeurt <strong>de</strong> controle on<strong>de</strong>r <strong>de</strong> vorm <strong>van</strong><br />

berekeningen en/of proeven (zie § 4.4).<br />

Dit concept moet beoor<strong>de</strong>eld wor<strong>de</strong>n uitgaan<strong>de</strong> <strong>van</strong> een ‘normaal’ of ‘normaal<br />

voorzienbaar’ gebruik <strong>van</strong> <strong>het</strong> bouwwerk. Dit sluit <strong>het</strong> bewust en weloverwogen nemen<br />

<strong>van</strong> risico’s door <strong>de</strong> gebruikers uit. Voor <strong>het</strong> gebruik wordt een re<strong>de</strong>lijk en verantwoord<br />

gedrag <strong>van</strong> <strong>de</strong> gebruikers veron<strong>de</strong>rsteld, of, indien <strong>het</strong> om kin<strong>de</strong>ren gaat, <strong>van</strong> <strong>de</strong> personen<br />

die met hun toezicht belast zijn.<br />

( 1 ) De voorziening kan bestaan uit <strong>het</strong> <strong>buitenschrijnwerk</strong> zelf en zijn vulelementen of uit een<strong>de</strong>r welke an<strong>de</strong>re<br />

voorziening (borstweringen, dwarsregels, …) die <strong>op</strong> <strong>het</strong> <strong>buitenschrijnwerk</strong> bevestigd werd.<br />

( 2 ) Wanneer <strong>de</strong> doorzichtige elementen uit glas bestaan, voorziet § 4.4.2.2.5 <strong>van</strong> <strong>de</strong> norm NBN S 23-002:2007 een<br />

aantal maatregelen om <strong>het</strong> risico <strong>op</strong> botsingen als gevolg <strong>van</strong> een gebrek aan zichtbaarheid te vermij<strong>de</strong>n. In dit<br />

Rapport gaan we hier echter niet dieper <strong>op</strong> in.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

12


3. BEPERKINGEN VAN DEZE SPECIFICATIES<br />

3.1. <strong>Toepassing</strong>sgebied<br />

Het voorliggen<strong>de</strong> Rapport is <strong>van</strong> toepassing <strong>op</strong> gevels, hellen<strong>de</strong> gevels, daken en veranda’s. De<br />

norm NBN EN 13830 heeft betrekking <strong>op</strong> gordijngevels met een helling <strong>van</strong> 0° tot 15° ten<br />

<strong>op</strong>zichte <strong>van</strong> <strong>de</strong> verticale. Hellen<strong>de</strong> gevels vertonen dan weer een helling gaan<strong>de</strong> <strong>van</strong> 15° tot 30°<br />

ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong> verticale. Daken, tenslotte, wor<strong>de</strong>n gekenmerkt door een helling <strong>van</strong> 5° tot<br />

60° ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong> horizontale.<br />

α<br />

Hellend<br />

30° 15° 15° 30°<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

α<br />

≤ 0,5 0,5 m. m<br />

≤ 0,5 m. m<br />

Afbeelding 3 Helling <strong>van</strong> daken en gevels.<br />

hellend<br />

Opmerking : om <strong>de</strong> afdichting niet in <strong>het</strong> gedrang te brengen, wordt steeds aanbevolen een<br />

helling > 10° ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong> horizontale aan te hou<strong>de</strong>n (tenzij een kleinere helling<br />

gerechtvaardigd is).<br />

3.2. Belastingen en combinaties<br />

De Euroco<strong>de</strong>s voorzien een controle in twee verschillen<strong>de</strong> grenstoestan<strong>de</strong>n (GGT en UGT),<br />

naargelang <strong>van</strong> <strong>de</strong> belastingen en belastingscombinaties die aangrijpen <strong>op</strong> <strong>het</strong> beschouw<strong>de</strong><br />

element. In dit Rapport komen <strong>de</strong> meest courante belastingen aan bod, met name :<br />

− <strong>het</strong> eigengewicht gk<br />

− <strong>de</strong> wind w<br />

− sneeuw s<br />

− <strong>de</strong> belastingen Ab indien <strong>het</strong> <strong>buitenschrijnwerk</strong> dienst doet als borstwering,<br />

alsook hun pertinente combinaties.<br />

Nota 3 : sneeuwbelastingen moeten enkel in aanmerking genomen wor<strong>de</strong>n voor<br />

<strong>buitenschrijnwerk</strong> waar<strong>van</strong> <strong>de</strong> helling kleiner is dan of gelijk is aan 60° ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong><br />

horizontale en dat niet uitgerust is met een sneeuwbarrière.<br />

Hellend<br />

Hellend<br />

α<br />

13


Wor<strong>de</strong>n niet in aanmerking genomen in dit Rapport :<br />

− <strong>de</strong> gebruiksbelastingen (<strong>op</strong>geleg<strong>de</strong> belastingen) : <strong>de</strong>ze moeten <strong>het</strong> voorwerp uitmaken <strong>van</strong><br />

een speciale studie (door berekening volgens <strong>de</strong> gel<strong>de</strong>n<strong>de</strong> normen, Euroco<strong>de</strong>s of an<strong>de</strong>re<br />

documenten), of moeten proefon<strong>de</strong>rvin<strong>de</strong>lijk gecontroleerd wor<strong>de</strong>n. Deze belastingen kunnen<br />

tij<strong>de</strong>lijk of blijvend zijn :<br />

− tij<strong>de</strong>lijk : bv. gon<strong>de</strong>ls, lad<strong>de</strong>rs voor <strong>het</strong> on<strong>de</strong>rhoud, …<br />

− blijvend : bv. vaan<strong>de</strong>lhou<strong>de</strong>rs, aan <strong>de</strong> gordijngevel bevestig<strong>de</strong> gaan<strong>de</strong>rijen, …<br />

− <strong>de</strong> toevallige (acci<strong>de</strong>ntele) belastingen (bv. te wijten aan <strong>de</strong> impact <strong>van</strong> een voertuig, aan<br />

gasexplosies, …) : in voorkomend geval moeten <strong>de</strong>ze in rekening gebracht wor<strong>de</strong>n<br />

overeenkomstig <strong>de</strong> toepassingsregels uit <strong>de</strong> norm EN 1991-1-7 inzake acci<strong>de</strong>ntele belastingen<br />

en hun combinaties.<br />

Belangrijk : zie nota 21.<br />

3.3. Controle in <strong>de</strong> grenstoestan<strong>de</strong>n <strong>van</strong><br />

<strong>buitenschrijnwerk</strong>elementen<br />

Bouwkundige hypothesen<br />

De in aanmerking te nemen overspanning <strong>van</strong> <strong>de</strong> weerstandsprofielen wordt gemeten <strong>op</strong> <strong>de</strong><br />

neutrale lijn <strong>van</strong> <strong>de</strong> weerstandsprofielen en tussen <strong>de</strong> steunpunten ( 3 ).<br />

Voor vulelementen die niet uit glas bestaan, mag hun eigen stijfheid in aanmerking genomen<br />

wor<strong>de</strong>n, voor zover dit toegelaten wordt door <strong>de</strong> fabrikant en <strong>het</strong> mechanische gedrag<br />

voldoen<strong>de</strong> gekend is.<br />

Voor gekleurd schrijnwerk, in <strong>het</strong> bijzon<strong>de</strong>r wanneer <strong>de</strong> kleur gekarakteriseerd wordt door een<br />

sterke energieabsorptie en/of wanneer <strong>het</strong> schrijnwerk langs binnen en langs buiten een<br />

verschillen<strong>de</strong> kleurabsorptie vertoont, kan <strong>het</strong> noodzakelijk blijken om <strong>de</strong> vervorming on<strong>de</strong>r<br />

temperatuurgradiënt (buiging <strong>van</strong> <strong>de</strong> profielen als gevolg <strong>van</strong> <strong>het</strong> temperatuurverschil tussen<br />

<strong>het</strong> binnen- en <strong>het</strong> buiten<strong>op</strong>pervlak; ook ‘bimetaaleffect’ genoemd) na te gaan. Bij <strong>de</strong>ze<br />

controle dient men rekening te hou<strong>de</strong>n met :<br />

• <strong>de</strong> kleur <strong>van</strong> <strong>het</strong> profiel (d.w.z. met <strong>de</strong> energieabsorptiecoëfficiënt <strong>van</strong> <strong>het</strong> <strong>op</strong>pervlak)<br />

• <strong>de</strong> thermische uitzettingscoëfficiënt <strong>van</strong> <strong>het</strong> materiaal waaruit <strong>het</strong> profiel <strong>op</strong>gebouwd is<br />

• <strong>de</strong> vrije lengte (tussen <strong>de</strong> verankeringen <strong>van</strong> <strong>het</strong> constructie-element) <strong>van</strong> <strong>het</strong> profiel<br />

• <strong>de</strong> verwachte temperaturen aan <strong>het</strong> binnen- en buiten<strong>op</strong>pervlak. In bepaal<strong>de</strong> gevallen zal<br />

<strong>de</strong>ze belasting door <strong>de</strong> temperatuur gecombineerd moeten wor<strong>de</strong>n met an<strong>de</strong>re belastingen<br />

(zie NBN EN 1991-1-5). Deze controle, die hier niet ver<strong>de</strong>r besproken wordt, is te<br />

beschouwen als een aanvulling <strong>op</strong> <strong>de</strong> controle die in <strong>de</strong>ze specificaties wordt vereist.<br />

De controle (door berekening of proeven) <strong>van</strong> <strong>de</strong> verbindingen tussen <strong>de</strong> stijlen en <strong>de</strong><br />

dwarsregels (GGT on<strong>de</strong>r rotatie en doorbuiging <strong>van</strong> <strong>de</strong> dwarsregel) is aanbevolen <strong>van</strong> zodra<br />

<strong>de</strong> som <strong>van</strong> <strong>de</strong> belastingen in één richting <strong>op</strong> een dwarsregel meer dan 800 N bedraagt.<br />

Wanneer er twijfel bestaat omtrent <strong>het</strong> draagvermogen of <strong>de</strong> gebruikte verbindingstechniek,<br />

kan <strong>het</strong> nodig blijken een controle uit te voeren voor kleinere belastingen.<br />

( 3 ) Tenzij een an<strong>de</strong>re han<strong>de</strong>lswijze gerechtvaardigd is aan <strong>de</strong> hand <strong>van</strong> proeven en/of precieze berekeningen (met <strong>de</strong><br />

eindige-elementenmetho<strong>de</strong>).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

14


3.4. Controle <strong>van</strong> <strong>de</strong> grenstoestan<strong>de</strong>n<br />

3.4.1. Schrijnwerk en grenstoestan<strong>de</strong>n<br />

3.4.1.1. Het geval <strong>van</strong> vensters en dakvensters<br />

De weerstandsprofielen <strong>van</strong> vensters wor<strong>de</strong>n normaalgesproken enkel berekend in <strong>de</strong><br />

gebruiksgrenstoestand (GGT).<br />

Wanneer <strong>het</strong> <strong>buitenschrijnwerk</strong> een <strong>op</strong>pervlakte <strong>van</strong> meer dan 10 m 2 heeft, moeten <strong>de</strong><br />

weerstandsprofielen <strong>van</strong> <strong>de</strong> schrijnwerkgehelen of <strong>van</strong> <strong>de</strong> samengestel<strong>de</strong> vensters (in <strong>het</strong><br />

bijzon<strong>de</strong>r <strong>de</strong> stijlen, <strong>de</strong> dwarsregels en <strong>de</strong> verbindingsprofielen), waar<strong>van</strong> <strong>de</strong> vrije afstand tussen<br />

<strong>de</strong> steunpunten meer dan 2,20 m bedraagt, voor <strong>de</strong> berekening als lichte constructies beschouwd<br />

wor<strong>de</strong>n (zie § 3.4.1.2).<br />

3.4.1.2. Het geval <strong>van</strong> lichte constructies : gordijngevels en glazen daken<br />

Deze constructies wor<strong>de</strong>n berekend in <strong>de</strong> gebruiksgrenstoestand (GGT) en in <strong>de</strong> uiterste<br />

grenstoestand (UGT). De criteria voor <strong>de</strong> gebruiksgrenstoestand zijn vermeld in <strong>de</strong> tabellen <strong>van</strong><br />

§ 4.6.<br />

3.4.1.3. Het geval <strong>van</strong> vulelementen<br />

De in aanmerking te nemen belastingen en <strong>de</strong> criteria zijn ge<strong>de</strong>finieerd in § 4.6. Doorgaans zal<br />

<strong>het</strong> noodzakelijk zijn <strong>de</strong> product- of materiaalspecificaties te raadplegen.<br />

3.4.1.4. Het geval <strong>van</strong> verandaconstructies<br />

Men kan verschillen<strong>de</strong> soorten veranda’s on<strong>de</strong>rschei<strong>de</strong>n naargelang <strong>van</strong> hun verbinding met <strong>de</strong><br />

gebouwstructuur en hun vloer<strong>op</strong>pervlakte.<br />

Nota 4 : in <strong>de</strong> volgen<strong>de</strong> afbeeldingen staat « lg » voor « <strong>de</strong> lengte <strong>van</strong> een aan <strong>de</strong> wind<br />

blootgestel<strong>de</strong> zij<strong>de</strong> ».<br />

3.4.1.4.1. Autonome constructies<br />

In dit geval moet <strong>de</strong> veranda al dan niet beschouwd wor<strong>de</strong>n als een uitbreiding <strong>van</strong> <strong>het</strong> gebouw,<br />

waarbij er geen enkele stabiliseren<strong>de</strong> verbinding met dit gebouw bestaat. De verandaconstructie<br />

is dus autonoom wat <strong>de</strong> stabiliteit betreft.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

15


lg<br />

Afbeelding 4 Veranda – Autonome constructie.<br />

3.4.1.4.2. Constructies die door één zij<strong>de</strong> <strong>van</strong> <strong>het</strong> gebouw gestabiliseerd wor<strong>de</strong>n<br />

In dit geval moet <strong>de</strong> verandaconstructie beschouwd wor<strong>de</strong>n als een uitbreiding <strong>van</strong> <strong>het</strong> bestaan<strong>de</strong><br />

gebouw en wordt <strong>de</strong>ze aan één zij<strong>de</strong> gestabiliseerd door <strong>de</strong> gebouwstructuur.<br />

lg<br />

Afbeelding 5 Constructie die door één zij<strong>de</strong> <strong>van</strong> <strong>het</strong> gebouw gestabiliseerd wordt.<br />

3.4.1.4.3. Constructies die door minstens twee zij<strong>de</strong>n <strong>van</strong> <strong>het</strong> gebouw gestabiliseerd<br />

wor<strong>de</strong>n<br />

In dit geval moet <strong>de</strong> verandaconstructie beschouwd wor<strong>de</strong>n als een uitbreiding <strong>van</strong> <strong>het</strong> bestaan<strong>de</strong><br />

gebouw en wordt <strong>de</strong>ze door twee of meer zij<strong>de</strong>n gestabiliseerd door <strong>de</strong> gebouwstructuur.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

lg<br />

lg<br />

16


lg<br />

lg<br />

Afbeelding 6 Constructies die door minstens twee zij<strong>de</strong>n <strong>van</strong> <strong>het</strong> gebouw gestabiliseerd wor<strong>de</strong>n.<br />

3.4.1.4.4. Verandacategorieën voor <strong>de</strong> structurele berekening<br />

Men kan verschillen<strong>de</strong> soorten veranda’s on<strong>de</strong>rschei<strong>de</strong>n naargelang <strong>van</strong> hun verbinding met <strong>de</strong><br />

gebouwstructuur en hun vloer<strong>op</strong>pervlakte. Zodoen<strong>de</strong> kan men er, afhankelijk <strong>van</strong> <strong>de</strong><br />

<strong>ontwerp</strong>voorwaar<strong>de</strong>n, een geschikte betrouwbaarheid aan toekennen door <strong>de</strong> keuze <strong>van</strong> een<br />

gepast rekenmo<strong>de</strong>l en a<strong>de</strong>quate coëfficiënten.<br />

Tabel 1 Verandacategoriën.<br />

Vloer<strong>op</strong>pervlakte Vloer<strong>op</strong>pervlakte<br />

Verandacategoriën<br />

Vloer<strong>op</strong>pervlakte<br />

≤ 9 m²<br />

9 < S ≤ 30 m²<br />

Gevels ≥ 1 gevel<br />

tegen <strong>de</strong> tegen <strong>de</strong><br />

wind wind<br />

> 30 m²<br />

Gevels ≥ 1 gevel<br />

tegen <strong>de</strong> tegen <strong>de</strong><br />

wind wind<br />

(lg ≤ 4 m) (lg > 4 m) (lg. ≤ 4 m) (lg > 4 m)<br />

Autonome constructies 2 2 3 – 3<br />

Gestabiliseerd door één zij<strong>de</strong> 1 1 2 – 3<br />

Gestabiliseerd door twee of<br />

meer aangrenzen<strong>de</strong> zij<strong>de</strong>n<br />

Gestabiliseerd door twee<br />

1 1 2 2 3<br />

tegenover elkaar liggen<strong>de</strong><br />

zij<strong>de</strong>n<br />

1 2 3 3 3<br />

3.4.1.4.4.1. Categorie 1<br />

De verandaconstructies <strong>van</strong> categorie 1 wor<strong>de</strong>n berekend als secundaire vensterconstructies.<br />

De gevel en <strong>het</strong> dak <strong>van</strong> <strong>de</strong> veranda wor<strong>de</strong>n bijgevolg uitsluitend berekend in <strong>de</strong><br />

gebruiksgrenstoestand, volgens <strong>de</strong> belastingsvoorschriften en <strong>de</strong> criteria voor secundaire<br />

vensterconstructies uit § 4.6.<br />

3.4.1.4.4.2. Categorie 2<br />

De verandaconstructies <strong>van</strong> categorie 2 wor<strong>de</strong>n berekend als secundaire<br />

gordijngevelconstructies. De gevel en <strong>het</strong> dak <strong>van</strong> <strong>de</strong> veranda wor<strong>de</strong>n bijgevolg zowel<br />

berekend in <strong>de</strong> gebruiksgrenstoestand als in <strong>de</strong> uiterste grenstoestand, volgens <strong>de</strong><br />

belastingsvoorschriften en <strong>de</strong> criteria voor secundaire gordijngevelconstructies uit § 4.6.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

lg<br />

17


3.4.1.4.4.3. Categorie 3<br />

De verandaconstructies <strong>van</strong> categorie 3 wor<strong>de</strong>n berekend als hoofdconstructies. De gevel en<br />

<strong>het</strong> dak <strong>van</strong> <strong>de</strong> veranda wor<strong>de</strong>n bijgevolg zowel berekend in <strong>de</strong> gebruiksgrenstoestand als in <strong>de</strong><br />

uiterste grenstoestand volgens <strong>de</strong> belastingsvoorschriften uit <strong>de</strong> Euroco<strong>de</strong>s. In <strong>de</strong><br />

gebruiksgrenstoestand dient men <strong>op</strong> <strong>de</strong> stijlen, <strong>de</strong> dwarsregels en <strong>de</strong> kepers <strong>van</strong> <strong>de</strong><br />

hoofdconstructie <strong>de</strong> vervormingscriteria voor secundaire constructies uit § 4.6 toe te passen.<br />

3.4.1.4.4.4. Aanvullen<strong>de</strong> voorschriften<br />

− De bevestiging <strong>van</strong> <strong>de</strong> verandaconstructie moet geschie<strong>de</strong>n <strong>op</strong> <strong>de</strong> bestaan<strong>de</strong> gebouwstructuur<br />

(niet <strong>op</strong> <strong>de</strong> parementen).<br />

− In <strong>het</strong> geval <strong>van</strong> veranda’s met <strong>op</strong>engaan<strong>de</strong> <strong>de</strong>len zoals schuifvensters in <strong>de</strong> verticale wan<strong>de</strong>n,<br />

moeten <strong>de</strong> vervormingscriteria voor <strong>de</strong> randbalken of <strong>de</strong> dakgoten zodanig aangepast wor<strong>de</strong>n<br />

dat hun goe<strong>de</strong> werking in <strong>de</strong> voor <strong>de</strong> gebruiksgrenstoestand voorgeschreven<br />

windvoorwaar<strong>de</strong>n gewaarborgd blijft. In bepaal<strong>de</strong> gevallen moeten <strong>de</strong> kolommen <strong>van</strong> <strong>de</strong><br />

veranda gecontroleerd wor<strong>de</strong>n tegen knikken (kritieke belasting <strong>van</strong> Euler).<br />

− Wanneer <strong>de</strong> veranda verwij<strong>de</strong>rbare wan<strong>de</strong>n, <strong>de</strong>uren of <strong>op</strong>engaan<strong>de</strong> vleugels heeft, wordt<br />

aangera<strong>de</strong>n om <strong>de</strong> situatie waarbij alles ge<strong>op</strong>end is te beschouwen als een toevallige<br />

(acci<strong>de</strong>ntele) combinatie. Dit Rapport gaat niet dieper in <strong>op</strong> <strong>de</strong>ze controle.<br />

− Om functionele gebreken <strong>van</strong> <strong>de</strong> volledige veranda te voorkomen, wordt aanbevolen om :<br />

− <strong>de</strong> horizontale pijl bovenaan <strong>de</strong> kolommen in <strong>de</strong> gebruiksgrenstoestand te beperken tot<br />

h/300 of 10 mm<br />

− <strong>de</strong> horizontale verplaatsingen <strong>van</strong> <strong>de</strong> structurele kn<strong>op</strong>en <strong>van</strong> <strong>de</strong> veranda te beperken tot<br />

10 mm in <strong>de</strong> gebruiksgrenstoestand.<br />

3.4.2. Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

De hierna vermel<strong>de</strong> criteria voor <strong>de</strong> grenstoestand zijn <strong>van</strong> toepassing in <strong>de</strong> grote meer<strong>de</strong>rheid<br />

<strong>van</strong> <strong>de</strong> gevallen. Voor een aantal specifieke schrijnwerkelementen kan <strong>het</strong> echter nodig zijn<br />

strengere criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n toe te passen, bijvoorbeeld om met <strong>de</strong> volgen<strong>de</strong><br />

situaties rekening te hou<strong>de</strong>n :<br />

voor <strong>de</strong> structurele dwarsregels of stijlen die <strong>de</strong> vulelementen (beglazingen, panelen, ka<strong>de</strong>rs)<br />

dragen, dient men <strong>de</strong> toelaatbare doorbuiging zodanig te beperken :<br />

− dat <strong>de</strong> bediening <strong>van</strong> <strong>de</strong> <strong>op</strong>engaan<strong>de</strong> <strong>de</strong>len niet wordt verhin<strong>de</strong>rd<br />

− dat <strong>de</strong> vulelementen waar<strong>op</strong> <strong>de</strong> eventuele dwarsregels steunen, niet beschadigd raken. In<br />

dit geval moeten <strong>de</strong> vulelementen zodanig ontworpen wor<strong>de</strong>n dat zij <strong>de</strong> belastingen <strong>op</strong> een<br />

veilige en duurzame manier kunnen <strong>op</strong>nemen.<br />

<strong>de</strong> structurele dwarsregels of stijlen die <strong>de</strong> <strong>op</strong>engaan<strong>de</strong> vleugels (beglazingen, panelen,<br />

ka<strong>de</strong>rs) dragen, moeten een zodanige stijfheid vertonen dat <strong>de</strong> normale bediening <strong>van</strong> <strong>de</strong><br />

<strong>op</strong>engaan<strong>de</strong> vleugels geen ongewenste dynamische effecten (trillingen, overmatige<br />

vervormingen) met zich meebrengt.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

18


4. BELASTINGEN<br />

4.1. Windbelasting<br />

4.1.1. Gebruiksduur en terugkeerperio<strong>de</strong> <strong>van</strong> <strong>de</strong> wind (cprob)<br />

Hoofdconstructies, secundaire constructies en vulelementen hebben niet alleen een an<strong>de</strong>re<br />

levensduur, maar ook een verschillend ver<strong>van</strong>gingsgemak.<br />

Wat <strong>de</strong> hoofdconstructies, <strong>de</strong> verankeringen en <strong>de</strong> secundaire constructies betreft, werd een<br />

terugkeerperio<strong>de</strong> <strong>van</strong> 50 jaar (cprob² = 1) als referentie genomen. Voor niet-structurele elementen<br />

werd <strong>de</strong> terugkeerperio<strong>de</strong> als volgt aangepast :<br />

0,<br />

5<br />

⎛1<br />

− 0,<br />

2×<br />

ln( −ln(<br />

1−<br />

1/<br />

n))<br />

⎞<br />

c prob = ⎜<br />

⎟ waarbij n <strong>het</strong> aantal jaren voorstelt.<br />

⎝ 1−<br />

0,<br />

2 × ln( − ln( 0,<br />

98))<br />

⎠<br />

4.1.2. Uitdrukking <strong>van</strong> <strong>de</strong> winddruk<br />

De winddruk w is <strong>het</strong> resultaat <strong>van</strong> <strong>het</strong> drukverschil tussen <strong>de</strong> buitenomgeving we (<strong>de</strong>ze waar<strong>de</strong><br />

krijgt <strong>de</strong> in<strong>de</strong>x e) en <strong>de</strong> binnenomgeving wi (<strong>de</strong>ze waar<strong>de</strong> krijgt <strong>de</strong> in<strong>de</strong>x i) :<br />

w = we - wi<br />

w = ce(ze)qref 50jaar . cprob² . cpe - ce(zi)qref 50jaar. cprob² . cpi<br />

waarbij cp = cpe - cpi<br />

ce(zi)qref 50jaar = ce(ze)qref 50jaar (<strong>de</strong>ze laatste hypothese vereenvoudigt <strong>de</strong> berekening <strong>van</strong> w<br />

zon<strong>de</strong>r <strong>de</strong> veiligheid in gevaar te brengen; zij verhoogt dus <strong>de</strong> waar<strong>de</strong> <strong>van</strong> w).<br />

De vereenvoudig<strong>de</strong> uitdrukking <strong>van</strong> <strong>de</strong> winddruk w is bijgevolg :<br />

w = ce(z)qref 50jaar . cprob² . cp<br />

waarbij – w : waar<strong>de</strong> <strong>van</strong> <strong>de</strong> nettowinddruk<br />

– cprob : coëfficiënt voor <strong>de</strong> terugkeerperio<strong>de</strong> <strong>van</strong> <strong>de</strong> wind (gelijk aan 1 voor 50 jaar)<br />

– cp : coëfficiënt die rekening houdt met alle plaatselijke drukcoëfficiënten<br />

– qref 50jaar : gemid<strong>de</strong>l<strong>de</strong> dynamische referentiedruk voor een terugkeerperio<strong>de</strong> <strong>van</strong> <strong>de</strong><br />

wind <strong>van</strong> 50 jaar<br />

– ce(z) : blootstellingscoëfficiënt die <strong>de</strong> ruwheid <strong>van</strong> <strong>het</strong> terrein en <strong>de</strong> hoogte boven<br />

<strong>de</strong> grond in aanmerking neemt. Deze coëfficiënt wordt ge<strong>de</strong>finieerd in artikel 4.5<br />

<strong>van</strong> <strong>de</strong> norm EN 1991-1-4 en zet <strong>de</strong> gemid<strong>de</strong>l<strong>de</strong> druk ook om in een piekdruk,<br />

rekening hou<strong>de</strong>nd met <strong>de</strong> turbulentiefactor kl.<br />

Nota 5 : voor een beschrijving <strong>van</strong> <strong>de</strong> verschillen<strong>de</strong> coëfficiënten : NBN EN 1991-1-4.<br />

Nota 6 : bij <strong>de</strong> berekening <strong>van</strong> <strong>de</strong> winddruk wordt rekening gehou<strong>de</strong>n met <strong>de</strong><br />

orografiecoëfficiënt c o , <strong>de</strong> ruwheidscoëfficiënt c r , <strong>de</strong> coëfficiënt c season (in geval <strong>van</strong> tij<strong>de</strong>lijke<br />

constructies), <strong>de</strong> richtingscoëfficiënt c DIR en <strong>de</strong> dynamische coëfficiënt c d . Deze coëfficiënten zijn<br />

ge<strong>de</strong>finieerd in <strong>de</strong> norm EN 1991-1-4. In <strong>de</strong> huidige specificaties wordt er<strong>van</strong> uitgegaan dat<br />

c DIR = c r = c d = c season = c o = 1. De turbulentiefactor k l is gelijk aan 1 voor <strong>de</strong><br />

ruwheidscategorieën 0, I en II, gelijk aan 0,95 voor <strong>de</strong> ruwheidscategorie III en gelijk aan 0,85<br />

voor <strong>de</strong> ruwheidscategorie IV. Indien <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n coëfficiënten voor<strong>op</strong>stellen die<br />

verschillen <strong>van</strong> 1, dient men <strong>de</strong>ze zorgvuldig te bepalen en in aanmerking te nemen bij <strong>de</strong><br />

berekening <strong>van</strong> <strong>de</strong> winddruk w.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

19


4.1.2.1. Bepaling <strong>van</strong> <strong>de</strong> referentiehoogte voor <strong>de</strong> wind<br />

Nota 7 : <strong>de</strong> geografische hoogte <strong>van</strong> <strong>het</strong> terrein waar<strong>op</strong> <strong>de</strong> on<strong>de</strong>rzochte constructie zich<br />

bevindt, moet niet in aanmerking genomen wor<strong>de</strong>n.<br />

4.1.2.1.1. Inleiding<br />

De referentiehoogte ze voor <strong>de</strong> wind is <strong>het</strong> niveauverschil tussen <strong>het</strong> lage referentieniveau (z = 0)<br />

en <strong>het</strong> hoge referentieniveau (z) dat als volgt ge<strong>de</strong>finieerd wordt :<br />

z = z − h<br />

In <strong>de</strong> volgen<strong>de</strong> paragrafen wordt verdui<strong>de</strong>lijkt hoe men ze dient te bepalen.<br />

4.1.2.1.2. Laag referentieniveau z = 0 voor <strong>de</strong> bepaling <strong>van</strong> ze<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

e<br />

Het referentieniveau (z = 0) is <strong>het</strong> niveau <strong>van</strong>waar <strong>de</strong> hoogte ze (zie § 4.1.2.1.3) wordt gemeten.<br />

In <strong>de</strong> grote meer<strong>de</strong>rheid <strong>van</strong> <strong>de</strong> gevallen wordt <strong>het</strong> referentieniveau z = 0 genomen aan <strong>de</strong> voet<br />

<strong>van</strong> <strong>het</strong> gebouw. Er bestaan echter bijzon<strong>de</strong>re <strong>ontwerp</strong>voorwaar<strong>de</strong>n waarbij <strong>het</strong> niveau z = 0<br />

verplaatst wordt met een hoogte hdis, gemeten ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong> voet <strong>van</strong> <strong>het</strong> gebouw, zodat <strong>de</strong><br />

waar<strong>de</strong> ze toeneemt (hdis(-)) of daalt (hdis(+)).<br />

In <strong>de</strong> norm NBN EN 1991-1-4 en zijn nationaal toepassingsdocument (NAD) wordt <strong>het</strong> niveau<br />

z = 0 ge<strong>de</strong>finieerd naargelang <strong>van</strong> <strong>de</strong> volgen<strong>de</strong> gevallen :<br />

• vlak terrein (afbeelding 7)<br />

• terrein met een niveauverschil (afbeelding 8)<br />

• kuststreek : <strong>de</strong> getij<strong>de</strong>n wor<strong>de</strong>n in aanmerking genomen in <strong>de</strong> ruwheidscategorieën 0 en I<br />

(afbeelding 9)<br />

• ste<strong>de</strong>n : nabijheid <strong>van</strong> gebouwen in <strong>de</strong> ruwheidscategorie IV (afbeelding 10).<br />

Geval <strong>van</strong> een vlak terrein<br />

Wind<br />

z=0<br />

Geval <strong>van</strong> een hellend terrein<br />

h hdis dis dis<br />

Wind<br />

z=0<br />

Wind<br />

dis<br />

Wind<br />

z=0<br />

Wind<br />

Afbeelding 7 Referentieniveau z = 0 <strong>op</strong> een vlak terrein.<br />

Wind<br />

Wind<br />

z=0<br />

z=0<br />

Wind<br />

z=0<br />

Wind<br />

h dis<br />

z=0<br />

z=0<br />

Wind<br />

Afbeelding 8 Referentieniveau z = 0 <strong>op</strong> een terrein met een niveauverschil.<br />

h dis<br />

20


In aanmerking nemen <strong>van</strong> <strong>de</strong> getij<strong>de</strong>n in <strong>de</strong> ruwheidscategorieën 0 en I<br />

h dis<br />

Laagtij<br />

z=0<br />

Hoogtij<br />

Wind<br />

Afbeelding 9 Referentieniveau z = 0 in <strong>de</strong> kuststreek.<br />

Nabijheid <strong>van</strong> gebouwen in <strong>de</strong> ruwheidscategorie IV<br />

Wind<br />

Indien <strong>het</strong> gebouw zich <strong>op</strong> een terrein <strong>van</strong> categorie IV bevindt, zorgen <strong>de</strong> nabijgelegen<br />

gebouwen en <strong>de</strong> an<strong>de</strong>re obstakels ervoor dat <strong>de</strong> wind zich gedraagt alsof <strong>het</strong> grondniveau<br />

verhoogd werd tot <strong>op</strong> een hoogte hdis (aangeduid als <strong>de</strong> verplaatsingshoogte). De hoogte hdis kan<br />

bepaald wor<strong>de</strong>n door <strong>de</strong> uitdrukking :<br />

z=0<br />

x ≤ 2 have hdis is <strong>de</strong> kleinste waar<strong>de</strong> <strong>van</strong> 0,8 have of 0,6 h<br />

2 have < x < 6 have hdis is <strong>de</strong> kleinste waar<strong>de</strong> <strong>van</strong> (1,2 have - 0,2 x) of 0,6 h<br />

x ≥ 6 have hdis = 0<br />

Afbeelding 10 Referentieniveau z = 0 in een stad.<br />

In <strong>de</strong> norm NBN EN 1991-1-4 wordt <strong>de</strong> afstand have ge<strong>de</strong>finieerd als <strong>de</strong> obstructiehoogte.<br />

Volgens <strong>de</strong> Nationale Bijlage (ANB) <strong>van</strong> <strong>de</strong> NBN EN 1991-1-4 is have <strong>de</strong> gemid<strong>de</strong>l<strong>de</strong> hoogte<br />

<strong>van</strong> <strong>de</strong> constructies die 15 % innemen <strong>van</strong> <strong>het</strong> <strong>op</strong>pervlak waar<strong>op</strong> <strong>de</strong> constructies <strong>de</strong> grootste<br />

hoogte hebben in <strong>de</strong> hoeksector <strong>van</strong> <strong>het</strong> beschouw<strong>de</strong> terrein <strong>van</strong> categorie IV. Bij gebrek aan<br />

an<strong>de</strong>rslui<strong>de</strong>n<strong>de</strong> informatie mag men er<strong>van</strong> uitgaan dat have voor <strong>de</strong> terreinruwheidscategorie IV<br />

gelijk is aan 15 m.<br />

Vermits <strong>de</strong>ze regels afhankelijk zijn <strong>van</strong> <strong>de</strong> oriëntatie, moeten <strong>de</strong> waar<strong>de</strong>n <strong>van</strong> have en x<br />

vastgelegd wor<strong>de</strong>n voor elke sector <strong>van</strong> 30°, zoals beschreven in § 4.1.2.3.3.<br />

Het profiel <strong>van</strong> <strong>de</strong> dynamische piekdruk in functie <strong>van</strong> <strong>de</strong> hoogte kan naar boven wor<strong>de</strong>n<br />

verplaatst met een hoogte hdis.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

21


4.1.2.1.3. Hoog referentieniveau z voor <strong>de</strong> bepaling <strong>van</strong> ze<br />

4.1.2.1.3.1. Wan<strong>de</strong>n on<strong>de</strong>r <strong>de</strong> wind (on<strong>de</strong>rdruk)<br />

Wat <strong>de</strong> ver<strong>de</strong>ling <strong>van</strong> <strong>de</strong> dynamische druk over <strong>de</strong> gevel on<strong>de</strong>r <strong>de</strong> wind en over <strong>de</strong> zijgevels<br />

(zones A, B, C en E, zie afbeelding 21) betreft, is <strong>de</strong> aanbevolen referentiehoogte ze <strong>het</strong><br />

niveauverschil tussen <strong>de</strong> gebouwhoogte h en z = 0.<br />

4.1.2.1.3.2. Wan<strong>de</strong>n tegen <strong>de</strong> wind (overdruk)<br />

De waar<strong>de</strong> ze kan beschouwd wor<strong>de</strong>n als <strong>de</strong> referentiehoogte voor <strong>de</strong> externe windbelasting <strong>op</strong><br />

gevels. Ze wordt hierna gegeven voor <strong>het</strong> geval <strong>van</strong> daken. In § 4.1.2.5.2.1 wordt ze beschreven,<br />

rekening hou<strong>de</strong>nd met <strong>het</strong> aantal dakschil<strong>de</strong>n.<br />

De referentiehoogte ze voor <strong>de</strong> wan<strong>de</strong>n in overdruk <strong>van</strong> gebouwen met een rechthoekig<br />

grondplan (zone D, zie afbeelding 21) is afhankelijk <strong>van</strong> <strong>de</strong> vormfactor h/b en stemt altijd<br />

overeen met <strong>de</strong> grootste hoogte <strong>van</strong> <strong>de</strong> verschillen<strong>de</strong> wand<strong>de</strong>len. Deze hoogte wordt aangegeven<br />

in afbeelding 11 voor <strong>de</strong> drie volgen<strong>de</strong> gevallen :<br />

geval 1 : h ≤ b. ze is dan <strong>het</strong> niveauverschil tussen h en <strong>het</strong> lage referentieniveau z = 0; een<br />

gebouw waar<strong>van</strong> <strong>de</strong> hoogte h kleiner is dan b, mag als één element beschouwd wor<strong>de</strong>n<br />

geval 2 : b ≤ h < 2b :<br />

− on<strong>de</strong>raan : ze is <strong>het</strong> niveauverschil tussen b en z = 0<br />

− bovenaan : ze is <strong>het</strong> niveauverschil tussen h en <strong>het</strong> lage referentieniveau z = 0<br />

Een gebouw waar<strong>van</strong> <strong>de</strong> hoogte h groter is dan b, maar kleiner is dan 2b mag beschouwd<br />

wor<strong>de</strong>n als twee elementen, waarbij <strong>het</strong> on<strong>de</strong>rste <strong>de</strong>el gemeten wordt <strong>van</strong>af z = 0 over een<br />

hoogte gelijk aan b en <strong>het</strong> bovenste <strong>de</strong>el <strong>de</strong> rest inneemt<br />

geval 3 : h > 2b :<br />

− on<strong>de</strong>raan : ze is <strong>het</strong> niveauverschil tussen b en z = 0<br />

− bovenaan : ze is <strong>het</strong> niveauverschil tussen h en <strong>het</strong> lage niveauverschil z = 0<br />

− <strong>het</strong> tussenliggen<strong>de</strong> ge<strong>de</strong>elte : ze = zstrip<br />

Van een gebouw waar<strong>van</strong> <strong>de</strong> hoogte h groter is dan 2b, mag men veron<strong>de</strong>rstellen dat <strong>het</strong> uit<br />

meer<strong>de</strong>re elementen bestaat, waarbij <strong>het</strong> on<strong>de</strong>rste <strong>de</strong>el gemeten wordt <strong>van</strong>af z = 0 over een<br />

hoogte gelijk aan b, waarbij <strong>het</strong> bovenste <strong>de</strong>el gemeten wordt <strong>van</strong>af <strong>de</strong> t<strong>op</strong> <strong>van</strong> <strong>het</strong> gebouw<br />

over een hoogte gelijk aan b, en waarbij <strong>het</strong> tussenliggen<strong>de</strong> ge<strong>de</strong>elte inge<strong>de</strong>eld kan wor<strong>de</strong>n in<br />

horizontale stroken met een hoogte hstrip zoals aangegeven in afbeelding 11 (<strong>de</strong> bepaling <strong>van</strong><br />

<strong>het</strong> aantal stroken wordt aan <strong>de</strong> <strong>ontwerp</strong>er overgelaten).<br />

In afbeelding 11 werd z = 0 voor <strong>het</strong> geval 1 bij wijze <strong>van</strong> voorbeeld on<strong>de</strong>r <strong>het</strong> niveau <strong>van</strong> <strong>de</strong><br />

voet <strong>van</strong> <strong>het</strong> gebouw geplaatst. Voor <strong>het</strong> geval 2 werd z = 0 boven <strong>het</strong> niveau <strong>van</strong> <strong>de</strong> voet <strong>van</strong><br />

<strong>het</strong> gebouw geplaatst, terwijl z = 0 voor <strong>het</strong> geval 3 <strong>op</strong> <strong>het</strong> niveau <strong>van</strong> <strong>de</strong> voet <strong>van</strong> <strong>het</strong> gebouw<br />

geplaatst werd. De positionering <strong>van</strong> z = 0 is onafhankelijk <strong>van</strong> <strong>de</strong> verschillen<strong>de</strong> situaties, maar<br />

moet wel gebeuren in overeenstemming met § 4.1.2.1.2.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

22


Afbeelding 11 Referentiehoogte ze rekening hou<strong>de</strong>nd met h, b, z = 0, en overeenkomstig<br />

dynamisch drukprofiel.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

23


4.1.2.1.3.3. Nabijheid <strong>van</strong> gebouwen met zeer grote hoogte<br />

Wanneer een gebouw meer dan twee keer groter is dan <strong>de</strong> gemid<strong>de</strong>l<strong>de</strong> hoogte have <strong>van</strong> <strong>de</strong><br />

nabijgelegen constructies, mag voor <strong>de</strong> berekening <strong>van</strong> een<strong>de</strong>r welke <strong>van</strong> <strong>de</strong>ze nabijgelegen<br />

constructies in een eerste bena<strong>de</strong>ring uitgegaan wor<strong>de</strong>n <strong>van</strong> <strong>de</strong> dynamische piekdruk <strong>op</strong> <strong>de</strong><br />

hoogte zn (ze = zn) boven <strong>het</strong> maaiveld :<br />

• indien x ≤ r, dan is zn = 0,5 . r<br />

•<br />

⎡ ⎛ 2.<br />

hlow<br />

⎞ ⎤<br />

indien r < x < 2 r, dan is zn<br />

= 0 , 5.<br />

⎢r<br />

− ⎜1−<br />

⎟.<br />

( x − r)<br />

⎥⎦<br />

⎣ ⎝ r ⎠<br />

• indien x ≥ 2 r, dan is zn = hlow<br />

waarbij <strong>de</strong> straal r als volgt ge<strong>de</strong>fineerd kan wor<strong>de</strong>n :<br />

• r = hhigh, indien hhigh ≤ 2 dlarge<br />

• r = 2dlarge, indien hhigh > 2 dlarge.<br />

De hoogte <strong>van</strong> <strong>de</strong> constructie hlow, <strong>de</strong> straal r, <strong>de</strong> afstand x en <strong>de</strong> afmetingen dsmall en dlarge zijn<br />

voorgesteld in afbeelding 12. De toename <strong>van</strong> <strong>de</strong> windsnelhe<strong>de</strong>n mag wor<strong>de</strong>n genegeerd<br />

wanneer hlow groter is dan <strong>de</strong> helft <strong>van</strong> <strong>de</strong> hoogte hhigh <strong>van</strong> <strong>het</strong> hoge gebouw, met name zn = hlow.<br />

hhigh<br />

dsmall<br />

hlow,1<br />

2<br />

1<br />

dlarge<br />

dlarge<br />

Afbeelding 12 Invloed <strong>van</strong> een hoog gebouw <strong>op</strong> twee verschillen<strong>de</strong> nabijgelegen constructies (1<br />

en 2).<br />

Naargelang <strong>van</strong> <strong>de</strong> windrichting wor<strong>de</strong>n alle gebouwen uit afbeelding 12 on<strong>de</strong>rworpen aan een<br />

overdruk en een on<strong>de</strong>rdruk.<br />

Afbeelding 13 illustreert <strong>de</strong> invloed <strong>van</strong> een hoog gebouw <strong>op</strong> <strong>de</strong> nabijgelegen lage gebouwen.<br />

Daarnaast wordt ook <strong>de</strong> hoogte zn aangegeven.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

h ave<br />

2<br />

x2<br />

1<br />

r<br />

x1<br />

r<br />

dsmall<br />

24


h high<br />

h high<br />

h low<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

rr<br />

r<br />

z zn=0,5r-h n=0,5r-h n=0,5r-h dis<br />

rr<br />

r<br />

z zn=0,5r-h n=0,5r-h n=0,5r-h dis<br />

h low<br />

z n


als gevolg <strong>van</strong> <strong>de</strong> <strong>op</strong>pervlakteruwheid zich niet meer doen gevoelen en <strong>van</strong>af waar <strong>de</strong><br />

windsnelheid logaritmisch toeneemt.<br />

Tabel 2 Terreinruwheidscategorieën.<br />

0<br />

I<br />

II<br />

III<br />

IV<br />

Terreinruwheidscategorieën<br />

Zee of kuststreek die<br />

blootstaat aan zeewin<strong>de</strong>n<br />

Meer of zone met uiterst<br />

weinig vegetatie die vrij is<br />

<strong>van</strong> obstakels<br />

Zone met lage vegetatie<br />

(zoals gras), met of zon<strong>de</strong>r<br />

alleenstaan<strong>de</strong> obstakels<br />

(bomen, gebouwen) <strong>op</strong> een<br />

on<strong>de</strong>rlinge afstand <strong>van</strong><br />

minstens 20 keer hun<br />

hoogte<br />

Zone met een regelmatige<br />

begroeiing, met<br />

alleenstaan<strong>de</strong> gebouwen of<br />

obstakels <strong>op</strong> een on<strong>de</strong>rlinge<br />

afstand <strong>van</strong> maximum 20<br />

keer hun hoogte (bv.<br />

dorpen, voorste<strong>de</strong>n,<br />

permanente bossen)<br />

Ste<strong>de</strong>lijke zones waar<br />

minstens 15 % <strong>van</strong> <strong>het</strong><br />

<strong>op</strong>pervlak wordt ingenomen<br />

door gebouwen met een<br />

gemid<strong>de</strong>l<strong>de</strong> hoogte <strong>van</strong><br />

meer dan 15 m<br />

zmin<br />

(m)<br />

4.1.2.3. Hoeksector en terreinruwheidscategorieën<br />

Voorbeel<strong>de</strong>n<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

1<br />

1<br />

2<br />

5<br />

10<br />

De Nationale Belgische Bijlage <strong>van</strong> <strong>de</strong> NBN EN 1991-1-4 <strong>de</strong>finieert <strong>de</strong> procedure ter bepaling<br />

<strong>van</strong> <strong>de</strong> ruwheidscategorie.<br />

26


4.1.2.3.1. Windrichting<br />

Voor een gegeven wand wordt <strong>de</strong> windrichting in aanmerking genomen die loodrecht invalt <strong>op</strong><br />

<strong>de</strong>ze wand. Voor een hoek <strong>van</strong> een gebouw dient men <strong>de</strong> bissectrice <strong>van</strong> <strong>de</strong> door <strong>de</strong> wan<strong>de</strong>n<br />

gevorm<strong>de</strong> hoek als <strong>de</strong> windrichting te beschouwen.<br />

4.1.2.3.2. Nominale hoeksector<br />

De nominale hoeksector wordt ge<strong>de</strong>finieerd als een sector met straal x die een hoek <strong>van</strong> ± 45°<br />

vormt ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong> beschouw<strong>de</strong> windrichting (afbeelding 14).<br />

4.1.2.3.3. Hoeksector <strong>van</strong> 30°<br />

De hoeksector <strong>van</strong> 30° wordt ge<strong>de</strong>finieerd als een sector met straal x die een hoek <strong>van</strong> ± 15°<br />

vormt ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong> bissectrice.<br />

XXX<br />

45° 45°<br />

Wind Vent<br />

15° 15°<br />

15° 15°<br />

α°<br />

4.1.2.3.4. Straal <strong>van</strong> <strong>de</strong> hoeksector<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

XX<br />

Afbeelding 14 Hoeksectoren.<br />

45° 45°<br />

15° 15° 15° 15° 15° 15°<br />

Wind<br />

De straal x drukt <strong>de</strong> maximale afstand <strong>van</strong> <strong>de</strong> constructie uit tot waar <strong>de</strong> ruwheid bestu<strong>de</strong>erd<br />

moet wor<strong>de</strong>n. Deze waar<strong>de</strong> wordt gegeven in <strong>de</strong> volgen<strong>de</strong> vergelijking, naargelang <strong>van</strong> <strong>de</strong><br />

referentiehoogte voor <strong>de</strong> windbelasting ze = z – hdis (zie § 4.1.2.3.1), waarbij z = <strong>de</strong> hoogte <strong>van</strong><br />

<strong>het</strong> gebouw :<br />

x = 23 . ze 1,2 , waarbij x > 300 m.<br />

Vent<br />

Nota 8 : in <strong>de</strong> praktijk kan <strong>het</strong> voor <strong>de</strong> verschillen<strong>de</strong> gevels <strong>van</strong> een gebouw nodig zijn om<br />

diverse ruwheidscategorieën te beschouwen, afhankelijk <strong>van</strong> <strong>de</strong> windrichting.<br />

27


Straal <strong>van</strong> <strong>de</strong> hoeksector x<br />

Afbeelding 15 Straal <strong>van</strong> <strong>de</strong> hoeksector x.<br />

4.1.2.3.5. Procedure voor <strong>de</strong> bepaling <strong>van</strong> <strong>de</strong> ruwheidscategorie<br />

Hierna volgt een beschrijving <strong>van</strong> <strong>de</strong> te volgen procedure :<br />

1. De waar<strong>de</strong> ze wordt bepaald, rekening hou<strong>de</strong>nd met <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n. Vervolgens stelt<br />

men <strong>de</strong> meest ongunstige ruwheidscategorie vast (0, I, II, III, IV), d.w.z. <strong>de</strong> categorie met <strong>het</strong><br />

kleinste Romeinse cijfer, die zich in <strong>de</strong> beschouw<strong>de</strong> nominale hoeksector met straal x<br />

bevindt (x wordt berekend aan <strong>de</strong> hand <strong>van</strong> § 4.1.2.3.4).<br />

2. De hoeksector <strong>van</strong> 30° wordt zodanig geplaatst dat <strong>de</strong> ingesloten <strong>op</strong>pervlakte, gekenmerkt<br />

door <strong>de</strong> meest ongunstige ruwheidscategorie, zo groot mogelijk is.<br />

3. Tenslotte dient men na te gaan of <strong>de</strong> <strong>op</strong>pervlakte met <strong>de</strong> meest ongunstige ruwheidscategorie<br />

minstens 10 % <strong>van</strong> <strong>de</strong> totale <strong>op</strong>pervlakte <strong>van</strong> <strong>de</strong> hoeksector <strong>van</strong> 30° vertegenwoordigt :<br />

− zo ja, dient men <strong>de</strong>ze meest ongunstige ruwheidscategorie toe te passen<br />

− zo neen, dient men <strong>de</strong>ze ruwheidscategorie te negeren, <strong>de</strong> resteren<strong>de</strong> ruwheidscategorieën<br />

te beschouwen en <strong>de</strong> procedure te hernemen bij punt 3.<br />

Nota 9 : <strong>het</strong> is niet <strong>de</strong> som <strong>van</strong> <strong>de</strong> <strong>op</strong>pervlaktes < 10 % <strong>van</strong> eenzelf<strong>de</strong> ruwheidscategorie die in<br />

aanmerking genomen wordt. Elk <strong>op</strong>pervlak <strong>van</strong> een welbepaal<strong>de</strong> ruwheidscategorie wordt met<br />

an<strong>de</strong>re woor<strong>de</strong>n individueel beschouwd.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

28


II<br />

III<br />

I<br />

X<br />

45° 45° 45° 45°<br />

45° 45° 45° 45°<br />

15° 15° 15° 15°<br />

15° 15° 15° 15°<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

15° 15° 15° 15° 15° 15°<br />

IV<br />

NOORD<br />

ZUID<br />

Afbeelding 16 Voorbeeld.<br />

We beschouwen een gebouw met een hoogte <strong>van</strong> 50 m, hdis = 0; x = 2750 m<br />

Oplossing :<br />

• wind <strong>op</strong> <strong>de</strong> zuidgevel : ruwheidscategorie I<br />

• wind <strong>op</strong> <strong>de</strong> noordgevel : ruwheidscategorie II<br />

4.1.2.4. Bepaling <strong>van</strong> <strong>de</strong> coëfficiënt ce(z) . qref 50jaar<br />

Tabel 3 geeft een overzicht <strong>van</strong> <strong>de</strong> waar<strong>de</strong>n voor <strong>de</strong> druk, in functie <strong>van</strong> <strong>de</strong> ruwheidscategorieën<br />

en <strong>de</strong> hoogten ze.<br />

29


Tabel 3 Waar<strong>de</strong> voor <strong>de</strong> coëfficiënt ce(z ) . qref 50jaar.<br />

ce(z) . qref 50jaar<br />

Hoogte<br />

Terreincategorieën<br />

ze (m) 0 I II III IV<br />

100 1866 1818 1693 1419 1128<br />

95 1851 1802 1675 1400 1110<br />

90 1836 1785 1657 1381 1091<br />

85 1819 1768 1638 1361 1071<br />

80 1802 1749 1618 1340 1050<br />

75 1784 1730 1597 1317 1028<br />

70 1765 1709 1574 1293 1005<br />

65 1744 1687 1550 1268 980<br />

60 1722 1663 1524 1241 954<br />

55 1698 1637 1496 1212 926<br />

50 1672 1609 1465 1180 895<br />

45 1644 1578 1432 1145 862<br />

40 1612 1544 1395 1107 825<br />

35 1576 1506 1354 1064 784<br />

30 1536 1463 1307 1016 738<br />

28 1518 1444 1286 995 718<br />

26 1499 1423 1264 972 696<br />

24 1478 1401 1240 948 673<br />

22 1456 1377 1215 921 648<br />

20 1431 1351 1187 893 622<br />

18 1405 1323 1157 862 593<br />

16 1376 1291 1123 828 561<br />

14 1343 1256 1086 790 526<br />

12 1305 1216 1043 748 486<br />

10 1261 1170 994 698 441<br />

9 1236 1143 966 670 441<br />

8 1208 1114 935 639 441<br />

7 1177 1081 900 605 441<br />

6 1142 1043 861 566 441<br />

5 1100 1000 815 522 441<br />

2 903 793 601 522 441<br />

1 765 651 601 522 441<br />

Nota 10 : <strong>de</strong> coëfficiënt c e (z) q ref 50 jaar wordt bepaald volgens <strong>de</strong> norm NBN EN 1991-1-4 (2005)<br />

voor een terugkeerperio<strong>de</strong> <strong>van</strong> 50 jaar bij een referentiewindsnelheid v b,0 = 26 m/s.<br />

Nota 11 : <strong>de</strong> waar<strong>de</strong> <strong>van</strong> z e (m) wordt gemeten <strong>van</strong>af <strong>de</strong> referentie z = 0 (zie § 4.1.2.1.2).<br />

Wanneer een meer precieze waar<strong>de</strong> nodig is (bv. tengevolge <strong>van</strong> <strong>de</strong> specifieke inplanting <strong>van</strong><br />

een bouwwerk), kan <strong>de</strong> waar<strong>de</strong> <strong>van</strong> v b,0 afgeleid wor<strong>de</strong>n uit afbeelding 4.3 of tabel 4.2 <strong>van</strong> <strong>de</strong><br />

Nationale Bijlage ANB <strong>van</strong> <strong>de</strong> NBN EN 1991-1-4 of uit bijlage 1 <strong>van</strong> voorliggend Rapport.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

30


4.1.2.5. Bepaling <strong>van</strong> <strong>de</strong> drukcoëfficiënt cp<br />

4.1.2.5.1. Definitie <strong>van</strong> cp<br />

De drukcoëfficiënt cp is gelijk aan <strong>het</strong> verschil tussen <strong>de</strong> buitendrukcoëfficiënt en <strong>de</strong><br />

binnendrukcoëfficiënt : cp = cpe - cpi. Gewoonlijk wordt een overdruk voorgesteld door een<br />

plusteken (+) en een on<strong>de</strong>rdruk door een minteken (-). Men on<strong>de</strong>rscheidt twee gevallen :<br />

• <strong>de</strong> buitenzij<strong>de</strong> <strong>van</strong> <strong>de</strong> bestu<strong>de</strong>er<strong>de</strong> wand ligt aan <strong>de</strong> lijzij<strong>de</strong> en staat bloot aan een overdruk<br />

(muur “a” in afbeelding 17) :<br />

cp(+) = cpe(+) - cp(-)<br />

waarbij<br />

− cpe(+) : <strong>de</strong> buitendrukcoëfficiënt (overdruk) <strong>van</strong> <strong>de</strong> beschouw<strong>de</strong> zone (zie § 4.1.2.5.2.1)<br />

− cpi(-) : <strong>de</strong> binnendrukcoëfficiënt (on<strong>de</strong>rdruk) (zie § 4.1.2.5.3)<br />

• <strong>de</strong> buitenzij<strong>de</strong> <strong>van</strong> <strong>de</strong> bestu<strong>de</strong>er<strong>de</strong> wand ligt on<strong>de</strong>r <strong>de</strong> wind of evenwijdig met <strong>de</strong> wind (<strong>de</strong><br />

muren “b”, “c” en “d” in afbeelding 17) en staat dus bloot aan een on<strong>de</strong>rdruk :<br />

cp(-) = cpe(-) - cpi(+)<br />

waarbij<br />

− cpe(-) : <strong>de</strong> buitendrukcoëfficiënt (on<strong>de</strong>rdruk) <strong>van</strong> <strong>de</strong> beschouw<strong>de</strong> zone (zie § 4.1.2.5.2.1)<br />

− cpi(+) : <strong>de</strong> binnendrukcoëfficiënt (overdruk) (zie § 4.1.2.5.3).<br />

Wind (+)<br />

Verticale doorsne<strong>de</strong> Horizontale doorsne<strong>de</strong><br />

(+)<br />

(-)<br />

a b<br />

Afbeelding 17 Windbelasting <strong>op</strong> een gebouw : on<strong>de</strong>rdrukken en overdrukken.<br />

De buitendrukcoëfficiënt cpe+ is constant over <strong>de</strong> volledige wand, vermits <strong>de</strong> windbelasting<br />

gelijkmatig uitgeoefend wordt. De plaatselijke drukcoëfficiënt cpe-, die overeenstemt met een<br />

wand in on<strong>de</strong>rdruk, wordt daarentegen beïnvloed door <strong>de</strong> turbulenties en wervelwin<strong>de</strong>n aan <strong>de</strong><br />

hoeken, <strong>de</strong> ran<strong>de</strong>n, <strong>de</strong> nok, …, die <strong>de</strong> plaatselijke drukwaar<strong>de</strong> doen stijgen. Deze coëfficiënt zal<br />

dus een verschillen<strong>de</strong> waar<strong>de</strong> hebben naargelang <strong>van</strong> <strong>de</strong> beschouw<strong>de</strong> zone (centraal ge<strong>de</strong>elte,<br />

puntgevelrand, rand, hoek, …).<br />

De binnendrukcoëfficiënt cpi+ of cpi- is afhankelijk <strong>van</strong> <strong>de</strong> permeabiliteit <strong>van</strong> <strong>het</strong> gebouw en <strong>van</strong><br />

zijn binnenin<strong>de</strong>ling.<br />

De waar<strong>de</strong>n <strong>van</strong> cpe (en dus ook <strong>van</strong> cp) zullen hoger zijn naarmate <strong>het</strong> belaste <strong>op</strong>pervlak kleiner<br />

is.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

(-)<br />

Wind (+)<br />

a<br />

c<br />

(+)<br />

d<br />

(-)<br />

(-)<br />

31<br />

b<br />

(-)


4.1.2.5.2. Waar<strong>de</strong>n voor <strong>de</strong> buitendrukcoëfficiënt cpe<br />

In dit Rapport komen enkel gevels en daken met één of twee dakschil<strong>de</strong>n aan bod. Voor an<strong>de</strong>re<br />

configuraties verwijzen wij naar <strong>de</strong> norm NBN EN 1991-1-4 en diens Nationale Bijlage.<br />

De buitendrukcoëfficiënten cpe die <strong>van</strong> toepassing zijn <strong>op</strong> gebouwen en gebouw<strong>de</strong>len zijn<br />

afhankelijk <strong>van</strong> <strong>de</strong> afmeting <strong>van</strong> <strong>het</strong> belastings<strong>op</strong>pervlak A, d.w.z. <strong>de</strong> <strong>op</strong>pervlakte <strong>van</strong> <strong>het</strong><br />

gebouw die blootstaat aan <strong>de</strong> belasting die inwerkt <strong>op</strong> <strong>het</strong> te berekenen element.<br />

In afbeelding 18 wor<strong>de</strong>n voorbeel<strong>de</strong>n gegeven <strong>van</strong> belastings<strong>op</strong>pervlakken A voor<br />

verankeringen en vulpanelen.<br />

Afbeelding 18 Voorbeel<strong>de</strong>n <strong>van</strong> belastings<strong>op</strong>pervlakken A.<br />

In <strong>de</strong> tabellen voor <strong>de</strong> verschillen<strong>de</strong> gebouwconfiguraties zijn <strong>de</strong> buitendrukcoëfficiënten<br />

<strong>op</strong>gegeven voor een belastings<strong>op</strong>pervlak A <strong>van</strong> 1 m² en 10 m². De plaatselijke coëfficiënten<br />

wor<strong>de</strong>n aangeduid als cpe,1, <strong>de</strong> globale coëfficiënten als cpe,10.<br />

Nota 12 : <strong>de</strong> waar<strong>de</strong>n <strong>van</strong> c zijn bestemd voor <strong>de</strong> berekening <strong>van</strong> kleine elementen met een<br />

pe,1<br />

<strong>op</strong>pervlakte <strong>van</strong> min<strong>de</strong>r dan of gelijk aan 1 m 2<br />

(zoals gevel- en dakelementen) en hun<br />

bevestigingen. De waar<strong>de</strong>n <strong>van</strong> c zijn <strong>de</strong> drukcoëfficiënten voor belastings<strong>op</strong>pervlakken <strong>van</strong><br />

pe,10<br />

10 m² en kunnen tevens gebruikt wor<strong>de</strong>n voor belastings<strong>op</strong>pervlakken <strong>van</strong> meer dan 10 m² (bv.<br />

voor <strong>de</strong> berekening <strong>van</strong> <strong>de</strong> draagstructuur <strong>van</strong> een gebouw).<br />

Nota 13 : in dit Rapport wor<strong>de</strong>n platte daken (d.w.z. daken waar<strong>van</strong> <strong>de</strong> dakhelling begrepen is<br />

tussen -5°< θ < 5°) buiten beschouwing gelaten.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

32


Nota 14 : wanneer <strong>het</strong> belastings<strong>op</strong>pervlak A over meer<strong>de</strong>re zones verspreid is (afzon<strong>de</strong>rlijk<br />

genomen windrichtingen of integratie <strong>van</strong> <strong>de</strong> vier windrichtingen), moeten <strong>de</strong> coëfficiënten voor<br />

<strong>de</strong> meest ongunstige zone in aanmerking genomen wor<strong>de</strong>n. Wanneer een zone echter meer dan<br />

2/3 <strong>van</strong> <strong>het</strong> belastings<strong>op</strong>pervlak A vertegenwoordigt, kan <strong>de</strong>ze beschouwd wor<strong>de</strong>n als<br />

dominant. In dit geval zijn <strong>de</strong> coëfficiënten voor <strong>de</strong> betreffen<strong>de</strong> zone <strong>van</strong> toepassing <strong>op</strong> <strong>het</strong><br />

volledige belastings<strong>op</strong>pervlak A.<br />

De waar<strong>de</strong>n<br />

• cpe,1, die gel<strong>de</strong>n voor belastings<strong>op</strong>pervlakken, kleiner dan 1 m²,<br />

• cpe,10, die gel<strong>de</strong>n voor belastings<strong>op</strong>pervlakken, gelijk aan of groter dan 10 m²,<br />

vormen <strong>de</strong> logaritmische interpolatiegrenzen voor belastings<strong>op</strong>pervlakken <strong>van</strong> 1 < A < 10 m²<br />

volgens <strong>de</strong> formule cpe,A = cpe,1 - (cpe,1 - cpe,10) log10 A (zie afbeelding 19).<br />

Afbeelding 19 Aanbevolen procedure voor <strong>de</strong> bepaling <strong>van</strong> <strong>de</strong> buitendrukcoëfficiënt cpe in <strong>het</strong><br />

geval <strong>van</strong> gebouwen met een belastings<strong>op</strong>pervlak A tussen 1 m² en 10 m².<br />

Bepaling <strong>van</strong> <strong>de</strong> waar<strong>de</strong>n cpe,1 (1 m²) en cpe,10 (10 m²)<br />

Bij elk <strong>ontwerp</strong> dient men <strong>de</strong> vier conventionele windrichtingen in aanmerking te nemen. In <strong>het</strong><br />

geval <strong>van</strong> gevel- of dakelementen, kunnen <strong>de</strong>ze vier richtingen geïntegreerd wor<strong>de</strong>n en is <strong>het</strong><br />

mogelijk <strong>de</strong> meest ongunstige situatie te bepalen. Deze re<strong>de</strong>nering mag echter niet wor<strong>de</strong>n<br />

veralgemeend zon<strong>de</strong>r <strong>de</strong> voorafgaan<strong>de</strong> beschouwing <strong>van</strong> <strong>de</strong> hoofdconstructies.<br />

De vier conventionele windrichtingen zijn voorgesteld in afbeelding 20.<br />

Wind θ = 90° (*)<br />

Wind θ = 0°<br />

Wind θ = 90°<br />

Wind θ = 180°<br />

Afbeelding 20 Vier conventionele windrichtingen.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

33


Geval <strong>van</strong> verticale gevels – Bepaling <strong>van</strong> <strong>de</strong> zones A, B, C, D, E<br />

− Afzon<strong>de</strong>rlijk genomen windrichtingen<br />

Men beschikt enkel over <strong>de</strong> cpe-waar<strong>de</strong>n die overeenkomen met een windrichting loodrecht <strong>op</strong><br />

<strong>de</strong> zij<strong>de</strong>n <strong>van</strong> <strong>het</strong> gebouw.<br />

In afbeelding 21 wor<strong>de</strong>n <strong>de</strong> gevelzones voor een welbepaal<strong>de</strong> windrichting weergegeven door<br />

een hoofdletter en een in<strong>de</strong>x. De zone D vertegenwoordigt <strong>de</strong> zone tegen <strong>de</strong> wind, <strong>de</strong> zones A, B<br />

en C vertegenwoordigen <strong>de</strong> randzones, terwijl <strong>de</strong> zone E <strong>de</strong> zone on<strong>de</strong>r <strong>de</strong> wind voorstelt. In <strong>het</strong><br />

geval <strong>van</strong> een gebouw met een hellend dak stemt <strong>het</strong> referentieniveau ze voor <strong>de</strong> winddruk<br />

overeen met <strong>het</strong> niveauverschil tussen z = 0 en <strong>de</strong> hoogte h, die ge<strong>de</strong>finieerd wordt als volgt :<br />

- gevel : h is <strong>de</strong> hoogte tot aan <strong>de</strong> dakrand (dakgoot)<br />

- puntgevel : h is <strong>de</strong> hoogte tot aan <strong>de</strong> nok.<br />

Planzicht<br />

Wind θ = 0°<br />

D<br />

1- Geval e < d<br />

2- Geval e ≥ d<br />

3- Geval e ≥ 5d<br />

Opstan<strong>de</strong>n<br />

1- Geval e < d<br />

Wind θ = 0°<br />

A<br />

A<br />

e/5<br />

A<br />

e<br />

d<br />

B<br />

B<br />

A<br />

B<br />

C<br />

d-e<br />

C<br />

Afbeelding 21 Gevelzones voor een welbepaal<strong>de</strong> windrichting.<br />

− Waar<strong>de</strong> <strong>van</strong> cpe,1 (1 m²) en cpe,10 (10 m²) afhankelijk <strong>van</strong> <strong>de</strong> gebouwzones A, B, C, D en E<br />

In tabel 4 zijn <strong>de</strong> waar<strong>de</strong>n <strong>van</strong> cpe,1 (1 m²) en cpe,10 (10 m²) <strong>op</strong>gegeven. Voor tussenliggen h/dwaar<strong>de</strong>n<br />

dient men een lineaire interpolatie toe te passen.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

E<br />

h<br />

b<br />

2 - Geval e ≥ d<br />

Wind θ = 0°<br />

3 - Geval e ≥ 5d<br />

h<br />

Wind θ = 0°<br />

e = minimum<br />

<strong>van</strong> b of 2h<br />

e/5<br />

A<br />

d<br />

d<br />

A<br />

B<br />

h<br />

h<br />

h<br />

h<br />

34


Tabel 4 Aanbevolen waar<strong>de</strong>n voor <strong>de</strong> buitendrukcoëfficiënten voor verticale muren <strong>van</strong><br />

gebouwen met een rechthoekig grondplan.<br />

Zones A B C D E<br />

h/d cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1<br />

5 -1,2 -1,4 -0,8 -1,1 -0,5 +0,8 +1,0 -0,7<br />

1 -1,2 -1,4 -0,8 -1,1 -0,5 +0,8 +1,0 -0,5<br />

≤ 0,25 -1,2 -1,4 -0,8 -1,1 -0,5 +0,7 +1,0 -0,3<br />

− Integratie <strong>van</strong> <strong>de</strong> vier windrichtingen<br />

In afbeelding 22 zijn <strong>de</strong> verschillen<strong>de</strong> windrichtingen <strong>op</strong> één enkele gevel voorgesteld; <strong>de</strong> zone<br />

en <strong>de</strong> oriëntatie <strong>van</strong> <strong>de</strong> wind wor<strong>de</strong>n weergegeven door een hoofdletter en een in<strong>de</strong>x.<br />

Geval 2 waarbij ei ≥ di<br />

Geval 2 waarbij e i d i<br />

h<br />

bb bb b0° 0° 0° 0° 0° / / / / / d d d d d 90° 90° 90° 90° 90°<br />

Wind Wind Wind θ θ θ = = = 0° 0° 0°<br />

Geval 1 waarbij e i


Door <strong>de</strong> integratie <strong>van</strong> <strong>de</strong> windrichtingen is <strong>het</strong> mogelijk <strong>de</strong> meest ongunstige cpe-coëfficiënten<br />

te <strong>de</strong>finiëren, naargelang <strong>van</strong> <strong>de</strong> positie <strong>van</strong> <strong>de</strong> beschouw<strong>de</strong> gevel<strong>op</strong>pervlakken. De verklaring<br />

<strong>van</strong> <strong>de</strong> gevolg<strong>de</strong> re<strong>de</strong>nering is <strong>op</strong>genomen in bijlage 2.<br />

In <strong>de</strong> tabellen 5 en 6 zijn <strong>de</strong> waar<strong>de</strong>n voor cpe,1 (1 m²) en cpe,10 (10 m²) <strong>op</strong>gegeven, afhankelijk<br />

<strong>van</strong> <strong>de</strong> verhouding tussen h/d en e/d.<br />

Tabel 5 cpe,10.<br />

Zones<br />

1<br />

2<br />

Tabel 6 cpe,1.<br />

Zones<br />

1<br />

2<br />

h p<br />

e/5<br />

2<br />

Afbeelding 23 Verticale gevel : integratie <strong>van</strong> <strong>de</strong> windrichtingen - cpe.<br />

− b : breedte <strong>van</strong> <strong>de</strong> beschouw<strong>de</strong> gevel (in dit geval een puntgevel)<br />

− d : afmeting <strong>van</strong> <strong>de</strong> gevel loodrecht <strong>op</strong> <strong>de</strong> beschouw<strong>de</strong> gevel<br />

− h : hoogte <strong>van</strong> <strong>de</strong> beschouw<strong>de</strong> gevel<br />

− hf : hoogte <strong>van</strong> <strong>de</strong> dakrand voor een gevel zon<strong>de</strong>r dak of bij afwezigheid <strong>van</strong> een<br />

puntgevel<br />

− hp : hoogte <strong>van</strong> <strong>de</strong> nok in aanwezigheid <strong>van</strong> een puntgevel<br />

− e : minimumwaar<strong>de</strong> <strong>van</strong> b en 2h<br />

cpe,10 voor 0,25 < h/d < 5 cpe,10 voor h/d ≤ 0,25<br />

e < 5d e ≥ 5d e < 5d e ≥ 5d<br />

cpe = -0,8<br />

cpe = 0,8<br />

cpe = -1,2<br />

cpe = 0,8<br />

cpe,1 voor h/d < 5<br />

e < 5d e ≥ 5d<br />

cpe = -1,1<br />

cpe = 1,0<br />

cpe = -1,4<br />

cpe = 1,0<br />

1<br />

b<br />

cpe = -1,2<br />

cpe = -0,8<br />

cpe = 0,7<br />

cpe = 0,8 cpe = -1,2<br />

cpe = 0,7<br />

cpe = -1,4<br />

cpe = 1,0<br />

e = minimum<br />

<strong>van</strong> b of 2h<br />

cpe = -1,2<br />

cpe = 0,7<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

e/5<br />

1 2<br />

d<br />

h f<br />

36


Nota 15 : afbeelding 23 illustreert <strong>de</strong> situatie in <strong>het</strong> geval <strong>van</strong> een puntgevel. Hierbij wordt exact<br />

<strong>de</strong>zelf<strong>de</strong> re<strong>de</strong>nering gevolgd als voor <strong>de</strong> hoofdgevel, met uitzon<strong>de</strong>ring <strong>van</strong> <strong>het</strong> feit dat « b » <strong>de</strong><br />

breedte <strong>van</strong> <strong>de</strong> gevel wordt en « d » <strong>de</strong> breedte <strong>van</strong> <strong>de</strong> puntgevel. De te beschouwen hoogte<br />

wordt dan h f .<br />

De tussenliggen<strong>de</strong> h/d-waar<strong>de</strong>n wor<strong>de</strong>n verkregen door lineaire interpolatie. De cpe-waar<strong>de</strong>n<br />

voor <strong>op</strong>pervlakken tussen 1 en 10 m² wor<strong>de</strong>n verkregen door een interpolatie volgens <strong>de</strong> regel<br />

uit afbeelding 19. Men kan hiertoe tevens een beroep doen <strong>op</strong> <strong>de</strong> grafieken uit afbeelding 24.<br />

c pe<br />

c pe<br />

1,05<br />

1,00<br />

0,95<br />

0,90<br />

0,85<br />

0,80<br />

0,75<br />

0,70<br />

c pe - Gevels - Overdruk<br />

_____ (i) zone 1 als 0,25 < h/d < 5 – zone 2 als 0,25 < h/d < 5<br />

(i) zone 1 als 0,25


Geval <strong>van</strong> daken met één dakschild – Bepaling <strong>van</strong> <strong>de</strong> zones F, G, H en I<br />

In <strong>het</strong> geval <strong>van</strong> daken met één dakschild gebeurt <strong>de</strong> berekening :<br />

− ofwel voor <strong>de</strong> vier windrichtingen afzon<strong>de</strong>rlijk. Deze vier gevallen wor<strong>de</strong>n voorgesteld<br />

in afbeelding 25<br />

− ofwel door <strong>het</strong> integreren <strong>van</strong> <strong>de</strong> vier windrichtingen, zoals aangegeven in <strong>de</strong><br />

afbeeldingen 26 en 27.<br />

Daken waar<strong>van</strong> <strong>de</strong> helling meer dan 75° bedraagt ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong> horizontale kunnen, voor<br />

wat betreft <strong>de</strong> windbelasting, gelijkgesteld wor<strong>de</strong>n met gevels.<br />

Afzon<strong>de</strong>rlijk genomen windrichtingen<br />

Men dient <strong>het</strong> dak (met inbegrip <strong>van</strong> <strong>de</strong> dakoversteken R) in te <strong>de</strong>len in zones zoals voorgesteld<br />

in afbeelding 25. De te gebruiken referentiehoogte ze is gelijk aan <strong>het</strong> niveauverschil tussen h en<br />

z = 0.<br />

De drukcoëfficiënten die voor elke zone gebruikt moeten wor<strong>de</strong>n, zijn vermeld in tabel 7. Voor<br />

<strong>de</strong> dakoversteken R verwijzen we naar <strong>de</strong> voorschriften met betrekking tot elementen in reliëf<br />

(§ 4.1.2.5.4).<br />

Waar<strong>de</strong> voor cpe,1 (1 m²) en cpe,10 (10 m²), afhankelijk <strong>van</strong> <strong>de</strong> zones F, G, H, I <strong>van</strong> een dak met<br />

één enkel dakschild<br />

Tabel 7 geeft een overzicht <strong>van</strong> <strong>de</strong> waar<strong>de</strong>n <strong>van</strong> cpe,1 (1 m²) en cpe,10 (10 m²), naargelang <strong>van</strong> <strong>de</strong><br />

windrichting en <strong>de</strong> dakhelling. Voor tussenliggen<strong>de</strong> hellingshoeken kan een lineaire interpolatie<br />

wor<strong>de</strong>n toegepast tussen waar<strong>de</strong>n met eenzelf<strong>de</strong> teken. De waar<strong>de</strong>n F, G, H, I zijn eveneens<br />

<strong>op</strong>genomen in tabel 7.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

38


Tabel 7 Buitendrukcoëfficiënten <strong>van</strong> toepassing <strong>op</strong> daken met één enkel dakschild.<br />

Hellingshoek<br />

α<br />

5°<br />

15°<br />

30°<br />

45°<br />

Zone voor windrichting θ = 0° Zone voor windrichting θ = 180°<br />

F G H F G H<br />

cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1<br />

-1,7 -2,5 -1,2 -2 ,0 -0,6 -1,2<br />

+ 0,0 + 0,0 + 0,0<br />

-0,9 -2,0 -0,8 -1,5 -0,3<br />

+ 0,2 + 0,2 + 0,2<br />

-0,5 -1,5 -0,5 -1,5 -0,2<br />

+ 0,7 + 0,7 + 0,4<br />

-0,0 -0,0 -0,0<br />

+ 0,7 + 0,7 + 0,6<br />

-2,3 -2,5 -1,3 -2,0 -0,8 -1,2<br />

-2,5 -2,8 -1 ,3 -2,0 -0,9 -1,2<br />

-1,1 -2,3 -0,8 -1,5 -0,8<br />

-0,6 -1,3 -0,5 -0,7<br />

60° + 0,7 + 0,7 + 0,7 -0,5 -1,0 -0,5 -0,5<br />

75° + 0,8 + 0,8 + 0,8 -0,5 -1,0 -0,5 -0,5<br />

Hellingshoek<br />

α<br />

Zone voor windrichting θ = 90°<br />

Fsup Finf G H I<br />

cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1<br />

5° -2,1 -2,6 -2,1 -2,4 -1,8 -2,0 -0,6 -1,2 -0,5<br />

15° -2,4 -2,9 -1,6 -2,4 -1,9 -2,5 -0,8 -1,2 -0,7 -1,2<br />

30° -2,1 -2,9 -1,3 -2,0 -1,5 -2,0 -1,0 -1,3 -0,8 -1,2<br />

45° -1,5 -2,4 -1,3 -2,0 -1,4 -2,0 -1,0 -1,3 -0,9 -1,2<br />

60° -1,2 -2,0 -1,2 -2,0 -1,2 -2,0 -1,0 -1,3 -0,7 -1,2<br />

75° -1,2 -2,0 -1,2 -2,0 -1,2 -2,0 -1,0 -1,3 -0,5<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

39


On<strong>de</strong>rste dakrand<br />

Wind θ = 0°<br />

α<br />

e 1 /4<br />

Wind θ = 0°<br />

e 2 /2<br />

e 1 /4<br />

e 2 /10<br />

R<br />

On<strong>de</strong>rste dakrand<br />

F 0°<br />

G 0°<br />

F 0°<br />

e 1 /10<br />

H 0°<br />

b 2<br />

Wind θ = 90° (+)<br />

e 2 /4 e 2 /4<br />

F 90°Inf G 90° F 90°sup<br />

H 90°<br />

I 90°<br />

Bovenste dakrand<br />

z e =h<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

b 1<br />

h<br />

On<strong>de</strong>rste dakrand<br />

Wind θ = 180°<br />

H 180°<br />

Bovenste dakrand<br />

e 1 /10<br />

Bovenste dakrand<br />

F 180°<br />

G 180°<br />

F 180°<br />

e 1 /4<br />

Referentiehoogte z e =h<br />

ei = minimum e i = minimum <strong>van</strong><br />

tussen bi en 2h<br />

b i en 2h<br />

b b i = loodrecht <strong>op</strong> <strong>de</strong><br />

wind<br />

Afbeelding 25 Bepaling <strong>van</strong> <strong>de</strong> zones <strong>van</strong> toepassing <strong>op</strong> daken met één dakschild.<br />

Wind θ = 180°<br />

e 1 /4<br />

40


Integratie <strong>van</strong> <strong>de</strong> vier windrichtingen voor een dak met één enkel dakschild<br />

Als <strong>de</strong> windbelasting bepaald wordt door <strong>de</strong> integratie <strong>van</strong> <strong>de</strong> vier windrichtingen, is <strong>het</strong> nodig<br />

om <strong>de</strong> aldus bekomen cpe-waar<strong>de</strong>n (zie afbeelding 28) samen te stellen met <strong>de</strong> hoeksector die <strong>de</strong><br />

meest ongunstige ruwheidscategorie <strong>van</strong> <strong>de</strong> vier windrichtingen vertoont : θ = 0°, 90°, 90°(+) en<br />

180°.<br />

Aan <strong>de</strong> hand <strong>van</strong> <strong>de</strong> zones F, G, H en I uit afbeelding 18 wor<strong>de</strong>n in afbeelding 26 <strong>de</strong> vier<br />

windrichtingen θ = 0°, 90°, 90°(+) en 180° gecombineerd.<br />

Men kan negen verschillen<strong>de</strong> dakzones on<strong>de</strong>rschei<strong>de</strong>n die elk een specifieke windcombinatie<br />

vertonen (afbeelding 27).<br />

e 2 /2<br />

Wind θ = 0°<br />

e 2 /2<br />

e 2 /10<br />

e 1 /4<br />

e e1/4 1/4<br />

e 2 /10<br />

F 0°<br />

G 0°<br />

F 0°<br />

e 1 /10<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

Wind θ = 90°<br />

On<strong>de</strong>rste dakrand e 2 /4 e 2 /4 Bovenste dakrand<br />

F 90°Inf G 90° F 90°sup<br />

H 90°<br />

H 180°<br />

I 90°<br />

H 0°<br />

H 90° I 90°<br />

b 2<br />

F 180°<br />

G 180°<br />

F F90°Inf G F<br />

90°Inf G F 90° 90° 90°sup<br />

F 180° e e1/4 1/4<br />

e 1 /10<br />

e 2 /4 e 2 /4<br />

e 1 /4<br />

Afbeelding 26 Vier windrichtingen <strong>op</strong> een dak met één enkel dakschild.<br />

b 1<br />

Wind θ = 180°<br />

41


e e2/2 2/2<br />

On<strong>de</strong>rste dakrand e 2 /4 e 2 /4 Bovenste dakrand<br />

e 2 /2<br />

e<br />

e e1 /4 2/10<br />

1 /4 2/10<br />

e 1 /4<br />

e 2 /10<br />

F 90°Inf G 90° F 90°sup<br />

3 4 5 6 7<br />

F 2 0°<br />

10<br />

F 180° 8<br />

1<br />

H H90° 90° I 90°<br />

9<br />

G 0° H G 0° 180°<br />

F 0°<br />

e e1/10 1/10<br />

H 90° I 90°<br />

F 90°Inf G 90° F 90°sup<br />

e e2/4 2/4<br />

H 180°<br />

F 180° e e1/4 1/4<br />

e 1 /10<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

b 2<br />

Afbeelding 27 Dak met één enkel dakschild – In<strong>de</strong>ling in zones met verschillen<strong>de</strong><br />

windrichtingscombinaties.<br />

Nota 16 :<br />

Voor gebouwen met bepaal<strong>de</strong> geometrische vormen, kan men te maken krijgen met <strong>de</strong> volgen<strong>de</strong> situaties :<br />

1. e2 /10 ≥ e1 /4<br />

– <strong>de</strong> zone 3 be<strong>de</strong>kt <strong>de</strong> zone 2 (<strong>de</strong> randzone b2 is bre<strong>de</strong>r) : <strong>de</strong> cpe-waar<strong>de</strong>n <strong>van</strong> <strong>de</strong> zone 3 zijn<br />

toepasbaar <strong>op</strong> <strong>de</strong> zone 2<br />

– <strong>de</strong> zone 7 be<strong>de</strong>kt <strong>de</strong> zone 8 (<strong>de</strong> randzone b is bre<strong>de</strong>r) : <strong>de</strong> c -waar<strong>de</strong>n <strong>van</strong> <strong>de</strong> zone 7 zijn<br />

2 pe<br />

toepasbaar <strong>op</strong> zone 8<br />

e2/10 ≥ e1/4<br />

e e2/2 2/2<br />

e e1 /4 e<br />

1 /4 e2/10 2/10<br />

e 1 /10<br />

b 2<br />

e e2/4 2/4<br />

e e1/10 1/10<br />

e e1/4 1/4<br />

On<strong>de</strong>rste dakrand<br />

e e2/10 2/10 e e1/4 1/4<br />

Bovenste Bovenste dakrand<br />

e e2/4 2/4 e e2/4 2/4<br />

3 4 5 6 7<br />

1<br />

2. e 1 /10 ≥ e 2 /4<br />

– <strong>de</strong> zone 3 be<strong>de</strong>kt <strong>de</strong> zone 4 (<strong>de</strong> randzone b 1 is bre<strong>de</strong>r) : <strong>de</strong> c pe -waar<strong>de</strong>n <strong>van</strong> <strong>de</strong> zone 3 zijn<br />

toepasbaar <strong>op</strong> <strong>de</strong> zone 4<br />

– <strong>de</strong> zone 7 be<strong>de</strong>kt <strong>de</strong> zone 6 (<strong>de</strong> randzone b 1 is bre<strong>de</strong>r) : <strong>de</strong> c pe -waar<strong>de</strong>n <strong>van</strong> <strong>de</strong> zone 7 zijn<br />

toepasbaar <strong>op</strong> <strong>de</strong> zone 6<br />

e 1 /4<br />

e 2 /10<br />

e 1 /10<br />

10<br />

e 1 /10<br />

9<br />

e 1 /4<br />

e e1/4 1/4<br />

b 1 /2<br />

b 1<br />

b 1 /2<br />

On<strong>de</strong>rste dakrand<br />

Bovenste dakrand<br />

e1/10 e 1 /10 ≥ e2/4<br />

e 2 /4<br />

e 2 /4 e 2 /4<br />

3 5 7<br />

2 8<br />

1<br />

10<br />

b2<br />

3. e 2 /2 = b 1 /2 omdat in <strong>de</strong> betrokken zone rekening gehou<strong>de</strong>n werd met <strong>de</strong> c pe -waar<strong>de</strong>n <strong>van</strong> <strong>de</strong> zone I 90°<br />

<strong>van</strong> <strong>de</strong> windrichting θ = 90°(+) en met <strong>de</strong>ze <strong>van</strong> <strong>de</strong> zone H 90° <strong>van</strong> <strong>de</strong> windrichting θ = 90°.<br />

9<br />

42


c pe<br />

1<br />

0,75<br />

0,5<br />

0,25<br />

-0,5<br />

-0,75<br />

-1<br />

-1,25<br />

-1,5<br />

-1,75<br />

-2<br />

Zodoen<strong>de</strong> verkrijgt men <strong>de</strong> tabel 8 die <strong>op</strong>gesteld moet wor<strong>de</strong>n voor cpe,1 en cpe,10 en voor hoeken<br />

<strong>van</strong> 5°, 15°, 30°, 45°, 60° en 75°. Gelet <strong>op</strong> <strong>de</strong> symmetrie <strong>van</strong> <strong>de</strong> belastingen en <strong>van</strong> <strong>het</strong> gebouw<br />

dient men 10 zones te analyseren.<br />

Tabel 8 Zones <strong>van</strong> cpe afhankelijk <strong>van</strong> <strong>de</strong> zones <strong>van</strong> een dak met één enkel dakschild.<br />

Zones Wind θ = 0° Wind θ = 90° Wind θ = 180° Wind θ = 90° (+)<br />

1. G0 H90 H180 I90<br />

2. F0 H90 H180 I90<br />

3. F0 F90 inf H180 I90<br />

4. H0 F90 inf H180 I90<br />

5. H0 G90 H180 I90<br />

6. H0 F90 sup H180 I90<br />

7. H0 F90 sup F180 I90<br />

8. H0 H90 F180 I90<br />

9. H0 H90 G180 I90<br />

10. H0 H90 H180 I90<br />

Door <strong>de</strong> integratie <strong>van</strong> <strong>de</strong> vier windrichtingen verkrijgt men <strong>de</strong> grafieken <strong>van</strong> afbeelding 28,<br />

waarin men naargelang <strong>van</strong> <strong>de</strong> dakhelling voor elke zone uit afbeelding 27 <strong>de</strong> positieve en<br />

negatieve waar<strong>de</strong>n <strong>van</strong> <strong>de</strong> buitendrukcoëfficiënten terugvindt voor belastings<strong>op</strong>pervlakken A <strong>van</strong><br />

1 m² (cpe,1) en <strong>van</strong> 10 m² (cpe,10). Voor tussenliggen<strong>de</strong> <strong>op</strong>pervlaktewaar<strong>de</strong>n A verwijzen we naar<br />

afbeelding 19.<br />

In bijlage 3 zijn <strong>de</strong> <strong>de</strong>tails <strong>van</strong> <strong>de</strong> berekeningen <strong>op</strong>genomen.<br />

Eén Enkelafhellen<strong>de</strong> enkel dakschild daken – cpe,10-cpe,1 - c pe,10 c – pe,1 - Zone 1 1 Eén Enkelafhellen<strong>de</strong> enkel dakschild daken – cpe,10-cpe,1<br />

- c pe,10 c pe,1 – - Zone 2<br />

1<br />

0<br />

-0,25 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

c pe<br />

1<br />

0,75<br />

0,5<br />

0,25<br />

0<br />

-0,5<br />

-0,75<br />

-1<br />

-1,25<br />

-1,5<br />

-1,75<br />

-2<br />

-2,25<br />

-2,5<br />

Dakhelling θ°<br />

Cpe,10<br />

Cpe,1<br />

-0,25 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

c pe<br />

0,75<br />

0,5<br />

0,25<br />

0<br />

-0,5<br />

-0,75<br />

-1<br />

-1,25<br />

-1,5<br />

-1,75<br />

-2<br />

-2,25<br />

Enkelafhellen<strong>de</strong> daken - c pe,10 c pe,1 - Zone 3<br />

Enkelafhellen<strong>de</strong> daken - c pe,10 c pe,1 - Zone 4<br />

Eén enkel dakschild – cpe,10-cpe,1 – Zone 3 Eén enkel dakschild – cpe,10-cpe,1 – Zone 4<br />

1<br />

-0,25 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

Dakhelling θ°<br />

Cpe,10<br />

Cpe,1<br />

-2,5<br />

c pe<br />

0,75<br />

0,5<br />

0,25<br />

0<br />

-0,25<br />

-0,5<br />

-0,75<br />

-1<br />

-1,25<br />

-1,5<br />

-1,75<br />

-2<br />

-2,25<br />

-2,5<br />

Dakhelling θ°<br />

Cpe,10<br />

Cpe,1<br />

5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

Dakhelling θ°<br />

Cpe,10<br />

Cpe,1<br />

43


C pe<br />

1<br />

Enkelafhellen<strong>de</strong> daken - c pe,10 c pe,1 - Zone 5<br />

Eén enkel dakschild – cpe,10-cpe,1 – Zone 5<br />

1<br />

Enkelafhellen<strong>de</strong> daken - c pe,10 c pe,1 - Zone 6<br />

Eén enkel dakschild – cpe,10-cpe,1 – Zone 6<br />

0,75<br />

0,75<br />

0,5<br />

0,5<br />

0,25<br />

0<br />

-0,25 5<br />

-0,5<br />

-0,75<br />

10 15 20 25 30 35 40 45 50 55 60 65 70<br />

Dakhelling θ°<br />

75<br />

0,25<br />

0<br />

-0,25 5<br />

-0,5<br />

-0,75<br />

-1<br />

10 15 20 25 30 35 40 45 50 55 60 65<br />

Dakhelling θ°<br />

70 75<br />

-1<br />

-1,25<br />

-1,25<br />

-1,5<br />

-1,5<br />

-1,75<br />

-2<br />

-2,25<br />

Cpe,10<br />

Cpe,1<br />

-1,75<br />

-2<br />

-2,25<br />

-2,5<br />

-2,75<br />

Cpe,10<br />

Cpe,1<br />

-2,5<br />

-3<br />

c pe<br />

1<br />

0,75<br />

0,5<br />

0,25<br />

0<br />

-0,25<br />

-0,5<br />

-0,75<br />

-1<br />

-1,25<br />

-1,5<br />

-1,75<br />

-2<br />

-2,25<br />

-2,5<br />

-2,75<br />

-3<br />

c pe<br />

1<br />

0,75<br />

0,5<br />

0,25<br />

0<br />

-0,5<br />

-0,75<br />

-1<br />

-1,25<br />

-1,5<br />

-1,75<br />

-2<br />

Enkelafhellen<strong>de</strong> Eén enkel dakschild daken - c – cpe,10-cpe,1<br />

pe,10 c pe,1 - Zone – 7Zone<br />

7<br />

5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

Dakhelling θ°<br />

Cpe,10<br />

Cpe,1<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

c pe<br />

c pe<br />

1<br />

0,75<br />

0,5<br />

0,25<br />

0<br />

-0,25<br />

-0,5<br />

-0,75<br />

-1<br />

-1,25<br />

-1,5<br />

-1,75<br />

-2<br />

-2,25<br />

-2,5<br />

-2,75<br />

-3<br />

Enkelafhellen<strong>de</strong> daken - c pe,10 c pe,1 - Zone 8<br />

Eén enkel dakschild – cpe,10-cpe,1 – Zone 8<br />

5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

Eén Enkelafhellen<strong>de</strong> enkel dakschild daken – - ccpe,10-cpe,1 pe,10 c pe,1 - Zone – Zone 9 9 Eén<br />

Enkelafhellen<strong>de</strong><br />

enkel dakschild<br />

daken -<br />

– cpe,10-cpe,1 c pe,10 c pe,1 - Zone<br />

– Zone<br />

10<br />

10<br />

-0,25 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

Dakhelling θ°<br />

Cpe,10<br />

Cpe,1<br />

cpe<br />

1<br />

0,75<br />

0,5<br />

0,25<br />

0<br />

-0,75<br />

-1<br />

-1,25<br />

-1,5<br />

Dakhelling θ°<br />

Cpe,10<br />

Cpe,1<br />

5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

-0,25<br />

Dakhelling θ°<br />

-0,5<br />

Afbeelding 28 cpe,1- en cpe,10-coëfficiënten voor een dak met één enkel dakschild – Krommen voor<br />

<strong>de</strong> vier windrichtingen.<br />

Geval <strong>van</strong> daken met twee dakschil<strong>de</strong>n – Bepaling <strong>van</strong> <strong>de</strong> zones F, G, H, I en J<br />

In dit geval gebeurt <strong>de</strong> berekening :<br />

− ofwel voor <strong>de</strong> vier windrichtingen afzon<strong>de</strong>rlijk. De vier gevallen wor<strong>de</strong>n voorgesteld in<br />

afbeelding 29 en tabel 9<br />

− ofwel door <strong>het</strong> integreren <strong>van</strong> <strong>de</strong> vier windrichtingen, zoals aangegeven in afbeelding 30<br />

en tabel 10.<br />

Cpe,10<br />

Cpe,1<br />

44


Afzon<strong>de</strong>rlijk genomen windrichtingen<br />

Het dak wordt inge<strong>de</strong>eld in zones, zoals voorgesteld in afbeelding 29. De te gebruiken<br />

referentiehoogte ze is gelijk aan <strong>het</strong> niveauverschil tussen z = 0 en h. De drukcoëfficiënten die<br />

voor elke zone gebruikt moeten wor<strong>de</strong>n, zijn vermeld in tabel 9.<br />

Waar<strong>de</strong> <strong>van</strong> cpe,1 (1 m²) en cpe,10 (10 m²), afhankelijk <strong>van</strong> <strong>de</strong> zones F, G, H en I <strong>van</strong> een dak<br />

met twee dakschil<strong>de</strong>n<br />

Tabel 9 geeft een overzicht <strong>van</strong> <strong>de</strong> waar<strong>de</strong>n <strong>van</strong> cpe,1 (1 m²) en cpe,10 (10 m²), naargelang <strong>van</strong><br />

<strong>de</strong> windrichting en <strong>de</strong> dakhelling.<br />

Tabel 9 Buitendrukcoëfficiënten <strong>van</strong> toepassing <strong>op</strong> daken met twee dakschil<strong>de</strong>n.<br />

Zone voor <strong>de</strong> windrichtingen θ = 0°, θ = 180°<br />

Hellingshoek α<br />

F G H I J<br />

cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1<br />

-45° -0,6 -0,6 -0,8 -0,7 -1,0 -1,5<br />

-30° -1,1 -2,0 -0,8 -1,5 -0,8 -0,6 -0,8 -1,4<br />

-15° -2,5 -2,8 -1,3 -2,0 -0,9 -1,2 -0,5 -0,7 -1,2<br />

-5° -2,3 -2,5 -1,2 -2,0 -0,8 -1,2<br />

5°<br />

15°<br />

30°<br />

45°<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

+0,2 +0,2<br />

-0,6 -0,6<br />

-1,7 -2,5 -1,2 -2,0 -0,6 -1,2 +0,2 +0,2<br />

+0,0 +0,0 +0,0 -0,6 -0,6<br />

-0,9 -2,0 -0,8 -1,5 -0,3 -0,4 -1,0 -1,5<br />

+0,2 +0,2 +0,2 +0,0 +0,0 +0,0<br />

-0,5 -1,5 -0,5 -1,5 -0,2 -0,4 -0,5<br />

+0,7 +0,7 +0,4 +0,0 +0,0<br />

-0,0 -0,0 -0,0 -0,2 -0,3<br />

+0,7 +0,7 +0,6 +0,0 +0,0<br />

60° +0,7 +0,7 +0,7 -0,2 -0,3<br />

75° +0,8 +0,8 +0,8 -0,2 -0,3<br />

Hellingshoek α<br />

Zone voor <strong>de</strong> windrichting θ = 90°<br />

F G H I<br />

cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1<br />

-45° -1,4 -2,0 -1,2 -2,0 -1,0 -1,3 -0,9 -1,2<br />

-30° -1,5 -2,1 -1,2 -2,0 -1,0 -1,3 -0,9 -1,2<br />

-15° -1,9 -2,5 -1,2 -2,0 -0,8 -1,2 -0,8 -1,2<br />

-5° -1,8 -2,5 -1,2 -2,0 -0,7 -1,2 -0,6 -1,2<br />

5° -1,6 -2,2 -1,3 -2,0 -0,7 -1,2 -0,6<br />

15° -1,3 -2,0 -1,3 -2,0 -0,6 -1,2 -0,5<br />

30° -1,1 -1,5 -1,4 -2,0 -0,8 -1,2 -0,5<br />

45° -1,1 -1,5 -1,4 -2,0 -0,9 -1,2 -0,5<br />

60° -1,1 -1,5 -1,2 -2,0 -0,8 -1,0 -0,5<br />

75° -1,1 -1,5 -1,2 -2,0 -0,8 -1,0 -0,5<br />

Nota 1 : bij θ = 0°, slaat <strong>de</strong> druk <strong>op</strong> <strong>het</strong> dakschild tegen <strong>de</strong> wind (hellingshoek α gaan<strong>de</strong> <strong>van</strong> -5° tot +45°) zeer snel<br />

om <strong>van</strong> een positieve tot een negatieve waar<strong>de</strong>. Dit verklaart waarom er voor <strong>de</strong>ze hellingen zowel positieve als<br />

negatieve waar<strong>de</strong>n <strong>op</strong>genomen zijn. Voor <strong>de</strong>ze daken dient men vier situaties te beschouwen waarbij <strong>de</strong> grootste of<br />

<strong>de</strong> kleinste waar<strong>de</strong>n uit <strong>de</strong> zones F, G en H gecombineerd wor<strong>de</strong>n met <strong>de</strong> grootste of <strong>de</strong> kleinste waar<strong>de</strong>n uit <strong>de</strong><br />

zones I en J. Het mengen <strong>van</strong> positieve en negatieve waar<strong>de</strong>n <strong>op</strong> eenzelf<strong>de</strong> dakschild is niet toegelaten.<br />

Nota 2 : voor tussenliggen<strong>de</strong> hellingshoeken met <strong>het</strong>zelf<strong>de</strong> teken kan een lineaire interpolatie uitgevoerd wor<strong>de</strong>n<br />

tussen waar<strong>de</strong>n met <strong>het</strong>zelf<strong>de</strong> teken (men mag geen interpolatie uitvoeren tussen α = +5° en α = -5°; in dit geval<br />

dient men <strong>de</strong> gegevens te gebruiken die in § 7.2.3 <strong>van</strong> <strong>de</strong> norm EN 1991-1-4 <strong>op</strong>genomen zijn voor dakterassen). De<br />

waar<strong>de</strong>n gelijk aan 0,0 zijn <strong>op</strong>gegeven met <strong>het</strong> oog <strong>op</strong> <strong>de</strong>ze interpolatie.<br />

45


wind<strong>op</strong>waartse<br />

Dakschild<br />

tegen <strong>de</strong> wind<br />

zij<strong>de</strong><br />

α > 0<br />

α > 0<br />

Wind θ = 0° α<br />

α<br />

e 1 /4<br />

Wind θ = 0°<br />

e 2 /2<br />

e 1 /4<br />

e ee2/10 2/10 2/10 2/10<br />

F 0°<br />

G 0°<br />

F 0°<br />

e e2/4 2/4 2/4 2/4<br />

Positieve<br />

aanvalshoek<br />

hellingshoek<br />

H 0°<br />

e 1 /10<br />

H 90°<br />

I 90°<br />

b 2<br />

windafwaartse<br />

Dakschild<br />

on<strong>de</strong>r <strong>de</strong> wind<br />

zij<strong>de</strong><br />

z e =h<br />

Wind θ = 90°<br />

α<br />

α<br />

Referentiehoogte z e =h<br />

ei = minimum<br />

e e i = minimum<br />

<strong>van</strong> bi en 2h<br />

tussen b i en 2h<br />

bi bi = = loodrecht loodrecht <strong>op</strong> <strong>op</strong> <strong>de</strong><br />

<strong>de</strong><br />

wind<br />

wind<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

h<br />

b 1<br />

I 180°<br />

α<br />

α<br />

Negatieve<br />

hellingshoek aanvalshoek<br />

J 0° I J 0° I J 0° I J 0° I J 0° 0° 0° 0° 180°<br />

e 1 /10 e 1 /10<br />

H 90°<br />

I 90°<br />

e e2/4 2/4 2/4 2/4<br />

F 90° G 90° F90°<br />

G 90°<br />

e 2 /10<br />

e e1/10 1/10 1/10 1/10<br />

F 180°<br />

H 180° G 180°<br />

F 180°<br />

Afbeelding 29 Bepaling <strong>van</strong> <strong>de</strong> zones <strong>van</strong> een dak met twee dakschil<strong>de</strong>n.<br />

bi<br />

z ze=h e=h e=h e=h<br />

Wind θ = 180°<br />

e 1 /4<br />

Wind θ = 180°<br />

e e1/4 1/4 1/4 1/4<br />

46


Integratie <strong>van</strong> <strong>de</strong> vier windrichtingen voor een dak met twee dakschil<strong>de</strong>n<br />

Als <strong>de</strong> windbelasting bepaald wordt door <strong>de</strong> integratie <strong>van</strong> <strong>de</strong> vier windrichtingen, is <strong>het</strong> nodig<br />

om <strong>de</strong> aldus bekomen cpe-coëfficiënten (zie afbeelding 32) samen te stellen met <strong>de</strong> hoeksector<br />

die <strong>de</strong> meest ongunstige ruwheidscategorie <strong>van</strong> <strong>de</strong> vier windrichtingen vertoont : θ = 0°, 90°,<br />

90°(+) en 180°. Aan <strong>de</strong> hand <strong>van</strong> <strong>de</strong> zones F, G, H, I en J uit afbeelding 29 wor<strong>de</strong>n in afbeelding<br />

30 <strong>de</strong> vier windrichtingen θ = 0°, 90°, 90°(+) en 180° gecombineerd.<br />

e e2/2 2/2<br />

Wind θ = 0°<br />

e e2/2 2/2<br />

e e2/10 2/10<br />

e e1/4 1/4<br />

e 1 /4<br />

e e2/10 2/10<br />

e e2/4 2/4 e e2/4 2/4<br />

F 90°<br />

e e1/10 i = minimum e e1/10 1/10<br />

i = minimum<br />

tussen b i en 2h e e2/4 2/4<br />

bi = afmeting<br />

b b i = maat loodrecht <strong>op</strong><br />

<strong>de</strong> wind<br />

Wind θ = 90°<br />

G 90°<br />

Wind θ = 90°(+)<br />

G G90° 90°<br />

F 0° H H F<br />

90°<br />

90° F 180°<br />

I 90°(+) J I<br />

180° 90°(+)<br />

H H0° J I 0° J I 0° 0°<br />

G 0°<br />

I H<br />

180°<br />

180° G 180°<br />

180°<br />

I 180°<br />

G 0°<br />

H 90°(+)<br />

J 180°<br />

H 0°<br />

F 0° I 90°<br />

F 180°<br />

F F90°(+) G90°(+) G90°(+) F 90°(+) G90°(+) G90°(+) F90°(+) 90°(+)<br />

e e1/10 1/10 e e1/10 1/10 1/10<br />

e 1 /10<br />

e e2/4 2/4 2/4<br />

e 1 /4<br />

b 1<br />

Wind θ = 180 °<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

b 2<br />

H 180°<br />

H 90°(+)<br />

I 90°<br />

F 90°<br />

J 0° I 0°<br />

G 180°<br />

e e1/4 1/4<br />

Afbeelding 30 Vier windrichtingen <strong>op</strong> een dak met twee dakschil<strong>de</strong>n.<br />

Gelet <strong>op</strong> <strong>de</strong> symmetrie <strong>van</strong> <strong>het</strong> gebouw en <strong>van</strong> <strong>de</strong> windbelasting, kan men acht windzones<br />

on<strong>de</strong>rschei<strong>de</strong>n, die elk een specifieke windcombinatie vertonen (afbeelding 31). Zodoen<strong>de</strong><br />

verkrijgt men <strong>de</strong> tabel 10 die <strong>op</strong>gesteld moet wor<strong>de</strong>n voor cpe,1 en cpe,10 en voor hoeken <strong>van</strong><br />

-45°, -30°, -15°, -5°, 5°, 15°, 30°, 45°, 60° en 75°.<br />

e e2/2 2/2 2/2<br />

Wind θ = 0°<br />

e 2 /2<br />

e e2/10 2/10 2/10<br />

e 1 /4<br />

e 1 /4<br />

e 2 /10<br />

e e2/4 2/4 2/4 e 2 /4<br />

3 F 90° 4 5 G 90° 6 G 90° F 90°<br />

F 2 0°<br />

1<br />

G 0°<br />

H 90°<br />

I90°(+)<br />

8 H 7<br />

0°<br />

I I180° 180° 180° J 180°<br />

J 0°<br />

H 90°<br />

I 90°(+)<br />

I 0°<br />

H H180° 180° 180°<br />

F 180°<br />

G G180° 180° 180°<br />

G G0° 0° 0°<br />

F 0°<br />

e 1 /10<br />

e 2 /4<br />

Wind θ = 90°<br />

I 180°<br />

H<br />

J 180°<br />

90°(+)<br />

H 0°<br />

I I90° 90° 90°<br />

F F90°(+) G90°(+) G90°(+) F 90°(+) G90°(+) F 90°(+) G90°(+) G90°(+) G90°(+) F 90°(+)<br />

Wind θ = 90°(+)<br />

e 1 /10 e 1 /10<br />

b 2<br />

H 180°<br />

H<br />

G 180°<br />

90°(+) 90°(+) 90°(+)<br />

J 0° I 0°<br />

I I90° 90° 90°<br />

F F180° 180° 180°<br />

e 1 /10<br />

e e2/4 2/4 2/4 2/4<br />

e 1 /4<br />

e 1 /4<br />

b 1<br />

Wind θ = 180 °<br />

Afbeelding 31 Dak met twee dakschil<strong>de</strong>n – In<strong>de</strong>ling in zones met verschillen<strong>de</strong><br />

windrichtingscombinaties.<br />

47


Nota 17<br />

Voor gebouwen met bepaal<strong>de</strong> geometrische vormen, kan men te maken krijgen met <strong>de</strong> volgen<strong>de</strong> situaties :<br />

1. e2 /10 ≥ e1 /4 : <strong>de</strong> zone 3 be<strong>de</strong>kt <strong>de</strong> zone 2 (<strong>de</strong> randzone b2 is bre<strong>de</strong>r) : <strong>de</strong> cpe-waar<strong>de</strong>n <strong>van</strong> <strong>de</strong> zone 3<br />

zijn toepasbaar <strong>op</strong> <strong>de</strong> zone 2<br />

e2/10 e e≥ 2 /10 e1/4 e 1 /4<br />

On<strong>de</strong>rste dakrand e 2 /4<br />

Nok<br />

e 2 /2<br />

e e1 /4 e2 /10<br />

1 /4 e2 /10<br />

3 4 5<br />

1<br />

e 1 /10<br />

b 2 /2<br />

e e1/10 1/10<br />

e 1 /4<br />

b 1 /2<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

8<br />

2. e /10 ≥ e /4 : <strong>de</strong> zone 3 be<strong>de</strong>kt <strong>de</strong> zone 4 (<strong>de</strong> randzone b is bre<strong>de</strong>r) : <strong>de</strong> c -waar<strong>de</strong>n <strong>van</strong> <strong>de</strong> zone 3<br />

1 2 1 pe<br />

zijn toepasbaar <strong>op</strong> <strong>de</strong> zone 4<br />

On<strong>de</strong>rste dakrand<br />

e<br />

e1/10 1 /10<br />

≥ e e2/4 2 /4<br />

e Nok<br />

2/4 2/4<br />

e e1/4 1/4<br />

e e2/10 2/10<br />

3 5 6<br />

2<br />

1<br />

e 1/10 1/10<br />

8<br />

b2/2<br />

7<br />

6<br />

7<br />

e 1 /10<br />

e 1 /10<br />

3. e 2 /2 = b 1 /2 omdat in <strong>de</strong> zone 10 rekening gehou<strong>de</strong>n werd met <strong>de</strong> c pe -waar<strong>de</strong>n <strong>van</strong> <strong>de</strong> zone I 90° <strong>van</strong> <strong>de</strong><br />

windrichting θ = 90°(+) en met <strong>de</strong>ze <strong>van</strong> <strong>de</strong> zone H 90° <strong>van</strong> <strong>de</strong> windrichting θ = 90°.<br />

b b1/2 1/2<br />

Tabel 10 Zones <strong>van</strong> cpe afhankelijk <strong>van</strong> <strong>de</strong> zones <strong>van</strong> een dak met twee dakschil<strong>de</strong>n.<br />

Zones Wind θ = 0° Wind θ = 90° Wind θ = 180° Wind θ = 90° (+)<br />

1 G0 H90 I180 I90<br />

2 F0 H90 I180 I90<br />

3 F0 F90 I180 I90<br />

4 H0 F90 I180 I90<br />

5 H0 G90 I180 I90<br />

6 H0 G90 J180 I90<br />

7 H0 H90 J180 I90<br />

8 H0 H90 I180 I90<br />

Door <strong>de</strong> integratie <strong>van</strong> <strong>de</strong> vier windrichtingen verkrijgt men <strong>de</strong> grafieken uit<br />

afbeelding 32, waarin men naargelang <strong>van</strong> <strong>de</strong> dakhelling voor elke zone uit<br />

afbeelding 31, <strong>de</strong> positieve en negatieve waar<strong>de</strong>n <strong>van</strong> <strong>de</strong> buitendrukcoëfficiënten<br />

terugvindt voor <strong>de</strong> belastings<strong>op</strong>pervlakken A <strong>van</strong> 1 m² (cpe,1) en <strong>van</strong> 10 m² (cpe,10).<br />

Voor tussenliggen<strong>de</strong> waar<strong>de</strong>n voor <strong>op</strong>pervlak A verwijzen we naar afbeelding 19. In<br />

bijlage 4 zijn <strong>de</strong> <strong>de</strong>tails <strong>van</strong> <strong>de</strong> berekeningen <strong>op</strong>genomen.<br />

48


c pe<br />

Dubbel afhellen<strong>de</strong> daken c pe,10 , c pe,1 - Zone 1<br />

Dubbel afhellen<strong>de</strong> daken c pe,10 , c pe,1 - Zone 2<br />

Twee dakschil<strong>de</strong>n – cpe,10-cpe,1 – Zone 1 Twee dakschil<strong>de</strong>n – cpe,10-cpe,1 – Zone 2<br />

0,8<br />

0,6<br />

0,4<br />

0,2<br />

Cpe,10<br />

Cpe,1<br />

Cpe,10<br />

Cpe,1<br />

0,8<br />

0,6<br />

0,4<br />

0,2<br />

0<br />

Cpe,10<br />

Cpe,1<br />

Cpe,10<br />

Cpe,1<br />

0<br />

-0,2 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

-45 -40 -35 -30 -25 -20 -15 -10 -5<br />

-0,2<br />

-0,4<br />

-0,6<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

Dakhelling θ°<br />

-0,4<br />

-0,6<br />

-0,8<br />

-1<br />

Dakhelling θ°<br />

-0,8<br />

-1,2<br />

-1<br />

-1,4<br />

-1,6<br />

-1,2<br />

-1,8<br />

-1,4<br />

-2<br />

-1,6<br />

-2,2<br />

-2,4<br />

-1,8<br />

-2,6<br />

-2<br />

-2,8<br />

Dubbel afhellen<strong>de</strong> daken c pe,10 , c pe,1 - Zone 3<br />

Twee dakschil<strong>de</strong>n – cpe,10-cpe,1 – Zone 3<br />

Dubbel afhellen<strong>de</strong> daken c pe,10 , c pe,1 - Zone 4<br />

Twee dakschil<strong>de</strong>n – cpe,10-cpe,1 – Zone 4<br />

0,8<br />

0,6<br />

0,4<br />

0,2<br />

0<br />

Cpe,10<br />

Cpe,1<br />

Cpe,10<br />

Cpe,1<br />

0,9<br />

0,7<br />

0,5<br />

0,3<br />

0,1<br />

Cpe,10<br />

Cpe,1<br />

Cpe,10<br />

Cpe,1<br />

-0,2 -45 -40 -35 -30 -25 -20 -15 -10 -5<br />

-0,4<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 -0,1<br />

-45 -40 -35 -30 -25 -20 -15 -10 -5<br />

-0,3<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

-0,6<br />

-0,8<br />

Dakhelling θ°<br />

-0,5<br />

-0,7<br />

Dakhelling θ°<br />

-1<br />

-0,9<br />

-1,2<br />

-1,1<br />

-1,4<br />

-1,3<br />

-1,6<br />

-1,5<br />

-1,8<br />

-1,7<br />

-2<br />

-1,9<br />

-2,2<br />

-2,1<br />

-2,4<br />

-2,3<br />

-2,6<br />

-2,8<br />

-2,5<br />

c pe<br />

c pe<br />

Dubbel Twee afhellen<strong>de</strong> dakschil<strong>de</strong>n daken – cpe,10-cpe,1 c pe,10 , c pe,1 - – Zone Zone 5 5<br />

Dubbel<br />

Twee<br />

afhellen<strong>de</strong><br />

dakschil<strong>de</strong>n<br />

daken c– cpe,10-cpe,1<br />

pe,10 , c pe,1 - Zone<br />

– Zone<br />

6<br />

6<br />

0,9<br />

0,7<br />

Cpe,10<br />

Cpe,1<br />

1<br />

0,8<br />

Cpe,10<br />

Cpe,1<br />

0,5<br />

Cpe,10<br />

0,6<br />

Cpe,10<br />

0,3<br />

Cpe,1<br />

0,4<br />

Cpe,1<br />

0,1<br />

0,2<br />

-0,1 -45 -40 -35 -30 -25 -20 -15 -10 -5<br />

-0,3<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

0<br />

-0,2 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

-0,5<br />

-0,7<br />

-0,9<br />

-1,1<br />

-1,3<br />

Dakhelling θ° -0,4<br />

-0,6<br />

-0,8<br />

-1<br />

-1,2<br />

-1,4<br />

Dakhelling θ°<br />

-1,5<br />

-1,6<br />

-1,7<br />

-1,8<br />

-1,9<br />

-2<br />

-2,1<br />

-2,2<br />

1,1<br />

0,9<br />

0,7<br />

0,5<br />

0,3<br />

-1,1<br />

-1,3<br />

-1,5<br />

c pe<br />

Dubbel afhellen<strong>de</strong> daken c pe,10 , c pe,1 - Zone 7<br />

Twee dakschil<strong>de</strong>n – cpe,10-cpe,1 – Zone 7<br />

Cpe,10<br />

Cpe,1<br />

Cpe,10<br />

Cpe,1<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

-1<br />

-1,2<br />

-1,4<br />

c pe<br />

c pe<br />

c pe<br />

Twee Dubbel dakschil<strong>de</strong>n afhellen<strong>de</strong> daken – cpe,10-cpe,1<br />

c pe,10 , c pe,1 – Zone - Zone 8<br />

0,1<br />

0<br />

-0,1 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

-45 -40 -35 -30 -25 -20 -15 -10 -5<br />

-0,2<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

-0,3<br />

-0,5<br />

Dakhelling θ° -0,4<br />

Dakhelling θ°<br />

-0,7<br />

-0,6<br />

-0,9<br />

-0,8<br />

Afbeelding 32 Positieve en negatieve waar<strong>de</strong>n <strong>van</strong> <strong>de</strong> buitendrukcoëfficiënten voor <strong>de</strong><br />

belastings<strong>op</strong>pervlakken A <strong>van</strong> 1 m² (cpe,1) en <strong>van</strong> 10 m² (cpe,10) – Krommen voor <strong>de</strong> vier<br />

windrichtingen.<br />

0,8<br />

0,6<br />

0,4<br />

0,2<br />

c pe<br />

Cpe,10<br />

Cpe,1<br />

Cpe,10<br />

Cpe,1<br />

49


Voor <strong>de</strong> hellingshoeken -5° < θ < +5° doet men geen beroep <strong>op</strong> <strong>de</strong> grafieken uit afbeelding 32,<br />

maar wel <strong>op</strong> <strong>de</strong> gegevens over dakterassen, ge<strong>de</strong>finieerd in § 7.2.3 <strong>van</strong> <strong>de</strong> norm EN 1991-1-4.<br />

Indien <strong>de</strong> helling θ = -5°, dient men daarentegen rekening te hou<strong>de</strong>n met een positieve waar<strong>de</strong><br />

<strong>van</strong> cpe,10 = cpe,1 = +0,2.<br />

4.1.2.5.3. Waar<strong>de</strong>n voor <strong>de</strong> binnendrukcoëfficiënt cpi<br />

4.1.2.5.3.1. Druk uitgeoefend <strong>op</strong> enkelwandige muren en daken<br />

Men dient er<strong>van</strong> uit te gaan dat <strong>de</strong> binnendruk en <strong>de</strong> buitendruk gelijktijdig uitgeoefend wor<strong>de</strong>n.<br />

Voor elke combinatie <strong>van</strong> mogelijke <strong>op</strong>eningen (en an<strong>de</strong>re oorzaken <strong>van</strong> luchtlekken) moet <strong>de</strong><br />

meest ongunstige drukcombinatie beschouwd wor<strong>de</strong>n.<br />

Geval <strong>van</strong> ‘sluitbare’ gevel<strong>op</strong>eningen<br />

Deze regel is <strong>van</strong> toepassing <strong>op</strong> <strong>het</strong> meren<strong>de</strong>el <strong>de</strong>r gevallen. Wanneer <strong>het</strong> onmogelijk blijkt of<br />

niet gerechtvaardigd is om <strong>de</strong> permeabiliteitscoëfficënt μ te evalueren (zie § 4.1.2.5.3.2) voor<br />

een specifiek geval – bijvoorbeeld indien er onzekerheid bestaat over <strong>het</strong> feit of <strong>de</strong><br />

gevel<strong>op</strong>eningen (<strong>de</strong>uren, vensters, …) <strong>op</strong>en of gesloten zijn –, dient men aan cpi <strong>de</strong> meest<br />

ongunstige waar<strong>de</strong> <strong>van</strong> +0,2 en -0,3 toe te kennen.<br />

Tabel 11 Waar<strong>de</strong>n voor <strong>de</strong> binnendrukcoëfficiënt cpi.<br />

cpi overdruk cpi on<strong>de</strong>rdruk<br />

+0,2 -0,3<br />

Geval <strong>van</strong> gevel<strong>op</strong>eningen in <strong>op</strong>en toestand bij normale werking<br />

In <strong>het</strong> geval <strong>van</strong> gevel<strong>op</strong>eningen die tij<strong>de</strong>ns <strong>het</strong> gebruik <strong>op</strong>en kunnen blijven, is <strong>de</strong><br />

binnendrukcoëfficiënt cpi afhankelijk <strong>van</strong> <strong>de</strong> afmetingen <strong>van</strong> <strong>de</strong> gevel<strong>op</strong>eningen en <strong>de</strong> ver<strong>de</strong>ling<br />

er<strong>van</strong> in <strong>de</strong> gebouwschil.<br />

Beperking : wanneer <strong>het</strong> totale <strong>op</strong>pervlak <strong>van</strong> <strong>de</strong> verschillen<strong>de</strong> <strong>op</strong>eningen in minstens twee<br />

zij<strong>de</strong>n <strong>van</strong> <strong>het</strong> gebouw (gevels of dak) 30 % <strong>van</strong> <strong>het</strong> <strong>op</strong>pervlak <strong>van</strong> <strong>de</strong>ze zij<strong>de</strong>n<br />

vertegenwoordigt, dient men <strong>de</strong> <strong>op</strong> <strong>de</strong> constructie uitgeoefen<strong>de</strong> belastingen niet te berekenen aan<br />

<strong>de</strong> hand <strong>van</strong> <strong>de</strong> regels uit <strong>de</strong>ze paragraaf, maar is <strong>het</strong> aanbevolen om <strong>de</strong> regels voor alleenstaan<strong>de</strong><br />

constructies te gebruiken, ge<strong>de</strong>finieerd in <strong>de</strong> §§ 7.3 en 7.4. <strong>van</strong> <strong>de</strong> norm NBN EN 1991-1-4.<br />

Deze situaties wor<strong>de</strong>n niet behan<strong>de</strong>ld in dit Rapport.<br />

Nota 18 : als men <strong>het</strong> heeft over <strong>de</strong> <strong>op</strong>eningen <strong>van</strong> een gebouw dient men niet alleen <strong>de</strong> kleine<br />

gevel<strong>op</strong>eningen in <strong>op</strong>en toestand, <strong>de</strong> <strong>op</strong>engaan<strong>de</strong> vleugels, <strong>de</strong> schoorstenen, … te beschouwen,<br />

maar ook <strong>de</strong> intrinsieke permeabiliteit, zoals <strong>de</strong> luchtlekken rondom <strong>de</strong> <strong>de</strong>uren, vensters en<br />

technische installaties, en <strong>de</strong> lekken doorheen <strong>de</strong> gebouwschil. De intrinsieke permeabiliteit<br />

schommelt doorgaans tussen 0,01 % en 0,1 % <strong>van</strong> <strong>het</strong> gevel<strong>op</strong>pervlak.<br />

Een zij<strong>de</strong> <strong>van</strong> een gebouw wordt doorgaans als dominant beschouwd wanneer <strong>de</strong> <strong>op</strong>pervlakte<br />

<strong>van</strong> <strong>de</strong> <strong>op</strong>eningen in <strong>de</strong>ze zij<strong>de</strong> minstens gelijk is aan <strong>het</strong> dubbel <strong>van</strong> <strong>de</strong> <strong>op</strong>pervlakte <strong>van</strong> <strong>de</strong><br />

<strong>op</strong>ningen en <strong>de</strong> luchtlekken in <strong>de</strong> an<strong>de</strong>re zij<strong>de</strong>n <strong>van</strong> <strong>het</strong> gebouw.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

50


In <strong>het</strong> geval <strong>van</strong> een gebouw met een dominante zij<strong>de</strong> dient men <strong>de</strong> binnendruk te beschouwen<br />

als een fractie <strong>van</strong> <strong>de</strong> buitendruk ter hoogte <strong>van</strong> <strong>de</strong> <strong>op</strong>eningen in <strong>de</strong> dominante zij<strong>de</strong> en <strong>de</strong><br />

waar<strong>de</strong>n te gebruiken die gegeven wor<strong>de</strong>n door <strong>de</strong> hierna vermel<strong>de</strong> uitdrukkingen (a) en (b) :<br />

− wanneer <strong>de</strong> <strong>op</strong>pervlakte <strong>van</strong> <strong>de</strong> <strong>op</strong>eningen in <strong>de</strong> dominante zij<strong>de</strong> gelijk is aan <strong>het</strong> dubbel <strong>van</strong><br />

<strong>de</strong> <strong>op</strong>pervlakte <strong>van</strong> <strong>de</strong> <strong>op</strong>eningen in <strong>de</strong> an<strong>de</strong>re zij<strong>de</strong>n : cpi = 0,75 . cpe (a)<br />

− wanneer <strong>de</strong> <strong>op</strong>pervlakte <strong>van</strong> <strong>de</strong> <strong>op</strong>eningen in <strong>de</strong> dominante zij<strong>de</strong> minstens gelijk is aan <strong>het</strong><br />

drievoud <strong>van</strong> <strong>de</strong> <strong>op</strong>pervlakte <strong>van</strong> <strong>de</strong> <strong>op</strong>eningen in <strong>de</strong> an<strong>de</strong>re zij<strong>de</strong>n : cpi = 0,90 . cpe (b)<br />

waarbij cpe <strong>de</strong> waar<strong>de</strong> <strong>van</strong> <strong>de</strong> buitendrukcoëfficiënt ter hoogte <strong>van</strong> <strong>de</strong> <strong>op</strong>eningen in <strong>de</strong> dominante<br />

zij<strong>de</strong> voorstelt.<br />

Wanneer <strong>de</strong>ze <strong>op</strong>eningen zich bevin<strong>de</strong>n in zones waar een verschillen<strong>de</strong> buitendruk heerst, is <strong>het</strong><br />

aanbevolen om een gemid<strong>de</strong>l<strong>de</strong> <strong>op</strong>pervlaktegewogen cpe-waar<strong>de</strong> te gebruiken.<br />

Als <strong>de</strong> <strong>op</strong>pervlakte <strong>van</strong> <strong>de</strong> <strong>op</strong>eningen in <strong>de</strong> dominante zij<strong>de</strong> 2 tot 3 keer groter is dan <strong>de</strong><br />

<strong>op</strong>pervlakte <strong>van</strong> <strong>de</strong> <strong>op</strong>eningen in <strong>de</strong> an<strong>de</strong>re zij<strong>de</strong>n, kan men voor <strong>de</strong> bepaling <strong>van</strong> cpi overgaan<br />

tot een lineaire interpolatie tussen (a) en (b).<br />

Voor gebouwen zon<strong>de</strong>r dominante zij<strong>de</strong> dient men <strong>de</strong> binnendrukcoëfficiënt cpi te bepalen aan<br />

<strong>de</strong> hand <strong>van</strong> afbeelding 33. De coëfficiënt cpi is immers afhankelijk <strong>van</strong> <strong>de</strong> verhouding tussen <strong>de</strong><br />

hoogte en <strong>de</strong> diepte <strong>van</strong> <strong>het</strong> gebouw (h/d) en <strong>van</strong> <strong>de</strong> permeabiliteitscoëfficiënt μ voor elke<br />

windrichting θ. De permeabiliteitscoëfficiënt μ wordt bepaald met behulp <strong>van</strong> <strong>de</strong> volgen<strong>de</strong><br />

uitdrukking :<br />

<strong>de</strong><strong>op</strong>pervlakte<strong>van</strong><strong>de</strong><strong>op</strong>eningen waarvoor cpe negatief isof gelijk isaan0<br />

μ=<br />

<strong>de</strong><strong>op</strong>pervlakte<strong>van</strong> alle <strong>op</strong>eningen<br />

∑<br />

∑<br />

Nota 19 : voor <strong>de</strong> waar<strong>de</strong>n tussen h/d = 0,25 en h/d = 1,0 mag een lineaire interpolatie<br />

wor<strong>de</strong>n toegepast.<br />

c pi<br />

0,4<br />

0,35<br />

0,3<br />

0,25<br />

0,2<br />

0,15<br />

0,1<br />

0,05<br />

0,33<br />

0<br />

μ<br />

-0,05 0,3 0,35<br />

-0,1<br />

-0,15<br />

0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9 0,95 1<br />

-0,2<br />

-0,25<br />

-0,3<br />

-0,35<br />

-0,4<br />

-0,45<br />

-0,5<br />

_ _ c cpi (h/d 0,25)<br />

pi (h/d ≤ 0,25)<br />

___ c cpi (h/d>1,0)<br />

pi (h/d > 1,0)<br />

-0,55 0,33<br />

Afbeelding 33 Binnendrukcoëfficiënten <strong>van</strong> toepassing <strong>op</strong> gelijkmatig ver<strong>de</strong>el<strong>de</strong> <strong>op</strong>eningen.<br />

Nota 20 : dit diagram is <strong>van</strong> toepassing <strong>op</strong> gevels en <strong>op</strong> daken <strong>van</strong> gebouwen met of zon<strong>de</strong>r<br />

binnenwan<strong>de</strong>n.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

51


Referentiehoogte zi<br />

De referentiehoogte zi die gebruikt moet wor<strong>de</strong>n voor <strong>de</strong> binnendrukken is gelijk aan <strong>de</strong><br />

referentiehoogte ze voor <strong>de</strong> buitendrukken die uitgeoefend wor<strong>de</strong>n <strong>op</strong> <strong>de</strong> zij<strong>de</strong>n die, gelet <strong>op</strong> hun<br />

<strong>op</strong>eningen, bijdragen tot <strong>het</strong> ontstaan <strong>van</strong> <strong>de</strong> binnendruk. Indien er meer<strong>de</strong>re <strong>op</strong>eningen<br />

aanwezig zijn, is <strong>het</strong> aangera<strong>de</strong>n om <strong>de</strong> grootste waar<strong>de</strong> <strong>van</strong> ze te gebruiken ter bepaling <strong>van</strong> zi.<br />

Als vereenvoudig<strong>de</strong> hypothese wordt er in <strong>de</strong> formules ter bepaling <strong>van</strong> <strong>de</strong> rekenwaar<strong>de</strong>n voor<br />

<strong>de</strong> belastingen <strong>van</strong> uitgegaan dat <strong>de</strong> referentiehoogte voor <strong>de</strong> binnendruk zi gelijk is aan <strong>de</strong><br />

referentiehoogte voor <strong>de</strong> buitendruk ze (zie § 4.6).<br />

Nota 21 : toevallige (acci<strong>de</strong>ntele) situaties<br />

Wanneer een buiten<strong>op</strong>ening, zoals een <strong>de</strong>ur of een venster, dominant is in ge<strong>op</strong>en<strong>de</strong> toestand<br />

(bv. als men <strong>de</strong>ze vergeet te sluiten), maar in <strong>de</strong> uiterste grenstoestand (bv. bij hevige wind) als<br />

gesloten wordt beschouwd, dient men <strong>de</strong> situatie met <strong>de</strong> <strong>de</strong>ur of <strong>het</strong> venster in ge<strong>op</strong>en<strong>de</strong><br />

toestand als een toevallige (acci<strong>de</strong>ntele) <strong>ontwerp</strong>situatie te beschouwen, overeenkomstig <strong>de</strong> norm<br />

EN 1990. Dergelijke toevallige (acci<strong>de</strong>ntele) situaties komen in dit document niet aan bod.<br />

Nota 22 : <strong>de</strong> controle <strong>van</strong> <strong>de</strong> toevallige (acci<strong>de</strong>ntele) <strong>ontwerp</strong>situatie is erg belangrijk voor hoge<br />

binnenwan<strong>de</strong>n (met een groot risico <strong>op</strong> gevaar), die weerstand moeten bie<strong>de</strong>n aan <strong>de</strong> volledige<br />

externe windbelasting, vermits er <strong>op</strong>eningen aanwezig zijn in <strong>de</strong> gebouwschil.<br />

4.1.2.5.3.2. Druk uitgeoefend <strong>op</strong> meerwandige muren en daken<br />

De uitgeoefen<strong>de</strong> winddruk moet voor elke wand (of gebouwschil) afzon<strong>de</strong>rlijk berekend<br />

wor<strong>de</strong>n.<br />

De permeabiliteit μ <strong>van</strong> een wand wordt ge<strong>de</strong>finieerd als <strong>de</strong> verhouding tussen <strong>de</strong> totale<br />

<strong>op</strong>pervlakte <strong>van</strong> <strong>de</strong> luchtlekken en <strong>de</strong> totale wand<strong>op</strong>pervlakte. Een wand wordt als<br />

ondoordringbaar beschouwd als <strong>de</strong> waar<strong>de</strong> <strong>van</strong> µ kleiner is dan 0,1 %.<br />

Wanneer één enkele wand permeabel (luchtdoorlaatbaar) blijkt te zijn, dient men <strong>de</strong> winddruk<br />

<strong>op</strong> <strong>de</strong> ondoordringbare wand te bepalen aan <strong>de</strong> hand <strong>van</strong> <strong>het</strong> verschil tussen <strong>de</strong> binnendruk en <strong>de</strong><br />

buitendruk <strong>van</strong> <strong>de</strong> wind, zoals voorgestel in afbeelding 34.<br />

Wind (+) (-)<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

W We1 e1<br />

Afbeelding 34 Winddruk <strong>op</strong> een <strong>op</strong>pervlak.<br />

De nettodruk die <strong>op</strong> een muur, een dak of een element wordt uitgeoefend, is gelijk aan <strong>het</strong> verschil<br />

tussen <strong>de</strong> drukken die <strong>op</strong> <strong>de</strong> tegenoverliggen<strong>de</strong> <strong>op</strong>pervlakken wor<strong>de</strong>n uitgeoefend, rekening hou<strong>de</strong>nd<br />

met hun tekens. Een druk, uitgeoefend in <strong>de</strong> richting <strong>van</strong> <strong>het</strong> <strong>op</strong>pervlak, wordt beschouwd als positief,<br />

terwijl een on<strong>de</strong>rdruk die zich <strong>van</strong> <strong>het</strong> <strong>op</strong>pervlak verwij<strong>de</strong>rt, beschouwd wordt als negatief.<br />

W We2 e2<br />

52


Wanneer minstens twee wan<strong>de</strong>n permeabel (luchtdoorlaatbaar) blijken te zijn, zal <strong>de</strong> windruk <strong>op</strong><br />

elke wand afhankelijk zijn <strong>van</strong> :<br />

• <strong>de</strong> relatieve stijfheid <strong>van</strong> <strong>de</strong> wan<strong>de</strong>n<br />

• <strong>de</strong> binnen- en <strong>de</strong> buitendruk<br />

• <strong>de</strong> afstand tussen <strong>de</strong> wan<strong>de</strong>n<br />

• <strong>de</strong> permeabiliteit (doorlaatbaarheid) <strong>van</strong> <strong>de</strong> wan<strong>de</strong>n<br />

• <strong>de</strong> <strong>op</strong>eningen aan <strong>de</strong> omtrek <strong>van</strong> <strong>de</strong> luchtspouw tussen <strong>de</strong> wan<strong>de</strong>n.<br />

Nota 23 : <strong>het</strong> is raadzaam om <strong>de</strong> winddruk <strong>op</strong> <strong>de</strong> stijfste wand gelijk te stellen aan <strong>het</strong> verschil<br />

tussen <strong>de</strong> binnen- en <strong>de</strong> buitendruk.<br />

Indien <strong>de</strong> omtrek <strong>van</strong> <strong>de</strong> luchtspouw tussen <strong>de</strong> wan<strong>de</strong>n luchtdicht is (afbeelding 35 (a)) en <strong>de</strong><br />

vrije afstand tussen <strong>de</strong> wan<strong>de</strong>n kleiner is dan 100 mm (bij een volledige afwezigheid <strong>van</strong><br />

luchtcirculatie in <strong>het</strong> warmte-isolatiemateriaal, mag dit materiaal beschouwd wor<strong>de</strong>n als een<br />

on<strong>de</strong>r<strong>de</strong>el <strong>van</strong> één <strong>van</strong> <strong>de</strong> wan<strong>de</strong>n), mogen <strong>de</strong> volgen<strong>de</strong> regels wor<strong>de</strong>n toegepast als eerste<br />

bena<strong>de</strong>ring :<br />

• voor muren en daken met een ondoordringbare binnenwand (gebouwschil) en een permeabele<br />

(luchtdoorlaatbare) buitenwand waar<strong>van</strong> <strong>de</strong> permeabiliteit nagenoeg gelijkmatig ver<strong>de</strong>eld is,<br />

kan <strong>de</strong> winddruk <strong>op</strong> <strong>de</strong> buitenwand berekend wor<strong>de</strong>n aan <strong>de</strong> hand <strong>van</strong> cp,net = 2/3 . cpe (voor<br />

overdrukken) en <strong>van</strong> cp,net = 1/3 . cpe (voor on<strong>de</strong>rdrukken). De winddruk <strong>op</strong> <strong>de</strong> binnenwand<br />

kan berekend wor<strong>de</strong>n aan <strong>de</strong> hand <strong>van</strong> cp,net = cpe – cpi<br />

• voor muren en daken met een ondoordringbare binnenwand en een eveneens<br />

ondoordringbare, doch stijvere buitenwand, kan <strong>de</strong> winddruk <strong>op</strong> <strong>de</strong> buitenwand berekend<br />

wor<strong>de</strong>n aan <strong>de</strong> hand <strong>van</strong> cp,net = cpe – cpi<br />

• voor muren en daken met een permeabele (luchtdoorlaatbare) binnenwand waar<strong>van</strong> <strong>de</strong><br />

permeabiliteit nagenoeg gelijkmatig ver<strong>de</strong>eld is en een ondoordringbare buitenwand, kan <strong>de</strong><br />

winddruk <strong>op</strong> <strong>de</strong> buitenwand berekend wor<strong>de</strong>n aan <strong>de</strong> hand <strong>van</strong> cp,net = cpe – cpi, terwijl <strong>de</strong><br />

winddruk <strong>op</strong> <strong>de</strong> binnenwand berekend wordt aan <strong>de</strong> hand <strong>van</strong> cp,net = 1/3 . cpi<br />

• voor muren en daken met een ondoordringbare buitenwand en een eveneens ondoordringbare,<br />

doch stijvere binnenwand, kan <strong>de</strong> winddruk <strong>op</strong> <strong>de</strong> buitenwand berekend wor<strong>de</strong>n aan <strong>de</strong> hand<br />

<strong>van</strong> cp,net = cpe, terwijl <strong>de</strong> winddruk <strong>op</strong> <strong>de</strong> binnenwand berekend wordt aan <strong>de</strong> hand <strong>van</strong> cp,net =<br />

cpe – cpi.<br />

Bovenstaan<strong>de</strong> regels zijn niet <strong>van</strong> toepassing in aanwezigheid <strong>van</strong> luchttoevoer<strong>op</strong>eningen die <strong>de</strong><br />

spouw verbin<strong>de</strong>n met een an<strong>de</strong>re zij<strong>de</strong> <strong>van</strong> <strong>het</strong> gebouw dan <strong>de</strong>ze waarin <strong>de</strong> gevel zich bevindt<br />

(afbeelding 35 (b)).<br />

(a)<br />

(b)<br />

(a) Omtrek <strong>van</strong> <strong>de</strong> luchtspouw tussen gesloten wan<strong>de</strong>n<br />

(b) Omtrek <strong>van</strong> <strong>de</strong> luchtspouw tussen <strong>op</strong>en wan<strong>de</strong>n<br />

Afbeelding 35 Details <strong>van</strong> <strong>de</strong> hoeken <strong>van</strong> meerwandige buitenmuren.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

53


4.1.2.5.4. Specifiek geval <strong>van</strong> kleine constructies in reliëf <strong>op</strong> gevels of daken<br />

Elementen die voornamelijk vlak zijn (luifels, borstweringen, …)<br />

De cp-coëfficiënten die men in aanmerking dient te nemen voor elementen in reliëf <strong>op</strong> een gevel<br />

of een dak (vrijstaan<strong>de</strong> muren, luifels, <strong>op</strong>stan<strong>de</strong>n) zijn weergegeven in afbeelding 36<br />

(dakterassen wor<strong>de</strong>n in dit document niet behan<strong>de</strong>ld).<br />

Voor <strong>de</strong> luifels die in <strong>het</strong> dakvlak gelegen zijn en voor <strong>de</strong> <strong>op</strong>stan<strong>de</strong>n moet er langs <strong>de</strong> hoekzones<br />

(afbeelding 25, afbeelding 29 - zones F) een drukcoëfficënt cf gehanteerd wor<strong>de</strong>n, die gelijk is<br />

aan <strong>het</strong> verschil tussen <strong>de</strong> coëfficiënt cpe die overeenkomt met zone F uit tabel 7 of tabel 9 en <strong>de</strong><br />

coëfficiënt cpe die overeenkomt met zone D uit tabel 4.<br />

Op elementen met een <strong>op</strong>pervlakte kleiner dan 10 m² zijn <strong>de</strong> overige hoofdstukken <strong>van</strong><br />

toepassing.<br />

Wind<br />

Wind<br />

Afbeelding 36 cp-coëfficiënten <strong>van</strong> elementen in reliëf <strong>op</strong> constructies.<br />

Volumes (veranda’s, glazen daken, …)<br />

Wind<br />

Indien <strong>het</strong> volume slechts een <strong>de</strong>el <strong>van</strong> <strong>de</strong> gevel inneemt (zie afbeelding 37), is <strong>de</strong> volgen<strong>de</strong><br />

regel <strong>van</strong> toepassing :<br />

• A <strong>de</strong> kleinste waar<strong>de</strong> <strong>van</strong> h, b1, b2<br />

• B <strong>de</strong> grootste waar<strong>de</strong> <strong>van</strong> c, d1, d2<br />

• X <strong>de</strong> kleinste waar<strong>de</strong> <strong>van</strong> x1, x2.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

54


Als B ≤ 0,5 A en X ≥ 0,25 A, maakt <strong>de</strong> veranda <strong>de</strong>el uit <strong>van</strong> <strong>de</strong> gevel waaraan <strong>de</strong>ze is<br />

vastgemaakt (zelf<strong>de</strong> cpe als <strong>de</strong> gevel). In <strong>de</strong> an<strong>de</strong>re gevallen wordt <strong>de</strong>ze beschouwd als een<br />

vrijstaan<strong>de</strong> constructie en zijn <strong>de</strong> cpe voor daken <strong>van</strong> toepassing.<br />

Afbeelding 37 Volumes die slechts een <strong>de</strong>el <strong>van</strong> <strong>de</strong> gevel of <strong>het</strong> dak innemen.<br />

Indien <strong>het</strong> volume slechts een <strong>de</strong>el <strong>van</strong> <strong>het</strong> dak inneemt (zie afbeelding 37), mogen voor <strong>het</strong><br />

glazen dak <strong>de</strong> volgen<strong>de</strong> zones buiten beschouwing gelaten wor<strong>de</strong>n :<br />

1. <strong>de</strong> hoekzones (F : zie afbeelding 25 of afbeelding 29; zones 3 en 7 : zie afbeelding 27;<br />

zones 3 en 6 : afbeelding 31) :<br />

a. indien <strong>de</strong> hoek <strong>van</strong> <strong>het</strong> glazen dak minstens met <strong>de</strong> in afbeelding 37 aangegeven waar<strong>de</strong>n<br />

(e1/8 en e2/8) <strong>van</strong> <strong>de</strong> overeenkomstige hoek <strong>van</strong> <strong>het</strong> dak verwij<strong>de</strong>rd is 4<br />

b. indien <strong>de</strong> hoogte <strong>van</strong> <strong>de</strong> hoekzone <strong>van</strong> <strong>het</strong> glazen dak ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong> hoek <strong>van</strong> <strong>het</strong> dak<br />

kleiner is dan 0,1 keer <strong>de</strong> hoogte <strong>van</strong> <strong>de</strong> overeenkomstige hoek<br />

2. <strong>de</strong> randzones (G : zie afbeelding 25 of afbeelding 29; zones 1, 2, 8 en 9 : zie afbeelding 27;<br />

zones 1, 2 en 7 : zie afbeelding 31) indien <strong>de</strong> twee hoekzones (zie 1. hierboven) die grenzen<br />

aan <strong>de</strong> dakrand niet in aanmerking genomen wor<strong>de</strong>n.<br />

4.2. Belasting veroorzaakt door <strong>het</strong> eigengewicht<br />

De bepaling <strong>van</strong> <strong>het</strong> eigengewicht geschiedt door <strong>het</strong> raadplegen <strong>van</strong> <strong>de</strong> catalogi <strong>van</strong> <strong>de</strong><br />

producenten waarin <strong>de</strong> geometrische karakteristieken en <strong>het</strong> gewicht <strong>van</strong> <strong>de</strong> bestand<strong>de</strong>len <strong>van</strong><br />

<strong>het</strong> bouwwerk <strong>op</strong>genomen zijn. Men kan hiertoe tevens gebruik maken <strong>van</strong> <strong>de</strong> waar<strong>de</strong>n uit <strong>de</strong><br />

norm NBN EN 1991-1-1:2002 ‘Euroco<strong>de</strong> 1. Belastingen <strong>op</strong> constructies. Deel 1-1 : Algemene<br />

belastingen – Volumieke gewichten, eigengewicht, <strong>op</strong>geleg<strong>de</strong> belastingen voor gebouwen’<br />

(gehomologeer<strong>de</strong> versie + Nationale Bijlage).<br />

4 Ter herinnering : e1 = minimale waar<strong>de</strong> <strong>van</strong> b1 en 2h; e2 = minimale waar<strong>de</strong> <strong>van</strong> b2 en 2h.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

55


Tabel 12 Waar<strong>de</strong>n voor <strong>het</strong> eigengewicht.<br />

Materialen Volumieke massa ρ [kg/m 3 ]<br />

Staal 7800<br />

Aluminium 2700<br />

Hout (NBN EN 338) (gemid<strong>de</strong>l<strong>de</strong> waar<strong>de</strong>n)<br />

Sterkteklasse<br />

C14 350<br />

C16 370<br />

C18 380<br />

C22 410<br />

C24 420<br />

C27 450<br />

C30 460<br />

C35 480<br />

C40 500<br />

C50 550<br />

D30 640<br />

D40 700<br />

D60 840<br />

Kunststoffen<br />

Acrylplaten 1200<br />

Polystyreen (geëxpan<strong>de</strong>erd of in korrels) 25<br />

PVC 700<br />

Schuimisolatieplaten 30-40<br />

Vensterglas 2500<br />

Houten platen<br />

Multiplex<br />

ruw multiplex (naaldhout en berk) 600<br />

gelamineer<strong>de</strong> plaat en meubelplaat met<br />

staafjesbinnenlaag<br />

400<br />

Spaanplaten 800<br />

Cementgebon<strong>de</strong>n spaanplaten<br />

Vezelplaten voor gebouwen<br />

1200<br />

hardboard 1000<br />

medium hardboard 800<br />

isolatieplaten (met vezels) 400<br />

Uitdrukking <strong>van</strong> <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht<br />

Gewoonlijk wordt <strong>het</strong> eigengewicht gk uitgedrukt als <strong>de</strong> som <strong>van</strong> <strong>de</strong> elementen die een druk<br />

uitoefenen <strong>op</strong> <strong>het</strong> te berekenen element :<br />

gk = Σi ρi Vi<br />

waarbij ρi = <strong>het</strong> volumieke gewicht <strong>van</strong> <strong>het</strong> element i<br />

Vi = <strong>het</strong> volume <strong>van</strong> <strong>het</strong> element i.<br />

Deze belasting kan zowel een puntlast als een lineaire belasting zijn.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

56


4.3. Belasting veroorzaakt door sneeuw<br />

Sneeuw kan zich <strong>op</strong> verschillen<strong>de</strong> manieren <strong>op</strong> een dak afzetten, al naargelang <strong>van</strong> <strong>de</strong> vorm <strong>van</strong><br />

<strong>het</strong> dak, zijn thermische eigenschappen, <strong>de</strong> ruwheid <strong>van</strong> zijn <strong>op</strong>pervlak, <strong>de</strong> hoeveelheid warmte<br />

die on<strong>de</strong>r <strong>het</strong> dak <strong>op</strong>gewekt wordt, <strong>de</strong> aanwezigheid <strong>van</strong> gebouwen in <strong>de</strong> omgeving, <strong>de</strong><br />

kenmerken <strong>van</strong> <strong>het</strong> omliggen<strong>de</strong> terrein en <strong>de</strong> plaatselijke weersomstandighe<strong>de</strong>n, in <strong>het</strong> bijzon<strong>de</strong>r<br />

<strong>de</strong> windsnelhe<strong>de</strong>n, <strong>de</strong> temperatuurschommelingen en <strong>de</strong> neerslagfrequentie (regen of sneeuw).<br />

De afzetting <strong>van</strong> sneeuw kan bovendien <strong>het</strong> resultaat zijn <strong>van</strong> een <strong>op</strong>h<strong>op</strong>ing uit verschillen<strong>de</strong><br />

richtingen of <strong>van</strong> één of meer<strong>de</strong>re sneeuwbuien tij<strong>de</strong>ns eenzelf<strong>de</strong> klimaatgebeurtenis.<br />

De bepaling <strong>van</strong> <strong>de</strong> sneeuwbelasting gebeurt volgens <strong>de</strong> norm NBN EN 1991-1-3 ‘Belastingen<br />

<strong>op</strong> constructies. Sneeuwbelasting’ (gehomologeer<strong>de</strong> versie + Nationale Bijlage) (zie eveneens<br />

<strong>het</strong> artikel «Een nieuwe norm ter bepaling <strong>van</strong> <strong>de</strong> sneeuwbelasting» verschenen in <strong>de</strong> WTCB-<br />

Dossiers, Katern nr. 6, 2 e trimester 2005). Gewoonlijk neemt men bij <strong>de</strong>ze bepaling <strong>de</strong><br />

gelijkmatig ver<strong>de</strong>el<strong>de</strong> sneeuwlaag, <strong>op</strong>geho<strong>op</strong>t tij<strong>de</strong>ns een natuurlijke sneeuwbui bij kalm weer in<br />

aanmerking, alsook <strong>de</strong> vorm <strong>van</strong> <strong>het</strong> dak en <strong>de</strong> ver<strong>de</strong>ling <strong>van</strong> <strong>de</strong> sneeuw als gevolg <strong>van</strong> <strong>de</strong> wind.<br />

Deze specificaties zijn <strong>van</strong> toepassing voor <strong>de</strong> hellen<strong>de</strong> wan<strong>de</strong>n <strong>van</strong> daken met één of twee<br />

dakschil<strong>de</strong>n, die gekenmerkt zijn door dui<strong>de</strong>lijke on<strong>de</strong>rbrekingen. Voor an<strong>de</strong>re situaties<br />

verwijzen we naar <strong>de</strong> norm NBN EN 1991-1-3.<br />

De sneeuwbelasting wordt algemeen uitgedrukt door <strong>de</strong> volgen<strong>de</strong> vergelijking :<br />

s = rsk . μi . ce . ct . sk, waarbij :<br />

− sk <strong>de</strong> karakteristieke sneeuwbelasting per m² <strong>op</strong> <strong>het</strong> maaiveld voorstelt, zoals weergegeven<br />

in tabel 13 en in afbeelding 38<br />

− µ een vormcoëfficiënt voor <strong>de</strong> sneeuwbelasting voorstelt, die afhangt <strong>van</strong> <strong>de</strong> vorm <strong>van</strong> <strong>de</strong><br />

beschouw<strong>de</strong> wand. Over <strong>het</strong> algemeen kunnen er twee fundamentele belastingssituaties<br />

geï<strong>de</strong>ntificeerd wor<strong>de</strong>n voor <strong>de</strong> bepaling <strong>van</strong> <strong>de</strong> coëfficiënten :<br />

1. <strong>de</strong>ze <strong>van</strong> een gelijkmatig ver<strong>de</strong>el<strong>de</strong> sneeuwbelasting over <strong>het</strong> volledige dak, die enkel<br />

beïnvloed wordt door <strong>de</strong> vorm <strong>van</strong> <strong>het</strong> dak, vóór <strong>de</strong> herver<strong>de</strong>ling <strong>van</strong> <strong>de</strong> belasting<br />

tengevolge <strong>van</strong> an<strong>de</strong>re weersinvloe<strong>de</strong>n. Deze situatie is waarschijnlijk tij<strong>de</strong>ns sneeuwval<br />

bij matige wind<br />

2. <strong>de</strong>ze <strong>van</strong> een ongelijkmatig ver<strong>de</strong>el<strong>de</strong> sneeuwbelasting, die <strong>het</strong> resultaat is <strong>van</strong> een<br />

herver<strong>de</strong>ling <strong>van</strong> <strong>de</strong> sneeuw <strong>van</strong> <strong>de</strong> ene plaats naar een an<strong>de</strong>re <strong>op</strong> <strong>het</strong> dak, bijvoorbeeld als<br />

gevolg <strong>van</strong> <strong>de</strong> wind.<br />

In afbeelding 39 zijn <strong>de</strong> waar<strong>de</strong>n voor <strong>de</strong> vormcoëfficiënten voor <strong>de</strong> sneeuwbelasting<br />

samengevat<br />

− ce en ct respectievelijk <strong>de</strong> blootstellingscoëfficiënt en <strong>de</strong> thermische coëfficiënt voorstellen<br />

(waar<strong>van</strong> <strong>het</strong> product gewoonlijk gelijkgesteld wordt aan 1); zie <strong>de</strong> norm NBN EN 1991-1-3<br />

− rsk <strong>de</strong> terugkeerperio<strong>de</strong> voor <strong>de</strong> sneeuw voorstelt<br />

Voor <strong>de</strong> hoofdconstructie, <strong>de</strong> verankeringen en <strong>de</strong> secundaire constructies werd een<br />

terugkeerperio<strong>de</strong> <strong>van</strong> 50 jaar (rsk = 1) als referentie genomen. Voor <strong>de</strong> niet-structurele<br />

elementen werd <strong>de</strong> terugkeerperio<strong>de</strong> aangepast. Volgens <strong>de</strong> specificaties <strong>van</strong> <strong>de</strong> norm NBN<br />

EN 1991-1-3 (Bijlage D) en <strong>de</strong> Belgische Bijlage kan <strong>de</strong> terugkeercoëfficiënt <strong>van</strong> <strong>de</strong> sneeuw<br />

als volgt uitgedrukt wor<strong>de</strong>n :<br />

6<br />

1−<br />

V × × [ ln( −ln(<br />

1−<br />

1/<br />

n))<br />

+ 057722]<br />

sn<br />

rsk<br />

= = π , waarbij :<br />

sk<br />

1+<br />

2,<br />

5923×<br />

V<br />

− sn : <strong>de</strong> sneeuwbelasting <strong>op</strong> <strong>de</strong> grond die overeenkomt met een terugkeerperio<strong>de</strong> <strong>van</strong> n jaar<br />

− n : <strong>het</strong> aantal jaren<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

57


− V : <strong>de</strong> variatiecoëfficiënt <strong>van</strong> <strong>de</strong> jaarlijkse maximale sneeuwbelasting. Volgens <strong>de</strong><br />

Belgische Bijlage NBN EN 1991-1-3 ANB heeft <strong>de</strong>ze een waar<strong>de</strong> <strong>van</strong> :<br />

V = ( 1,<br />

01+<br />

0,<br />

00248×<br />

A)<br />

/( 1+<br />

0,<br />

00614×<br />

A)<br />

, waarbij A <strong>de</strong> hoogte (in meter) voorstelt.<br />

Tabel 13 Sneeuwbelasting.<br />

Sneeuwbelasting sk [kN/m²] Hoogte [m]<br />

sk = 0,5 A ≤ 100<br />

sk = 0,5 + 0,007(A-100)/6 100 ≤ A ≤ 700<br />

A(m)<br />

μ<br />

700<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

0,9<br />

0,8<br />

0,7<br />

0,6<br />

0,5<br />

0,4<br />

0,3<br />

0,2<br />

0,1<br />

0<br />

1<br />

1,7<br />

1,6<br />

1,5<br />

1,4<br />

1,3<br />

1,2<br />

1,1<br />

0<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

s k<br />

0,4 0,5 0,6 0,7 0,8 0,9 1 1,1 1,2<br />

S k (KN/m²)<br />

Afbeelding 38 Sneeuwbelasting.<br />

Coefficients Vormcoëfficiënt <strong>de</strong> forme<br />

0 10 20 30 40 50 60 70<br />

Pente Dakhelling <strong>de</strong> toiture α°<br />

Afbeelding 39 Vormcoëfficiënten voor <strong>de</strong> sneeuwbelastingen – Hellen<strong>de</strong> daken.<br />

Tabel 14 Vormcoëfficiënten – Daken met één dakschild.<br />

Hoek <strong>van</strong> <strong>het</strong> dakschild ten <strong>op</strong>zichte<br />

<strong>van</strong> <strong>de</strong> horizontale<br />

0° ≤ α ≤ 30° 30° < α < 60° α ≥ 60°<br />

Vormcoëfficiënt μ1 0,8 0,8 (60 - α)/30 0,0<br />

Vormcoëfficiënt μ2 0,8 + 0,8 α/30 1,6 –<br />

4.3.1. Daken met één dakschild<br />

De vormcoëfficiënten voor <strong>de</strong> sneeuwbelasting μ1 die gebruikt zou<strong>de</strong>n moeten wor<strong>de</strong>n voor<br />

daken met één dakschild zijn <strong>op</strong>genomen in tabel 14 en afbeelding 39 voor <strong>het</strong> geval waarbij <strong>de</strong><br />

sneeuw ongehin<strong>de</strong>rd <strong>van</strong> <strong>de</strong> dakrand kan vallen. Wanneer <strong>het</strong> dak uitgerust is met voorzieningen<br />

μ 2<br />

μ 1<br />

μ1<br />

μ2<br />

sk<br />

58


die <strong>de</strong> sneeuw kunnen tegenhou<strong>de</strong>n of wanneer <strong>de</strong> on<strong>de</strong>rrand eidigt tegen een borstwering, een<br />

sneeuwbarrière of een<strong>de</strong>r welk an<strong>de</strong>r obstakel, mag <strong>de</strong> vormcoëfficiënt niet wor<strong>de</strong>n beperkt tot<br />

een waar<strong>de</strong> die kleiner is dan 0,8. De te beschouwen schikking <strong>van</strong> <strong>de</strong> belasting is weergegeven<br />

in afbeelding 40.<br />

Afbeelding 40 Vormcoëfficiënten – Daken met één enkel dakschild.<br />

4.3.2. Daken met twee dakschil<strong>de</strong>n<br />

De te beschouwen belastingen voor daken met twee dakschil<strong>de</strong>n zijn weergegeven in<br />

afbeelding 41; <strong>de</strong> μ1-waar<strong>de</strong>n zijn <strong>op</strong>genomen in tabel 14 en voorgesteld in afbeelding 39.<br />

De vormcoëfficiënten voor <strong>de</strong> sneeuwbelasting uit tabel 14 en afbeelding 39 gel<strong>de</strong>n voor <strong>het</strong><br />

geval waarbij <strong>de</strong> sneeuw ongehin<strong>de</strong>rd <strong>van</strong> <strong>de</strong> dakrand kan vallen. Wanneer <strong>het</strong> dak uitgerust is<br />

met uitrustingen die <strong>de</strong> sneeuw kunnen tegenhou<strong>de</strong>n of wanneer <strong>de</strong> on<strong>de</strong>rrand eindigt tegen een<br />

borstwering, een sneeuwbarrière of een<strong>de</strong>r welk an<strong>de</strong>r obstakel, mag <strong>de</strong> vormcoëfficiënt niet<br />

wor<strong>de</strong>n beperkt tot een waar<strong>de</strong> die kleiner is dan 0,8.<br />

Afbeelding 41 Vormcoëfficiënten – Daken met twee dakschil<strong>de</strong>n.<br />

Wanneer <strong>de</strong> sneeuwbelasting gelijkmatig ver<strong>de</strong>eld is, is <strong>het</strong> geval (i) <strong>van</strong> toepassing.<br />

Wanneer <strong>de</strong> sneeuwbelasting ongelijkmatig ver<strong>de</strong>eld is, zijn <strong>de</strong> gevallen (ii) en (iii) <strong>van</strong> toepassing.<br />

4.3.3. Daken tegen een grote <strong>op</strong>gaan<strong>de</strong> constructie<br />

De coëfficiënten voor <strong>de</strong> sneeuwbelasting die gebruikt zou<strong>de</strong>n moeten wor<strong>de</strong>n voor een dak<br />

tegen een grote <strong>op</strong>gaan<strong>de</strong> constructie kunnen ge<strong>de</strong>finieerd wor<strong>de</strong>n als volgt :<br />

− μ1 = 0,8 (in <strong>de</strong> veron<strong>de</strong>rstelling <strong>van</strong> een lager gelegen plat dak)<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

59


− μ2 = μs + μw, waarbij :<br />

- μs <strong>de</strong> vormcoëfficiënt <strong>van</strong> <strong>de</strong> sneeuwbelasting tengevolge <strong>van</strong> <strong>de</strong> afglijding <strong>van</strong> sneeuw<br />

<strong>van</strong> <strong>het</strong> bovenste dak voorstelt. Voor α < 15° is μs gelijk aan 0; voor α > 15° wordt μs<br />

bepaald door <strong>de</strong> toepassing <strong>van</strong> een bijkomen<strong>de</strong> belasting die gelijk is aan 50 % <strong>van</strong> <strong>de</strong><br />

maximale sneeuwbelasting die aangrijpt <strong>op</strong> <strong>het</strong> dakschild dat aan <strong>het</strong> bovenste dak grenst<br />

en berekend wordt volgens <strong>de</strong> voorgaan<strong>de</strong> paragrafen<br />

- μw <strong>de</strong> vormcoëfficiënt voor <strong>de</strong> sneeuwbelasting tengevolge <strong>van</strong> <strong>de</strong> wind voorstelt :<br />

μw = (b1 + b2)/2h ≤ γh/sk<br />

met <strong>de</strong> beperking 0,8 ≤ μ w ≤ 2<br />

en waarbij γ <strong>het</strong> volumieke gewicht <strong>van</strong> <strong>de</strong> sneeuw voorstelt, dat in <strong>de</strong>ze berekening<br />

gelijkgesteld mag wor<strong>de</strong>n aan 2 kN/m³<br />

− <strong>de</strong> lengte <strong>van</strong> <strong>de</strong> sneeuwho<strong>op</strong> is begrensd tot ls = 2h, met <strong>de</strong> beperking 5 m ≤ ls ≤ 15 m.<br />

Nota 24 : indien b 2 < l s moet <strong>de</strong> coëfficiënt aan <strong>de</strong> rand <strong>van</strong> <strong>het</strong> on<strong>de</strong>rste dak bepaald wor<strong>de</strong>n<br />

door interpolatie tussen µ 1 en µ 2 , en moet <strong>de</strong> grens <strong>van</strong> <strong>de</strong> sneeuwbelasting ingekort wor<strong>de</strong>n tot<br />

aan <strong>de</strong> grens <strong>van</strong> <strong>het</strong> on<strong>de</strong>rste dak (b 2 ).<br />

(i)<br />

(ii)<br />

µ2<br />

b1<br />

µs<br />

µw<br />

α<br />

ls<br />

b2<br />

µ1<br />

µ1<br />

h<br />

Afbeelding 42 Vormcoëffciënten indien er uitgesproken niveauverschillen zijn.<br />

Wanneer <strong>de</strong> sneeuwbelasting gelijkmatig ver<strong>de</strong>eld is, is geval (i) <strong>van</strong> toepassing.<br />

Wanneer <strong>de</strong> sneeuwbelasting ongelijkmatig ver<strong>de</strong>eld is, is geval (ii) <strong>van</strong> toepassing.<br />

Nota 25 : wij willen er<strong>op</strong> wijzen dat <strong>de</strong> µ-coëfficiënten geen rekening hou<strong>de</strong>n met <strong>de</strong> effecten<br />

<strong>van</strong> een impact <strong>van</strong> een grote hoeveelheid sneeuw, afkomstig <strong>van</strong> <strong>het</strong> bovenste dak, vermits <strong>de</strong>ze<br />

situatie uitzon<strong>de</strong>rlijk is. Doorgaans valt <strong>de</strong> sneeuw gelei<strong>de</strong>lijk en met kleine hoeveelhe<strong>de</strong>n <strong>van</strong> <strong>het</strong><br />

bovenste dak naar bene<strong>de</strong>n naarmate <strong>het</strong> sneeuwtapijt <strong>van</strong> <strong>het</strong> dak schuift en zijn <strong>de</strong> effecten<br />

<strong>van</strong> <strong>de</strong>ze impact gering in vergelijking tot <strong>de</strong> totale statische rekenbelasting. Dit geldt <strong>de</strong>s te meer<br />

indien <strong>het</strong> dak uitgerust is met bakgoten of met sneeuwbarrières.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

µ2<br />

(i)<br />

(ii)<br />

b1<br />

µs<br />

µw<br />

α<br />

b2<br />

ls<br />

b2 (


4.4. Belastingen veroorzaakt door <strong>de</strong> borstweringsfunctie<br />

4.4.1. Inleiding<br />

De borstweringsfunctie is ge<strong>de</strong>finieerd in § 2.2.8. De productnormen voor gordijngevels en<br />

vensters, met name <strong>de</strong> NBN EN 13830 en <strong>de</strong> NBN EN 13451-1, bevatten slechts weinig<br />

informatie over <strong>de</strong> borstweringsfunctie in een gevel. Ondanks <strong>het</strong> feit dat <strong>de</strong>ze normen voor <strong>de</strong><br />

belastingen naar <strong>de</strong> Euroco<strong>de</strong>s verwijzen, specificeren ze geen enkele coëfficiënt, noch<br />

criterium. De Euroco<strong>de</strong>s verwijzen dan weer naar <strong>de</strong> Nationale Bijlagen, die bepaal<strong>de</strong><br />

beoor<strong>de</strong>lingsparameters <strong>de</strong>finiëren en <strong>de</strong> geïnteresseer<strong>de</strong> lezer ver<strong>de</strong>r doorverwijzen naar <strong>de</strong><br />

bijzon<strong>de</strong>re specificaties voor <strong>de</strong> beschouw<strong>de</strong> producten (STS, NBN, …).<br />

Om een ein<strong>de</strong> te maken aan <strong>de</strong>ze verwarren<strong>de</strong> situatie heeft dit document zich tot doel gesteld<br />

om <strong>de</strong> bestaan<strong>de</strong> eisen samen te vatten en aanbevelingen te formuleren voor <strong>de</strong> beoor<strong>de</strong>ling <strong>van</strong><br />

gevels die volgens <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n een borstweringsfunctie moeten vervullen.<br />

4.4.2. Beoor<strong>de</strong>lingsparameters<br />

4.4.2.1. Beschermingshoogte (H)<br />

De beschermingshoogte H is <strong>de</strong> hoogte waarover <strong>de</strong> borstweringsfunctie in al zijn pertinente<br />

aspecten moet wor<strong>de</strong>n verzekerd naargelang <strong>van</strong> <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n. De hoogte H wordt<br />

ge<strong>de</strong>finieerd ten aanzien <strong>van</strong> <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n (zie § 4.4.2.6). Deze is begrepen tussen<br />

0,9 en 1,2 m, maar kan wor<strong>de</strong>n beperkt tot 0,80 m indien voldaan wordt aan <strong>de</strong> berekening <strong>van</strong><br />

een fictieve hoogte Hf = h + 0,5 x l ≥ 1,0 m, waarbij l <strong>de</strong> dikte <strong>van</strong> <strong>de</strong> gevel ter hoogte <strong>van</strong> <strong>de</strong><br />

beschermingshoogte H voorstelt, zoals aangegeven in <strong>de</strong> afbeeldingen.<br />

4.4.2.2. Valhoogte (hc)<br />

De valhoogte hc is <strong>de</strong> hoogte <strong>van</strong>af <strong>het</strong> niveau <strong>van</strong> <strong>de</strong> vloer on<strong>de</strong>raan tot <strong>het</strong> hoogste niveau <strong>van</strong><br />

<strong>het</strong> vaste ka<strong>de</strong>r (zie afbeeldingen hierna).<br />

4.4.2.3. Referentiehoogte voor <strong>de</strong> beschermingshoogte (h)<br />

In norm NBN B 25-002-1 wordt <strong>de</strong> referentiehoogte voor <strong>de</strong> beschermingshoogte h ge<strong>de</strong>finieerd<br />

als <strong>de</strong> hoogte langs <strong>de</strong> risicozij<strong>de</strong> tussen <strong>van</strong> <strong>het</strong> niveau <strong>van</strong> <strong>de</strong> afgewerkte bo<strong>de</strong>m en <strong>het</strong> hoogste<br />

niveau <strong>van</strong> <strong>het</strong> vaste ka<strong>de</strong>r <strong>van</strong> <strong>het</strong> schrijnwerk (dwarsregel).<br />

4.4.2.4. Toegankelijkheid <strong>van</strong> <strong>de</strong> gevel<br />

De twee zij<strong>de</strong>n <strong>van</strong> <strong>de</strong> gevel, d.w.z. zowel langs binnen als langs buiten, kunnen toegankelijk<br />

zijn. Volgens <strong>de</strong> norm NBN B 25-002-1 dient men plaatsen die rechtstreeks toegankelijk zijn<br />

voor <strong>het</strong> publiek als volgt te on<strong>de</strong>rschei<strong>de</strong>n <strong>van</strong> plaatsen die niet rechtstreeks toegankelijk zijn<br />

voor <strong>het</strong> publiek :<br />

- publiek toegankelijke plaatsen zijn plaatsen waar zich een groot en onbepaald aantal personen<br />

kan <strong>op</strong>hou<strong>de</strong>n : trottoirs, aangeleg<strong>de</strong> pa<strong>de</strong>n, speelplaatsen, ingangen <strong>van</strong> gebouwen die<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

61


uitgeven <strong>op</strong> <strong>de</strong> <strong>op</strong>enbare weg, terrassen en commercieel uitgebate horecaruimten, voor <strong>het</strong><br />

publiek toegankelijke tuinen en parken, …<br />

- plaatsen die niet rechtstreeks toegankelijk zijn voor <strong>het</strong> publiek zijn plaatsen waar slechts<br />

een beperkt en geautoriseerd aantal personen is toegestaan : terrassen en niet-commercieel<br />

uitgebate ruimten, niet voor <strong>het</strong> publiek toegankelijke tuinen en parken, interne ingangen.<br />

De menselijke activiteitenzones wor<strong>de</strong>n in <strong>de</strong> norm NBN S 23-002 als volgt inge<strong>de</strong>eld :<br />

− publiek toegankelijke plaatsen<br />

− <strong>de</strong> gebruikscategorieën A tot E voor gebouwen.<br />

Dit Rapport raadt aan om <strong>de</strong> belastingswaar<strong>de</strong>n te on<strong>de</strong>rschei<strong>de</strong>n die ge<strong>de</strong>finieerd wor<strong>de</strong>n in<br />

tabel 15. De dynamische en statische belastingen zijn slechts <strong>van</strong> toepassing <strong>op</strong> <strong>de</strong> toegankelijke<br />

zij<strong>de</strong>(n) <strong>van</strong> <strong>de</strong> gevel.<br />

Nota 26 : wanneer <strong>de</strong> gevel naast <strong>de</strong> borstweringsfunctie nog een bijkomen<strong>de</strong><br />

beveiligingsfunctie dient te vervullen (bv. bescherming tegen projectielen, neervallen<strong>de</strong><br />

voorwerpen, …) moeten er bijkomen<strong>de</strong> eisen geformuleerd wor<strong>de</strong>n, naargelang <strong>van</strong> <strong>het</strong> te<br />

verzekeren veiligheidsniveau. De meeste afbeeldingen uit § 4.4 illustreren <strong>de</strong> situatie waarbij <strong>het</strong><br />

buitenniveau lager ligt dan <strong>het</strong> binnenniveau (dit geval komt <strong>het</strong> meest voor). Wanneer dit niet zo<br />

is, bv. in <strong>het</strong> geval weergegeven in afbeelding 43, zijn <strong>de</strong> hierna beschreven regels <strong>van</strong><br />

toepassing, die tot doel hebben <strong>de</strong> personen te beschermen tegen verwondingen of tegen <strong>het</strong><br />

risico om <strong>van</strong> buiten naar binnen te vallen.<br />

4.4.2.5. Belastingen <strong>op</strong> een gevel die een borstweringsfunctie vervult<br />

4.4.2.5.1. Statische veran<strong>de</strong>rlijke belastingen<br />

4.4.2.5.1.1. Rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> statische belastingen<br />

Statische belastingen kunnen omschreven wor<strong>de</strong>n als <strong>het</strong> (al dan niet aanzienlijke) gedrum <strong>van</strong><br />

een bewegen<strong>de</strong> mensenmassa dat geen aanleiding geeft tot schokken, maar wel tot een druk <strong>op</strong><br />

<strong>de</strong> bescherming. Deze belastingen zijn genormaliseerd in <strong>de</strong> Euroco<strong>de</strong> NBN EN 1991-1-1<br />

(§ 6.4), die <strong>de</strong>ze beschouwt als horizontale belastingen qk <strong>op</strong> borstweringen en voor <strong>het</strong><br />

preciseren <strong>van</strong> <strong>de</strong> bijkomen<strong>de</strong> belastingen verwijst naar <strong>de</strong> <strong>ontwerp</strong>norm prNBN B 03-004<br />

‘Borstweringen’ (in voorbereiding), vermits <strong>de</strong>ze <strong>de</strong> bijkomen<strong>de</strong> verticale belastingen <strong>de</strong>finieert.<br />

Men kan vier belastingen on<strong>de</strong>rschei<strong>de</strong>n, die weergegeven wor<strong>de</strong>n door <strong>het</strong> symbool Ab om ze<br />

niet te verwarren met an<strong>de</strong>re belastingen (afbeelding 43) :<br />

− drie horizontale belastingen Ah :<br />

1. qk,h : een lineaire horizontale kracht die gelijkmatig <strong>op</strong> <strong>de</strong> gevelstructuur (dwarsregel)<br />

wordt uitgeoefend ter hoogte <strong>van</strong> <strong>de</strong> beschermingshoogte H, gelegen tussen 800 en 1200<br />

mm <strong>van</strong> <strong>de</strong> afgewerkte vloer, of bij gebrek aan een structuur, tussen 800 en 1200 mm <strong>van</strong><br />

<strong>de</strong> afgewerkte vloer <strong>op</strong> <strong>het</strong> vulelement <strong>op</strong> <strong>de</strong> meest ongunstige hoogte. In <strong>het</strong> laatste<br />

geval (vulelement) dient men <strong>de</strong> kracht te laten aangrijpen over een breedte <strong>van</strong> 100 mm<br />

2. Qkh,1 : een geconcentreer<strong>de</strong> horizontale kracht voor <strong>de</strong> plaatselijke controle ter hoogte<br />

<strong>van</strong> <strong>de</strong> beschermingshoogte H, die wordt uitgeoefend <strong>op</strong> een vierkant <strong>op</strong>pervlak (100 mm<br />

x 100 mm) <strong>op</strong> <strong>de</strong> meest ongunstige plaats<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

62


3. Qkh,2 : een geconcentreer<strong>de</strong> horizontale kracht voor <strong>de</strong> plaatselijke controle on<strong>de</strong>r <strong>de</strong><br />

beschermingshoogte H, die wordt uitgeoefend <strong>op</strong> een vierkant <strong>op</strong>pervlak (100 mm x<br />

100 mm) <strong>op</strong> <strong>de</strong> meest ongunstige plaats<br />

− één verticale belasting :<br />

4. Qkv,3 : een verticale belasting die wordt uitgeoefend <strong>op</strong> <strong>de</strong> dwarsregel die dienst doet als<br />

leuning <strong>op</strong> <strong>de</strong> meest ongunstige plaats.<br />

De aanbevolen waar<strong>de</strong>n voor <strong>de</strong> belastingen zijn <strong>op</strong>gegeven in tabel 15 naargelang <strong>van</strong> <strong>het</strong><br />

specifieke gebruik <strong>van</strong> <strong>het</strong> gebouw. Het gaat hier om <strong>de</strong> brutowaar<strong>de</strong>n. De nettowaar<strong>de</strong>n wor<strong>de</strong>n<br />

verkregen door vermenigvuldiging met <strong>de</strong> begelei<strong>de</strong>n<strong>de</strong> coëfficiënten en <strong>de</strong> partiële<br />

coëfficiënten uit <strong>de</strong> tabellen <strong>van</strong> § 4.6. De veran<strong>de</strong>rlijke belastingen Ab moeten onafhankelijk<br />

<strong>van</strong> elkaar beschouwd wor<strong>de</strong>n.<br />

Tabel 15 Belastingen voor <strong>de</strong> borstweringsfunctie.<br />

Gebruikscategorieën<br />

(EN 1991-1-1)<br />

A Huishou<strong>de</strong>lijke en resi<strong>de</strong>ntiële activiteiten<br />

Eengezinswoningen en appartementen<br />

Vertrekken <strong>van</strong> woongebouwen en huizen; kamers en<br />

zalen <strong>van</strong> ziekenhuizen; kamers <strong>van</strong> hotels en tehuizen;<br />

keukens en toiletten, …<br />

Lineaire<br />

belasting<br />

en qk,h<br />

(kN/m)<br />

Q k,h1 <strong>op</strong> <strong>de</strong><br />

beschermings-<br />

hoogte<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

Puntbelastingen (kN)<br />

Q k,h2 on<strong>de</strong>r <strong>de</strong><br />

beschermings-<br />

hoogte<br />

Q kv,3 <strong>op</strong> <strong>de</strong><br />

beschermings-<br />

hoogte<br />

0,5 1,0 0,5 1,0<br />

B Kantoren 1,0 1,0 0,5 1,0<br />

C Plaatsen waar veel mensen samenkomen (<strong>de</strong><br />

<strong>op</strong>pervlakken <strong>van</strong> <strong>de</strong> categorieën A, B, D en E<br />

uitgezon<strong>de</strong>rd)<br />

C1 : plaatsen met tafels, … (bv. scholen, cafés,<br />

1,0 1,0 0,5 1,0<br />

restaurants, feestzalen, leeszalen, receptiezalen, …)<br />

C2 : plaatsen met vaste stoelen (bv. kerken, theaters en<br />

biosc<strong>op</strong>en, conferentiezalen, amfitheaters,<br />

verga<strong>de</strong>rzalen, wachtzalen, …)<br />

C3 : plaatsen zon<strong>de</strong>r obstakels voor <strong>het</strong> personenverkeer<br />

(bv. musea, tentoonstellingszalen, … en ingangen <strong>van</strong><br />

<strong>op</strong>enbare en administratieve gebouwen, hotels, …)<br />

C4 : plaatsen waar fysieke activiteiten mogelijk zijn (bv.<br />

discotheken, turnzalen, toneelzalen, …)<br />

C5 : plaatsen waar een grote mensenmassa kan<br />

samenkomen (bv. gebouwen waar <strong>op</strong>enbare<br />

evenementen kunnen plaatsgrijpen, zoals concertzalen,<br />

sportzalen met inbegrip <strong>van</strong> <strong>de</strong> tribunes, terrassen en<br />

toegangszones, …). Horizontale afstand tussen <strong>de</strong><br />

borstwering, <strong>de</strong> stoelenrijen of <strong>de</strong> afscheidingen (*) :<br />

3 m<br />

2 m<br />

D Han<strong>de</strong>ls<strong>op</strong>pervlakken<br />

D1 : <strong>de</strong>tailhan<strong>de</strong>lsruimten (bv. magazijnen,<br />

papierhan<strong>de</strong>ls, winkels <strong>van</strong> kantoormaterialen, …)<br />

1,0 1,0 0,5 1,0<br />

1,0 1,0 0,5 1,0<br />

1,0 1,0 0,5 1,0<br />

5,0<br />

3,0<br />

2,0<br />

2,0<br />

0,5<br />

0,5<br />

63<br />

1,0<br />

1,0<br />

1,0 1,0 0,5 1,0<br />

E Oppervlakken die zich lenen voor <strong>de</strong> <strong>op</strong>slag <strong>van</strong> grote<br />

volumes goe<strong>de</strong>ren, toegangszones inbegrepen<br />

(bv. <strong>op</strong>slagruimten, met inbegrip <strong>van</strong> bibliotheken)<br />

2,0 1,0 0,5 1,0<br />

Publiek toegankelijke plaatsen buiten (zie § 4.4.2.4). 1,0 1,0 0,5 1,0<br />

(*) Overeenkomstig <strong>het</strong> KB <strong>van</strong> 2 juni 1999 hou<strong>de</strong>n<strong>de</strong> <strong>de</strong> in voetbalstadions na te leven veiligheidsnormen (BS <strong>van</strong> 10 juli 1999).


4.4.2.5.1.2. Controle <strong>van</strong> <strong>de</strong> statische belastingen door proeven<br />

Wanneer <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n zodanig zijn dat er geen berekening kan uitgevoerd wor<strong>de</strong>n<br />

(bv. als gevolg <strong>van</strong> <strong>de</strong> materiaaleigenschappen, <strong>de</strong> assemblagetechnieken, …) of dat <strong>de</strong>ze geen<br />

bevredigen<strong>de</strong> controle <strong>op</strong>levert, moet <strong>de</strong> stabiliteit on<strong>de</strong>r statische belasting wor<strong>de</strong>n nagegaan<br />

aan <strong>de</strong> hand <strong>van</strong> proeven volgens <strong>de</strong> <strong>ontwerp</strong>norm prNBN B 03-004 ‘Borstweringen’ (in<br />

voorbereiding), rekening hou<strong>de</strong>nd met <strong>de</strong> ligging <strong>van</strong> <strong>de</strong> gevel.<br />

4.4.2.5.2. Dynamische belastingen<br />

De controle on<strong>de</strong>r dynamische belastingen gebeurt door mid<strong>de</strong>l <strong>van</strong> schokproeven volgens <strong>de</strong><br />

norm NBN B 25-002-1 (§ 5.2.2.10.2 of § 5.2.3.10.2) naargelang <strong>van</strong> <strong>de</strong> <strong>ontwerp</strong>situatie. De<br />

plaatsen waar <strong>de</strong> schokken uitgeoefend wor<strong>de</strong>n, zijn weerggeven in § 4.4.2.5.4.<br />

Afbeelding 43 Voorbeeld <strong>van</strong> <strong>de</strong> controle <strong>van</strong> <strong>de</strong> borstweringsfunctie in een gevel.<br />

Nota 27 : <strong>de</strong> norm NBN EN 13049 (Ramen. Botsing met een zacht en zwaar lichaam) stelt <strong>de</strong><br />

aangrijpingspunten voor <strong>de</strong> schokken voor. Ze preciseert echter ook dat men één prototype per<br />

aangrijpingspunt mag gebruiken.<br />

Nota 28 : § 5 <strong>van</strong> <strong>de</strong> norm NBN EN 14019 (Gordijnmuren. Weerstand tegen stootbelasting)<br />

stelt <strong>de</strong> aangrijpingspunten voor <strong>de</strong> schokken voor. De voorschriften uit § 4.4.2.5.4 <strong>van</strong> dit<br />

document kunnen een alternatief vormen.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

64


4.4.2.5.3. Vereenvoudigen<strong>de</strong> aanbevelingen<br />

Statische en dynamische belastingen zijn conventionele belastingen. Om <strong>het</strong> aantal<br />

belastingsgevallen niet no<strong>de</strong>loos te vermenigvuldigen, wor<strong>de</strong>n in <strong>de</strong> volgen<strong>de</strong> paragrafen<br />

conventionele aangrijpingspunten voor <strong>de</strong> belastingen aanbevolen, evenals een<br />

controleprogramma voor schrijnwerkelementen waar<strong>van</strong> mag wor<strong>de</strong>n aangenomen dat zij een<br />

borstweringsfunctie vervullen in <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n.<br />

We willen er<strong>op</strong> wijzen dat <strong>de</strong> kracht Qkv,3 enkel <strong>van</strong> toepassing is voor <strong>op</strong>engaan<strong>de</strong><br />

schrijnwerkelementen indien er een dwarsregel aanwezig is waar<strong>op</strong> <strong>de</strong> verticale belasting kan<br />

aangrijpen. In <strong>de</strong> praktijk zou <strong>het</strong> element waar<strong>op</strong> <strong>de</strong> belasting uitgeoefend wordt een minimale<br />

breedte <strong>van</strong> 100 mm moeten vertonen om in aanmerking te komen.<br />

4.4.2.5.4. Positie <strong>van</strong> <strong>de</strong> statische en dynamische belastingen<br />

Hierna geven wij voor <strong>de</strong> verschillen<strong>de</strong> schrijnwerktypes die geïllustreerd wor<strong>de</strong>n in <strong>de</strong><br />

volgen<strong>de</strong> afbeeldingen een overzicht <strong>van</strong> <strong>de</strong> aangrijpingspunten voor <strong>de</strong> dynamische<br />

(schokenergie) en <strong>de</strong> statische <strong>ontwerp</strong>belastingen. Het spreekt echter voor zich dat al <strong>de</strong>ze<br />

belastingen niet on<strong>de</strong>r alle omstandighe<strong>de</strong>n <strong>van</strong> toepassing zullen zijn. In § 4.4.2.6 wordt<br />

namelijk aanbevolen om <strong>de</strong> belastingen te beschouwen rekening hou<strong>de</strong>nd met welbepaal<strong>de</strong><br />

<strong>ontwerp</strong>situaties.<br />

Ver<strong>de</strong>r willen we er<strong>op</strong> wijzen dat :<br />

• voor vensters enkel <strong>de</strong> aangrijpingspunten <strong>van</strong> <strong>de</strong> dynamische belastingen <strong>op</strong> <strong>de</strong><br />

vulelementen aanbevolen wor<strong>de</strong>n<br />

• voor gordijngevels <strong>de</strong> aanbevolen aangrijpingspunten <strong>van</strong> <strong>de</strong> dynamische belastingen zich <strong>op</strong><br />

<strong>de</strong> vulelementen en <strong>op</strong> <strong>de</strong> weerstandsprofielen bevin<strong>de</strong>n.<br />

De valhoogten <strong>van</strong> <strong>de</strong> impactor zijn vermeld in <strong>de</strong> norm NBN B 25-002-1 (§ 5.2.2.10.2 of<br />

§ 5.2.3.10.2).<br />

De symbolen die gebruikt wor<strong>de</strong>n om <strong>de</strong> belastingen weer te geven, zijn <strong>op</strong>genomen in tabel 16.<br />

Tabel 16 Symbool en voorstelling <strong>van</strong> <strong>de</strong> belastingen Ab.<br />

Symbool Belastingen Ab Voorstelling<br />

Lineaire horizontale kracht <strong>op</strong> <strong>de</strong> beschermingshoogte<br />

Geconcentreer<strong>de</strong> horizontale kracht <strong>op</strong> <strong>de</strong> beschermingshoogte<br />

Geconcentreer<strong>de</strong> kracht on<strong>de</strong>r <strong>de</strong> beschermingshoogte<br />

Verticale belasting <strong>op</strong> <strong>de</strong> dwarsregel <strong>van</strong> een <strong>op</strong>engaan<strong>de</strong> vleugel<br />

– Schokken (<strong>de</strong> valhoogten <strong>van</strong> <strong>de</strong> impactor voor <strong>de</strong> schokproeven<br />

zijn weergegeven in <strong>de</strong> NBN B 25-002-1)<br />

4.4.2.5.4.1. Dwarsregel <strong>op</strong> <strong>de</strong> beschermingshoogte H<br />

Wanneer <strong>de</strong> dwarsregel zich <strong>op</strong> <strong>de</strong> beschermingshoogte bevindt, grijpen <strong>de</strong> belastingen qk,h, Qkh,1<br />

en Qkv,3 aan <strong>op</strong> <strong>de</strong> horizontale dwarsregel. De kracht Qkh,2 grijpt aan in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong><br />

vensterborstwering.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

65


Men beschouwt <strong>de</strong> volgen<strong>de</strong> schokken :<br />

• voor vensters : één enkele schok is aanbevolen, in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> vensterborstwering<br />

• voor gordijngevels : drie schokken zijn aanbevolen : één in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong><br />

vensterborstwering, één in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> dwarsregel <strong>op</strong> <strong>de</strong> beschermingshoogte en één<br />

<strong>op</strong> <strong>de</strong> stijl <strong>op</strong> <strong>de</strong> veiligheidshoogte.<br />

Afbeelding 44 Aangrijpingspunten voor <strong>de</strong> belastingen Ab en voor <strong>de</strong> schokken in geval <strong>van</strong> een<br />

dwarsregel <strong>op</strong> <strong>de</strong> beschermingshoogte H.<br />

4.4.2.5.4.2. Dwarsregel on<strong>de</strong>r <strong>de</strong> beschermingshoogte H<br />

Wanneer <strong>de</strong> dwarsregel zich on<strong>de</strong>r <strong>de</strong> beschermingshoogte bevindt, grijpen <strong>de</strong> belastingen qk,h en<br />

Qkh,1 aan <strong>op</strong> <strong>het</strong> vulpaneel <strong>op</strong> <strong>de</strong> beschermingshoogte H en <strong>de</strong> kracht Qkh,2 in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong><br />

vensterborstwering en <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> dwarsregel.<br />

Men beschouwt <strong>de</strong> volgen<strong>de</strong> schokken :<br />

• voor vensters : twee schokken zijn aanbevolen : één in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> vensterborstwering,<br />

<strong>de</strong> an<strong>de</strong>re in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> breedte <strong>van</strong> <strong>het</strong> vulpaneel <strong>op</strong> <strong>de</strong> beschermingshoogte<br />

• voor gordijngevels : vier schokken zijn aanbevolen : één in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong><br />

vensterborstwering, één in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> dwarsregel on<strong>de</strong>r <strong>de</strong> beschermingshoogte, één<br />

in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> breedte <strong>van</strong> <strong>het</strong> vulpaneel <strong>op</strong> <strong>de</strong> beschermingshoogte en één <strong>op</strong> <strong>de</strong> stijl<br />

<strong>op</strong> <strong>de</strong> beschermingshoogte.<br />

Afbeelding 45 Aangrijpingspunten voor <strong>de</strong> belastingen Ab en voor <strong>de</strong> schokken in geval <strong>van</strong> een<br />

dwarsregel on<strong>de</strong>r <strong>de</strong> beschermingshoogte H.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

66


In <strong>het</strong> geval <strong>van</strong> een <strong>op</strong>engaan<strong>de</strong> vleugel voorziet <strong>de</strong> norm NBN B 25-002-1 :<br />

− ofwel een borstwering die <strong>de</strong> veiligheid tot <strong>op</strong> <strong>de</strong> beschermingshoogte H moet verzekeren<br />

− ofwel een beperking <strong>van</strong> <strong>de</strong> <strong>op</strong>ening met <strong>de</strong> volgen<strong>de</strong> eis :<br />

indien <strong>het</strong> mogelijk is <strong>het</strong> venster slechts ge<strong>de</strong>eltelijk te <strong>op</strong>enen om <strong>het</strong> risico <strong>op</strong> vallen<br />

door <strong>het</strong> venster te voorkomen (bv. <strong>op</strong>eningsbegrenzer), moet <strong>het</strong> schrijnwerk in <strong>op</strong>en<br />

toestand aan <strong>de</strong> schokproeven on<strong>de</strong>rworpen wor<strong>de</strong>n.<br />

We beschouwen <strong>het</strong> specifieke geval, voorgesteld in afbeelding 46 :<br />

− voor <strong>de</strong> borstwering : <strong>de</strong> belastingen qk,h, Qkh,1 en Qkv,3 grijpen aan <strong>op</strong> <strong>de</strong> borstwering <strong>op</strong> <strong>de</strong><br />

beschermingshoogte H; Qkv,2 grijpt aan <strong>op</strong> <strong>het</strong> vulelement<br />

− voor <strong>het</strong> schrijnwerk met <strong>op</strong>engaan<strong>de</strong> vleugel : Qkv,3 grijpt aan <strong>op</strong> <strong>de</strong> dwarsregel en Qkh,2 <strong>op</strong><br />

<strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>het</strong> vulelement en <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> dwarsregel<br />

Men beschouwt <strong>de</strong> volgen<strong>de</strong> schokken :<br />

− voor vensters : twee schokken zijn aanbevolen : één in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong><br />

vensterborstwering en één in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> breedte <strong>van</strong> <strong>de</strong> vleugel <strong>op</strong> <strong>de</strong><br />

beschermingshoogte<br />

− voor gordijngevels : vier schokken zijn aanbevolen : één in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong><br />

vensterborstwering, één in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> dwarsregel on<strong>de</strong>r <strong>de</strong> beschermingshoogte,<br />

één in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> breedte <strong>van</strong> <strong>het</strong> vulpaneel <strong>op</strong> <strong>de</strong> beschermingshoogte en één <strong>op</strong><br />

<strong>de</strong> stijl <strong>op</strong> <strong>de</strong> beschermingshoogte.<br />

Afbeelding 46 Aangrijpingspunten voor <strong>de</strong> belastingen Ab en voor <strong>de</strong> schokken in geval <strong>van</strong> een<br />

dwarsregel on<strong>de</strong>r <strong>de</strong> beschermingshoogte H, met een vensterborstwering en een borstwering.<br />

4.4.2.5.4.3. Geen dwarsregel of dwarsregel boven <strong>de</strong> beschermingshoogte H<br />

Wanneer <strong>de</strong> dwarsregel zich boven <strong>de</strong> beschermingshoogte bevindt, grijpen <strong>de</strong> belastingen qk,h<br />

en Qkh,1 aan <strong>op</strong> <strong>het</strong> vulpaneel <strong>op</strong> <strong>de</strong> beschermingshoogte H en <strong>de</strong> kracht Qkh,2 <strong>op</strong> <strong>de</strong> kleinste<br />

hoogte tussen H en <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> vensterborstwering. Men beschouwt <strong>de</strong> volgen<strong>de</strong><br />

schokken :<br />

• voor vensters : één enkele schok is aanbevolen; <strong>de</strong> gekozen hoogte is <strong>de</strong> kleinste hoogte<br />

tussen H en <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>het</strong> vulpaneel<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

67


• voor gordijngevels : twee schokken zijn aanbevolen : één <strong>op</strong> <strong>de</strong> stijl <strong>op</strong> <strong>de</strong> veiligheidshoogte<br />

en <strong>de</strong> an<strong>de</strong>re <strong>op</strong> <strong>de</strong> kleinste hoogte tussen H en <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>het</strong> vulpaneel.<br />

Afbeelding 47 Aangrijpingspunten voor <strong>de</strong> belastingen Ab en voor <strong>de</strong> schokken in geval <strong>van</strong> een<br />

dwarsregel boven <strong>de</strong> beschermingshoogte H.<br />

4.4.2.6. Controleprogramma, rekening hou<strong>de</strong>nd met <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n<br />

4.4.2.6.1. Algemeenhe<strong>de</strong>n<br />

Nota 29 : gangbaar schrijnwerk is doorgaans niet in staat om <strong>de</strong> belastingen <strong>op</strong> te nemen die<br />

gepaard gaan met een borstweringsfunctie voor <strong>de</strong> specifieke gebruiken C5 en E. Het is dan ook<br />

aangewezen om een borstwering te voorzien die onafhankeijk is <strong>van</strong> <strong>het</strong> schrijnwerk, in<br />

overeenstemming met <strong>de</strong> <strong>ontwerp</strong>norm prNBN B 03-004 (in voorbereiding).<br />

De belangrijkste <strong>ontwerp</strong>parameters voor <strong>het</strong> risico – en dus ook voor <strong>de</strong> keuze <strong>van</strong> <strong>de</strong> prestaties<br />

voor <strong>het</strong> <strong>buitenschrijnwerk</strong> – zijn :<br />

• <strong>de</strong> referentiehoogte voor <strong>de</strong> beschermingshoogte h (zie § 4.4.2.3)<br />

• <strong>de</strong> valhoogte hc (zie § 4.4.2.2)<br />

• <strong>de</strong> aanwezigheid <strong>van</strong> vaste en <strong>op</strong>engaan<strong>de</strong> <strong>de</strong>len<br />

• <strong>de</strong> hoogte he tussen <strong>het</strong> grondniveau buiten en <strong>het</strong> hoogste niveau <strong>van</strong> <strong>het</strong> vaste ka<strong>de</strong>r<br />

(dwarsregel) <strong>van</strong> <strong>het</strong> schrijnwerk. De externe schokproeven zijn slechts <strong>van</strong> toepassing<br />

wanneer he ≤ H<br />

• <strong>de</strong> beschermingshoogte H (zie § 4.4.2.1).<br />

Indien <strong>het</strong> <strong>buitenschrijnwerk</strong> toegankelijk is langs bei<strong>de</strong> zij<strong>de</strong>n (menselijke activiteitenzones aan<br />

weerszij<strong>de</strong>n <strong>van</strong> <strong>het</strong> schrijnwerk) volgens <strong>de</strong> voorwaar<strong>de</strong>n, ge<strong>de</strong>finieerd in § 5.2.2.10.2 of<br />

§ 5.2.3.10.2 <strong>van</strong> NBN B 25-002-1 (h < 0,9 m en/of he < 0,9 m), moeten <strong>de</strong> statische en<br />

dynamische belastingen voor <strong>de</strong> borstweringsfunctie zowel <strong>van</strong> binnen naar buiten als <strong>van</strong><br />

buiten naar binnen wor<strong>de</strong>n uitgeoefend (zie voorbeeld in afbeelding 43 en <strong>de</strong> voorschriften <strong>van</strong><br />

§ 4.4).<br />

4.4.2.6.2. Steunmuur of tegengevel <strong>op</strong> een hoogte groter dan of gelijk aan H<br />

Wanneer <strong>de</strong> referentiehoogte <strong>van</strong> <strong>de</strong> steunmuur groter is dan of gelijk is aan H, hoeft <strong>het</strong><br />

<strong>buitenschrijnwerk</strong> normaalgesproken geen borstweringsfunctie te vervullen, vermits <strong>de</strong><br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

68


eschermingshoogte toereikend is (zie § 2.2.8). In dit geval dient men voor <strong>de</strong><br />

borstweringsfunctie <strong>van</strong> <strong>het</strong> schrijnwerk geen enkele controle uit te voeren, noch door<br />

berekening, noch <strong>op</strong> basis <strong>van</strong> proeven. Wat <strong>het</strong> glastype betreft, schrijft <strong>de</strong> norm NBN S 23-002<br />

(§ 4.4.2.2.1, geval 3, tabel 5) evenmin veiligheidsglas voor. De toepassing <strong>van</strong> veiligheidsglas<br />

wordt alleen aanbevolen wanneer <strong>het</strong> gebouw tot een specifieke gebruikscategorie behoort en<br />

indien er in <strong>de</strong> <strong>ontwerp</strong>situatie re<strong>de</strong>lijkerwijze an<strong>de</strong>re schokken voorzienbaar zien dan<br />

acci<strong>de</strong>ntele schokken, veroorzaakt door een menselijk lichaam (bv. schokken veroorzaakt door<br />

een bal in een sportzaal, <strong>op</strong> een speelplaats).<br />

Afbeelding 48 Veiligheid <strong>van</strong> personen – Steunmuur met een hoogte gelijk aan <strong>de</strong><br />

beschermingshoogte H.<br />

4.4.2.6.3. Hoogte <strong>van</strong> een steunmuur of <strong>van</strong> een tegengevel indien h < H en voor een<br />

valhoogte hc ≤ 1,50 m<br />

Gelet <strong>op</strong> <strong>de</strong> <strong>de</strong>finitie <strong>van</strong> <strong>de</strong> borstweringsfunctie uit § 2.2.8, moet in dit geval enkel <strong>de</strong> preventie<br />

<strong>van</strong> verwondingen door contact met grote glasscherven wor<strong>de</strong>n verzekerd. Vermits <strong>de</strong> valhoogte<br />

hc ≤ 1,50 m, is <strong>de</strong> bescherming tegen struikelen en uit <strong>het</strong> venster vallen normaalgesproken<br />

immers niet noodzakelijk. Dit impliceert dat :<br />

− <strong>de</strong>zelf<strong>de</strong> voorschriften <strong>van</strong> kracht zullen zijn, ongeacht <strong>het</strong> feit of <strong>het</strong> <strong>buitenschrijnwerk</strong><br />

(venster of gordijngevel) nu <strong>op</strong>engaan<strong>de</strong> <strong>de</strong>len omvat of niet<br />

− voor <strong>het</strong> schrijnwerk enkel <strong>de</strong> controle on<strong>de</strong>r dynamische belasting (schokproeven) dient<br />

uitgevoerd te wor<strong>de</strong>n.<br />

Afbeelding 49 Veiligheid <strong>van</strong> personen – Steunmuur met h < H en hc ≤ 1,50 m.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

69


Wat <strong>het</strong> glastype betreft, schrijft <strong>de</strong> norm NBN S 23-002 (§ 4.4.2.2.1, geval 1, tabel 5) een<br />

veiligheidsglas <strong>van</strong> breuktype C (gehard glas) of B (gelaagd glas) voor. Om <strong>de</strong> correcte keuze<br />

<strong>van</strong> <strong>het</strong> glastype mogelijk te maken, kan men een beroep doen <strong>op</strong> § 4.4.2 <strong>van</strong> <strong>de</strong> norm.<br />

4.4.2.6.4. Hoogte <strong>van</strong> een steunmuur of <strong>van</strong> een tegengevel indien h < H en voor een<br />

valhoogte hc > 1,50 m<br />

4.4.2.6.4.1. Geval <strong>van</strong> schrijnwerk zon<strong>de</strong>r <strong>op</strong>engaan<strong>de</strong> vleugels on<strong>de</strong>r <strong>de</strong> hoogte H<br />

Gelet <strong>op</strong> <strong>de</strong> <strong>de</strong>finitie <strong>van</strong> <strong>de</strong> borstweringsfunctie (§ 2.2.8), moet in dit geval enkel <strong>de</strong><br />

bescherming tegen uit <strong>het</strong> venster vallen en <strong>de</strong> preventie <strong>van</strong> verwondingen door contact met<br />

grote glasscherven wor<strong>de</strong>n verzekerd. Vermits <strong>de</strong> gevel geen <strong>op</strong>engaan<strong>de</strong> vleugels bevat, is <strong>de</strong><br />

bescherming tegen struikelen normaalgesproken immers niet noodzakelijk.<br />

Indien er <strong>op</strong> een hoogte ht < 0,45 m boven <strong>het</strong> niveau <strong>van</strong> <strong>de</strong> afgewerkte vloer een dorpel of een<br />

an<strong>de</strong>r element met een breedte e <strong>van</strong> meer dan 0,3 m aanwezig is, waar<strong>op</strong> <strong>het</strong> mogelijk is een<br />

voet te plaatsen, wordt <strong>de</strong> beschermingshoogte H berekend <strong>van</strong>af <strong>het</strong> hoogste niveau <strong>van</strong> dit<br />

element (zie afbeelding 50B).<br />

De controle <strong>van</strong> <strong>de</strong> borstweringsfunctie moet gebeuren volgens <strong>de</strong> aanbevelingen uit § 4.4.2.6.5<br />

(samenvatten<strong>de</strong> tabellen).<br />

Wat <strong>het</strong> glastype betreft, schrijft <strong>de</strong> norm NBN S 23-002 (§ 4.4.2.2.1, geval 2, tabel 5) een<br />

veiligheidsglas <strong>van</strong> <strong>het</strong> breuktype B (gelaagd glas) voor. Om <strong>de</strong> correcte keuze <strong>van</strong> <strong>het</strong> glastype<br />

mogelijk te maken, kan men een beroep doen <strong>op</strong> § 4.4.2 <strong>van</strong> <strong>de</strong> norm.<br />

Afbeelding 50 Veiligheid <strong>van</strong> personen – Steunmuur h < H en hc > 1,50 m – Vaste<br />

schrijnwerkelementen.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

70


4.4.2.6.4.2. Geval <strong>van</strong> schrijnwerk met <strong>op</strong>engaan<strong>de</strong> vleugels<br />

Gelet <strong>op</strong> <strong>de</strong> <strong>de</strong>finitie <strong>van</strong> <strong>de</strong> borstweringsfunctie (§ 2.2.8), kan <strong>het</strong> <strong>buitenschrijnwerk</strong> in dit geval<br />

enkel <strong>de</strong> preventie <strong>van</strong> verwondingen door contact met grote glasscherven verzekeren. Zodra :<br />

− <strong>de</strong> gevel een <strong>op</strong>engaan<strong>de</strong> vleugel bevat waarlangs <strong>de</strong> doorgang <strong>van</strong> een menselijk lichaam<br />

mogelijk is,<br />

− <strong>de</strong> hoogte <strong>van</strong> <strong>de</strong> steunmuur h < H,<br />

− <strong>de</strong> valhoogte hc > 1,50 m,<br />

is <strong>het</strong> immers noodzakelijk <strong>het</strong> risico <strong>op</strong> struikelen en door <strong>het</strong> venster vallen te waarborgen.<br />

Deze functies kunnen niet vervuld wor<strong>de</strong>n door <strong>het</strong> schrijnwerk.<br />

In dit geval legt <strong>de</strong> norm NBN B 25-002-1 (§ 5.2.2.10.2.2 en § 5.2.3.10.2.2) <strong>de</strong> eis <strong>op</strong> om <strong>de</strong><br />

muur<strong>op</strong>ening te voorzien <strong>van</strong> een borstwering overeenkomstig <strong>de</strong> norm NBN B 03-004 (in<br />

voorbereiding), die <strong>de</strong> beschermingshoogten aangeeft.<br />

De breedte <strong>van</strong> <strong>de</strong> gevel l mag geïntegreerd wor<strong>de</strong>n in <strong>de</strong> breedte <strong>van</strong> <strong>de</strong> borstwering.<br />

Indien er <strong>op</strong> een hoogte ht < 0,45 m boven <strong>het</strong> niveau <strong>van</strong> <strong>de</strong> afgewerkte vloer een dorpel of een<br />

an<strong>de</strong>r element met een breedte e <strong>van</strong> meer dan 0,3 m aanwezig is, waar<strong>op</strong> <strong>het</strong> mogelijk is een<br />

voet te plaatsen, wordt <strong>de</strong> beschermingshoogte H berekend <strong>van</strong>af <strong>het</strong> hoogste niveau <strong>van</strong> dit<br />

element (zie afbeelding 51B).<br />

Afbeelding 51 Veiligheid <strong>van</strong> personen – Steunmuur h < H en hc > 1,0 m – Schrijnwerk met<br />

<strong>op</strong>engaan<strong>de</strong> vleugel – Gevallen A, B, C.<br />

Wat <strong>het</strong> glastype betreft, schrijft <strong>de</strong> norm NBN S 23-002 (§ 4.4.2.2.1, geval 2) voor <strong>de</strong> situaties<br />

A en B (afbeelding 51) <strong>het</strong> gebruik <strong>van</strong> veiligheidsglas <strong>van</strong> <strong>het</strong> breuktype C (gehard glas) of B<br />

(gelaagd glas) voor. Voor situatie C legt <strong>de</strong> norm <strong>het</strong> gebruik <strong>van</strong> een breuktype A (floatglas) <strong>op</strong>.<br />

Om <strong>de</strong> correcte keuze <strong>van</strong> <strong>het</strong> glastype mogelijk te maken, kan men een beroep doen <strong>op</strong> § 4.4.2<br />

<strong>van</strong> <strong>de</strong> norm.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

71


Voor <strong>de</strong> in afbeelding 51 voorgestel<strong>de</strong> situatie C wordt geen enkele schrijnwerkcontrole<br />

aanbevolen.<br />

In <strong>het</strong> geval D uit afbeelding 52, zorgen <strong>de</strong> borstwering en <strong>de</strong> vensterborstwering er samen voor<br />

dat <strong>de</strong> wand een borstweringsfunctie kan vervullen. Het voorkomen <strong>van</strong> struikelen wordt<br />

verzekerd door <strong>de</strong> borstwering, terwijl een val uit <strong>het</strong> venster wordt tegengegaan door <strong>de</strong><br />

borstwering en <strong>de</strong> vensterborstwering samen. De vensterborstwering moet dus behan<strong>de</strong>ld<br />

wor<strong>de</strong>n in overeenstemming met <strong>de</strong> eisen uit § 4.4.2.6.4.1 en <strong>de</strong> borstwering volgens <strong>de</strong> norm<br />

NBN B 03-004. De <strong>op</strong>engaan<strong>de</strong> vleugel moet <strong>op</strong> zijn beurt in staat zijn om <strong>het</strong> risico <strong>op</strong><br />

verwondingen door contact te minimaliseren. Om <strong>de</strong> juiste keuze <strong>van</strong> <strong>het</strong> glastype mogelijk te<br />

maken, kan men een beroep doen <strong>op</strong> <strong>de</strong> norm NBN S 23-002 (§ 4.4.2).<br />

Afbeelding 52 Veiligheid <strong>van</strong> personen – Vensterborstwering met h < H en hc > 1,5 m –<br />

Schrijnwerk met <strong>op</strong>engaan<strong>de</strong> vleugel – Geval D.<br />

4.4.2.6.5. Samenvatten<strong>de</strong> tabellen voor <strong>de</strong> beoor<strong>de</strong>ling <strong>van</strong> <strong>de</strong> borstweringsfunctie<br />

In <strong>de</strong> tabellen 17, 18 en 19 wordt een samenvatting gegeven voor <strong>de</strong> beoor<strong>de</strong>ling <strong>van</strong> <strong>de</strong><br />

borstweringsfunctie in een gevel, rekening hou<strong>de</strong>nd met <strong>de</strong> gebruikscategorie en <strong>de</strong><br />

<strong>ontwerp</strong>voorwaar<strong>de</strong>n.<br />

Hierbij wor<strong>de</strong>n <strong>de</strong> volgen<strong>de</strong> symbolen gebruikt :<br />

• N : niet <strong>van</strong> toepassing<br />

• NBW : niet <strong>van</strong> toepassing, aanwezigheid <strong>van</strong> een borstwering vereist<br />

• S xxx : berekening in <strong>de</strong> gebruikgsgrenstoestand on<strong>de</strong>r <strong>de</strong> belasting Ab xxx (zie hieron<strong>de</strong>r<br />

voor <strong>de</strong> <strong>de</strong>tails)<br />

• SU xxx : berekening in <strong>de</strong> gebruiksgrenstoestand en in <strong>de</strong> uiterste grenstoestand on<strong>de</strong>r <strong>de</strong><br />

belasting Ab xxx<br />

• ≤ H : dynamische belasting (schok) die hoogstens aangrijpt <strong>op</strong> <strong>de</strong> beschermingshoogte; <strong>de</strong> in<br />

<strong>de</strong> tabel aangegeven waar<strong>de</strong> is <strong>de</strong> valhoogte <strong>van</strong> <strong>de</strong> in <strong>de</strong> norm NBN B 25-002-1 bepaal<strong>de</strong><br />

impactor<br />

• Prof : belasting die aangrijpt <strong>op</strong> <strong>het</strong> profiel<br />

• Vul : belasting die aangrijpt <strong>op</strong> <strong>het</strong> vulelement<br />

• h : referentiehoogte voor <strong>de</strong> beschermingshoogte (zie § 4.4.2.3).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

72


De belastingen Ab zijn ge<strong>de</strong>tailleerd in tabel 15. Ter herinnering :<br />

o qk,h : lineaire kracht (kN/m)<br />

o Qk,h1 en Qk,h2 : geconcentreer<strong>de</strong> horizontale krachten (horizontale puntbelastingen) (kN)<br />

o Qk,v3 : geconcentreer<strong>de</strong> verticale kracht (verticale puntbelasting) (kN).<br />

Nota 30 : <strong>de</strong> in tabel 15 vermel<strong>de</strong> belastingen zijn brutobelastingen. De nettorekenwaar<strong>de</strong>n<br />

wor<strong>de</strong>n verkregen door <strong>de</strong>ze waar<strong>de</strong>n te vermenigvuldigen met <strong>de</strong> begelei<strong>de</strong>n<strong>de</strong> coëfficiënten<br />

en <strong>de</strong> partiële coëfficiënten, <strong>op</strong>gegeven in <strong>de</strong> tabellen <strong>van</strong> § 4.6.<br />

De aangrijpingspunten <strong>van</strong> <strong>de</strong> belastingen zijn vermeld in § 4.4.2.5.4.<br />

Wanneer er geen valgevaar bestaat, d.w.z. indien hc ≤ 1,5 m moet <strong>de</strong> controle <strong>van</strong> <strong>de</strong> prestaties<br />

in <strong>de</strong>ze tabellen enkel beschouwd wor<strong>de</strong>n als een aanbeveling. Wanneer <strong>het</strong> risico <strong>op</strong> vallen<br />

daarentegen reëel is, d.w.z. als h < H en hc > 1,5 m, moet <strong>het</strong> geheel <strong>de</strong>r controles uitgevoerd<br />

wor<strong>de</strong>n.<br />

Wat <strong>de</strong> dynamische belastingen (schokken) betreft, kan men voor bijkomen<strong>de</strong> informatie terecht<br />

in <strong>de</strong> norm NBN B 25-002-1.<br />

De tabellen 17 en 18 hebben betrekking <strong>op</strong> belastingen die kunnen aangrijpen binnenin <strong>het</strong><br />

gebouw, terwijl tabel 19 <strong>van</strong> toepassing is <strong>op</strong> externe belastingen.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

73


Tabel 17 Borstweringsfunctie – Belastingen voor <strong>de</strong> gebruikscategorieën A, B, D en E.<br />

h ≥ H h < H en hc ≤ 1,5 m<br />

Venster<br />

h < H en hc > 1,5 m<br />

Gevel<br />

Categorie Belasting<br />

Venster Gevel Venster Gevel<br />

Opengaan<strong>de</strong><br />

vleugel<br />

Vast Opengaan<strong>de</strong> vleugel Vast<br />

Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul<br />

qk,h N N N N N N N N NBW N S 0,5 N NBW N SU 0,5 N<br />

Qk,h1 N N N N N N N N NBW N S 1,0 N NBW N SU 1,0 N<br />

Qk,h2 N N N N N N N N S 0,5 ( 1 ) N S 0,5 N SU 0,5 ( 1 Qk,v3 N N N N N N N N S 1,0 (<br />

) N SU 0,5 N<br />

2 ) N N ( 3 ) N SU 1,0 ( 2 ) N N ( 3 A<br />

) N<br />

Dyn ≤ H N N N N N 300 300 300 N 300 N 300 300 300 300 300<br />

qk,h N N N N N N N N NBW N S 1,0 N NBW N SU 1,0 N<br />

Qk,h1 N N N N N N N N NBW N S 1,0 N NBW N SU 1,0 N<br />

Qk,h2 N N N N N N N N S 0,5 ( 1 ) N S 0,5 N SU 0,5 ( 1 Qk,v3 N N N N N N N N S 1,0 (<br />

) N N N<br />

2 ) N N ( 3 ) N SU 1,0 ( 2 ) N N ( 3 B<br />

) N<br />

Dyn ≤ H N N N N N 450 450 450 N 450 N 450 450 450 450 450<br />

qk,h N N N N N N N N NBW N S 1,0 N NBW N SU 1,0 N<br />

Qk,h1 N N N N N N N N NBW N S 1,0 N NBW N SU 1,0 N<br />

Qk,h2 N N N N N N N N S 0,5 ( 1 ) N S 0,5 N SU 0,5 ( 1 Qk,v3 N N N N N N N N S 1,0 (<br />

) N SU 0,5 N<br />

2 ) N N ( 3 ) N SU 1,0 ( 2 ) N N ( 3 D<br />

) N<br />

Dyn ≤ H N N N N N 700 700 700 N 700 N 700 700 700 700 700<br />

qk,h N N N N N N N N NBW N S 1,0 N NBW SU 1,0 SU 1,0 SU 1,0<br />

Qk,h1 N N N N N N N N NBW N S 1,0 N NBW SU 1,0 SU 1,0 SU 1,0<br />

Qk,h2 N N N N N N N N S 0,5 ( 1 ) N S 0,5 N SU 0,5 ( 1 Qk,v3 N N N N N N N N S 1,0 (<br />

) SU 0,5 SU 0,5 SU 0,5<br />

2 ) N N ( 3 ) N SU 1,0 ( 2 ) N N ( 3 E<br />

) N<br />

Statisch<br />

Statisch<br />

Statisch<br />

Statisch<br />

Dyn ≤ H N N N N N 700 700 700 N 700 N 700 700 700 700 700<br />

( 1 ) Uitsluitend <strong>op</strong> <strong>de</strong> dwarsregels <strong>op</strong> of on<strong>de</strong>r <strong>de</strong> beschermingshoogte H (§ 4.4.2.6.4.2, geval D).<br />

( 2 ) Uitsluitend <strong>op</strong> <strong>de</strong> bovenste dwarsregel die zich on<strong>de</strong>r <strong>de</strong> <strong>op</strong>engaan<strong>de</strong> vleugel bevindt <strong>op</strong> een hoogte ≤ H (§ 4.4.2.6.4.2, geval D).<br />

( 3 ) Uitsluitend <strong>op</strong> <strong>de</strong> dwarsregels <strong>op</strong> of on<strong>de</strong>r <strong>de</strong> beschermingshoogte H (§ 4.4.2.6.4.1, geval C).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

74<br />

74


Tabel 18 Borstweringsfunctie – Belastingen voor <strong>de</strong> gebruikscategorie C.<br />

h ≥ H h < H en hc ≤ 1,50 m<br />

Venster<br />

h < H en hc > 1,50 m<br />

Gevel<br />

Categorie Belasting<br />

Venster Gevel Venster Gevel<br />

Opengaan<strong>de</strong><br />

vleugel<br />

Vast Opengaan<strong>de</strong> vleugel Vast<br />

Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul<br />

qk,h N N N N N N N N NBW N S 1,0 N NBW N SU 1,0 N<br />

Qk,h1 N N N N N N N N NBW N S 1,0 N NBW N SU 1,0 N<br />

Qk,h2 N N N N N N N N S 0,5 ( 1 ) N S 0,5 N SU 0,5 ( 1 Qk,v3 N N N N N N N N S 1,0 (<br />

) N SU 0,5 N<br />

2 ) N N ( 3 ) N SU 1,0 ( 2 ) N N ( 3 C1<br />

) N<br />

Dyn ≤ H N N N N N 700 700 700 N 700 N 700 700 700 700 700<br />

C2 – C3<br />

C4<br />

C5<br />

Statisch<br />

Statisch<br />

Statisch<br />

qk,h N N N N N N N N NGC N S 1,0 N NBW N SU 1,0 N<br />

Qk,h1 N N N N N N N N NGC N S 1,0 N NBW N SU 1,0 N<br />

Qk,h2 N N N N N N N N S 0,5 ( 1 ) N S 0,5 N SU 0,5 ( 1 ) N SU 0,5 N<br />

Qk,v3 N N N N N N N N S 1,0 ( 2 ) N N ( 3 ) N SU 1,0 ( 2 ) N N ( 3 ) N<br />

Dyn ≤ H N N N N N 450 450 450 N 700 N 700 700 700 700 700<br />

qk,h N N N N N N N N NBW N S 1,0 N NBW N SU 1,0 N<br />

Qk,h1 N N N N N N N N NBW N S 1,0 N NBW N SU 1,0 N<br />

Qk,h2 N N N N N N N N S 0,5 ( 1 ) N S 0,5 N SU 0,5 ( 1 ) N SU 0,5 N<br />

Qk,v3 N N N N N N N N S 1,0 ( 2 ) N N ( 3 ) N SU 1,0 ( 2 ) N N ( 3 ) N<br />

Dyn ≤ H N N N N N 700 700 700 N 700 N 700 700 700 700 700<br />

qk,h<br />

( 4 N N N N N N N N NBW N S 5,0 N NBW SU 5,0 SU 5,0 SU 5,0<br />

)<br />

S 3,0<br />

SU 3,0 SU 3,0 SU 3,0<br />

Qk,h1 N N N N N N N N NBW N S 2,0 N NBW SU 2,0 SU 2,0 SU 2,0<br />

Qk,h2 N N N N N N N N S 0,5 ( 1 ) N S 0,5 N SU 0,5 ( 1 ) SU 0,5 SU 0,5 SU 0,5<br />

Qk,v3 N N N N N N N N S 1,0 ( 2 ) N N ( 3 ) N SU 1,0 ( 2 ) N N ( 3 ) N<br />

Statisch<br />

Dyn ≤ H N N N N N 700 700 700 N 700 N 700 700 700 700 700<br />

( 1 ) Uitsluitend <strong>op</strong> <strong>de</strong> dwarsregels <strong>op</strong> of on<strong>de</strong>r <strong>de</strong> beschermingshoogte H (§ 4.4.2.6.4.2, geval D).<br />

( 2 ) Uitsluitend <strong>op</strong> <strong>de</strong> bovenste dwarsregel die zich on<strong>de</strong>r <strong>de</strong> <strong>op</strong>engaan<strong>de</strong> vleugel bevindt <strong>op</strong> een hoogte ≤ H (§ 4.4.2.6.4.2, geval D).<br />

( 3 ) Uitsluitend <strong>op</strong> <strong>de</strong> dwarsregels <strong>op</strong> of on<strong>de</strong>r <strong>de</strong> beschermingshoogte H (§ 4.4.2.6.4.1, geval C).<br />

( 4 ) De te kiezen waar<strong>de</strong> is <strong>op</strong>gegeven in tabel 15.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

75<br />

75


Tabel 19 Borstweringsfunctie – Belastingen, afhankelijk <strong>van</strong> <strong>de</strong> toegankelijkheid.<br />

h ≥ H h < H en hc ≤ 1,50 m<br />

Venster<br />

h < H en hc > 1,50 m<br />

Gevel<br />

Categorie Belasting<br />

Venster Gevel Venster Gevel<br />

Opengaan<strong>de</strong><br />

vleugel<br />

Vast Opengaan<strong>de</strong> vleugel Vast<br />

Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul Prof Vul<br />

qk,h N N N N N N N N NBW N S 1,0 N NBW N SU 1,0 N<br />

Qk,h1<br />

Qk,h2<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

NBW<br />

S 0,5 (<br />

N S 1,0 N NBW N SU 1,0 N<br />

1 ) N S 0,5 N SU 0,5 ( 1 Qk,v3 N N N N N N N N S 1,0 (<br />

) N SU 0,5 N<br />

1 ) N N ( 3 ) N SU 1,0 ( 2 ) N N ( 3 Toegankelijk<br />

voor <strong>het</strong><br />

publiek<br />

) N<br />

Dyn ≤ H N N N N N 700 700 700 N 700 N 700 700 700 700 700<br />

qk,h N N N N N N N N NBW N S 1,0 N NBW N SU 1,0 N<br />

Qk,h1<br />

Qk,h2<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

NBW<br />

S 0,5 (<br />

N S 1,0 N NBW N SU 1,0 N<br />

1 ) N S 0,5 N SU 0,5 ( 1 Qk,v3 N N N N N N N N S 1,0 (<br />

) N SU 0,5 N<br />

2 ) N N ( 3 ) N SU 1,0 ( 2 ) N N ( 3 Niet<br />

rechtstreeks<br />

toegankelijk<br />

voor <strong>het</strong><br />

) N<br />

Statisch<br />

Statisch<br />

publiek Dyn ≤ H N N N N N 300 300 300 N 300 N 300 300 300 300 300<br />

( 1 ) Uitsluitend <strong>op</strong> <strong>de</strong> dwarsregels <strong>op</strong> of on<strong>de</strong>r <strong>de</strong> beschermingshoogte H (§ 4.4.2.6.4.2, geval D).<br />

( 2 ) Uitsluitend <strong>op</strong> <strong>de</strong> bovenste dwarsregel die zich on<strong>de</strong>r <strong>de</strong> <strong>op</strong>engaan<strong>de</strong> vleugel bevindt <strong>op</strong> een hoogte ≤ H (§ 4.4.2.6.4.2, geval D).<br />

( 3 ) Uitsluitend <strong>op</strong> <strong>de</strong> dwarsregels <strong>op</strong> of on<strong>de</strong>r <strong>de</strong> beschermingshoogte H (§ 4.4.2.6.4.1, geval C).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

76<br />

76


4.5. Ontbinding <strong>van</strong> <strong>de</strong> belastingen<br />

4.5.1. De wind<br />

Men laat <strong>de</strong> wind w gewonlijk loodrecht aangrijpen <strong>op</strong> <strong>de</strong> gevelwan<strong>de</strong>n of <strong>de</strong> daken, waarbij<br />

<strong>de</strong>ze ofwel een overdruk ofwel een on<strong>de</strong>rdruk uitoefent. Deze kracht wordt uitgedrukt in Pa<br />

(N/m²) en belast <strong>de</strong> betrokken elementen voornamelijk <strong>op</strong> doorbuiging.<br />

4.5.2. Het eigengewicht<br />

Het eigengewicht gk is een verticale blijven<strong>de</strong> (permanente) belasting. Deze wordt uitgedrukt in<br />

N/m² (Pa), in N/strekken<strong>de</strong> meter of in N, en kan ontbon<strong>de</strong>n wor<strong>de</strong>n in :<br />

− een component loodrecht <strong>op</strong> <strong>de</strong> constructie, gk┴, die een moment veroorzaakt :<br />

gk┴ = gk . cos(θ)<br />

− een evenwijdige component, gk//, die een axiale belasting teweegbrengt in <strong>de</strong> stijlen en een<br />

moment in <strong>de</strong> dwarsregels : gk// = gk . sin (θ).<br />

4.5.3. Sneeuw<br />

De sneeuw sk is een verticale veran<strong>de</strong>rlijke (variable) belasting, die in aanmerking moet<br />

genomen wor<strong>de</strong>n bij hellingen tussen 0° en 60°, waar<strong>op</strong> <strong>de</strong>ze een druk uitoefent. Deze kracht<br />

wordt uitgedrukt in N per m² horizontale <strong>op</strong>pervlakte (Pa), en kan ontbon<strong>de</strong>n wor<strong>de</strong>n in :<br />

− een component loodrecht <strong>op</strong> <strong>de</strong> constructie, s┴, die een moment veroorzaakt : s┴ = sk . cos²(θ)<br />

− een evenwijdige component, s//, die een axiale belasting teweegbrengt in <strong>de</strong> stijlen en een<br />

moment in <strong>de</strong> dwarsregels : s// = sk . cos(θ) . s sin(θ).<br />

4.5.4. Belastingen veroorzaakt door <strong>de</strong> borstweringsfunctie<br />

De horizontale veran<strong>de</strong>rlijke (variabele) belastingen wor<strong>de</strong>n uitgedrukt in N/m of in N, en<br />

kunnen ontbon<strong>de</strong>n wor<strong>de</strong>n in :<br />

− een component loodrecht <strong>op</strong> <strong>de</strong> constructie, Ah ┴, die een doorbuiging veroorzaakt :<br />

Ah ┴ = Ah . sin(θ)<br />

− een evenwijdige component, Ah //, die een axiale belasting teweegbrengt in <strong>de</strong> stijlen en een<br />

moment in <strong>de</strong> structurele dwarsregels : Ah // = Ah . cos(θ).<br />

De verticale veran<strong>de</strong>rlijke (variabele) belastingen wor<strong>de</strong>n uitgedrukt in N en kunnen ontbon<strong>de</strong>n<br />

wor<strong>de</strong>n in :<br />

− een component loodrecht <strong>op</strong> <strong>de</strong> constructie, Qkv,3┴, die een doorbuiging veroorzaakt :<br />

Qkv,3┴ = Qkv,3 . sin(θ)<br />

− een evenwijdige component, Qkv,3//, die een axiale belasting teweegbrengt in <strong>de</strong> stijlen en een<br />

moment in <strong>de</strong> structurele dwarsregels : Qkv,3// = Qkv,3 . cos(θ).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

77


sk cos(θ)<br />

sk// cos(θ)<br />

sk<br />

sk┴ cos(θ)<br />

θ°<br />

Ah ┴<br />

θ°<br />

Afbeelding 53 Ontbinding <strong>van</strong> <strong>de</strong> windbelasting, <strong>het</strong> eigengewicht, <strong>de</strong> sneeuwbelasting en <strong>de</strong><br />

belastingen veroorzaakt door <strong>de</strong> borstweringsfunctie.<br />

4.6. Rekenwaar<strong>de</strong> voor <strong>de</strong> belastingen, voor hun combinaties en<br />

criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

4.6.1. In aanmerking nemen <strong>van</strong> <strong>het</strong> gunstige effect <strong>van</strong> <strong>de</strong> blijven<strong>de</strong><br />

(permanente) en veran<strong>de</strong>rlijke (variabele) belastingen<br />

De veran<strong>de</strong>rlijke (variabele) belastingen die in aanmerking genomen wer<strong>de</strong>n in dit Rapport, zijn<br />

<strong>de</strong> windbelasitng, <strong>de</strong> sneeuwbelasting en <strong>de</strong> belastingen veroorzaakt door <strong>de</strong><br />

borstweringsfunctie. De voornaamste blijven<strong>de</strong> (permanente) belasting is <strong>het</strong> eigengewicht.<br />

Regels <strong>van</strong> toepassing <strong>op</strong> alle belastingscombinaties<br />

Wanneer een veran<strong>de</strong>rlijke (variabele) belasting een gunstig effect heeft in een<br />

belastingscombinatie (vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> resultante Fd), moet ook <strong>de</strong> belastingscombinatie<br />

waarin <strong>de</strong>ze veran<strong>de</strong>rlijke belasting gelijk is aan nul in aanmerking genomen wor<strong>de</strong>n.<br />

Wanneer een blijven<strong>de</strong> (permanente) belasting een gunstig effect heeft in een<br />

belastingscombinatie (m.a.w. indien <strong>de</strong>ze aanleiding geeft tot een vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong><br />

resulteren<strong>de</strong> rekenwaar<strong>de</strong> Fd), moet <strong>de</strong>ze gunstige blijven<strong>de</strong> (permanente) belasting in <strong>de</strong><br />

belastingscombinatie in rekening gebracht wor<strong>de</strong>n door een partiële coëfficiënt γG,inf = 1.<br />

Deze regels kunnen een belangrijke invloed hebben <strong>op</strong> <strong>de</strong> dimensionering <strong>van</strong> <strong>het</strong> bereken<strong>de</strong><br />

element, in <strong>het</strong> bijzon<strong>de</strong>r indien <strong>het</strong> gedrag <strong>van</strong> <strong>het</strong> materiaal afhankelijk is <strong>van</strong> <strong>de</strong><br />

toepassingsduur <strong>van</strong> <strong>de</strong> belasting (kmod en/of k<strong>de</strong>f voor glas en hout).<br />

Wanneer men in <strong>het</strong> geval <strong>van</strong> een hellen<strong>de</strong> gevel een ontbinding maakt <strong>van</strong> <strong>de</strong> belastingen<br />

evenwijdig met of loodrecht <strong>op</strong> <strong>het</strong> <strong>op</strong>pervlak <strong>van</strong> <strong>het</strong> bereken<strong>de</strong> element, is <strong>het</strong> mogelijk dat één<br />

component <strong>van</strong> <strong>de</strong> belasting een gunstig effect heeft, terwijl <strong>de</strong> an<strong>de</strong>re een ongunstig effect<br />

heeft. In voorkomend geval dient men <strong>de</strong>ze in aanmerking te nemen volgens hun<br />

respectievelijke effect (zie voorbeeld in bijlage 6).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

A h<br />

θ°<br />

Ah//<br />

w<br />

w<br />

Qkv,3<br />

θ°<br />

θ°<br />

gk┴<br />

gk//<br />

Qkv,3 //<br />

Qkv,3 ┴<br />

θ°<br />

gk<br />

gk<br />

78


4.6.2. Geval <strong>van</strong> gevels<br />

4.6.2.1. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>de</strong> winddruk Fd(w)<br />

Rekening hou<strong>de</strong>nd met <strong>de</strong> verschillen<strong>de</strong> coëfficiënten voor <strong>de</strong> grenstoestan<strong>de</strong>n, kan <strong>de</strong><br />

winddruk w (zie § 4.1.2) als volgt uitgedrukt wor<strong>de</strong>n :<br />

− in <strong>de</strong> gebruiksgrenstoestand (GGT) : Fd(w) = ψ 1 . ce(z)qref 50jaar cprob² . cp<br />

− in <strong>de</strong> uiterste grenstoestand (UGT) : Fd(w) = γQ . ce(z)qref 50jaar cprob² . cp<br />

waarbij :<br />

− Fd(w) : <strong>de</strong> rekenwaar<strong>de</strong> voor <strong>de</strong> windbelasting<br />

− γQ : <strong>de</strong> partiële coëfficiënt voor <strong>de</strong> wind<br />

− ψ1 : <strong>de</strong> begelei<strong>de</strong>n<strong>de</strong> coëfficiënt voor <strong>de</strong> wind<br />

− γM : <strong>de</strong> partiële coëfficiënt voor <strong>de</strong> materialen (zie hoofdstuk 5)<br />

− Xd : <strong>de</strong> rekenwaar<strong>de</strong> voor <strong>de</strong> materialen (zie hoofdstuk 5).<br />

De rekenwaar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>de</strong> winddruk Fd(w) en <strong>de</strong> criteria voor <strong>de</strong><br />

grenstoestan<strong>de</strong>n zijn <strong>op</strong>genomen in tabel 20.<br />

4.6.2.2. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht Fd(gk)<br />

Rekening hou<strong>de</strong>nd met <strong>de</strong> verschillen<strong>de</strong> coëfficiënten voor <strong>de</strong> grenstoestan<strong>de</strong>n, kan <strong>de</strong> belasting<br />

veroorzaakt door <strong>het</strong> eigengewicht gk (zie § 4.2) als volgt uitgedrukt wor<strong>de</strong>n :<br />

− in <strong>de</strong> gebruiksgrenstoestand : Fd(gk) = gk<br />

− in <strong>de</strong> uiterste grenstoestand : Fd(gk) = γG gk<br />

waarbij :<br />

− Fd(gk) : <strong>de</strong> rekenwaar<strong>de</strong> voor <strong>het</strong> eigengewicht<br />

− γG : <strong>de</strong> partiële coëfficiënt voor <strong>het</strong> eigengewicht<br />

− γM : <strong>de</strong> partiële coëfficiënt voor <strong>de</strong> materialen (zie hoofdstuk 5)<br />

− Xd : <strong>de</strong> rekenwaar<strong>de</strong> voor <strong>de</strong> materialen (zie hoofdstuk 5).<br />

De rekenwaar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht en <strong>de</strong> criteria voor <strong>de</strong><br />

grenstoestan<strong>de</strong>n zijn <strong>op</strong>genomen in tabel 22.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

79


Parameters<br />

Hoofdconstructie<br />

(veranda’s, categorie 3)<br />

Verankering <strong>van</strong> <strong>de</strong><br />

secundaire constructie ( 3 )<br />

Tabel 20 Bepaling <strong>van</strong> <strong>de</strong> belasting veroorzaakt door <strong>de</strong> winddruk Fd (w) <strong>op</strong> <strong>de</strong> schrijnwerkelementen – Gevels (1).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

Secundaire constructie<br />

Terugkeerperio<strong>de</strong> <strong>van</strong> <strong>de</strong> wind - cprob² 50 jaar - cprob² = 1 50 jaar - cprob² = 1 50 jaar - cprob² = 1<br />

Partiële coëfficiënt voor <strong>de</strong> wind γQ 1,5 1,35 1,25<br />

Begelei<strong>de</strong>n<strong>de</strong> coëfficiënt voor <strong>de</strong><br />

frequente belastingen ψ 1<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

Fd(w) = ψ 1. ce(z)qref 50jaar cprob² . cp<br />

Uiterste grenstoestan<strong>de</strong>n (UGT)<br />

Fd(w) = γQ. ce(z)qref 50jaar cprob² . cp<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

– 0,90 0,90<br />

Zie Euroco<strong>de</strong>s en<br />

normen<br />

Zie Euroco<strong>de</strong>s en<br />

normen<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Zie Euroco<strong>de</strong>s en<br />

normen<br />

Waar<strong>de</strong>n voor <strong>de</strong> winddruk<br />

Fd(w) = 0,90 ce(z)qref 50jaar .cp<br />

Fd(w) = 1,35 ce(z)qref 50jaar .cp<br />

( 2 )<br />

Vensters en<br />

veranda’s<br />

(categorie 1)<br />

y ≤ L/225 of<br />

≤ 13 mm<br />

Fd(w) = 0,90 ce(z)qref 50jaar .cp<br />

Fd(w) = 1,25 ce(z)qref 50jaar .cp<br />

Gordijngevels en veranda’s<br />

(categorie 2)<br />

Vervorming ( 4 )<br />

y ≤ L/200 indien L ≤ 3,0 m<br />

y ≤ 5 + L/300 indien 3,0 m < L < 7,5 m<br />

y ≤ L/250 indien L ≥ 7,5 m<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) Ed(w) ≤ Xd / γM ( 1 ) Ed(w) ≤ Xd / γM ( 1 ) Geen controle Ed(w) ≤ Xd / γM ( 1 )<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> winddruk (overdruk of on<strong>de</strong>rdruk).<br />

( 2 ) De verankeringen wor<strong>de</strong>n gewoonlijk enkel berekend in <strong>de</strong> uiterste grenstoestand. Indien nodig, moet <strong>het</strong> gebruiksgeschiktheidscriterium <strong>van</strong> <strong>de</strong> gebruiksgrenstoestand bepaald<br />

wor<strong>de</strong>n, rekening hou<strong>de</strong>nd met <strong>de</strong> <strong>ontwerp</strong>situatie.<br />

( 3 ) Bepaal<strong>de</strong> gevel<strong>ontwerp</strong>en voorzien verankeringen die zowel in staat moeten zijn <strong>de</strong> windbelastingen als <strong>het</strong> eigengewicht <strong>op</strong> te nemen. In voorkomend geval dient men <strong>de</strong><br />

belastingen uit <strong>de</strong>ze tabel <strong>op</strong> te tellen bij <strong>de</strong>ze uit tabel 21.<br />

( 4 ) Het voorgestel<strong>de</strong> vervormingscriterium kan aangepast wor<strong>de</strong>n naargelang <strong>van</strong> <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n (materialen, techniek, …)<br />

80


Tabel 21 Bepaling <strong>van</strong> <strong>de</strong> belasting veroorzaakt door <strong>de</strong> winddruk Fd(w) <strong>op</strong> <strong>de</strong> schrijnwerkelementen – Gevels (2).<br />

Parameters<br />

Verlijming <strong>van</strong> <strong>het</strong> SGG ( 2 ) of<br />

bevestiging <strong>van</strong> <strong>de</strong> vulelementen<br />

Vulelementen<br />

Terugkeerperio<strong>de</strong> <strong>van</strong> <strong>de</strong> wind - cprob² 25 jaar - cprob² = 0,92 25 jaar - cprob² = 0,92<br />

Partiële coëfficiënt voor <strong>de</strong> wind γQ 1,1 1,1<br />

Begelei<strong>de</strong>n<strong>de</strong> coëfficiënt voor <strong>de</strong> frequente belastingen ψ1 – 0,90<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) :<br />

Fd(w) = ψ 1 ce(z)qref 50jaar cprob² . cp<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) :<br />

Fd(w) = γQ ce(z)qref 50jaar cprob² . cp<br />

Waar<strong>de</strong>n voor <strong>de</strong> winddruk<br />

– Fd(w) = 0,83 ce(z)qref 50jaar . cp<br />

Fd(w) = 1,01 ce(z)qref 50jaar . cp<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

Fd(w) = 1,01 .ce(z)qref 50jaar . cp<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) – Vervorming of belasting ( 3 )<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) Ed(w) ≤ Xd / γM ( 1 ) Ed(w) ≤ Xd / γM ( 1 )<br />

( 1 )<br />

(<br />

Ed vertegenwoordigt <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> winddruk.<br />

2 ) Naast <strong>het</strong> in rekening brengen <strong>van</strong> <strong>de</strong> wind voor <strong>de</strong> dimensionering <strong>van</strong> <strong>de</strong> verlijmingshoogte hc,, dient men bij <strong>de</strong> dimensionering <strong>van</strong> <strong>het</strong> SGG (in geval <strong>van</strong><br />

schuifspannningen) ook <strong>het</strong> effect <strong>van</strong> <strong>het</strong> temperatuursverschil in aanmerking te nemen, met <strong>het</strong> oog <strong>op</strong> <strong>de</strong> bepaling <strong>van</strong> <strong>de</strong> verlijmingsdikte e (zie<br />

ETAG 002, SGG, bijlage B).<br />

( 3 ) Vervorming en/of belasting naargelang <strong>van</strong> <strong>de</strong> productspecificaties.<br />

81


Tabel 22 Bepaling <strong>van</strong> <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht Fd(gk) <strong>op</strong> <strong>de</strong> schrijnwerkelementen – Gevels (1).<br />

Parameters<br />

Partiële coëfficiënt voor <strong>het</strong><br />

eigengewicht γG<br />

Gebruiksgrenstoestan<strong>de</strong>n<br />

(GGT) : Fd(gk) = gk<br />

Uiterste grenstoestan<strong>de</strong>n<br />

(UGT) : Fd(gk) = gk γG<br />

Hoofdconstructie<br />

(veranda’s, categorie 3)<br />

Verankering <strong>van</strong> <strong>de</strong> secundaire<br />

constructie<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

Secundaire constructie<br />

1,35 1,20 1,15<br />

Waar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht<br />

Fd(gk) = gk ( 3 ) Fd(gk) = gk<br />

Zie Euroco<strong>de</strong>s en normen<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Fd(gk) = 1,20 gk<br />

Gebruiksgrenstoestan<strong>de</strong>n<br />

(GGT) Zie Euroco<strong>de</strong>s en normen ( 2 )<br />

Fd(gk) = 1,15.gk<br />

Vensters en veranda’s Gordijngevels en<br />

(categorie 1) veranda’s (categorie 2)<br />

Vervorming ( 3 )<br />

y ≤ L/500 of ≤ 3 mm y ≤ L/500 of ≤ 3 mm<br />

Uiterste grenstoestan<strong>de</strong>n Ed(gk) ≤ Xd /γm Ed(gk) ≤ Xd /γm (<br />

(UGT)<br />

1 ) Geen controle Ed(gk) ≤ Xd /γm ( 1 )<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>het</strong> eigengewicht.<br />

( 2 ) De verankeringen wor<strong>de</strong>n gewoonlijk enkel berekend in <strong>de</strong> uiterste grenstoestand. Indien nodig, moet <strong>het</strong> gebruiksgeschiktheidscriterium <strong>van</strong> <strong>de</strong> gebruiksgrenstoestand<br />

bepaald wor<strong>de</strong>n, rekening hou<strong>de</strong>nd met <strong>de</strong> <strong>ontwerp</strong>situatie.<br />

( 3 ) Dit vervormingscriterium geldt voor <strong>de</strong> eventuele dwarsregel wanneer <strong>het</strong> vulpaneel niet in staat is <strong>de</strong> belasting <strong>op</strong> te nemen. Het criterium kan aangepast wor<strong>de</strong>n<br />

naargelang <strong>van</strong> <strong>de</strong> maximaal toegelaten vervorming, zon<strong>de</strong>r <strong>het</strong> vulpaneel te raken. Wanneer <strong>de</strong> <strong>op</strong>spanning <strong>van</strong> <strong>de</strong> dwarsregel <strong>op</strong> <strong>het</strong> vulpaneel toegelaten is, moet <strong>de</strong><br />

stabiliteit <strong>van</strong> <strong>het</strong> vulelement gecontroleerd wor<strong>de</strong>n on<strong>de</strong>r verticale belastingen. Indien nodig, dient men een voldoen<strong>de</strong> ruimte te laten voor <strong>de</strong> drainering en <strong>de</strong><br />

ventilatie. Indien <strong>de</strong> dwarsregels erg assymetrisch zijn of <strong>de</strong> belastingen zeer excentrisch, kan <strong>het</strong> noodzakelijk blijken <strong>de</strong> dwarsregel te berekenen on<strong>de</strong>r torsie. Het<br />

criterium moet dan bepaald wor<strong>de</strong>n, rekening hou<strong>de</strong>nd met <strong>het</strong> behoud <strong>van</strong> <strong>de</strong> functionele prestaties <strong>van</strong> <strong>het</strong> bouwwerk.<br />

82


Tabel 23 Bepaling <strong>van</strong> <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht Fd(gk) <strong>op</strong> <strong>de</strong><br />

schrijnwerkelementen – Gevels (2).<br />

Verlijming <strong>van</strong> <strong>het</strong> SGG en<br />

Parameters<br />

bevestiging <strong>van</strong> <strong>de</strong><br />

vulelementen<br />

Vulelementen<br />

Partiële coëfficiënt voor <strong>het</strong> eigengewicht γG 1,1 1,1<br />

Waar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) :<br />

– – (<br />

Fd(gk) = gk<br />

3 )<br />

Fd(gk) = 1,1 gk ( 2 ) Fd(gk) = 1,1 gk<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) :<br />

Fd(gk) = gk γG<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) – –<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) Ed(gk) ≤ Xd /γm ( 1 ) –<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>het</strong> eigengewicht.<br />

( 2 ) Gewoonlijk wordt <strong>het</strong> eigengewicht <strong>van</strong> <strong>de</strong> vulelementen <strong>op</strong>genomen door toebehoren ad hoc. De verlijming<br />

<strong>van</strong> <strong>het</strong> SGG wordt <strong>op</strong> haar beurt zodanig gedimensioneerd dat <strong>de</strong>ze <strong>de</strong> effecten <strong>van</strong> <strong>het</strong> temperatuurverschil<br />

kan <strong>op</strong>nemen. Wanneer <strong>de</strong> verlijming <strong>het</strong> gewicht <strong>van</strong> <strong>de</strong> vulelementen <strong>op</strong>neemt, moeten <strong>de</strong> schuifspanningen<br />

in <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG in <strong>de</strong> gevel gecontroleerd wor<strong>de</strong>n door <strong>de</strong> afschuifcomponent <strong>van</strong> Fd(gk) te<br />

combineren met <strong>de</strong> effecten tengevolge <strong>van</strong> <strong>het</strong> temperatuurverschil, met <strong>het</strong> oog <strong>op</strong> <strong>de</strong> bepaling <strong>van</strong> <strong>de</strong><br />

verlijmingsdikte e <strong>van</strong> <strong>het</strong> SGG (ETAG 002, bijlage B).<br />

( 3 ) In <strong>de</strong> meeste <strong>ontwerp</strong>situaties voor gevels wordt <strong>de</strong> vervorming <strong>van</strong> <strong>het</strong> vulelement on<strong>de</strong>r zijn eigengewicht<br />

niet in aanmerking genomen.<br />

4.6.2.3. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong><br />

borstwering (Ab), <strong>de</strong> wind (w) en <strong>het</strong> eigengewicht (gk)<br />

Om te controleren of men voor <strong>de</strong> borstweringsfunctie <strong>de</strong> statische belastingen (zie § 4.4.2.5.1)<br />

in aanmerking moet nemen volgens <strong>de</strong> gebruikscatergorieën, dient men een beroep te doen <strong>op</strong> <strong>de</strong><br />

tabellen 17 en 19. In voorkomend geval, gelet <strong>op</strong> <strong>de</strong> aanwezigheid <strong>van</strong> <strong>de</strong> volgen<strong>de</strong> belastingen :<br />

• Ab = qk,h, Qkh,1, Qkh,2, Qkv,3 (zie § 4.4)<br />

• gk (zie § 4.2),<br />

• w (zie § 4.1)<br />

en rekening hou<strong>de</strong>nd met <strong>de</strong> verschillen<strong>de</strong> coëfficiënten voor <strong>de</strong> grenstoestan<strong>de</strong>n, dient men :<br />

− in <strong>de</strong> gebruiksgrenstoestand vier afzon<strong>de</strong>rlijke combinaties in aanmerking te nemen :<br />

Fd(1) = ψ1 qk,h + ψ2 .ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = ψ1 Qkh,1+ ψ2 ce(z)qref 50jaar cprob² . cp<br />

Fd(3) = ψ1 Qkh,2 + ψ2 ce(z)qref 50jaar cprob² . cp<br />

Fd(4) = ψ1 Qkv,3 + gk<br />

− in <strong>de</strong> uiterste grenstoestand vier afzon<strong>de</strong>rlijke rekenwaar<strong>de</strong>n in aanmerking te nemen :<br />

Fd(1) = γQ qk,h + γQ ψ0 ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = γQ Qkh,1 + γQ ψ0 ce(z)qref 50jaar cprob² . cp<br />

Fd(3) = γQQkh,2 + γQ ψ0 ce(z)qref 50jaar cprob² . cp<br />

Fd(4) = γQ Qkv,3 + γG gk<br />

waarbij :<br />

− Fd(X) : <strong>de</strong> rekenwaar<strong>de</strong> voor <strong>de</strong> belastingscombinatie<br />

− γQ : <strong>de</strong> partiële coëfficiënt voor <strong>de</strong> veran<strong>de</strong>rlijke belastingen<br />

− ψ0 : <strong>de</strong> coëfficiënt voor <strong>de</strong> gecombineer<strong>de</strong> waar<strong>de</strong> voor <strong>de</strong> wind<br />

− ψ1 : <strong>de</strong> begelei<strong>de</strong>n<strong>de</strong> coëfficiënt voor <strong>de</strong> wind<br />

− γM : <strong>de</strong> partiële coëfficiënt voor <strong>de</strong> materialen (zie hoofdstuk 5)<br />

− Xd : <strong>de</strong> rekenwaar<strong>de</strong> voor <strong>de</strong> materialen (zie hoofdstuk 5).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

83


Wanneer een belasting zeer excentrisch is ten aanzien <strong>van</strong> <strong>de</strong> profielas, dient men rekening te<br />

hou<strong>de</strong>n met <strong>de</strong> veroorzaakte torsiemomenten. De rekenwaar<strong>de</strong>n en <strong>de</strong> criteria voor <strong>de</strong><br />

grenstoestan<strong>de</strong>n zijn <strong>op</strong>genomen in <strong>de</strong> tabellen 24 en 25.<br />

Afbeelding 54 De borstweringsfunctie <strong>van</strong> een verticale gevel – Belastingen <strong>op</strong> en vervorming <strong>van</strong><br />

<strong>de</strong> dwarsregels.<br />

Qkv,3 is enkel<br />

<strong>van</strong> toepassing<br />

in geval <strong>van</strong> een<br />

<strong>op</strong>engaan<strong>de</strong><br />

vleugel<br />

Afbeelding 55 De borstweringsfunctie <strong>van</strong> een verticale gevel – Belastingen <strong>op</strong> en vervorming <strong>van</strong><br />

<strong>de</strong> stijlen.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

84


Parameters<br />

Hoofdconstructie<br />

(veranda’s,<br />

categorie 3)<br />

Begelei<strong>de</strong>n<strong>de</strong> coëfficiënt –<br />

Partiële coëfficiënt voor <strong>de</strong> belastingen<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

Fd(1) = ψ1 qk,h + ψ2 .ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = ψ1 Qkh,1.+ ψ2 ce(z)qref 50jaar cprob² . cp<br />

Fd(3) = ψ1 Qkh,2 + ψ2 ce(z)qref 50jaar cprob² . cp<br />

Fd(4) = ψ1 Qkv,3 + gk<br />

Uiterste grenstoestan<strong>de</strong>n (UGT)<br />

Fd(1) = γQ qk,h + γQ ψ0 ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = γQ. Qkh,1 + γQ ψ0 ce(z)qref 50jaar cprob² . cp<br />

Fd(3) = γQ .Qkh,2 + γQ ψ0 ce(z)qref 50jaar cprob² . cp<br />

Fd(4) = γQ Qkv,3 + γG gk<br />

Verankering <strong>van</strong> <strong>de</strong> secundaire constructie Secundaire constructie<br />

ψ0 ψ1 ψ2 ψ0 ψ1 ψ2<br />

0,3 0,7 0,0 0,3 0,7 0,0<br />

γQ γG γG γQ γQ γG<br />

1,50 1,35 1,20 1,35 1,25 1,15<br />

Waar<strong>de</strong>n voor <strong>de</strong> belastingscombinaties<br />

Zie Euroco<strong>de</strong>s en<br />

normen<br />

Zie Euroco<strong>de</strong>s en<br />

normen<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Fd(1) = 0,7 qk,h + 0,0.ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = 0,7 Qkh,1+ 0,0 ce(z)qref 50jaar cprob² . cp<br />

–<br />

Fd(4) = 0,7 Qkv,3 + gk<br />

Fd(1) = 1,35 qk,h + 0,4 ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = 1,35 Qk,1 + 0,4 ce(z)qref 50jaar cprob² . cp<br />

–<br />

Fd(4) = 1,35 Qkv,3 + 1,2.gk<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

85<br />

2009<br />

Fd(1) = 0,7 qk,h + 0,0.ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = 0,7 Qkh,1+ 0,0 ce(z)qref 50jaar cprob² . cp<br />

Fd(3) = 0,7 Qkh,2 + 0,0 ce(z)qref 50jaar cprob² . cp ( 5 )<br />

Fd(4) = 0,7 Qkv,3 + gk<br />

Fd(1) = 1,25 qk,h + 0,375 ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = 1,25 Qk,1 + 0,375 ce(z)qref 50jaar cprob² . cp<br />

Fd(3) = 1,25 Qk,2 + 0,375 ce(z)qref 50jaar cprob² . cp ( 5 )<br />

Fd(4) = 1,25 Qkv,3 +1,15. gk<br />

Vensters en<br />

veranda’s<br />

(categorie 1)<br />

Gordijngevels en veranda’s<br />

(categorie 2)<br />

Vervorming <strong>van</strong> <strong>de</strong> stijlen en <strong>de</strong> dwarsregels<br />

(zie afbeelding 54 en afbeelding 55) ( 6 Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

)<br />

( 1 ) y┴ ≤ L/200<br />

y// ≤ L/500 of<br />

≤ 3 mm ( 3 ) ( 4 )<br />

y┴ ≤ L/200 indien L ≤ 3,0 m<br />

y┴ ≤ 5 + L/300 indien 3,0 m < L < 7,5 m<br />

y┴ ≤ L/250 indien L ≥ 7,5 m<br />

y// ≤ L/500 of ≤ 3 mm ( 3 )( 4 Zie Euroco<strong>de</strong>s en<br />

normen<br />

)<br />

Uiterste grenstoestan<strong>de</strong>n (UGT)<br />

Ed(w) ≤ Xd / γM ( 2 ) Geen controle Ed(w) ≤ Xd / γM ( 2 )<br />

( 1 ) Deze wor<strong>de</strong>n gewoonlijk enkel in <strong>de</strong> UGT berekend. Indien nodig, moet <strong>het</strong> gebruiksgeschiktheidscriterium <strong>van</strong> <strong>de</strong> uiterste grenstoestand bepaald wor<strong>de</strong>n, rekening hou<strong>de</strong>nd met <strong>de</strong><br />

<strong>ontwerp</strong>situatie.<br />

( 2 ) Ed vertegenwoordigt <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> belastingscombinatie.<br />

( 3 ) Dit vervormingscriterium geldt voor <strong>de</strong> eventuele dwarsregel on<strong>de</strong>r <strong>de</strong> blijven<strong>de</strong> component Fd = gk wanneer <strong>het</strong> vulpaneel niet in staat is Fd(4) <strong>op</strong> te nemen. Het criterium kan aangepast<br />

wor<strong>de</strong>n naargelang <strong>van</strong> <strong>de</strong> maximaal toegelaten vervorming, zon<strong>de</strong>r <strong>het</strong> vulpaneel te raken. Wanneer <strong>de</strong> <strong>op</strong>spanning <strong>van</strong> <strong>de</strong> dwarsregel <strong>op</strong> <strong>het</strong> vulelement toegelaten is, moet <strong>de</strong><br />

stabiliteit <strong>van</strong> <strong>het</strong> vulelement gecontroleerd wor<strong>de</strong>n on<strong>de</strong>r Fd(4). Indien nodig, dient men een voldoen<strong>de</strong> ruimte te laten voor <strong>de</strong> drainering en <strong>de</strong> ventilatie.<br />

( 4 ) Dit vervormingscriterium geldt voor <strong>de</strong> stijlen en <strong>de</strong> eventuele dwarsregel <strong>op</strong> <strong>de</strong> veiligheidshoogte, on<strong>de</strong>r <strong>de</strong> belastingen Fd(1) en Fd(2), die afzon<strong>de</strong>rlijk in aanmerking genomen wor<strong>de</strong>n.<br />

Dit criterium kan eventueel ook toegepast wor<strong>de</strong>n <strong>op</strong> <strong>de</strong> belasting Fd(3), wanneer <strong>de</strong>ze aangrijpt <strong>op</strong> <strong>de</strong> dwarsregel (zie noot ( 5 ) hierna).<br />

( 5 ) Van toepassing <strong>op</strong> <strong>de</strong> situatie uit § 4.4.2.5.4.2 en afbeelding 46, wanneer <strong>de</strong> dwarsregel zich <strong>op</strong> een lagere hoogte bevindt dan <strong>de</strong> beschermingshoogte H.<br />

( 6 ) Het voorgestel<strong>de</strong> vervormingscriterium kan aangepast wor<strong>de</strong>n naargelang <strong>van</strong> <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n (materialen, techniek, …).<br />

Tabel 24 Bepaling <strong>van</strong> <strong>de</strong> gecombineer<strong>de</strong> belasting veroorzaakt door <strong>de</strong> borstwering, <strong>het</strong> eigengewicht en <strong>de</strong> wind Fd(Ab, gk, w) <strong>op</strong> gevels.<br />

85


Parameters<br />

Begelei<strong>de</strong>n<strong>de</strong> coëfficiënt<br />

Partiële coëfficiënt voor <strong>de</strong> belastingen<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

Fd(1) = ψ1 qk,h + ψ2 .ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = ψ1 Qkh,1 + ψ2 ce(z)qref 50jaar cprob² . cp<br />

Fd(3) = ψ1 Qkh,2 + ψ2 ce(z)qref 50jaar cprob² . cp<br />

Fd(4) = ψ1 Qkv,3 + gk<br />

Uiterste grenstoestan<strong>de</strong>n (UGT)<br />

Fd(1) = γQ qk,h + γQ ψ0 ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = γQ Qkh,1 + γQ ψ0 ce(z)qref 50jaar cprob² . cp<br />

Fd(3) = γQ Qkh,2 + γQ ψ0 ce(z)qref 50jaar cprob² . cp<br />

Fd(4) = γQ Qkv,3 + γG gk<br />

Verlijming <strong>van</strong> <strong>het</strong> SGG en bevestiging <strong>van</strong> <strong>de</strong><br />

vulelementen<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

86<br />

2009<br />

Vulementen<br />

ψ0 ψ1 ψ2 ψ0 ψ1 ψ2<br />

0,3 0,7 0,0 0,3 0,7 0,0<br />

γQ γG γQ γG<br />

1,1 1,1 1,1 1,1<br />

Waar<strong>de</strong>n voor <strong>de</strong> belastingscombinaties<br />

Fd(1) = 0,7 qk,h + 0,0.ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = 0,7 Qkh,1+ 0,0 ce(z)qref 50jaar cprob² . cp<br />

Fd(3) = 0,7 Qkh,2 + 0,0 ce(z)qref 50jaar cprob² . cp<br />

–<br />

Fd(1) = 1,1 qk,h + 0,33 ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = 1,1 Qkh,1 + 0,33 ce(z)qref 50jaar cprob² . cp<br />

Fd(3) = 1,1 Qkh,2 + 0,33 ce(z)qref 50jaar cprob² . cp<br />

–<br />

Fd(1) = 0,7 qk,h + 0,0.ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = 0,7 Qkh,1 + 0,0 ce(z)qref 50jaar cprob² . cp ( 4 )<br />

Fd(3) = 0,7 Qkh,2 + 0,0 ce(z)qref 50jaar cprob² . cp<br />

Fd(4) = 0,7 Qkv,3 +1,0 gk ( 3 )<br />

Fd(1) = 1,1 qk,h + 0,33 ce(z)qref 50jaar cprob² . cp<br />

Fd(2) = 1,1 Qkh,1 + 0,33 ce(z)qref 50jaar cprob² . cp<br />

Fd(3) = 1,1 Qkh,2 + 0,33 ce(z)qref 50jaar cprob² . cp<br />

Fd(4) = 1,1 Qkv,3 +1,1 gk<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) ( 1 ) ( 1 ) ( 3 )<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) Ed(w) ≤ Xd / γM ( 2 ) Ed(w) ≤ Xd / γM ( 2 ) ( 3 )<br />

( 1 ) Deze wor<strong>de</strong>n gewoonlijk enkel in <strong>de</strong> UGT berekend. Indien nodig, moet <strong>het</strong> gebruiksgeschiktheidscriterium <strong>van</strong> <strong>de</strong> gebruiksgrenstoestand bepaald wor<strong>de</strong>n,<br />

rekening hou<strong>de</strong>nd met <strong>de</strong> <strong>ontwerp</strong>situatie en/of <strong>de</strong> materialen.<br />

( 2 ) Ed vertegenwoordigt <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> belastingscombinatie.<br />

( 3 ) Wanneer <strong>de</strong> <strong>op</strong>spanning <strong>van</strong> <strong>de</strong> dwarsregel <strong>op</strong> <strong>het</strong> vulelement toegelaten is, moet <strong>de</strong> stabiliteit <strong>van</strong> <strong>het</strong> vulelement gecontroleerd wor<strong>de</strong>n on<strong>de</strong>r <strong>de</strong> verticale<br />

belastingen Fd(4).<br />

( 4 ) Uitsluitend <strong>van</strong> toepassing <strong>op</strong> <strong>het</strong> vulelement wanneer er geen leuning of dwarsregel aanwezig is <strong>op</strong> <strong>de</strong> beschermingshoogte (situatie uit § 4.4.2.5.4.2 en<br />

afbeelding 45).<br />

Tabel 25 Bepaling <strong>van</strong> <strong>de</strong> gecombineer<strong>de</strong> belasting veroorzaakt door <strong>de</strong> borstwering, <strong>het</strong> eigengewicht en <strong>de</strong> wind Fd(Ab, gk, w) <strong>op</strong> gevels<br />

(vervolg).<br />

86


4.6.3. Geval <strong>van</strong> daken en hellen<strong>de</strong> gevels<br />

In <strong>de</strong> volgen<strong>de</strong> paragrafen wor<strong>de</strong>n <strong>de</strong> vervormingscriteria zowel uitgedrukt voor een belasting<br />

evenwijdig met <strong>het</strong> beglazingsvlak (y//) als voor een belasting loodrecht <strong>op</strong> <strong>het</strong> beglazingsvlak (y┴)<br />

(afbeelding 56).<br />

θ°<br />

Afbeelding 56 Aanduiding <strong>van</strong> <strong>de</strong> vervormingen <strong>van</strong> een hellen<strong>de</strong> gevel.<br />

Om <strong>de</strong> resulteren<strong>de</strong> belastingen evenwijdig met (E//) en loodrecht <strong>op</strong> (E┴) <strong>het</strong> bereken<strong>de</strong> element te<br />

kunnen bekomen, dient men <strong>de</strong> verschillen<strong>de</strong> belastingen (eigengewicht, wind, sneeuw,<br />

borstweringsfunctie, zie § 4.5) te ontbin<strong>de</strong>n.<br />

4.6.3.1. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong> wind en <strong>het</strong><br />

eigengewicht Fd(w,gk)<br />

Gelet <strong>op</strong> <strong>de</strong> aanwezigheid <strong>van</strong> w (zie § 4.1) en gk (zie § 4.2), en rekening hou<strong>de</strong>nd met <strong>de</strong><br />

verschillen<strong>de</strong> coëfficiënten voor <strong>de</strong> grenstoestan<strong>de</strong>n, wordt <strong>de</strong> belasting Fd(g,w) :<br />

− in <strong>de</strong> gebruiksgrenstoestand :<br />

Fd (g,w) = gk + ψ 1.w<br />

Fd (g,w) = gk + ψ 1. ce(z)qref 50jaar cprob² . cp<br />

− in <strong>de</strong> uiterste grenstoestand :<br />

Fd (g,w) = γG .gk + γQ .w<br />

E┴<br />

y//<br />

E//<br />

y┴<br />

Fd (g,w) = γG gk + γQ. ce(z)qref 50jaar cprob² . cp<br />

De rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong> wind en <strong>het</strong> eigengewicht<br />

Fd(g,w) evenals <strong>de</strong> criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n zijn <strong>op</strong>genomen in tabel 26.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

E┴<br />

E//<br />

y┴<br />

87


Parameters<br />

Hoofdconstructie<br />

(veranda’s,<br />

categorie 3)<br />

Verankering <strong>van</strong> <strong>de</strong> secundaire<br />

constructie<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

88<br />

Secundaire constructie<br />

Partiële coëfficiënt voor <strong>het</strong> eigengewicht en <strong>de</strong> γG γQ γG,sup γG,inf γQ γG,sup γG,inf γQ<br />

wind - NBN EN 1990 ANB tabellen A1.2 (B) 1,35 1,5 1,20 1 1,35 1,15 1 1,25<br />

Begelei<strong>de</strong>n<strong>de</strong> coëfficiënt voor <strong>de</strong> frequente<br />

belastingen ψ 1 (wind)<br />

– 0,90 0,90<br />

Terugkeerperio<strong>de</strong> <strong>van</strong> <strong>de</strong> wind cprob² cprob² = 1 50 jaar - cprob² = 1 50 jaar - cprob² = 1<br />

Waar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht en <strong>de</strong> wind<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) ( 3 )<br />

Fd(g,w) = gk + ψ 1.ce(z)qref 50jaar cprob². cp<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) ( 3 ) : meest<br />

ongunstige combinatie<br />

Fd,1(g,w) = γG,sup .gk + γQ. ce(z)qref 50jaar cprob² . cp<br />

Fd,2(g,w) = γG,inf .gk + γQ. ce(z)qref 50jaar cprob² . cp<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

Uiterste grenstoestan<strong>de</strong>n (UGT)<br />

Zie<br />

Euroco<strong>de</strong>s<br />

en normen<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Zie<br />

Euroco<strong>de</strong>s<br />

en normen<br />

Fd(g,w) = gk + 0,9 ce(z)qref 50jaar .cp<br />

Fd,1(g,w) = 1,20 gk + 1,35 ce(z)qref 50jaar . cp<br />

Fd,2(g,w) = 1,00 gk + 1,35 ce(z)qref 50jaar . cp<br />

( 2 ) y┴ ≤ L/250 ( 4 )<br />

y// = 1/500 of 3 mm ( 5 )<br />

Fd(g,w) = gk + 0,9 ce(z)qref 50jaar cp<br />

Fd,1(g,w) = 1,15 gk + 1,25 ce(z)qref 50jaar . cp<br />

Fd,2(g,w) = 1,00 gk + 1,25 ce(z)qref 50jaar . cp<br />

Dakvensters en<br />

Lichte structuren en veranda’s<br />

veranda’s (categorie 1)<br />

(categorie 2)<br />

Vervorming voor <strong>de</strong> stijlen en <strong>de</strong> kepers ( 6 )<br />

y┴ ≤ L/250 indien L ≤ 3,5 m<br />

y┴ ≤ 4 + L/330 indien 3,5 m < L < 7,5 m<br />

y┴ ≤ L/275 indien L ≥ 7,5 m ( 4 )<br />

y// = 1/500 of ≤ 3 mm ( 5 )<br />

Ed(g,w) ≤ Xd /γM ( 1 ) Geen controle Ed(g,w) ≤ Xd /γM ( 1 ) ( 5 )<br />

( 1 ) E d vertegenwoordigt <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>het</strong> eigengewicht en <strong>de</strong> wind.<br />

( 2 ) De verankeringen wor<strong>de</strong>n gewoonlijk enkel berekend in <strong>de</strong> uiterste grenstoestand. Indien nodig, moet <strong>het</strong> gebruiksgeschiktheidscriterium <strong>van</strong> <strong>de</strong> gebruiksgrenstoestand bepaald wor<strong>de</strong>n, rekening hou<strong>de</strong>nd met <strong>de</strong><br />

<strong>ontwerp</strong>situatie. In bepaal<strong>de</strong> gevel<strong>ontwerp</strong>en wordt een on<strong>de</strong>rscheid gemaakt tussen verankeringen die uitsluitend in staat zijn om <strong>het</strong> eigengewicht <strong>op</strong> te nemen en <strong>de</strong>ze die uitsluitend bestemd zijn om <strong>de</strong><br />

windbelastingen <strong>op</strong> te nemen. In voorkomend geval wordt enkel <strong>de</strong> uitgeoefen<strong>de</strong> belasting in aanmerking genomen en wordt <strong>de</strong> an<strong>de</strong>re niet beschouwd.<br />

( 3 ) Indien een veran<strong>de</strong>rlijke belasting een gunstig effect heeft (vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> resultante F d), moet <strong>de</strong> belastingscombinatie waarin <strong>de</strong>ze veran<strong>de</strong>rlijke belasting gelijk is aan nul eveneens in aanmerking genomen<br />

wor<strong>de</strong>n.<br />

( 4 ) Dit criterium kan verstrengd wor<strong>de</strong>n om een eventuele waterstagnatie te voorkomen.<br />

( 5 ) Het criterium y // = 1/500 of 3 mm is ook <strong>van</strong> toepassing <strong>op</strong> <strong>de</strong> dakrand (dakgoot), als maximale vervorming tussen kolommen. Indien <strong>het</strong> vulpaneel niet in staat is <strong>de</strong> belasting <strong>op</strong> te nemen, geldt dit<br />

vervormingscriterium voor <strong>de</strong> eventuele dwarsregel on<strong>de</strong>r <strong>de</strong> blijven<strong>de</strong> component <strong>van</strong> F d = g k. Het criterium kan aangepast wor<strong>de</strong>n naargelang <strong>van</strong> <strong>de</strong> maximaal toegelaten vervorming, zon<strong>de</strong>r <strong>het</strong> vulpaneel te<br />

raken. Wanneer <strong>de</strong> <strong>op</strong>spanning <strong>van</strong> <strong>de</strong> dwarsregel <strong>op</strong> <strong>het</strong> vulelement toegelaten is, moet <strong>de</strong> stabiliteit <strong>van</strong> <strong>het</strong> vulelement gecontroleerd wor<strong>de</strong>n (zie tabel 27). Indien nodig, dient men een voldoen<strong>de</strong> ruimte te laten<br />

voor <strong>de</strong> drainering en <strong>de</strong> ventilatie.<br />

( 6 ) Het voorgestel<strong>de</strong> vervormingscriterium kan aangepast wor<strong>de</strong>n naargelang <strong>van</strong> <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n (materialen, helling, drainage, …)<br />

Tabel 26 Bepaling <strong>van</strong> <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht en <strong>de</strong> wind Fd(g,w) <strong>op</strong> hellen<strong>de</strong> schrijnwerkelementen (1).


Parameters<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

Verlijming <strong>van</strong> <strong>het</strong> SGG ( 2 )<br />

en verankering <strong>van</strong> <strong>de</strong> vulelementen<br />

89<br />

Vulelementen<br />

Partiële coëfficiënt voor <strong>het</strong> eigengewicht en <strong>de</strong> wind<br />

γG<br />

1,1<br />

γQ<br />

1,1<br />

γG<br />

1,1<br />

γQ<br />

1,1<br />

Begelei<strong>de</strong>n<strong>de</strong> coëfficiënt voor <strong>de</strong> frequente belastingen ψ 1 (wind) - 0,90<br />

Terugkeerperio<strong>de</strong> voor <strong>de</strong> wind 25 jaar - cprob² = 0,92 25 jaar - cprob² = 0,92<br />

Waar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht en <strong>de</strong> wind<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) ( 5 )<br />

Fd(g,w) = gk +ψ 1. ce(z)qref 50jaar cprob² . cp<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) ( 5 ) :<br />

meest ongunstige combinatie<br />

Fd,1 (g,w) = γG,sup .gk + γQ. ce(z)qref 50jaar cprob² . cp<br />

Fd,2 (g,w) = γG,inf .gk + γQ. ce(z)qref 50jaar cprob² . cp<br />

-<br />

Fd,1 (g,w) = 1,1.gk + 1,01 ce(z)qref 50jaar cp<br />

Fd,2 (g,w) = 1,0.gk + 1,01 ce(z)qref 50jaar cp<br />

Fd (g,w) = gk + 0,83.ce(z)qref 50jaar .cp<br />

-<br />

Fd,1 (g,w) = 1,1.gk + 1,01 ce(z)qref 50jaar cp<br />

Fd,2 (g,w) = 1,0.gk + 1,01 ce(z)qref 50jaar cp<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) - Vervorming of belasting ( 3 ) ( 4 )<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) Ed(g,w) ≤ Xd /γM ( 2 ) Ed(g,w) ≤ Xd /γM ( 1 ) ( 4 )<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>het</strong> eigengewicht en <strong>de</strong> wind.<br />

( 2 ) Voor <strong>de</strong> dimensionering en <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG (zie bijlage B, ETAG 002) :<br />

− «hc» on<strong>de</strong>r trek : wanneer <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG on<strong>de</strong>rworpen is aan een blijven<strong>de</strong> trekkracht, dient men veiligheidsvoorzieningen aan te wen<strong>de</strong>n die zodanig<br />

berekend zijn dat ze in staat zijn <strong>de</strong> resultante E┴ <strong>van</strong> <strong>de</strong> belastingscombinatie Fd,(g,w) <strong>op</strong> te nemen<br />

− «hc» on<strong>de</strong>r druk : <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG is in staat een beperkte blijven<strong>de</strong> druk <strong>op</strong> te nemen, die <strong>op</strong>gegeven wordt door <strong>de</strong> producent. Indien <strong>de</strong> druk groter is,<br />

moet een gepaste <strong>op</strong>spanning wor<strong>de</strong>n voorzien om <strong>de</strong> drukresultante E┴ <strong>van</strong> <strong>de</strong> belastingscombinatie Fd(g,w) over te brengen <strong>op</strong> <strong>het</strong> verlijmingska<strong>de</strong>r.<br />

− «e» : in <strong>het</strong> geval <strong>van</strong> schrijnwerk dat uitgerust is met voorzieningen om <strong>de</strong> afschuifcomponent <strong>van</strong> <strong>het</strong> eigengewicht <strong>op</strong> te nemen, wordt «e» zodanig gedimensioneerd<br />

dat <strong>de</strong> effecten tengevolge <strong>van</strong> <strong>het</strong> temperatuurverschil kunnen wor<strong>de</strong>n <strong>op</strong>ge<strong>van</strong>gen. Bij gebrek aan een <strong>de</strong>rgelijke voorziening, wordt «e» zodanig gedimensioneerd dat<br />

<strong>de</strong> afschuifcomponent <strong>van</strong> <strong>het</strong> eigengewicht (1,1 gk), gecombineerd met <strong>de</strong> belasting tengevolge <strong>van</strong> <strong>het</strong> temperatuurverschil, kan wor<strong>de</strong>n <strong>op</strong>ge<strong>van</strong>gen.<br />

( 3 ) Vervorming en/of belasting naargelang <strong>van</strong> <strong>de</strong> productspecificaties.<br />

( 4 ) Wanneer <strong>de</strong> <strong>op</strong>spanning <strong>van</strong> <strong>de</strong> dwarsregel <strong>op</strong> <strong>het</strong> vulelement toegelaten is, moet <strong>de</strong> stabiliteit <strong>van</strong> <strong>het</strong> vulelement gecontroleerd wor<strong>de</strong>n on<strong>de</strong>r <strong>de</strong> belasting E// <strong>van</strong> <strong>de</strong><br />

rekenwaar<strong>de</strong>n Fd.<br />

( 5 ) Indien een veran<strong>de</strong>rlijke belasting een gunstig effect heeft (vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> resultante Fd), moet <strong>de</strong> belastingscombinatie waarin <strong>de</strong>ze veran<strong>de</strong>rlijke belasting gelijk is<br />

aan nul eveneens in aanmerking genomen wor<strong>de</strong>n.<br />

Tabel 27 Bepaling <strong>van</strong> <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht en <strong>de</strong> wind Fd(g,w) <strong>op</strong> hellen<strong>de</strong> schrijnwerkelementen (2).


4.6.3.2. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door sneeuw en <strong>het</strong><br />

eigengewicht Fd(gk, sk)<br />

De belastingen gk en sk wor<strong>de</strong>n <strong>op</strong>gegeven ten aanzien <strong>van</strong> <strong>de</strong> verticale. In geval <strong>van</strong> een hellend<br />

bouwwerk dient men <strong>de</strong> belastingen te ontbin<strong>de</strong>n volgens <strong>de</strong> helling <strong>van</strong> <strong>de</strong> as, aan <strong>de</strong> hand waar<strong>van</strong><br />

<strong>de</strong> berekening wordt uitgevoerd (E// en E┴, zie afbeelding 56). Gelet <strong>op</strong> <strong>de</strong> aanwezigheid <strong>van</strong> sk (zie<br />

§ 4.3) en gk (zie § 4.2), en rekening hou<strong>de</strong>nd met <strong>de</strong> verschillen<strong>de</strong> coëfficiënten voor <strong>de</strong><br />

grenstoestan<strong>de</strong>n, wordt <strong>de</strong> belasting Fd(g,s) :<br />

− in <strong>de</strong> gebruiksgrenstoestand : Fd(g,s) = gk + rsk.μ i .sk<br />

− in <strong>de</strong> uiterste grenstoestand : Fd(g,s) = γG .gk + rsk.μi .γQ .sk.<br />

De rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door sneeuw en <strong>het</strong> eigengewicht<br />

Fd(g,s) evenals <strong>de</strong> criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n zijn <strong>op</strong>genomen in <strong>de</strong> tabellen 28 en 29.<br />

4.6.3.3. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong> wind, sneeuw<br />

en <strong>het</strong> eigengewicht Fd(gk, w, sk)<br />

De belastingen gk en sk wor<strong>de</strong>n <strong>op</strong>gegeven ten aanzien <strong>van</strong> <strong>de</strong> verticale, terwijl <strong>de</strong> windbelasting<br />

loodrecht <strong>op</strong> <strong>het</strong> vlak <strong>van</strong> <strong>het</strong> hellen<strong>de</strong> schrijnwerk aangrijpt. De belastingen moeten ontbon<strong>de</strong>n<br />

wor<strong>de</strong>n volgens <strong>de</strong> helling <strong>van</strong> <strong>de</strong> as, aan <strong>de</strong> hand waar<strong>van</strong> <strong>de</strong> berekening wordt uitgevoerd (E// en<br />

E┴, zie afbeelding 56).<br />

Gelet <strong>op</strong> <strong>de</strong> aanwezigheid <strong>van</strong> sk (zie § 4.3), gk (zie § 4.2) en w (zie § 4.1), en rekening hou<strong>de</strong>nd met<br />

<strong>de</strong> verschillen<strong>de</strong> coëfficiënten voor <strong>de</strong> grenstoestan<strong>de</strong>n, moet <strong>de</strong> meest ongunstige <strong>van</strong> <strong>de</strong> volgen<strong>de</strong><br />

twee combinaties in aanmerking genomen wor<strong>de</strong>n :<br />

− ofwel is <strong>de</strong> dominante veran<strong>de</strong>rlijke belasting <strong>de</strong> sneeuw en <strong>de</strong> begelei<strong>de</strong>n<strong>de</strong> belasting <strong>de</strong> wind :<br />

Fd(C1) = rekenwaar<strong>de</strong> voor <strong>de</strong> gecombineer<strong>de</strong> belasting door <strong>het</strong> eigengewicht, sneeuw en <strong>de</strong> wind<br />

− ofwel is <strong>de</strong> dominante veran<strong>de</strong>rlijke belasting <strong>de</strong> wind en <strong>de</strong> begelei<strong>de</strong>n<strong>de</strong> belasting <strong>de</strong> sneeuw :<br />

Fd(C2) = rekenwaar<strong>de</strong> voor <strong>de</strong> gecombineer<strong>de</strong> belasting door <strong>het</strong> eigengewicht, <strong>de</strong> wind en sneeuw.<br />

In <strong>de</strong> gebruiksgrenstoestand<br />

De frequente combinatie is <strong>van</strong> toepassing (omkeerbaarheid <strong>van</strong> <strong>het</strong> grenstoestandscriterium) :<br />

− Fd (C1) : Fd (C1) = gk + ψ1. rsk . μ i . sk + ψ2 .w<br />

Fd (C1) = gk + ψ1. rsk . μ i sk + ψ2. ce(z)qref 50jar cprob² . cp<br />

in dit geval is ψ2 = 0 (zie ANB NBN EN 1990); dit belastingsgeval werd dus reeds besproken<br />

− Fd (C2) : Fd (C2) = gk + ψ1.w + ψ2 rsk. μ i .sk<br />

Fd (C2) = gk + ψ1 . ce(z)qref 50jaar cprob² . cp + ψ2. rsk. μ i .sk<br />

in dit geval is ψ2 = 0 (zie ANB NBN EN 1990)<br />

Fd (C2) = gk + ψ1 . ce(z)qref 50jaar cprob² . cp<br />

Dit belastingsgeval werd reeds besproken.<br />

De controle <strong>van</strong> <strong>de</strong> gebruiksgrenstoestand bij <strong>de</strong> belastingscombinatie veroorzaakt door <strong>het</strong><br />

eigengewicht, <strong>de</strong> wind en sneeuw moet dus gebeuren volgens <strong>de</strong> belastingen en <strong>de</strong> criteria voor <strong>de</strong><br />

gebruiksgrenstoestand, <strong>op</strong>genomen in § 4.6.3.1 en § 4.6.3.2.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

90


Parameters<br />

Partiële coëfficiënten voor <strong>het</strong><br />

Hoofdconstructie<br />

(veranda’s,<br />

categorie 3)<br />

Verankering <strong>van</strong> <strong>de</strong> secundaire<br />

constructie<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

91<br />

Secundaire constructie<br />

γG γQ γG γQ rsk γG γQ rsk<br />

eigengewicht en sneeuw 1,35 1,5 1,20 1,35 1 1,15 1,25 1<br />

Waar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht en sneeuw<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) ( 5 )<br />

Fd(g,s) = gk + rsk . μi . sk<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) ( 5 )<br />

Fd(g,s) = γG . gk + γQ . rsk . μ i . sk<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

Zie<br />

Euroco<strong>de</strong>s en<br />

normen<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Zie<br />

Euroco<strong>de</strong>s en<br />

normen<br />

Fd(g,s) = gk + μi.sk ( 4 )<br />

Fd(g,s) = 1,2.gk + 1,35.μi.sk<br />

( 2 )<br />

Fd(g,s) = gk + μi.sk<br />

Fd(g,s) = 1,15.gk + 1,25.μi.sk<br />

Dakvensters en Lichte structuren en veranda’s (categorie<br />

veranda’s (categorie 1)<br />

2)<br />

Vervorming <strong>van</strong> <strong>de</strong> stijlen (kepers) en <strong>de</strong> dwarsregels ( 6 )<br />

y┴ ≤ L/250 ( 4 )<br />

y// = 1/500 of 3 mm ( 3 )<br />

y┴ ≤ L/250 indien L ≤ 3,5 m<br />

y┴ ≤ 4 + L/330 indien 3,5 m < L < 7,5 m<br />

y┴ ≤ L/275 indien L ≥ 7,5 m ( 4 )<br />

y// = 1/500 of ≤ 3 mm ( 3 )<br />

Uiterste grenstoestan<strong>de</strong>n (UGT)<br />

Ed(g,s) ≤ Xd /γm ( 1 ) Geen controle Ed(g,s) ≤ Xd /γm ( 1 )<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> belastingscombinatie.<br />

( 2 ) De verankeringen wor<strong>de</strong>n gewoonlijk enkel berekend in <strong>de</strong> uiterste grenstoestand. Indien nodig, moet <strong>het</strong> gebruiksgeschiktheidscriterium <strong>van</strong> <strong>de</strong> gebruiksgrenstoestand bepaald<br />

wor<strong>de</strong>n, rekening hou<strong>de</strong>nd met <strong>de</strong> <strong>ontwerp</strong>situatie.<br />

( 3 ) Het criterium y// = 1/500 of 3 mm is ook <strong>van</strong> toepassing <strong>op</strong> <strong>de</strong> dakrand (dakgoot), als maximale vervorming tussen twee kolommen.<br />

Indien <strong>het</strong> vulpaneel niet in staat is <strong>de</strong> belasting <strong>op</strong> te nemen, geldt dit vervormingscriterium tevens voor <strong>de</strong> eventuele dwarsregel on<strong>de</strong>r <strong>de</strong> blijven<strong>de</strong> component <strong>van</strong> Fd = gk. Het<br />

criterium kan aangepast wor<strong>de</strong>n naargelang <strong>van</strong> <strong>de</strong> maximaal toegelaten vervorming, zon<strong>de</strong>r <strong>het</strong> vulpaneel te raken. Wanneer <strong>de</strong> <strong>op</strong>spanning <strong>van</strong> <strong>de</strong> dwarsregel <strong>op</strong> <strong>het</strong> vulelement<br />

toegelaten is, moet <strong>de</strong> stabiliteit <strong>van</strong> <strong>het</strong> vulelement gecontroleerd wor<strong>de</strong>n (zie tabel 29). Indien nodig, dient men een voldoen<strong>de</strong> ruimte te laten voor <strong>de</strong> drainering en <strong>de</strong> ventilatie.<br />

( 4 ) Behou<strong>de</strong>ns an<strong>de</strong>rslui<strong>de</strong>n<strong>de</strong> specificaties voor <strong>het</strong> bouwwerk of <strong>de</strong> materialen (constructies, vulelementen, …).<br />

( 5 ) Indien een veran<strong>de</strong>rlijke belasting een gunstig effect heeft (vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> resultante Fd), moet <strong>de</strong> belastingscombinatie waarin <strong>de</strong>ze veran<strong>de</strong>rlijke belasting gelijk is aan nul<br />

eveneens in aanmerking genomen wor<strong>de</strong>n (zie § 4.6.1).<br />

( 6 ) Het voorgestel<strong>de</strong> vervormingscriterium kan aangepast wor<strong>de</strong>n naargelang <strong>van</strong> <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n (materialen, helling, drainering, …).<br />

Tabel 28 Bepaling <strong>van</strong> <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht en sneeuw Fd (g, s) <strong>op</strong> hellen<strong>de</strong> schrijnwerkelementen (1).


Parameters<br />

Verlijming <strong>van</strong> <strong>het</strong> SGG en verankering <strong>van</strong> <strong>de</strong><br />

vulelementen<br />

Vulelementen<br />

Partiële coëfficiënten voor <strong>het</strong><br />

γG γQ rsk γG γQ rsk<br />

eigengewicht en sneeuw 1,1 1,1 0,88 1,1 1,1 0,88<br />

Waar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht en sneeuw<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) ( 5 )<br />

Fd(g,s) = gk + rsk . μi . sk<br />

–<br />

Fd(g, s)= gk +0,88.μisk<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) ( 5 )<br />

Fd(g,s) = γG . gk + γQ rsk . μi . sk<br />

Fd(g, s)= 1,1.gk + 0,965.μi.sk ( 2 )<br />

Tabel 29 Bepaling <strong>van</strong> <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht en sneeuw Fd(g, s) <strong>op</strong> hellen<strong>de</strong><br />

schrijnwerkelementen (2).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

92<br />

Fd(g, s) = 1,1 gk + 0,965.μi.sk<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) – Vervorming of belasting ( 3 ) ( 4 )<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) Ed(g, s) ≤ Xd /γm ( 1 ) Ed(g, s) ≤ Xd /γm ( 1 ) ( 4 )<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> belastingscombinatie, naargelang <strong>van</strong> <strong>de</strong><br />

<strong>ontwerp</strong>situatie.<br />

( 2 ) Voor <strong>de</strong> dimensionering en <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG (zie bijlage B, ETAG 002) :<br />

− «hc» on<strong>de</strong>r trek : wanneer <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG on<strong>de</strong>rworpen is aan een blijven<strong>de</strong> trekkracht, dient men veiligheidsvoorzieningen aan<br />

te wen<strong>de</strong>n die zodanig berekend zijn dat ze in staat zijn <strong>de</strong> resultante E// <strong>van</strong> <strong>de</strong> belastingscombinatie Fd,(g, w) <strong>op</strong> te nemen<br />

− «hc» on<strong>de</strong>r druk : <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG is in staat een beperkte blijven<strong>de</strong> druk <strong>op</strong> te nemen, die <strong>op</strong>gegeven wordt door <strong>de</strong> producent.<br />

Indien <strong>de</strong> druk groter is, moet een gepaste <strong>op</strong>spanning wor<strong>de</strong>n voorzien om <strong>de</strong> drukresultante E┴ <strong>van</strong> <strong>de</strong> belastingscombinatie Fd (g, s) over<br />

te brengen <strong>op</strong> <strong>het</strong> verlijmingska<strong>de</strong>r<br />

− «e» : in <strong>het</strong> geval <strong>van</strong> schrijnwerk dat uitgerust is met een voorziening om <strong>de</strong> afschuifcomponent <strong>van</strong> <strong>het</strong> eigengewicht <strong>op</strong> te nemen, wordt<br />

«e» zodanig gedimensioneerd dat <strong>de</strong> afschuifcomponent <strong>van</strong> <strong>het</strong> eigengewicht (1,1 gk), gecombineerd met <strong>de</strong> belasting tengevolge <strong>van</strong> <strong>het</strong><br />

temperatuurverschil, kan wor<strong>de</strong>n <strong>op</strong>ge<strong>van</strong>gen.<br />

( 3 ) Vervorming en/of belasting naargelang <strong>van</strong> <strong>de</strong> productspecificaties.<br />

( 4 ) Wanneer <strong>de</strong> <strong>op</strong>spanning <strong>van</strong> <strong>de</strong> dwarsregel <strong>op</strong> <strong>het</strong> vulelement toegelaten is, moet <strong>de</strong> stabiliteit <strong>van</strong> <strong>het</strong> vulelement gecontroleerd wor<strong>de</strong>n on<strong>de</strong>r <strong>de</strong><br />

belasting E// <strong>van</strong> <strong>de</strong> rekenwaar<strong>de</strong>n Fd.<br />

( 5 ) Indien een veran<strong>de</strong>rlijke belasting een gunstig effect heeft (vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> resultante Fd), moet <strong>de</strong> belastingscombinatie waarin <strong>de</strong>ze<br />

veran<strong>de</strong>rlijke belasting gelijk is aan nul eveneens in aanmerking genomen wor<strong>de</strong>n.


In <strong>de</strong> uiterste grenstoestand<br />

De fundamentele combinatie is <strong>van</strong> toepassing. In dit geval is ψ0 = 0,3 (zie ANB NBN EN 1990,<br />

tabel A 1.1, nota (3)) en<br />

− Fd (C1) : Fd (C1) = γG .gk + γQ . rsk. μi .sk + γQ ψ0 .w<br />

Fd (C1) = γG .gk + γQ . rsk. μi.sk + γQ ψ0 .ce(z)qref 50jaar cprob² . cp<br />

− Fd (C2) : Fd (C2) = γG gk + γQ .w+ γQ .ψ0 . rsk. μi.sk<br />

waarbij<br />

Fd (C2) = γG .gk + γQ ce(z)qref 50jaar cprob² . cp + γQ ψ0 . rsk. μ i.sk<br />

− Fd(X) : <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> belastingscombinatie<br />

− γQ : <strong>de</strong> partiële coëfficiënt voor <strong>de</strong> wind of <strong>de</strong> sneeuw<br />

− ψ0 : <strong>de</strong> coëfficiënt voor <strong>de</strong> combinatiewaar<strong>de</strong> voor <strong>de</strong> wind of <strong>de</strong> sneeuw<br />

− ψ1 : <strong>de</strong> begelei<strong>de</strong>n<strong>de</strong> coëfficiënt voor <strong>de</strong> windbelasting<br />

− γM : <strong>de</strong> partiële coëfficiënt voor <strong>de</strong> materialen (zie hoofdstuk 5)<br />

− Xd : <strong>de</strong> rekenwaar<strong>de</strong> voor <strong>de</strong> materialen (zie hoofdstuk 5).<br />

Het heeft geen zin om rekening te hou<strong>de</strong>n met <strong>de</strong> wind in on<strong>de</strong>rdruk. In voorkomend geval zou<br />

<strong>het</strong> eigengewicht immers een gunstig effect hebben (γG,inf = 1), net zoals <strong>de</strong> sneeuw (γQ,inf = 0),<br />

en komen we terug tot <strong>het</strong> geval Fd(g,w) dat hiervoor reeds geanalyseerd werd.<br />

De rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong> wind, <strong>het</strong> eigengewicht en<br />

<strong>de</strong> sneeuw Fd (g, w, s) evenals <strong>de</strong> criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n zijn <strong>op</strong>genomen in <strong>de</strong><br />

tabellen 30 tot 32.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

93


Parameters<br />

Partiële coëfficiënten voor <strong>het</strong> eigengewicht, <strong>de</strong> wind en sneeuw<br />

Coëfficiënt die <strong>de</strong> combinatiewaar<strong>de</strong> voor een veran<strong>de</strong>rlijke<br />

belasting ψ0 <strong>de</strong>fineert<br />

Terugkeerperio<strong>de</strong> voor <strong>de</strong> wind cprob²<br />

Terugkeerperio<strong>de</strong> voor <strong>de</strong> sneeuw rsk<br />

Uiterste grenstoestan<strong>de</strong>n (UGT)<br />

Fd(C1) = γG . gk + γQ . rsk. μi.sk + γQ ψ0 . ce(z)qref 50jaar cprob² . cp<br />

Fd(C2) = γG . gk + γQ ce(z)qref 50jaar cprob² . cp + γQ. ψ0 . rsk.μ i.sk<br />

Hoofdconstructie<br />

(veranda’s,<br />

categorie 3)<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

94<br />

Verankering <strong>van</strong> <strong>de</strong> secundaire constructie<br />

γG γQ γG γQ<br />

1,35 1,50 1,20 1,35<br />

– 0,30<br />

50 jaar -<br />

cprob² = 1<br />

50 jaar - rsk<br />

= 1<br />

50 jaar - cprob² = 1<br />

50 jaar - rsk = 1<br />

Waar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht, <strong>de</strong> wind en sneeuw<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

Zie<br />

–<br />

Euroco<strong>de</strong>s<br />

en normen<br />

Fd(C1) = 1,20 gk + 1,35.μi sk + 0,4. ce(z)qref 50jaar cp ( 2 )<br />

Fd(C2) = 1,20. gk + 1,35. ce(z)qref 50jaar . cp + 0,4 μi.sk ( 2 )<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Zie<br />

–<br />

Uiterste grenstoestan<strong>de</strong>n (UGT)<br />

Euroco<strong>de</strong>s<br />

en normen<br />

Ed(C1) ≤ Xd /γM - Ed(C2) ≤ Xd /γM ( 1 )<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> belastingscombinatie.<br />

( 2 ) Indien een veran<strong>de</strong>rlijke belasting een gunstig effect heeft (vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> resultante Fd), moet <strong>de</strong> belastingscombinatie waarin <strong>de</strong>ze<br />

veran<strong>de</strong>rlijke belasting gelijk is aan nul eveneens in aanmerking genomen wor<strong>de</strong>n (zie § 4.6).<br />

Tabel 30 Bepaling <strong>van</strong> <strong>de</strong> gecombineer<strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht, <strong>de</strong> wind en sneeuw Fd(C1), Fd(C2) <strong>op</strong><br />

hellen<strong>de</strong> schrijnwerkelementen (1).


Parameters Secundaire constructie<br />

Partiële coëfficiënten voor <strong>het</strong> eigengewicht, <strong>de</strong> wind en<br />

γG<br />

γQ<br />

sneeuw 1,15 1,25<br />

Coëfficiënt die <strong>de</strong> combinatiewaar<strong>de</strong> voor een veran<strong>de</strong>rlijke<br />

belasting ψ0 <strong>de</strong>fineert<br />

0,30<br />

Terugkeerperio<strong>de</strong> voor <strong>de</strong> wind cprob² 50 jaar - cprob² = 1<br />

Terugkeerperio<strong>de</strong> voor <strong>de</strong> sneeuw rsk<br />

50 jaar - rsk = 1<br />

Waar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht, <strong>de</strong> wind en sneeuw<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) –<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) ( 2 )<br />

Fd(C1) = γG . gk + γQ . rsk. μi.sk + γQ ψ0 . ce(z)qref 50jaar cprob² . cp<br />

Fd(C2) = γG . gk + γQ ce(z)qref 50jaar cprob² . cp + γQ.ψ0 . rsk.μ i.sk<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

Fd(C1) = 1,15. gk + 1,25. μi . sk + 0,375. ce(z)qref 50jaar cp<br />

Fd(C2) = 1,15. gk + 1,25. ce(z)qref 50jaar cp + 0,375 μi .sk<br />

Dakvensters en veranda’s Lichte structuren en<br />

(categorie 1)<br />

veranda’s (categorie 2)<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) – –<br />

Ed(C1) ≤ Xd /γM<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) Geen controle<br />

Ed(C2) ≤ Xd /γM ( 1 )<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> belastingscombinatie.<br />

( 2 ) Indien een veran<strong>de</strong>rlijke belasting een gunstig effect heeft (vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> resultante Fd), moet <strong>de</strong> belastingscombinatie waarin <strong>de</strong>ze<br />

veran<strong>de</strong>rlijke belasting gelijk is aan nul eveneens in aanmerking genomen wor<strong>de</strong>n (zie § 4.6.1).<br />

Tabel 31 Bepaling <strong>van</strong> <strong>de</strong> gecombineer<strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht, <strong>de</strong> wind en sneeuw Fd(C1),<br />

Fd(C2) <strong>op</strong> hellen<strong>de</strong> schrijnwerkelementen (2).<br />

95


Parameters<br />

Partiële coëfficiënten voor <strong>het</strong> eigengewicht, <strong>de</strong> wind en<br />

Verlijming <strong>van</strong> <strong>het</strong> SGG ( 2 ) en verankering <strong>van</strong><br />

<strong>de</strong> vulelementen<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

96<br />

Vulelementen<br />

γG γQ γG γQ<br />

sneeuw 1,1 1,1 1,1 1,1<br />

Combinatiewaar<strong>de</strong> voor een veran<strong>de</strong>rlijke belasting ψ0 0,30 0,30<br />

Terugkeerperio<strong>de</strong> voor <strong>de</strong> wind 25 jaar - cprob² = 0,92 25 jaar - cprob² = 0,92<br />

Terugkeerperio<strong>de</strong> voor <strong>de</strong> sneeuw 25 jaar - rsk = 0,88 25 jaar - rsk = 0,88<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

Waar<strong>de</strong>n voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht, <strong>de</strong> wind en sneeuw<br />

– –<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) ( 3 )<br />

Fd(C1) = γG. gk + γQ . rsk. μi . sk+ γQ . ψ0.ce(z)qref 50jaar cprob² . cp<br />

Fd(C2) = γG .gk + γQ. ce(z)qref 50jaar cprob² . cp + γQ. ψ0. rsk. μi.sk<br />

Fd(C1) = 1,1.gk+0,965.μi .sk + 0,3.ce(z)qref 50jaar .cp<br />

Fd(C2) = 1,1 gk + 1,01 ce(z)qref 50jaar.cp + 0,29 . μi . sk<br />

Fd(C1) = 1,1 gk + 0,965.μi sk + 0,30ce(z)qref 50jaar.cp<br />

Fd(C2) = 1,1 gk + 1,01 ce(z)qref 50jaar.cp + 0,29 μi sk<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) – –<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) Ed(C1) ≤ Xd /γm - Ed(C2) ≤ Xk /γm ( 1 ) Ed(C1) ≤ Xd /γm - Ed(C2) ≤ Xk /γm ( 1 )<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> belastingscombinatie.<br />

( 2 ) Voor <strong>de</strong> dimensionering en <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG (zie bijlage B, ETAG 002) :<br />

− «hc» moet on<strong>de</strong>r trek gedimensioneerd wor<strong>de</strong>n volgens <strong>de</strong> meest ongunstige combinatie tussen Fd (C1) en Fd (C2)<br />

− «hc» on<strong>de</strong>r trek : wanneer <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG on<strong>de</strong>rworpen is aan een blijven<strong>de</strong> trekkracht, dient men veiligheidsvoorzieningen aan te wen<strong>de</strong>n die zodanig berekend<br />

zijn dat ze in staat zijn <strong>de</strong> resultante E┴ <strong>van</strong> <strong>de</strong> belastingscombinatie Fd <strong>op</strong> te nemen<br />

− «hc» on<strong>de</strong>r druk : <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG is in staat om een beperkte blijven<strong>de</strong> druk <strong>op</strong> te nemen, die <strong>op</strong>gegeven wordt door <strong>de</strong> producent. Indien <strong>de</strong> druk groter is, moet<br />

een gepaste <strong>op</strong>spanning wor<strong>de</strong>n voorzien om <strong>de</strong> drukresultante E┴ <strong>van</strong> <strong>de</strong> belastingscombinatie Fd (C) over te brengen <strong>op</strong> <strong>het</strong> verlijmingska<strong>de</strong>r<br />

− «e» : in <strong>het</strong> geval <strong>van</strong> schrijnwerk dat uiterust is met een voorziening om <strong>de</strong> afschuifcomponent <strong>van</strong> <strong>het</strong> eigengewicht <strong>op</strong> te nemen, moet «e» zodanig gedimensioneerd wor<strong>de</strong>n<br />

dat <strong>de</strong> effecten tengevolge <strong>van</strong> <strong>het</strong> temperatuurverschil kunnen wor<strong>de</strong>n <strong>op</strong>ge<strong>van</strong>gen. Bij gebrek aan een <strong>de</strong>rgelijke voorziening, wordt «e» zodanig gedimensioneerd dat <strong>de</strong><br />

afschuifresultante E// <strong>van</strong> <strong>het</strong> eigengewicht en <strong>de</strong> sneeuw, gecombineerd met <strong>de</strong> belasting door <strong>het</strong> temperatuurverschil, kan wor<strong>de</strong>n <strong>op</strong>ge<strong>van</strong>gen.<br />

( 3 ) Indien een veran<strong>de</strong>rlijke belasting een gunstig effect heeft (vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> resultante Fd), moet <strong>de</strong> belastingscombinatie waarin <strong>de</strong>ze veran<strong>de</strong>rlijke belasting gelijk is aan nul<br />

eveneens in aanmerking genomen wor<strong>de</strong>n.<br />

Tabel 32 Bepaling <strong>van</strong> <strong>de</strong> gecombineer<strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht, <strong>de</strong> wind en sneeuw Fd(C1), Fd(C2) <strong>op</strong> hellen<strong>de</strong><br />

schrijnwerkelementen (3).


4.6.3.4. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong><br />

borstweringsfunctie, <strong>het</strong> eigengewicht en <strong>de</strong> wind Fd(Ab, gk, w)<br />

Men dient <strong>de</strong> tabellen 17 tot 19 te consulteren om na te gaan of men voor <strong>de</strong> borstweringsfunctie<br />

<strong>de</strong> statische belastingen (zie § 4.4.2.5.1) in aanmerking moet nemen naargelang <strong>van</strong> <strong>de</strong><br />

gebruikscategorieën. Elke belasting veroorzaakt door <strong>de</strong> borstweringsfunctie (zie tabel 15) wordt<br />

individueel gecombineerd met <strong>de</strong> belastingen veroorzaakt door <strong>het</strong> eigengewicht en <strong>de</strong> wind.<br />

Wanneer een belasting een grote excentriciteit vertoont ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong> as <strong>van</strong> <strong>het</strong> profiel,<br />

dient men rekening te hou<strong>de</strong>n met <strong>de</strong> veroorzaakte torsiemomenten.<br />

Afbeelding 57 Globale voorstelling <strong>van</strong> <strong>de</strong> belastingen veroorzaakt door<br />

<strong>de</strong> borstweringsfunctie en <strong>het</strong> eigengewicht.<br />

4.6.3.4.1. Geval <strong>van</strong> stijlen<br />

De belastingen veroorzaakt door <strong>het</strong> eigengewicht gk, <strong>de</strong> wind w en <strong>de</strong> borstweringsfunctie qk,h,<br />

Qkh,1 en Qkv,3 kunnen ontbon<strong>de</strong>n wor<strong>de</strong>n in componenten evenwijdig met (//) en loodrecht <strong>op</strong> (┴)<br />

<strong>de</strong> gevel. De evenwijdige resultante E// uit zich door een axiale belasting in <strong>de</strong> stijl. De<br />

loodrechte resultante E┴ uit zich door een moment in <strong>de</strong> stijl dat gecontroleerd moet wor<strong>de</strong>n<br />

volgens <strong>de</strong> criteria uit <strong>de</strong> volgen<strong>de</strong> tabellen. De combinatie <strong>van</strong> gk en Qkh,2 hoeft niet<br />

gecontroleerd te wor<strong>de</strong>n.<br />

Geval 1<br />

Geval 2<br />

Geval 3<br />

Afbeelding 58 Combinatie <strong>van</strong> Fd(qk,H, gk ) in <strong>de</strong> stijlen <strong>van</strong> een hellend schrijnwerkelement.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

97


4.6.3.4.2. Geval <strong>van</strong> dwarsregels<br />

De verticale belastingen veroorzaakt door <strong>het</strong> eigengewicht gk, <strong>de</strong> wind w en <strong>de</strong><br />

borstweringsfunctie qk,h, Qkh,1 en Qkv,3 wor<strong>de</strong>n ontbon<strong>de</strong>n in een component evenwijdig met (//)<br />

en loodrecht <strong>op</strong> (┴) <strong>de</strong> gevel. De evenwijdige en loodrechte resultanten uiten zich respectievelijk<br />

door een evenwijdige en een loodrechte buiging. Daarom moeten ze gecontroleerd wor<strong>de</strong>n<br />

volgens <strong>de</strong> criteria uit <strong>de</strong> volgen<strong>de</strong> tabellen.<br />

Afbeelding 59 Combinatie <strong>van</strong> Fd(Qk,v,3, gk, w) in <strong>de</strong> dwarsregels <strong>van</strong> een hellend<br />

schrijnwerkelement.<br />

Afbeelding 60 Belastingscombinatie veroorzaakt door <strong>de</strong> borstweringsfunctie Ah = Fd(qkh) of<br />

Fd(Qkh,1) of Fd(Qkh,2), <strong>het</strong> eigengewicht gk en <strong>de</strong> wind w.<br />

4.6.3.4.3. Geval <strong>van</strong> vulpanelen en hun bevestiging<br />

Wanneer er geen leuning of dwarsregel voorhan<strong>de</strong>n is die in staat is <strong>de</strong> belastingen qk,h, Qkh,1 en<br />

Qkh,2 <strong>op</strong> te nemen, moeten <strong>de</strong>ze belastingen in aanmerking genomen wor<strong>de</strong>n bij <strong>de</strong><br />

dimensionering <strong>van</strong> <strong>de</strong> vulpanelen, voor zover dit aanbevolen wordt in <strong>de</strong> tabellen 17 tot 19 (zie<br />

ook voorbeel<strong>de</strong>n uit <strong>de</strong> afbeeldingen 43, 45 en 47 en uit § 4.4).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

98


4.6.3.4.4. Belastingscombinatie veroorzaakt door <strong>de</strong> borstweringsfunctie, door <strong>het</strong><br />

eigengewicht en <strong>de</strong> wind<br />

Deze belastingscombinatie wordt enkel in aanmerking genomen indien vermeld in <strong>de</strong> tabellen 17<br />

tot 19. Gelet <strong>op</strong> <strong>de</strong> belastingen veroorzaakt door <strong>de</strong> borstweringsfunctie Ab (zie § 4.4), <strong>het</strong><br />

eigengewicht gk (zie § 4.2) en <strong>de</strong> wind w (zie § 4.1), en rekening hou<strong>de</strong>nd met <strong>de</strong> verschillen<strong>de</strong><br />

coëfficiënten voor <strong>de</strong> grenstoestan<strong>de</strong>n, dient men <strong>de</strong> vier rekenwaar<strong>de</strong>n afzon<strong>de</strong>rlijk te<br />

beschouwen :<br />

− in <strong>de</strong> gebruiksgrenstoestand :<br />

Fd(C1) = gk +ψ1.qk,h +ψ2 w<br />

Fd(C2) = gk +ψ1.Qkh,1 +ψ2 w<br />

Fd(C3) = gk +ψ1.Qkh,2 + ψ2 w<br />

Fd(C4) = gk + ψ1.Qkv,3 +ψ2 w<br />

in dit geval mag ψ1 gelijkgesteld wor<strong>de</strong>n aan 0,7 en ψ2 aan 0 (zie ANB NBN EN 1990)<br />

− in <strong>de</strong> uiterste grenstoestand :<br />

Fd(C1) = γG gk + γQ qk,h + ψ0 γQ w<br />

Fd(C2) = γG gk + γQ Qkh,1+ ψ0 γQ w<br />

Fd(C3) = γG gk + γQ Qkh,2+ ψ0 γQ w<br />

Fd(C4) = γG gk + γQ Qkv,3 + ψ0. γQ w<br />

in dit geval mag ψ0 gelijkgesteld wor<strong>de</strong>n aan 0,3 (zie ANB NBN EN 1990).<br />

In <strong>de</strong>ze vergelijkingen is :<br />

− Fd(X) : <strong>de</strong> rekenwaar<strong>de</strong> voor <strong>de</strong> belastingscombinatie<br />

− γQ : <strong>de</strong> partiële coëfficiënt voor <strong>de</strong> wind<br />

− γG : <strong>de</strong> partiële coëfficiënt voor <strong>het</strong> eigengewicht<br />

− ψ0 : <strong>de</strong> begelei<strong>de</strong>n<strong>de</strong> coëfficiënt voor <strong>de</strong> combinatiewaar<strong>de</strong> <strong>van</strong> <strong>de</strong> wind<br />

− ψ1 : <strong>de</strong> begelei<strong>de</strong>n<strong>de</strong> coëfficiënt voor <strong>de</strong> belastingen veroorzaakt door <strong>de</strong> borstweringsfunctie<br />

− ψ2 : <strong>de</strong> begelei<strong>de</strong>n<strong>de</strong> coëfficiënt voor <strong>de</strong> quasi-blijven<strong>de</strong> windbelasting<br />

− γM : <strong>de</strong> partiële coëfficiënt voor <strong>de</strong> materialen (zie hoofdstuk 5)<br />

− Xd : <strong>de</strong> rekenwaar<strong>de</strong> voor <strong>de</strong> materialen (zie hoofdstuk 5).<br />

De rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong> borstweringsfunctie en <strong>het</strong><br />

eigengewicht Fd(C) evenals <strong>de</strong> criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n zijn <strong>op</strong>genomen in <strong>de</strong> tabellen 33<br />

tot 35.<br />

4.6.3.5. Rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie veroorzaakt door <strong>de</strong><br />

borstweringsfunctie, <strong>het</strong> eigengewicht en sneeuw Fd(Ab, gk, sk)<br />

Deze belastingscombinatie hoeft doorgaans niet in aanmerking genomen te wor<strong>de</strong>n.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

99


Parameters<br />

Partiële coëfficiënten en begelei<strong>de</strong>n<strong>de</strong><br />

coëfficiënten<br />

Hoofdconstructie<br />

(veranda’s,<br />

categorie 3)<br />

Verankering <strong>van</strong> <strong>de</strong> secundaire<br />

constructie<br />

ψ0 ψ1 ψ2<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) (<br />

Tabel 33 Bepaling <strong>van</strong> <strong>de</strong> belasting Fd(g,Ab,w) <strong>op</strong> hellen<strong>de</strong> schrijnwerkelementen (1).<br />

2 Zie Euroco<strong>de</strong>s en<br />

)<br />

Uiterste grenstoestan<strong>de</strong>n (UGT)<br />

normen Ed(g,w) ≤ Xk/γM ( 1 )<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> belastingscombinatie.<br />

( 2 ) De verankeringen wor<strong>de</strong>n gewoonlijk enkel in <strong>de</strong> UGT berekend. Indien nodig, moet <strong>het</strong> gebruiksgeschiktheidscriterium<br />

<strong>van</strong> <strong>de</strong> GGT bepaald wor<strong>de</strong>n, rekening hou<strong>de</strong>nd met <strong>de</strong> <strong>ontwerp</strong>situatie.<br />

( 3 ) Fdx,y (Cx) : <strong>de</strong> eerste numerieke in<strong>de</strong>x stelt <strong>het</strong> belastingsgeval voor; er wor<strong>de</strong>n vier belastingsgevallen on<strong>de</strong>rschei<strong>de</strong>n.<br />

Wanneer <strong>de</strong> twee<strong>de</strong> numerieke in<strong>de</strong>x gelijk is aan 1, is <strong>de</strong> vergelijking <strong>van</strong> toepassing indien <strong>de</strong> belasting door <strong>het</strong><br />

eigengewicht een ongunstig effect heeft. Wanneer <strong>de</strong>ze in<strong>de</strong>x gelijk is aan 2, is <strong>de</strong> vergelijking <strong>van</strong> toepassing als <strong>de</strong><br />

belasting door <strong>het</strong> eigengewicht een gunstig effect heeft.<br />

( 4 ) Indien een veran<strong>de</strong>rlijke belasting een gunstig effect heeft (vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> resultante Fd), moet <strong>de</strong><br />

belastingscombinatie waarin <strong>de</strong>ze veran<strong>de</strong>rlijke belasting gelijk is aan nul eveneens in aanmerking genomen wor<strong>de</strong>n (zie<br />

§ 4.6.1)<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

γG<br />

γQ<br />

1,35 1,5<br />

0,3 0,7 0,0<br />

γG,sup γG,inf γQ<br />

1,20 1,0 1,35<br />

Waar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) ( 4 ) :<br />

Fd(C1) = gk +ψ1.qk,h +ψ2 w<br />

Fd(C2) = gk +ψ1.Qkh,1 +ψ2 w<br />

Fd(C3) = gk +ψ1.Qkh,2 + ψ2 w<br />

Fd(C4) = gk + ψ1.Qkv,3 +ψ2 w<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) ( 3 ) ( 4 ) :<br />

Fd1,1 (C1) = γG,sup gk + γQ qk,h + ψ0 γQ w<br />

Fd1,2 (C1) = γG,inf gk + γQ qk,h + ψ0 γQ w<br />

Fd2,1 (C2) = γG,sup gk + γQ Qkh,1+ ψ0 γQ w<br />

Fd2,2 (C2) = γG,inf gk + γQ Qkh,1+ ψ0 γQ w<br />

Fd3,1 (C3) = γG,sup gk + γQ Qkh,2 + ψ0 γQ w<br />

Fd3,2 (C3) = γG,inf gk + γQ Qkh,2+ ψ0 γQ w<br />

Fd4,1 (C4) = γG,sup gk +γQ Qkv,3 + ψ0. γQ w<br />

Fd4,2 (C4) = γG,inf gk + γQ Qkv,3 + ψ0. γQ w<br />

Zie Euroco<strong>de</strong>s en<br />

normen<br />

Zie Euroco<strong>de</strong>s en<br />

normen<br />

Fd1 (C1) = gk + 0,7 . qk,h<br />

Fd2 (C2) = gk + 0,7.Qkh,1<br />

–<br />

Fd4 (C4) = gk + 0,7.Qkv,3<br />

Fd1,1 (C1) = 1,2 gk + 1,35 qk,h+ 0,4 w<br />

Fd1,2 (C1) = 1,0 gk + 1,35 qk,h + 0,4 w<br />

Fd2,1 (C2) = 1,2 gk + 1,35 Qkh,1 + 0,4 w<br />

Fd2,2 (C2) = 1,0 gk + 1,35 Qkh,1 + 0,4 w<br />

–<br />

–<br />

Fd4,1 (C4) = 1,2 gk + 1,35 Qkv,3 + 0,4 w<br />

Fd4,2 (C4) = 1,0 gk + 1,35 Qkv,3 + 0,4 w<br />

100


Parameters Secundaire constructie<br />

Partiële coëfficiënten en begelei<strong>de</strong>n<strong>de</strong><br />

coëfficiënten<br />

γG,sup<br />

1,15<br />

γG,inf<br />

1,0<br />

γQ<br />

1,25<br />

ψ0<br />

0,3<br />

ψ1<br />

0,7<br />

ψ2<br />

0,0<br />

Waar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) ( 6 )<br />

Fd(C1) = gk +ψ1.qk,h +ψ2 w<br />

Fd1 (C1) = gk + 0,7.qk,h<br />

Fd(C2) = gk +ψ1.Qkh,1 +ψ2 w<br />

Fd(C3) = gk +ψ1.Qkh,2 + ψ2 w<br />

Fd2 (C2) = gk + 0,7.Qkh,1<br />

Fd3 (C3) = gk + 0,7.Qkh,2 ( 5 )<br />

Fd4 (C4) = gk + 0,7.Qkv,3<br />

Fd(C4) = gk + ψ1.Qkv,3 +ψ2 w<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) ( 2 ) ( 6 )<br />

Fd1,1 (C1) = γG,sup gk + γQ qk,h + ψ0 γQ w<br />

Fd1,2 (C1 ) = γG,inf gk + γQ qk,h + ψ0 γQ w<br />

Fd2,1 (C2) = γG,sup gk + γQ Qkh,1+ ψ0 γQ w<br />

Fd2,2 (C2) = γG,inf gk + γQ Qkh,1+ ψ0 γQ w<br />

Fd3,1 (C3 ) = γG,sup gk + γQ Qkh,2+ ψ0 γQ w<br />

Fd3,2 (C3 ) = γG,inf gk + γQ Qkh,2+ ψ0 γQ w<br />

Fd4,1 (C4) = γG,sup gk +γQ Qkv,3 + ψ0. γQ w<br />

Fd4,2 (C4) = γG,inf gk + γQ Qkv,3 + ψ0. γQ w<br />

Fd1,1 (C1) = 1,15 gk + 1,25 qk,h+ 0,375 w<br />

Fd1,2 (C1) = 1,0 gk + 1,25 qk,h + 0,375 w<br />

Fd2,1 (C2) = 1,15 gk + 1,25 Qkh,1+ 0,375 w<br />

Fd2,2 (C2) = 1,0 gk + 1,25 Qkh,1 + 0,375 w<br />

Fd3,1 (C3) = 1,15 gk + 1,25 Qkh,2+ 0,375 w ( 5 )<br />

Fd3,2 (C3) = 1,0 gk + 1,25 Qkh,2 + 0,375 w ( 5 )<br />

Fd4,1 (C4) = 1,15 gk + 1,25 Qkv,3 + 0,375 w<br />

Fd4,2 (C4) = 1,0 gk + 1,25 Qkv,3+ 0,375 w<br />

Dakvensters en veranda’s Lichte structuren en veranda’s<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

(categorie 1)<br />

(categorie 2)<br />

Vervorming <strong>van</strong> <strong>de</strong> stijlen en <strong>de</strong> dwarsregels<br />

(zie afbeelding 58 en afbeelding 59) (<br />

Tabel 34 Bepaling <strong>van</strong> <strong>de</strong> belasting Fd(g,Ab,w) <strong>op</strong> hellen<strong>de</strong> schrijnwerkelementen (2).<br />

7 Gebruiksgrenstoestan<strong>de</strong>n (GGT)<br />

)<br />

y┴ ≤ L/200 ( 4 ) ( 5 )<br />

y// ≤ L/500 of ≤ 3 mm ( 3 y┴ ≤ L/250 indien L ≤ 3,5 m<br />

y┴ ≤ 4 + L/330 indien 3,5 m < L < 7,5 m<br />

) y┴ ≤ L/275 indien L ≥ 7,5 m ( 4 ) ( 5 )<br />

y// = 1/500 of ≤ 3 mm ( 3 )<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) Geen controle Ed(g,w) ≤ Xd /γM ( 1 )<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> belastingscombinatie.<br />

( 2 ) Fdx,y (Cx) : <strong>de</strong> eerste numerieke in<strong>de</strong>x geeft <strong>het</strong> belastingsgeval weer; er wor<strong>de</strong>n dus vier belastingsgevallen on<strong>de</strong>rschei<strong>de</strong>n.<br />

Wanneer <strong>de</strong> twee<strong>de</strong> numerieke in<strong>de</strong>x gelijk is aan 1, is <strong>de</strong> vergelijking <strong>van</strong> toepassing indien <strong>de</strong> belasting veroorzaakt door <strong>het</strong><br />

eigengewicht een ongunstig effect heeft. Wanneer <strong>de</strong>ze in<strong>de</strong>x gelijk is aan 2, is <strong>de</strong> vergelijking <strong>van</strong> toepassing als <strong>de</strong> belasting<br />

veroorzaakt door <strong>het</strong> eigengewicht een gunstig effect heeft.<br />

( 3 ) Dit vervormingscriterium geldt voor <strong>de</strong> eventuele dwarsregel on<strong>de</strong>r <strong>de</strong> blijven<strong>de</strong> component <strong>van</strong> Fd = gk wanneer <strong>het</strong> vulpaneel<br />

niet in staat is <strong>de</strong> belasting E// <strong>op</strong> te nemen. Het criterium kan aangepast wor<strong>de</strong>n naargelang <strong>van</strong> <strong>de</strong> maximaal toegelaten<br />

vervorming, zon<strong>de</strong>r <strong>het</strong> vulpaneel te raken. Wanneer <strong>de</strong> <strong>op</strong>spanning <strong>van</strong> <strong>de</strong> dwarsregel <strong>op</strong> <strong>het</strong> vulelement toegelaten is, moet <strong>de</strong><br />

stabiliteit <strong>van</strong> <strong>het</strong> vulelement gecontroleerd wor<strong>de</strong>n (zie tabel 35). Indien nodig, dient men een voldoen<strong>de</strong> ruimte te laten voor <strong>de</strong><br />

drainering en <strong>de</strong> ventilatie.<br />

( 4 ) Dit vervormingscriterium geldt voor <strong>de</strong> stijlen en <strong>de</strong> eventuele dwarsregel <strong>op</strong> <strong>de</strong> veiligheidshoogte, on<strong>de</strong>r <strong>de</strong> belastingen E┴. Dit<br />

criterium kan eventueel ook toegepast wor<strong>de</strong>n <strong>op</strong> <strong>de</strong> belasting E┴, wanneer Qkh,2 aangrijpt <strong>op</strong> <strong>de</strong> dwarsregel (zie nota ( 5 ) hierna).<br />

( 5 ) Van toepassing <strong>op</strong> <strong>de</strong> situatie uit § 4.4.2.5.4.2 en uit afbeelding 45, wanneer <strong>de</strong> dwarsregel zich <strong>op</strong> een lagere hoogte bevindt dan<br />

<strong>de</strong> beschermingshoogte H.<br />

( 6 ) Indien een veran<strong>de</strong>rlijke belasting een gunstig effect heeft (vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> resultante Fd), moet <strong>de</strong> belastingscombinatie<br />

waarin <strong>de</strong>ze veran<strong>de</strong>rlijke belasting gelijk is aan nul eveneens in aanmerking genomen wor<strong>de</strong>n.<br />

( 7 ) Het voorgestel<strong>de</strong> vervormingscriterium kan aangepast wor<strong>de</strong>n naargelang <strong>van</strong> <strong>de</strong> <strong>ontwerp</strong>voorwaar<strong>de</strong>n (materialen, helling,<br />

drainage, …).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

101


Parameters<br />

Partiële coëfficiënt voor <strong>de</strong> belastingen<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) ( 5 )<br />

Fd(C1) = gk +ψ1.qk,h +ψ2 w<br />

Fd(C2) = gk +ψ1.Qkh,1 +ψ2 w<br />

Fd(C3) = gk +ψ1 Qkh,2 + ψ2 w<br />

Fd(C4) = gk + ψ1.Qkv,3 +ψ2 w<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) ( 5 )<br />

Fd1 (C1) = γG, gk + γQ qk,h + ψ0 γQ w<br />

Fd2 (C2) = γG gk + γQ Qkh,1+ ψ0 γQ w<br />

Fd3 (C3) = γG gk + γQ Qkh,2+ ψ0 γQ w<br />

Fd4 (C4) = γG gk +γQ Qkv,3 + ψ0. γQ w<br />

Verlijming <strong>van</strong> <strong>het</strong> SGG ( 2 ) of verankering <strong>van</strong> <strong>de</strong><br />

vulelementen<br />

Criteria voor <strong>de</strong> grenstoestan<strong>de</strong>n<br />

Gebruiksgrenstoestan<strong>de</strong>n (GGT) - Vervorming of belasting (<br />

Tabel 35 Bepaling <strong>van</strong> <strong>de</strong> belasting Fd(g,Ab,w) <strong>op</strong> hellen<strong>de</strong> schrijnwerkelementen (3).<br />

3 )<br />

Uiterste grenstoestan<strong>de</strong>n (UGT) Ed(g, Ab ) ≤ Xd /γM ( 1 ) Ed(g, Ab ) ≤ Xd /γM ( 1 )<br />

( 1 ) Ed vertegenwoordigt <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> meest ongunstige belastingen, veroorzaakt door <strong>de</strong> belastingscombinatie.<br />

( 2 ) Voor <strong>de</strong> dimensionering en <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG (zie bijlage B, ETAG 002) :<br />

− hc on<strong>de</strong>r trek : wanneer <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG on<strong>de</strong>rworpen is aan een blijven<strong>de</strong> trekkracht, dient men veiligheidsvoorzieningen aan te wen<strong>de</strong>n, die zodanig berekend<br />

zijn, dat ze in staat zijn <strong>de</strong> resultante E┴ <strong>van</strong> <strong>de</strong> belastingscombinatie Fd <strong>op</strong> te nemen<br />

− hc on<strong>de</strong>r druk : <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG is in staat een beperkte blijven<strong>de</strong> druk <strong>op</strong> te nemen, die <strong>op</strong>gegeven wordt door <strong>de</strong> producent. Indien <strong>de</strong> druk groter is, moet een<br />

gepaste <strong>op</strong>spanning wor<strong>de</strong>n voorzien om <strong>de</strong> drukresultante E┴ <strong>van</strong> <strong>de</strong> belastingscombinatie Fd over te brengen <strong>op</strong> <strong>het</strong> verlijmingska<strong>de</strong>r.<br />

( 3 ) Vervorming en/of belasting naargelang <strong>van</strong> <strong>de</strong> productspecificaties.<br />

( 4 ) Het is doorgaans onmogelijk om <strong>de</strong> belasting Qkv,3 rechtstreeks toe te passen <strong>op</strong> <strong>het</strong> vulelement (zie § 4.4). Wanneer <strong>de</strong> <strong>op</strong>spanning <strong>van</strong> <strong>de</strong> dwarsregel <strong>op</strong> <strong>het</strong> vulelement<br />

toegelaten is, moet <strong>de</strong> stabiliteit <strong>van</strong> <strong>het</strong> vulelement gecontroleerd wor<strong>de</strong>n in <strong>het</strong> geval <strong>van</strong> een <strong>op</strong>engaan<strong>de</strong> vleugel, on<strong>de</strong>r <strong>de</strong> resultante E// <strong>van</strong> <strong>de</strong> belastingscombinatie Fd4.<br />

( 5 ) Indien een veran<strong>de</strong>rlijke belasting een gunstig effect heeft (vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> resultante Fd), moet <strong>de</strong> belastingscombinatie waarin <strong>de</strong>ze veran<strong>de</strong>rlijke belasting gelijk is aan<br />

nul eveneens in aanmerking genomen wor<strong>de</strong>n (zie § 4.6.1).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

102<br />

Vulelementen<br />

γG γQ ψ0 ψ1 ψ2 γG γQ ψ0 ψ1 ψ2<br />

1,1 1,1 0,3 0,7 0,0 1,1 1,1 0,3 0,7 0,0<br />

Waar<strong>de</strong>n voor <strong>de</strong> belastingscombinatie<br />

Fd(C1) = gk +0,7.qk,h<br />

Fd(C2) = gk +0,7.Qkh,1<br />

Fd(C3) = gk +0,7.Qkh,2<br />

Fd(C4) = gk + 0,7.Qkv,3 ( 4 )<br />

Fd1,(C1) = 1,1 gk + 1,1 qk,h<br />

Fd2 (C2) = 1,1 gk + 1,1 Qkh,1<br />

Fd3 (C3) = 1,1 gk + 1,1 Qkh,2<br />

Fd4 (C4) = 1,1 gk + 1,1 Qkv,3<br />

Fd(C1) = 1,0.gk +0,7.qk,h<br />

Fd(C2) = 1,0.gk +0,7.Qkh,1<br />

Fd(C3) = 1,0.gk +0,7.Qkh,2<br />

Fd(C4) = 1,0.gk + 0,7.Qkv,3 ( 4 )<br />

Fd1,(C1) = 1,1 gk + 1,1 qk,h<br />

Fd2 (C2) = 1,1.gk + 1,1.Qkh,1<br />

Fd3 (C3) = 1,1 gk + 1,1.Qkh,2<br />

Fd4 (C4) = 1,1 gk + 1,1.Qkv,3


5. ONTWERPWAARDEN VAN DE MATERIALEN (eenhe<strong>de</strong>n N<br />

en mm)<br />

Karakteristieke weerstand <strong>van</strong> <strong>de</strong> materialen ( 1 )<br />

Aluminium (NBN EN 755)<br />

Legering EN AW 6060 T5 - e < 5 mm - Rp0,2 =<br />

Legering EN AW 6060 T66 - e < 3 mm - Rp0,2 =<br />

Legering EN AW 6063 T5 - e < 3 mm - Rp0,2 =<br />

Legering EN AW 6063 T66 - e < 10 mm - Rp0,2 =<br />

<strong>Toepassing</strong>sgebied <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s<br />

Karakt.<br />

waar<strong>de</strong><br />

[N/mm²]<br />

Rekenwaar<strong>de</strong><br />

[N/mm²]<br />

Partiële en<br />

wijzigingscoëfficiënten<br />

Xk Xd γM ( 3 )<br />

120<br />

160<br />

130<br />

200<br />

120<br />

160<br />

130<br />

200<br />

Staal (waar<strong>de</strong>n voor profielen) Xk Xd γM ( 3 )<br />

NBN EN 10327<br />

Versteviging <strong>van</strong> PVC-profielen<br />

Gegal<strong>van</strong>iseerd staal DX 51D<br />

NBN EN 10025-2<br />

S235 - e ≤ 16 mm - ReH =<br />

S355 - e ≤ 16 mm - ReH =<br />

NBN EN 10088-2 (roestvrij staal)<br />

X5CrNi 8-10 - 1.4301 - e < 8 mm Rp0,2 =<br />

X5CrNi 8-10 - 1.4301 - e < 75 mm Rp0,2 =<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

1,0<br />

1,0<br />

1,0<br />

1,0<br />

– – 1,0<br />

235<br />

355<br />

235<br />

355<br />

230 230<br />

210 210<br />

Hout – Blijven<strong>de</strong> belastingen ( 2 )<br />

Massief hout klasse C24 (NBN EN 338) Xk Xd γM kmod<br />

Buiging 24 11,0 1,3 0,6<br />

Axiale druk 21 9,7 1,3 0,6<br />

Afschuiving 2,5 1,15 1,3 0,6<br />

Axiale trek 15 6,9 1,3 0,6<br />

Hout – Kortetermijnbelastingen ( 2 )<br />

Massief hout klasse C24 (NBN EN 338) Xk Xd γM kmod<br />

Buiging 24 16,6 1,3 0,9<br />

Axiale druk 21 14,5 1,3 0,9<br />

Afschuiving 2,5 1,7 1,3 0,9<br />

Axiale trek 15 10,3 1,3 0,9<br />

Hout – Combinatie <strong>van</strong> blijven<strong>de</strong> en kortetermijnbelastingen ( 2 )<br />

Massief hout klasse C24 (NBN EN 338) Xk Xd γM kmod<br />

Buiging 24 16,6 1,3 0,9<br />

Axiale druk 21 14,5 1,3 0,9<br />

Afschuiving 2,5 1,7 1,3 0,9<br />

Axiale trek 15 10,3 1,3 0,9<br />

1,0<br />

1,0<br />

Vervormingsmodulus<br />

en<br />

vervormingscoëfficiënt<br />

[N/mm²]<br />

E0 = 70 000<br />

E0 = 210 000<br />

E0 = 11 000<br />

k<strong>de</strong>f = 0,8<br />

Efin = E0/(1+k<strong>de</strong>f)<br />

Efin = 6 111 MPa<br />

E0 = 11 000<br />

k<strong>de</strong>f = 0,8<br />

ψ2 = 0<br />

Efin=E0/(1+ψ2.k<strong>de</strong>f)<br />

Efin = 11 000<br />

E0 = 11 000<br />

k<strong>de</strong>f = 0,8<br />

ψ2 = 0<br />

Ecal = X MPa<br />

Zie ( 2 ) (§ 3) en<br />

bijlage 5<br />

( 1 ) In <strong>de</strong>ze tabel zijn enkel <strong>de</strong> eigenschappen <strong>van</strong> <strong>de</strong> meest gebruikte materialen voor schrijnwerk <strong>op</strong>genomen. Wanneer er an<strong>de</strong>re<br />

materialen wor<strong>de</strong>n gebruikt, moet <strong>de</strong> <strong>op</strong>steller <strong>van</strong> <strong>het</strong> bestek een beroep doen <strong>op</strong> <strong>de</strong> normen of <strong>de</strong> technische fiches met<br />

betrekking tot <strong>de</strong> materialen in kwestie.<br />

( 2 ) Wat <strong>de</strong> houteigenschappen betreft, geeft <strong>de</strong> norm NBN EN 338 een overzicht <strong>van</strong> <strong>de</strong> verschillen<strong>de</strong> houtklassen en hun<br />

karakteristieke waar<strong>de</strong>n :<br />

1. blijven<strong>de</strong> belastingen :<br />

− modulus voor <strong>de</strong> belasting veroorzaakt door <strong>het</strong> eigengewicht (NBN EN 1995-1-1, tabellen 2.1 en 2.2) : blijven<strong>de</strong><br />

belasting en gebruikscategorie 2 volgens EN 1995-1-1 (§ 2.3.1.3, k<strong>de</strong>f = 0,8, tabel 3.2) : Efin = E0/(1+k<strong>de</strong>f)<br />

103


− <strong>de</strong> rekenwaar<strong>de</strong> Xd <strong>van</strong> een houteigenschap wordt ge<strong>de</strong>finieerd door : Xd = kmod Xk/γM, waarbij kmod <strong>de</strong> mogelijkheid biedt<br />

om <strong>het</strong> effect <strong>van</strong> <strong>de</strong> belastingsduur en <strong>de</strong> vochtigheid <strong>op</strong> <strong>de</strong> weerstand in aanmerking te nemen (EN 1995-1-1, tabel 3.1,<br />

eigengewicht kmod = 0,6)<br />

2. kortetermijnbelastingen :<br />

− modulus E0 voor <strong>de</strong> windbelasting (NBN EN 1995-1-1, tabellen 2.1 en 2.2) : kortetermijnbelasting en gebruikscategorie<br />

2 volgens EN 1995-1-1 (§ 3.2, tabel 3.2, k<strong>de</strong>f = 0,8, tabel 4.1) : E0 = ogenblikkelijke modulus die overeenstemt met <strong>de</strong><br />

kortetermijnbelastingen<br />

− mechanische karakteristieken voor <strong>de</strong> windbelasting : <strong>de</strong> rekenwaar<strong>de</strong> Xd voor een houteigenschap wordt ge<strong>de</strong>finieerd<br />

door : Xd = kmod Xk/γM, waarbij kmod <strong>de</strong> mogelijkheid biedt om <strong>het</strong> effect <strong>van</strong> <strong>de</strong> belastingsduur en <strong>de</strong> vochtigheid <strong>op</strong> <strong>de</strong><br />

weerstand in aanmerking te nemen (NBN EN 1995-1-1, tabel 3.1, wind kmod = 0,9)<br />

3. combinatie <strong>van</strong> <strong>de</strong> blijven<strong>de</strong> en <strong>de</strong> kortetermijnbelastingen :<br />

− berekening <strong>van</strong> <strong>de</strong> vervorming :<br />

gebruikscategorie 2 (NBN EN 1995-1-1, § 2.3.1.3)<br />

belastingsduur (NBN EN 1995 -1-1, tabellen 2.1 en 2.2) :<br />

eigengewicht : blijven<strong>de</strong> belasting<br />

wind, sneeuw en belastingen door <strong>de</strong> borstweringsfunctie : kortetermijnbelastingen<br />

Men dient <strong>de</strong> totale doorbuiging µfin te berekenen door <strong>de</strong> som te maken <strong>van</strong> <strong>de</strong> doorbuiging <strong>van</strong> elke belasting volgens <strong>het</strong><br />

principe <strong>van</strong> <strong>de</strong> NBN EN 1995-1-1 (§ 2.2.3) : µfin = µfin,G + µw +µsk+ µ Ab waarbij<br />

voor <strong>de</strong> bijven<strong>de</strong> belastingen µfin,G = µinst,G (1+k<strong>de</strong>f)<br />

voor <strong>de</strong> dominante veran<strong>de</strong>rlijke belasting µQ,1 = µinst,Q,1 (1+ ψ2 k<strong>de</strong>f)<br />

voor veran<strong>de</strong>rlijke begelei<strong>de</strong>n<strong>de</strong> belastingen µQ = µfin,Q,i (ψ0,i+ ψ2,i k<strong>de</strong>f), waarin<br />

µinst = <strong>de</strong> doorbuiging met <strong>de</strong> modulus E0<br />

k<strong>de</strong>f = 0,8 volgens EN 1995-1-1 (§ 2.3.1.2, tabel 3.2)<br />

ψ2 = 0 volgens NBN EN 1990–ANB (§ A1.2.2, tabel A1.1)<br />

ψ0 <strong>op</strong>gegeven wordt in § 4.6. In ons geval wordt <strong>de</strong>ze altijd gebruikt voor <strong>de</strong> berekening in <strong>de</strong> UGT en dus niet<br />

voor een berekening <strong>van</strong> <strong>de</strong> doorbuiging. Rekening hou<strong>de</strong>nd met <strong>de</strong>ze twee vereenvoudigen<strong>de</strong> elementen, stelt<br />

bijlage 5 een bepalingsmetho<strong>de</strong> voor <strong>de</strong> gewogen gemid<strong>de</strong>l<strong>de</strong> modulus Em voor, die toegepast kan wor<strong>de</strong>n <strong>op</strong> <strong>de</strong><br />

blijven<strong>de</strong> en <strong>de</strong> kortetermijnbelastingen, tenein<strong>de</strong> <strong>de</strong> doorbuiging in één enkele berekening te kunnen bepalen<br />

− <strong>de</strong> rekenwaar<strong>de</strong> Xd <strong>van</strong> een houteigenschap wordt ge<strong>de</strong>finieerd door : Xd = kmod Xk/γM, waarbij kmod <strong>de</strong> mogelijkheid biedt<br />

om <strong>het</strong> effect <strong>van</strong> <strong>de</strong> belastingsduur en <strong>de</strong> vochtigheid <strong>op</strong> <strong>de</strong> weerstand in aanmerking te nemen. In <strong>het</strong> geval <strong>van</strong> een<br />

combinatie <strong>van</strong> belastingen met een verschillen<strong>de</strong> duur, dient men <strong>de</strong> kmod <strong>van</strong> <strong>de</strong> belasting met <strong>de</strong> kortste duur te<br />

gebruiken (EN 1995-1-1, § 3.1.3, tabel 3.1, combinatie <strong>van</strong> <strong>de</strong> wind, sneeuw en <strong>het</strong> eigengewicht) : kmod = 0,9.<br />

( 3 ) De waar<strong>de</strong> <strong>van</strong> <strong>de</strong> coëfficiënt γM voor staal en aluminium is 1. Dit betekent echter niet dat <strong>de</strong>ze materialen perfect betrouwbaar<br />

zou<strong>de</strong>n zijn, noch dat er geen onzekerhe<strong>de</strong>n bestaan omtrent hun eigenschappen of <strong>het</strong> mo<strong>de</strong>l (dimensionale schommelingen, ...).<br />

De re<strong>de</strong>n hiervoor is historisch. De Euroco<strong>de</strong>s voor <strong>de</strong> belastingen wer<strong>de</strong>n immers oorspronkelijk ontwikkeld voor beton. Voor<br />

<strong>de</strong> an<strong>de</strong>re materialen wer<strong>de</strong>n <strong>de</strong> partiële coëfficiënten γM zodanig aangepast dat men <strong>de</strong>zelf<strong>de</strong> γQ-waar<strong>de</strong>n als voor beton<br />

verkreeg. Dit heeft tot gevolg dat <strong>de</strong> γQ-coëfficiënt voor an<strong>de</strong>re materialen dan beton een bepaal<strong>de</strong> mate <strong>van</strong> onzekerheid inhoudt<br />

(zie ook NBN EN 1990, bijlage C, § C9, γSd). De weerstand en <strong>de</strong> onzekerhe<strong>de</strong>n voor <strong>de</strong> berekening <strong>van</strong> <strong>de</strong>ze materialen hebben<br />

statische variatiecoëfficiënten die lager zijn dan <strong>de</strong>ze voor beton.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

104


Buiten <strong>het</strong> toepassingsgebied <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s ( 1 )<br />

Glas<br />

Buigsterkte Xk γM Xg,d kmod<br />

uitgegloeid glas (NBN EN 572-1) 45 1,8<br />

halfgehard glas (NBN EN 1863-1) 70 1,8<br />

gehard glas (NBN EN 12150-1) 120 1,8<br />

Verlijmingskit voor SGG ( 2 )<br />

Zie bijlage 7<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

Ru,5<br />

τ<strong>de</strong>s/<br />

Siliconen ETA ETA ETA ETA<br />

Γ∞<br />

γM<br />

γc<br />

E0 = 70 000<br />

E0 (zie ETA)<br />

( 1 ) In <strong>de</strong>ze tabel zijn enkel <strong>de</strong> eigenschappen <strong>van</strong> <strong>de</strong> meest gebruikte materialen voor schrijnwerk <strong>op</strong>genomen.<br />

Wanneer er an<strong>de</strong>re materialen wor<strong>de</strong>n gebruikt, moet <strong>de</strong> <strong>op</strong>steller <strong>van</strong> <strong>het</strong> bestek een beroep doen <strong>op</strong> <strong>de</strong><br />

normen of <strong>de</strong> technische fiches met betrekking tot <strong>de</strong> materialen in kwestie.<br />

( 2 ) De ETAG 002 over SGG schrijft een veiligheidscoëfficiënt γtot <strong>van</strong> 6 voor, waarmee <strong>de</strong> berekening <strong>van</strong> τ<strong>de</strong>s<br />

mogelijk wordt, uitgaan<strong>de</strong> <strong>van</strong> Ru,5 (Ru,5 uit ETAG 002 = Xk uit <strong>de</strong> Euroco<strong>de</strong>s). Wanneer <strong>het</strong> eigengewicht <strong>van</strong><br />

<strong>de</strong> vulelementen wordt <strong>op</strong>genomen door <strong>de</strong> verlijming <strong>van</strong> <strong>het</strong> SGG, is <strong>het</strong> bovendien noodzakelijk rekening<br />

te hou<strong>de</strong>n met <strong>de</strong> kruipcoëfficiënt γc :<br />

Γ∞ = R u,5 /( γM γc).<br />

In <strong>de</strong> praktijk wordt <strong>de</strong> coëfficiënt γtot = 6 vaak geassimileerd met γM, wat niet zel<strong>de</strong>n aanleiding geeft tot een<br />

overdimensionering. De bepalingsmetho<strong>de</strong> <strong>van</strong> γtot uit <strong>de</strong> Eur<strong>op</strong>ese specificaties (ETAG 002, EN 13022, EN<br />

15434) is niet bevredigend, aangezien γtot bepaald wordt ten aanzien <strong>van</strong> <strong>de</strong> breuk <strong>van</strong> <strong>de</strong> verlijmingskit. Door<br />

<strong>de</strong>ze coëfficiënt in aanmerking te nemen zal een stijve kit met een hoge E0-modulus niet <strong>de</strong>zelf<strong>de</strong><br />

betrouwbaarheid vertonen dan een min<strong>de</strong>r stijve kit die een hoge verlenging (rek) bij breuk vertoont, vermits<br />

<strong>de</strong> krommen voor <strong>de</strong> spanning/verlenging (rek) totaal verschillend zijn. Het zou veel meer in<br />

overeenstemming zijn met <strong>de</strong> filosofie <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s om <strong>het</strong> werkingsgebied <strong>van</strong> <strong>de</strong> hechtingskitten (een<br />

werkingsgebied omschreven door een maximale verlenging <strong>van</strong> 12,5 % wordt doorgaans aanvaard) en een<br />

partiële coëfficiënt γM (aan <strong>de</strong> hand <strong>van</strong> <strong>de</strong> veran<strong>de</strong>rlijkheid <strong>van</strong> <strong>het</strong> materiaal en <strong>de</strong> rekenmetho<strong>de</strong>n) te<br />

bepalen. De coëfficiënt γM zou dan toegepast kunnen wor<strong>de</strong>n <strong>op</strong> <strong>de</strong> karakteristieke spanning <strong>op</strong> <strong>de</strong> grens <strong>van</strong><br />

<strong>het</strong> werkingsgebied (12,5 % verlenging). De proeven, uitgevoerd aan <strong>de</strong> hand <strong>van</strong> <strong>de</strong> huidige gegevens tonen<br />

aan dat <strong>de</strong> coëfficiënt γM in dat geval <strong>de</strong> waar<strong>de</strong> 2 zou bena<strong>de</strong>ren, wat geruststellend is voor <strong>de</strong> <strong>ontwerp</strong>ers<br />

die gewend zijn te werken met <strong>de</strong> semi-probabilistische bena<strong>de</strong>ring. Een materiaal dat een partiële coëfficiënt<br />

<strong>van</strong> 6 nodig heeft, wordt immers gekenmerkt door een grote veran<strong>de</strong>rlijkheid, wat niet correct is voor <strong>het</strong> hier<br />

beschouw<strong>de</strong> geval.<br />

105


6. REFERENTIEDOCUMENTEN<br />

1. NBN EN 1990:2002 Euroco<strong>de</strong>. Grondslag voor constructief <strong>ontwerp</strong>.<br />

2. NBN EN 1990 ANB:2005 Euroco<strong>de</strong> 0. Grondslag voor <strong>het</strong> constructief <strong>ontwerp</strong>.<br />

Bijlage A1 : toepassing <strong>op</strong> gebouwen. Nationale Belgische Bijlage.<br />

3. NBN EN 1990/A1:2006 Euroco<strong>de</strong>. Grondslagen <strong>van</strong> <strong>het</strong> constructief <strong>ontwerp</strong>.<br />

4. NBN EN 1991-1-1:2002 Euroco<strong>de</strong> 1. Belastingen <strong>op</strong> constructies. Deel 1-1 : algemene<br />

belastingen. Dichthe<strong>de</strong>n, eigengewicht en <strong>op</strong>geleg<strong>de</strong> belastingen voor gebouwen.<br />

5. NBN EN 1991-1-1 ANB:2005 Euroco<strong>de</strong> 1. Belastingen <strong>op</strong> constructies. Deel 1.1 :<br />

algemene belastingen. Volumieke gewichten, eigengewicht en <strong>op</strong>geleg<strong>de</strong> belastingen<br />

voor gebouwen. Nationale Belgische Bijlage.<br />

6. NBN EN 1991-1-3:2003 Euroco<strong>de</strong> 1. Belastingen <strong>op</strong> constructies. Deel 1-3 : algemene<br />

belastingen. Sneeuwbelasting.<br />

7. NBN EN 1991-1-3 ANB:2005 Euroco<strong>de</strong> 1. Belastingen <strong>op</strong> constructies. Deel 1-3 :<br />

algemene belastingen. Sneeuwbelasting. Nationale Belgische Bijlage.<br />

8. NBN EN 1991-1-4:2005 Euroco<strong>de</strong> 1. Belastingen <strong>op</strong> constructies. Deel 1-4 : algemene<br />

belastingen. Windbelasting.<br />

9. NBN EN 1991-1-5:2004 Euroco<strong>de</strong> 1. Belastingen <strong>op</strong> constructies. Deel 1-5 : algemene<br />

belastingen. Thermische belasting.<br />

10. NBN EN 1993-1-1:2005 Euroco<strong>de</strong> 3. Ontwerp en berekening <strong>van</strong> staalconstructies.<br />

Deel 1-1 : algemene regels en regels voor gebouwen.<br />

11. NBN EN 1995-1-1:2005 Ontwerp en berekening <strong>van</strong> houtconstructies. Deel 1-1 :<br />

algemeen. Gemeenschappelijke regels en regels voor gebouwen.<br />

12. NBN ENV 1999-1-1:1998 Euroco<strong>de</strong> 9. Ontwerp en berekening <strong>van</strong><br />

aluminiumconstructies. Deel 1-1 : algemene regels.<br />

13. NBN B 03-003:2003 Vervormingen <strong>van</strong> draagsystemen. Vervormingsgrenswaar<strong>de</strong>n.<br />

Gebouwen.<br />

14. NBN B 25-002-1:2008 Buitenschrijnwerk. Deel 1 : algemene voorschriften.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

106


BIJLAGE 1 REFERENTIESNELHEID VAN DE WIND Vb,0<br />

v b,0 = 26 m/sec m/s<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

v vb,0 b,0 = 25 m/sec m/s<br />

v b,0 = 24 m/sec m/s<br />

Referentiesnelheid <strong>van</strong> <strong>de</strong> wind v b,0 [m/sec] [m/s]<br />

v b,0 = 23 m/sec m/s<br />

107


Snelheid vb,0 [m/s] Provincie Arrondissement Ste<strong>de</strong>n - Gemeenten<br />

Namen Dinant<br />

Uitsluitend Vresse-sur-Semois, Gedinne, Beauraing,<br />

Houyet, Rochefort, Bièvre<br />

Virton, Aarlen, Neufchâteau, Bastenaken Alle<br />

23<br />

Luxemburg<br />

Marche-en-Famenne<br />

Uitsluitend Marche-en-Famenne, Hotton, Erezee, Manhay,<br />

La-Roche-en-Ar<strong>de</strong>nne, Tenneville, Nassogne, Ren<strong>de</strong>ux<br />

Uitsluitend Burg-Reuland, Sankt-Vith, Amel, Bullingen,<br />

Luik Verviers<br />

Butgenbach, Waimes, Malmédy, Stavelot, Stoumont,<br />

Lierneux, Trois-Ponts<br />

Thuin Alle<br />

Uitsluitend Chapelle-lez-Herlaimont, Courcelles, Pont-à-<br />

Henegouwen<br />

Charleroi<br />

Celles, Les-Bons-Villers, Fleurus, Farciennes, Aiseau-<br />

Presles, Gerpinnes, Charleroi, Montigny-le-Tilleul,<br />

Fontaine-l’Évêque<br />

Philippeville, Namen Alle<br />

24<br />

Namen<br />

Dinant<br />

Uitsluitend Hastière, Onhaye, Yvoir, Dinant, Ciney,<br />

Hamois, Havelange, Somme-Leuze<br />

Hoei, Waremme, Luik Alle<br />

Uitsluitend Plombières, Kelmis, Lontzen, Raeren, Eupen,<br />

Luik<br />

Verviers<br />

Baelen, Jalhay, Spa, Theux, Pepinster, Olne, Herve,<br />

Aubel, Thimister-Clermont, Dison, Verviers, Umbourg,<br />

Welkenraedt<br />

Luxemburg Marche-en-Famenne Uitsluitend Durbuy<br />

Limburg Tongeren Uitsluitend Voeren<br />

West-Vlaan<strong>de</strong>ren Kortrijk Alle<br />

Oost-Vlaan<strong>de</strong>ren<br />

Aalst, Den<strong>de</strong>rmon<strong>de</strong>, Ou<strong>de</strong>naar<strong>de</strong>, Sint-<br />

Niklaas<br />

Alle<br />

25<br />

Antwerpen, Vlaams-Brabant,<br />

Waals-Brabant<br />

Alle Alle<br />

Limburg Alle Alle, uitgezon<strong>de</strong>rd Voeren<br />

Henegouwen<br />

Doornik, Ath, Soignies, Bergen<br />

Charleroi<br />

Alle<br />

Uitsluitend Seneffe en Manage<br />

26<br />

West-Vlaan<strong>de</strong>ren<br />

Henegouwen<br />

Veurne, Oosten<strong>de</strong>, Brugge, Diksmui<strong>de</strong>,<br />

Ieper, Roeselaere, Tielt<br />

Moeskroen<br />

Alle<br />

Alle<br />

Oost-Vlaan<strong>de</strong>ren Eeklo, Gent Alle<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

108


Dynamische piekdruk qp(z) (N/m²) voor vb,0 = 23 m/s.<br />

Dynamische piekdruk qp(z) (N/m²) – cprob² = 1<br />

Hoogte<br />

Terreincategoriën<br />

ze (m) I II III IV<br />

200 1595 1514 1312 1082<br />

175 1561 1477 1272 1042<br />

150 1522 1434 1226 997<br />

125 1477 1384 1173 945<br />

100 1423 1325 1110 882<br />

95 1410 1311 1096 868<br />

90 1397 1297 1081 854<br />

85 1383 1282 1065 838<br />

80 1369 1266 1048 822<br />

75 1354 1249 1031 805<br />

70 1337 1232 1012 787<br />

65 1320 1213 992 767<br />

60 1301 1192 971 747<br />

55 1281 1170 948 724<br />

50 1259 1147 923 700<br />

45 1235 1121 896 674<br />

40 1209 1092 866 646<br />

35 1179 1060 833 614<br />

30 1145 1023 795 577<br />

28 1130 1007 778 562<br />

26 1114 989 761 545<br />

24 1096 971 742 527<br />

22 1078 951 721 507<br />

20 1057 929 699 487<br />

18 1035 905 675 464<br />

16 1011 879 648 439<br />

14 983 850 619 412<br />

12 952 816 585 381<br />

10 915 778 546 345<br />

9 895 756 524 345<br />

8 872 731 500 345<br />

7 846 704 473 345<br />

6 817 674 443 345<br />

5 782 638 408 345<br />

2 621 471 408 345<br />

1 509 471 408 345<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

109


z e [m]<br />

200<br />

190<br />

180<br />

170<br />

160<br />

150<br />

140<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Druk qp met bij v b,0 = 23 m/s en cprob² = 1 (50 jaar)<br />

300 500 700 900 1100 1300 1500 1700<br />

Dynamische Piek dynasmishe piekdruk druk qp qp[N/m²] [N/m 2 ]<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

IV<br />

III<br />

II<br />

I<br />

110


Dynamische piekdruk qp(z) (N/m²) voor vb,0 = 24 m/s.<br />

Dynamische piekdruk qp(z) (N/m²) – cprob² = 1<br />

Hoogte Terreincategorieën<br />

ze (m) I II III IV<br />

200 1737 1649 1428 1178<br />

175 1700 1608 1385 1135<br />

150 1658 1561 1335 1086<br />

125 1608 1507 1278 1029<br />

100 1549 1442 1209 961<br />

95 1535 1428 1193 946<br />

90 1521 1412 1177 930<br />

85 1506 1396 1160 913<br />

80 1491 1379 1142 895<br />

75 1474 1360 1122 876<br />

70 1456 1341 1102 856<br />

65 1437 1320 1080 835<br />

60 1417 1298 1057 813<br />

55 1395 1274 1032 789<br />

50 1371 1249 1005 763<br />

45 1345 1220 976 734<br />

40 1316 1189 943 703<br />

35 1283 1154 907 668<br />

30 1246 1114 866 629<br />

28 1230 1096 847 611<br />

26 1212 1077 828 593<br />

24 1194 1057 807 573<br />

22 1173 1035 785 552<br />

20 1151 1012 761 530<br />

18 1127 986 735 505<br />

16 1100 957 706 478<br />

14 1070 925 673 448<br />

12 1036 889 637 414<br />

10 997 847 595 376<br />

9 974 823 571 376<br />

8 949 796 545 376<br />

7 921 767 516 376<br />

6 889 733 483 376<br />

5 852 695 445 376<br />

2 676 512 445 376<br />

1 554 512 445 376<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

111


z e [m]<br />

200<br />

190<br />

180<br />

170<br />

160<br />

150<br />

140<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Druk qp met bij v b,0 = 24 m/s en cprob² = 1 (50 jaar)<br />

300 500 700 900 1100 1300 1500 1700<br />

Dynamische Piek dynasmishe piekdruk druk qp<br />

qp[N/m²] WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

IV<br />

III<br />

II<br />

I<br />

112


Dynamische piekdruk qp(z) (N/m²) voor vb,0 = 25 m/s.<br />

Dynamische piekdruk qp(z) (N/m²) – cprob² = 1<br />

Hoogte Terreincategorieën<br />

ze (m) I II III IV<br />

200 1884 1789 1550 1278<br />

175 1844 1745 1503 1231<br />

150 1799 1694 1449 1178<br />

125 1745 1636 1386 1116<br />

100 1681 1565 1312 1043<br />

95 1666 1549 1295 1026<br />

90 1651 1532 1277 1009<br />

85 1634 1514 1258 990<br />

80 1617 1496 1239 971<br />

75 1599 1476 1218 951<br />

70 1580 1455 1196 929<br />

65 1559 1433 1172 907<br />

60 1537 1409 1147 882<br />

55 1514 1383 1120 856<br />

50 1488 1355 1091 828<br />

45 1459 1324 1059 797<br />

40 1428 1290 1023 763<br />

35 1393 1252 984 725<br />

30 1352 1208 939 682<br />

28 1335 1189 920 663<br />

26 1316 1169 899 643<br />

24 1295 1147 876 622<br />

22 1273 1123 852 599<br />

20 1249 1098 826 575<br />

18 1223 1070 797 548<br />

16 1194 1039 766 519<br />

14 1162 1004 731 486<br />

12 1125 965 691 450<br />

10 1081 919 645 408<br />

9 1057 893 620 408<br />

8 1030 864 591 408<br />

7 999 832 559 408<br />

6 965 796 524 408<br />

5 924 754 482 408<br />

2 733 556 482 408<br />

1 602 556 482 408<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

113


z e [m]<br />

200<br />

190<br />

180<br />

170<br />

160<br />

150<br />

140<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Druk qp bij met v b,0 = 25 m/s en cprob² = 1 (50 jaar)<br />

400 600 800 1000 1200 1400 1600 1800<br />

Dynamische Piek dynasmishe piekdruk druk qp<br />

qp[N/m²] WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

IV<br />

III<br />

II<br />

I<br />

114


Dynamische piekdruk qp(z) (N/m²) voor vb,0 = 26 m/s.<br />

Dynamische piekdruk qp(z) (N/m²) – cprob² = 1<br />

Hoogte<br />

Terreincategorieën<br />

ze (m) 0 I II III IV<br />

200 2069 2038 1935 1676 1383<br />

175 2029 1995 1887 1625 1332<br />

150 1983 1945 1833 1567 1274<br />

125 1930 1887 1769 1500 1207<br />

100 1866 1818 1693 1419 1128<br />

95 1851 1802 1675 1400 1110<br />

90 1836 1785 1657 1381 1091<br />

85 1819 1768 1638 1361 1071<br />

80 1802 1749 1618 1340 1050<br />

75 1784 1730 1597 1317 1028<br />

70 1765 1709 1574 1293 1005<br />

65 1744 1687 1550 1268 980<br />

60 1722 1663 1524 1241 954<br />

55 1698 1637 1496 1212 926<br />

50 1672 1609 1465 1180 895<br />

45 1644 1578 1432 1145 862<br />

40 1612 1544 1395 1107 825<br />

35 1576 1506 1354 1064 784<br />

30 1536 1463 1307 1016 738<br />

28 1518 1444 1286 995 718<br />

26 1499 1423 1264 972 696<br />

24 1478 1401 1240 948 673<br />

22 1456 1377 1215 921 648<br />

20 1431 1351 1187 893 622<br />

18 1405 1323 1157 862 593<br />

16 1376 1291 1123 828 561<br />

14 1343 1256 1086 790 526<br />

12 1305 1216 1043 748 486<br />

10 1261 1170 994 698 441<br />

9 1236 1143 966 670 441<br />

8 1208 1114 935 639 441<br />

7 1177 1081 900 605 441<br />

6 1142 1043 861 566 441<br />

5 1100 1000 815 522 441<br />

2 903 793 601 522 441<br />

1 765 651 601 522 441<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

115


z e [m]<br />

200<br />

190<br />

180<br />

170<br />

160<br />

150<br />

140<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Druk qp bij met v b,0 = 26 m/s en cprob² = 1 (50 jaar)<br />

IV III II I 0<br />

400 600 800 1000 1200 1400 1600 1800 2000<br />

Piek Dynamische dynasmishe piekdruk druk qqp p[N/m²]<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

116


BIJLAGE 2<br />

BEPALING VAN DE MEEST ONGUNSTIGE<br />

BUITENDRUKCOËFFICIËNTEN cpe VOOR EEN GEVEL<br />

Uitgaan<strong>de</strong> <strong>van</strong> <strong>de</strong> zones A, B, C en D uit afbeelding 21, kan men voor <strong>de</strong> drie windrichtingen<br />

θ = 0°, 90° en 90°(+) zeven zones on<strong>de</strong>rschei<strong>de</strong>n met verschillen<strong>de</strong> belastingscombinaties. Deze<br />

wor<strong>de</strong>n voorgesteld in <strong>de</strong> volgen<strong>de</strong> afbeelding, waarbij :<br />

• d : <strong>de</strong> lengte <strong>van</strong> <strong>de</strong> puntgevel, evenwijdig met <strong>de</strong> wind<br />

• e : <strong>de</strong> minimale waar<strong>de</strong> <strong>van</strong> b en 2h.<br />

Wind θ = 0°<br />

Vent Vent Vent θ θ θ = = = 0° 0° 0°<br />

1<br />

Vent Vent θ θ = = 90° 90° (+) (+)<br />

Geval Cas 1 waarbij ei 1 e i < d d< di<br />

i<br />

2<br />

3 4<br />

Vent Vent Vent θ θ θ = = = 90° 90° 90°<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

7<br />

b<br />

5<br />

6<br />

Geval Cas 3 waarbij 3 où e i<br />

ei 5d ≥ 5di i<br />

Geval Cas 2 2 où waarbij e i d <strong>de</strong>i i ≥ di<br />

Aan <strong>de</strong> hand <strong>van</strong> tabel 4 wor<strong>de</strong>n in <strong>de</strong> volgen<strong>de</strong> tabellen cpe-waar<strong>de</strong>n geformuleerd voor <strong>de</strong> drie<br />

windrichtingen.<br />

1. Geval e < d<br />

Wind θ =<br />

90°(+)<br />

Wind θ =<br />

90 °<br />

Tabel A2.1 cpe,10-coëfficiënten <strong>van</strong> <strong>de</strong> zones voor <strong>de</strong> windrichtingen θ = 0°, θ = 90° en θ = 90°(+).<br />

h/d = 5 - cpe,10 h/d = 1 - cpe,10 h/d ≤ 0,25 - cpe,10<br />

Zone Wind Wind Wind Wind Wind Wind Wind Wind Wind<br />

θ = 0° θ = 90° θ = 90°(+) θ = 0° θ = 90° θ = 90°(+) θ = 0° θ = 90° θ = 90°(+)<br />

1. D0 = 0,8 B90 = -0,8 B90 = -0,8 D0 = 0,8 B90 = -0,8 B90 = -0,8 D0 = 0,7 B90 = -0,8 B90 = -0,8<br />

2. D0 = 0,8 A90 = -1,2 C90 = -0,5 D0 = 0,8 A90 = -1,2 C90 = -0,5 D0 = 0,7 A90 = -1,2 C90 = -0,5<br />

3. A0 = -1,2 D90 = 0,8 E90 = -0,7 A0 = -1,2 D90 = 0,8 E90 = -0,5 A0 = -1,2 D90 = 0,7 E90 = -0,3<br />

4. B0 = -0,8 D90 = 0,8 E90 = -0,7 B0 = -0,8 D90 = 0,8 E90 = -0,5 B0 = -0,8 D90 = 0,7 E90 = -0,3<br />

5. C0 = -0,5 D90 = 0,8 E90 = -0,7 C0 = -0,5 D90 = 0,8 E90 = -0,5 A0 = -1,2 D90 = 0,7 E90 = -0,3<br />

6. E0 = -0,7 A90 = -1,2 C90 = -0,5 E0 = -0,5 A90 = -1,2 C90 = -0,5 E0 = -0,3 A90 = -1,2 C90 = -0,5<br />

7. E0 = -0,7 B90 = -0,8 B90 = -0,8 E0 = -0,5 B90 = -0,8 B90 = -0,8 E0 = -0,3 A90 = -0,8 B90 = -0,8<br />

3<br />

3<br />

d<br />

4<br />

h<br />

117


Tabel A2.2 cpe,1-coëfficiënten <strong>van</strong> <strong>de</strong> zones voor <strong>de</strong> windrichtingen θ = 0°, θ = 90° en θ = 90°(+).<br />

h/d = 5 - cpe,1 h/d = 1 - cpe,1 h/d ≤ 0,25 - cpe,1<br />

Zone Wind Wind Wind Wind Wind Wind Wind Wind Wind<br />

θ = 0° θ = 90° θ = 90°(+) θ = 0° θ = 90° θ = 90°(+) θ = 0° θ = 90° θ = 90°(+)<br />

1. D0 =1,0 B90 = -1,1 B90 = -1,1 D0 =1,0 B90 = -1,1 B90 = -1,1 D0 =1,0 B90 = -1,1 B90 = -1,1<br />

2. D0 =1,0 A90 = -1,4 C90 = -0,5 D0 =1,0 A90 = -1,4 C90 = -0,5 D0 =1,0 A90 = -1,4 C90 = -0,5<br />

3. A0 = -1,4 D90 =1,0 E90 = -0,7 A0 = -1,4 D90 =1,0 E90 = -0,5 A0 = -1,4 D90 =1,0 E90 = -0,3<br />

4. B0 = -1,1 D90 =1,0 E90 = 0,7 B0 = -1,1 D90 =1,0 E90 = -0,5 B0 = -1,1 D90 =1,0 E90 = -0,3<br />

5. C0 = -0,5 D90 =1,0 E90 = -0,7 C0 = -0,5 D90 =1,0 E90 = -0,5 C0 = -0,5 D90 =1,0 E90 = -0,3<br />

6. E0 = -0,7 A90 = -1,4 C90 = -0,5 E0 = -0,5 A90 = -1,4 C90 = -0,5 E0 = -0,3 A90 = -1,4 C90 = -0,5<br />

7. E0 = -0,7 B90 = -1,1 B90 = -1,1 E0 = -0,5 B90 = -1,1 B90 = -1,1 E0 = -0,3 A90 = -1,1 B90 = -1,1<br />

2. Geval e ≥ d<br />

Tabel A2.3 cpe,10-coëfficiënten <strong>van</strong> <strong>de</strong> zones voor <strong>de</strong> windrichtingen θ = 0°, θ = 90° en θ = 90°(+).<br />

h/d = 5 - cpe,10 h/d = 1 - cpe,10 h/d ≤ 0,25 - cpe,10<br />

Zone Wind Wind Wind Wind Wind Wind Wind Wind Wind<br />

θ = 0° θ = 90° θ = 90°(+) θ = 0° θ = 90° θ = 90°(+) θ = 0° θ = 90° θ = 90°(+)<br />

1. D0 = 0,8 B90 = -0,8 B90 = -0,8 D0 = 0,8 B90 = -0,8 B90 = -0,8 D0 = 0,7 B90 = -0,8 B90 = -0,8<br />

2. D0 = 0,8 A90 = -1,2 B90 = -0,8 D0 = 0,8 A90 = -1,2 B90 = -0,8 D0 = 0,7 A90 = -1,2 B90 = -0,8<br />

3. A0 = -1,2 D90 = 0,8 E90 = -0,7 A0 = -1,2 D90 = 0,8 E90 = -0,5 A0 = -1,2 D90 = 0,7 E90 = -0,3<br />

4. B0 = -0,8 D90 = 0,8 E90 = -0,7 B0 = -0,8 D90 = 0,8 E90 = -0,5 B0 = -0,8 D90 = 0,7 E90 = -0,3<br />

5. B0 = -0,8 D90 = 0,8 E90 = -0,7 B0 = -0,8 D90 = 0,8 E90 = -0,5 B0 = -0,8 D90 = 0,7 E90 = -0,3<br />

6. E0 = -0,7 A90 = -1,2 B90 = -0,8 E0 = -0,5 A90 = -1,2 B90 = -0,8 E0 = -0,3 A90 = -1,2 B90 = -0,8<br />

7. E0 = -0,7 B90 = -0,8 B90 = -0,8 E0 = -0,5 B90 = -0,8 B90 = -0,8 E0 = -0,3 A90 = -0,8 B90 = -0,8<br />

Tabel A2.4 cpe,1-coëfficiënten <strong>van</strong> <strong>de</strong> zones voor <strong>de</strong> windrichtingen θ = 0°, θ = 90° en θ = 90°(+).<br />

h/d = 5 - cpe,1 h/d = 1 - cpe,1 h/d ≤ 0,25 - cpe,1<br />

Zone Wind Wind Wind Wind Wind Wind Wind Wind Wind<br />

θ = 0° θ = 90° θ = 90°(+) θ = 0° θ = 90° θ = 90 (+) θ = 0° θ = 90° θ = 90°(+)<br />

1. D0 =1,0 B90 = -1,1 B90 = -1,1 D0 =1,0 B90 = -1,1 B90 = -1,1 D0 =1,0 B90 = -1,1 B90 = -1,1<br />

2. D0 =1,0 A90 = -1,4 B90 = -1,1 D0 =1,0 A90 = -1,4 B90 = -1,1 D0 =1,0 A90 = -1,4 B90 = -1,1<br />

3. A0 = -1,4 D90 =1,0 E90 = -0,7 A0 = -1,4 D90 =1,0 E90 = -0,5 A0 = -1,4 D90 =1,0 E90 = -0,3<br />

4. B0 = -1,1 D90 =1,0 E90 = 0,7 B0 = -1,1 D90 =1,0 E90 = -0,5 B0 = -1,1 D90 =1,0 E90 = -0,3<br />

5. B0 = -1,1 D90 =1,0 E90 = -0,7 B0 = -1,1 D90 =1,0 E90 = -0,5 B0 = -1,1 D90 =1,0 E90 = -0,3<br />

6. E0 = -0,7 A90 = -1,4 B90 = -1,1 E0 = -0,5 A90 = -1,4 B90 = -1,1 E0 = -0,3 A90 = -1,4 B90 = -1,1<br />

7. E0 = -0,7 B90 = -1,1 B90 = -1,1 E0 = -0,5 B90 = -1,1 B90 = -1,1 E0 = -0,3 A90 = -1,1 B90 = -1,1<br />

3. Geval e ≥ 5d<br />

Tabel A2.5 cpe,10-coëfficiënten <strong>van</strong> <strong>de</strong> zones voor <strong>de</strong> windrichtingen θ = 0°, θ = 90° en θ = 90°(+).<br />

h/d = 5 - cpe,10 h/d = 1 - cpe,10 h/d ≤ 0,25 - cpe,10<br />

Zone Wind Wind Wind Wind Wind Wind Wind Wind Wind<br />

θ = 0° θ = 90° θ = 90°(+) θ = 0° θ = 90° θ = 90°(+) θ = 0° θ = 90° θ = 90°(+)<br />

1. D0 = 0,8 A90 = -1,2 A90 = -1,2 D0 = 0,8 A90 = -1,2 A90 = -1,2 D0 = 0,7 A90 = -1,2 A90 = -1,2<br />

2. D0 = 0,8 A90 = -1,2 A90 = -1,2 D0 = 0,8 A90 = -1,2 A90 = -1,2 D0 = 0,7 A90 = -1,2 A90 = -1,2<br />

3. A0 = -1,2 D90 = 0,8 E90 = -0,7 A0 = -1,2 D90 = 0,8 E90 = -0,5 A0 = -1,2 D90 = 0,7 E90 = -0,3<br />

4. A0 = -1,2 D90 = 0,8 E90 = -0,7 A0 = -1,2 D90 = 0,8 E90 = -0,5 A0 = -1,2 D90 = 0,7 E90 = -0,3<br />

5. A0 = -1,2 D90 = 0,8 E90 = -0,7 A0 = -1,2 D90 = 0,8 E90 = -0,5 A0 = -1,2 D90 = 0,7 E90 = -0,3<br />

6. E0 = -0,7 A90 = -1,2 A90 = -1,2 E0 = -0,5 A90 = -1,2 A90 = -1,2 E0 = -0,3 A90 = -1,2 A90 = -1,2<br />

7. E0 = -0,7 A90 = -1,2 A90 = -1,2 E0 = -0,5 A90 = -1,2 A90 = -1,2 E0 = -0,3 A90 = -1,2 A90 = -1,2<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

118


Tabel A2.6 cpe,1-coëfficiënten <strong>van</strong> <strong>de</strong> zones voor <strong>de</strong> windrichtingen θ = 0°, θ = 90° en θ = 90°(+).<br />

h/d = 5 - cpe,1 h/d = 1 - cpe,1 h/d ≤ 0,25 - cpe,1<br />

Zone Wind Wind Wind Wind Wind Wind Wind Wind Wind<br />

θ = 0° θ = 90° θ = 90°(+) θ = 0° θ = 90° θ = 90°(+) θ = 0° θ = 90° θ = 90°(+)<br />

1. D0 = 1,0 A90 = -1,4 A90 = -1,4 D0 = 1,0 A90 = -1,4 A90 = -1,4 D0 = 1,0 A90 = -1,4 A90 = -1,4<br />

2. D0 = 1,0 A90 = -1,4 A90 = -1,4 D0 = 1,0 A90 = -1,4 A90 = -1,4 D0 = 1,0 A90 = -1,4 A90 = -1,4<br />

3. A0 = -1,4 D90 = 1,0 E90 = -0,7 A0 = -1,4 D90 = 1,0 E90 = -0,5 A0 = -1,4 D90 = 1,0 E90 = -0,3<br />

4. A0 = -1,4 D90 = 1,0 E90 = -0,7 A0 = -1,4 D90 = 1,0 E90 = -0,5 A0 = -1,4 D90 = 1,0 E90 = -0,3<br />

5. A0 = -1,4 D90 = 1,0 E90 = -0,7 A0 = -1,4 D90 = 1,0 E90 = -0,5 A0 = -1,4 D90 = 1,0 E90 = -0,3<br />

6. E0 = -0,7 A90 = -1,4 A90 = -1,4 E0 = -0,5 A90 = -1,4 A90 = -1,4 E0 = -0,3 A90 = -1,4 A90 = -1,4<br />

7. E0 = -0,7 A90 = -1,4 A90 = -1,4 E0 = -0,5 A90 = -1,4 A90 = -1,4 E0 = -0,3 A90 = -1,4 A90 = -1,4<br />

De meest ongunstige situaties uit <strong>de</strong> volgen<strong>de</strong> tabellen resulteren uit <strong>de</strong> vergelijking <strong>van</strong> <strong>de</strong><br />

cpe-coëfficiënten <strong>van</strong> <strong>de</strong> zones 1 en 7; 2 en 6; 3 en 5; 1 en 4 en 2 en 3, zoals geïllustreerd in <strong>de</strong><br />

volgen<strong>de</strong> afbeelding.<br />

h<br />

Wind Wind Wind θ θ θ = = = 0° 0° 0°<br />

ee e90°/5 90°/5 90°/5<br />

bb 0° 0° / / d d 90° 90°<br />

Voor <strong>de</strong> cpe,10-coëfficiënten<br />

11<br />

22<br />

ee 90° 90° /5 /5<br />

3 4<br />

e 0° /5<br />

d 0° / b 90°<br />

Wind Wind Wind θ θ θ = = = 90° 90° 90°<br />

11 22<br />

b i = richting loodrecht<br />

bi = richting<br />

<strong>op</strong> <strong>de</strong> windrichting i<br />

loodrecht <strong>op</strong> <strong>de</strong><br />

e i =<br />

windrichting<br />

minimum<br />

i<br />

tussen b i en 2h<br />

ei = minimum <strong>van</strong><br />

bi en 2h<br />

e e0°/5 0°/5<br />

Tabel A2.7 Vergelijking <strong>van</strong> <strong>de</strong> cpe,10-coëfficiënten voor 0,25 < h/d < 5.<br />

cpe,10 voor 0,25 < h/d < 5<br />

Zone Eerste<br />

vergelijking<br />

1<br />

7<br />

1<br />

4 4<br />

2<br />

6<br />

2<br />

3<br />

5<br />

3<br />

Twee<strong>de</strong><br />

vergelijking<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

1<br />

2<br />

3<br />

Resultaat<br />

Gevallen 1 en 2<br />

(e < 5d)<br />

cpe = -0,8<br />

cpe = 0,8<br />

cpe = -1,2<br />

cpe = 0,8<br />

Resultaat<br />

Geval 3<br />

(e ≥ 5d)<br />

cpe = -1,2<br />

cpe = 0,8<br />

119


Tabel A2.8 Vergelijking <strong>van</strong> <strong>de</strong> cpe,10-coëfficiënten voor h/d ≤ 0,25.<br />

cpe,10 voor h/d ≤ 0,25<br />

Zone Eerste<br />

vergelijking<br />

1<br />

7<br />

1<br />

4 4<br />

2<br />

6<br />

2<br />

3<br />

5<br />

3<br />

Twee<strong>de</strong><br />

vergelijking<br />

Resultaat<br />

Gevallen 1 en 2<br />

(e < 5d)<br />

Resultaat<br />

Geval 3<br />

(e ≥ 5d)<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

1<br />

2<br />

cpe = -0,8<br />

cpe = 0,7<br />

cpe = -1,2<br />

cpe = 0,7<br />

Dit resulteert in <strong>de</strong> gegevens, <strong>op</strong>genomen in <strong>de</strong> volgen<strong>de</strong> tabel.<br />

Tabel A2.9 Resultaten, verkregen voor cpe,10.<br />

Zone<br />

1<br />

2<br />

cpe,10 voor 0,25 < h/d < 5 cpe,10 voor h/d ≤ 0,25<br />

cpe = -1,2<br />

cpe = 0,7<br />

e < 5d e ≥ 5d e < 5d e ≥ 5d<br />

cpe = -0,8<br />

cpe = 0,8<br />

cpe = -1,2<br />

cpe = 0,8<br />

Voor <strong>de</strong> cpe,1-coëfficiënten<br />

cpe = -1,2<br />

cpe = -0,8<br />

cpe = 0,7<br />

cpe = 0,8 cpe = -1,2<br />

cpe = 0,7<br />

Tabel A2.10 Vergelijking <strong>van</strong> <strong>de</strong> cpe,1-coëfficiënten voor 0,25 < h/d < 5.<br />

cpe,1 voor 0,25 < h/d < 5<br />

Zone Eerste<br />

vergelijking<br />

1<br />

7<br />

1<br />

4 4<br />

2<br />

6<br />

2<br />

3<br />

5<br />

3<br />

Twee<strong>de</strong><br />

vergelijking<br />

1<br />

2<br />

Resultaat<br />

Gevallen 1 en 2<br />

(e < 5d)<br />

cpe = -1,1<br />

cpe = 1,0<br />

cpe = -1,4<br />

cpe = 1,0<br />

Tabel A2.11 Vergelijking <strong>van</strong> <strong>de</strong> cpe,1-coëfficiënten voor h/d ≤ 0,25.<br />

cpe,1 voor h/d ≤ 0,25<br />

Zone Eerste<br />

vergelijking<br />

1<br />

7<br />

1<br />

4 4<br />

2<br />

6<br />

2<br />

3<br />

5<br />

3<br />

Twee<strong>de</strong><br />

vergelijking<br />

1<br />

2<br />

Resultaat<br />

Gevallen 1 en 2<br />

(e < 5d)<br />

cpe = -1,1<br />

cpe = 1,0<br />

cpe = -1,4<br />

cpe = 1;0<br />

Dit resulteert in <strong>de</strong> gegevens, <strong>op</strong>genomen in <strong>de</strong> volgen<strong>de</strong> tabel.<br />

cpe = -1,2<br />

cpe = 0,7<br />

Resultaat<br />

Geval 3<br />

(e ≥ 5d)<br />

cpe = -1,4<br />

cpe = 1,0<br />

Resultaat<br />

Geval 3<br />

(e ≥ 5d)<br />

cpe = -1,4<br />

cpe = 1,0<br />

120


Tabel A2.12 Resultaten, verkregen voor cpe,1.<br />

cpe,1 voor h/d < 5<br />

Zone<br />

e < 5d e ≥ 5d<br />

1<br />

2<br />

cpe = -1,1<br />

cpe = 1,0<br />

cpe = -1,4<br />

cpe = 1,0<br />

Zie ook tabel 5 en tabel 6.<br />

cpe = -1,4<br />

cpe = 1,0<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

121


BIJLAGE 3<br />

BEPALING VAN DE MEEST ONGUNSTIGE<br />

BUITENDRUKCOËFFICIËNTEN cpe VOOR DAKEN MET ÉÉN ENKEL<br />

DAKSCHILD<br />

A.3.1 Bepaling <strong>van</strong> <strong>de</strong> cpe,10-coëfficiënten<br />

Uitgaan<strong>de</strong> <strong>van</strong> <strong>de</strong> zones F, G, H en I uit afbeelding 25 en <strong>de</strong> vier gecombineer<strong>de</strong> windrichtingen<br />

θ = 0°, 90°, 90°(+) en 180° uit afbeelding 26, kan men in afbeelding 27 tien zones on<strong>de</strong>rschei<strong>de</strong>n<br />

met verschillen<strong>de</strong> belastingscombinaties. Dankzij dit schema was <strong>het</strong> mogelijk <strong>de</strong> cpe,1- en cpe,10coëfficiënten<br />

te bepalen voor een hoek <strong>van</strong> 5°, 15°, 30°, 45°, 60° en 75° (zie tabel A3.1).<br />

Tabel A3.1 Drukzones voor <strong>de</strong> windrichtingen θ = 0°, θ = 90°, θ = 90°(+) en θ = 180°.<br />

Zone Wind θ = 0° Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 H90 H180 I90<br />

2. F0 H90 H180 I90<br />

3. F0 F90 inf H180 I90<br />

4. H0 F90 inf H180 I90<br />

5. H0 G90 H180 I90<br />

6. H0 F90 sup H180 I90<br />

7. H0 F90 sup F180 I90<br />

8. H0 H90 F180 I90<br />

9. H0 H90 G180 I90<br />

10. H0 H90 H180 I90<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> 5°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 -1,2 +0,0 H90 -0,6 H180 -0,8 I90 -0,5<br />

2. F0 -1,7 +0,0 H90 -0,6 H180 -0,8 I90 -0,5<br />

3. F0 -1,7 +0,0 F90 inf -2,1 H180 -0,8 I90 -0,5<br />

4. H0 - 0,6 +0,0 F90 inf -2,1 H180 -0,8 I90 -0,5<br />

5. H0 - 0,6 +0,0 G90 -1,8 H180 -0,8 I90 -0,5<br />

6. H0 - 0,6 +0,0 F90 sup -2,1 H180 -0,8 I90 -0,5<br />

7. H0 - 0,6 +0,0 F90 sup -2,1 F180 -2,3 I90 -0,5<br />

8. H0 - 0,6 +0,0 H90 -0,6 F180 -2,3 I90 -0,5<br />

9. H0 - 0,6 +0,0 H90 -0,6 G180 - 1,3 I90 -0,5<br />

10. H0 - 0,6 +0,0 H90 -0,6 H180 -0,8 I90 -0,5<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> 15°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 -0,8 +0,2 H90 -0,8 H180 -0,9 I90 -0,7<br />

2. F0 -0,9 +0,2 H90 -0,8 H180 -0,9 I90 -0,7<br />

3. F0 -0,9 +0,2 F90 inf -1,6 H180 -0,9 I90 -0,7<br />

4. H0 -0,3 +0,2 F90 inf -1,6 H180 -0,9 I90 -0,7<br />

5. H0 -0,3 +0,2 G90 -1,9 H180 -0,9 I90 -0,7<br />

6. H0 -0,3 +0,2 F90 sup -2,4 H180 -0,9 I90 -0,7<br />

7. H0 -0,3 +0,2 F90 sup -2,4 F180 -2,5 I90 -0,7<br />

8. H0 -0,3 +0,2 H90 -0,8 F180 -2,5 I90 -0,7<br />

9. H0 -0,3 +0,2 H90 -0,8 G180 -1,3 I90 -0,7<br />

10. H0 -0,3 +0,2 H90 -0,8 H180 -0,9 I90 -0,8<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

122


Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> 30°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 -0,5 +0,7 H90 -1,0 H180 -0,8 I90 -0,8<br />

2. F0 -0,5 +0,7 H90 -1,0 H180 -0,8 I90 -0,8<br />

3. F0 -0,5 +0,7 F90 inf -1,3 H180 -0,8 I90 -0,8<br />

4. H0 -0,2 +0,4 F90 inf -1,3 H180 -0,8 I90 -0,8<br />

5. H0 -0,2 +0,4 G90 -1,5 H180 -0,8 I90 -0,8<br />

6. H0 -0,2 +0,4 F90 sup -2,1 H180 -0,8 I90 -0,8<br />

7. H0 -0,2 +0,4 F90 sup -2,1 F180 -1,1 I90 -0,8<br />

8. H0 -0,2 +0,4 H90 -1,0 F180 -1,1 I90 -0,8<br />

9. H0 -0,2 +0,4 H90 -1,0 G180 -0,8 I90 -0,8<br />

10. H0 -0,2 +0,4 H90 -1,0 H180 -0,8 I90 -1,0<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> 45°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 -0,0 +0,7 H90 -1,0 H180 -0,7 I90 -0,9<br />

2. F0 -0,0 +0,7 H90 -1,0 H180 -0,7 I90 -0,9<br />

3. F0 -0,0 +0,7 F90 inf -1,3 H180 -0,7 I90 -0,9<br />

4. H0 -0,0 +0,6 F90 inf -1,3 H180 -0,7 I90 -0,9<br />

5. H0 -0,0 +0,6 G90 -1,4 H180 -0,7 I90 -0,9<br />

6. H0 -0,0 +0,6 F90 sup -1,5 H180 -0,7 I90 -0,9<br />

7. H0 -0,0 +0,6 F90 sup -1,5 F180 -0,6 I90 -0,9<br />

8. H0 -0,0 +0,6 H90 -1,0 F180 -0,6 I90 -0,9<br />

9. H0 -0,0 +0,6 H90 -1,0 G180 -0,5 I90 -0,9<br />

10. H0 -0,0 +0,6 H90 -1,0 H180 -0,7 I90 -0,9<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> 60°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 +0,7 H90 -1,0 H180 -0,5 I90 -0,7<br />

2. F0 +0,7 H90 -1,0 H180 -0,5 I90 -0,7<br />

3. F0 +0,7 F90 inf -1,2 H180 -0,5 I90 -0,7<br />

4. H0 +0,7 F90 inf -1,2 H180 -0,5 I90 -0,7<br />

5. H0 +0,7 G90 -1,2 H180 -0,5 I90 -0,7<br />

6. H0 +0,7 F90 sup -1,2 H180 -0,5 I90 -0,7<br />

7. H0 +0,7 F90 sup -1,2 F180 -0,5 I90 -0,7<br />

8. H0 +0,7 H90 -1,0 F180 -0,5 I90 -0,7<br />

9. H0 +0,7 H90 -1,0 G180 -0,5 I90 -0,7<br />

10. H0 +0,7 H90 -1,0 H180 -0,5 I90 -0,7<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> 75°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 +0,8 H90 -1,0 H180 -0,5 I90 -0,5<br />

2. F0 +0,8 H90 -1,0 H180 -0,5 I90 -0,5<br />

3. F0 +0,8 F90 inf -1,2 H180 -0,5 I90 -0,5<br />

4. H0 +0,8 F90 inf -1,2 H180 -0,5 I90 -0,5<br />

5. H0 +0,8 G90 -1,2 H180 -0,5 I90 -0,5<br />

6. H0 +0,8 F90 sup -1,2 H180 -0,5 I90 -0,5<br />

7. H0 +0,8 F90 sup -1,2 F180 -0,5 I90 -0,5<br />

8. H0 +0,8 H90 -1,0 F180 -0,5 I90 -0,5<br />

9. H0 +0,8 H90 -1,0 G180 -0,5 I90 -0,5<br />

10. H0 +0,8 H90 -1,0 H180 -0,5 I90 -0,5<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

123


A.3.2 Bepaling <strong>van</strong> <strong>de</strong> cpe,1-coëfficiënten<br />

De tabellen met <strong>de</strong> cpe,1-coëfficiënten wer<strong>de</strong>n verkregen door <strong>het</strong> volgen <strong>van</strong> <strong>de</strong>zelf<strong>de</strong> re<strong>de</strong>nering<br />

als voor <strong>de</strong> cpe,10-coëfficiënten.<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> 5°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 -2,0 +0,0 H90 -1,2 H180 -1,2 I90 -0,5<br />

2. F0 -2,5 +0,0 H90 -1,2 H180 -1,2 I90 -0,5<br />

3. F0 -2,5 +0,0 F90 inf -2,4 H180 -1,2 I90 -0,5<br />

4. H0 -1,2 +0,0 F90 inf -2,4 H180 -1,2 I90 -0,5<br />

5. H0 -1,2 +0,0 G90 -2,0 H180 -1,2 I90 -0,5<br />

6. H0 -1,2 +0,0 F90 sup -2,6 H180 -1,2 I90 -0,5<br />

7. H0 -1,2 +0,0 F90 sup -2,6 F180 -2,5 I90 -0,5<br />

8. H0 -1,2 +0,0 H90 -1,2 F180 -2,5 I90 -0,5<br />

9. H0 -1,2 +0,0 H90 -1,2 G180 -2,0 I90 -0,5<br />

10. H0 -1,2 +0,0 H90 -1,2 H180 -1,2 I90 -0,5<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> 15°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 -1,5 + 0,2 H90 -1,2 H180 -1,2 I90 -1,2<br />

2. F0 -2,0 + 0,2 H90 -1,2 H180 -1,2 I90 -1,2<br />

3. F0 -2,0 + 0,2 F90 inf -2,4 H180 -1,2 I90 -1,2<br />

4. H0 -0,3 + 0,2 F90 inf -2,4 H180 -1,2 I90 -1,2<br />

5. H0 -0,3 + 0,2 G90 -2,5 H180 -1,2 I90 -1,2<br />

6. H0 -0,3 + 0,2 F90 sup -2,9 H180 -1,2 I90 -1,2<br />

7. H0 -0,3 + 0,2 F90 sup -2,9 F180 -2,8 I90 -1,2<br />

8. H0 -0,3 + 0,2 H90 -1,2 F180 -2,8 I90 -1,2<br />

9. H0 -0,3 + 0,2 H90 -1,2 G180 -2,0 I90 -1,2<br />

10. H0 -0,3 + 0,2 H90 -1,2 H180 -1,2 I90 -1,2<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> 30°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 - 1,5 + 0,7 H90 -1,3 H180 -0,8 I90 -1,2<br />

2. F0 - 1,5 + 0,7 H90 -1,3 H180 -0,8 I90 -1,2<br />

3. F0 - 1,5 + 0,7 F90 inf -2,0 H180 -0,8 I90 -1,2<br />

4. H0 - 0,2 + 0,4 F90 inf -2,0 H180 -0,8 I90 -1,2<br />

5. H0 - 0,2 + 0,4 G90 -2,0 H180 -0,8 I90 -1,2<br />

6. H0 - 0,2 + 0,4 F90 sup -2,9 H180 -0,8 I90 -1,2<br />

7. H0 - 0,2 + 0,4 F90 sup -2,9 F180 -2,3 I90 -1,2<br />

8. H0 - 0,2 + 0,4 H90 -1,3 F180 -2,3 I90 -1,2<br />

9. H0 - 0,2 + 0,4 H90 -1,3 G180 -1,5 I90 -1,2<br />

10. H0 - 0,2 + 0,4 H90 -1,3 H180 -0,8 I90 -1,2<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

124


Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> 45°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 -0,0 + 0,7 H90 -1,3 H180 -0,7 I90 -1,2<br />

2. F0 -0,0 + 0,7 H90 -1,3 H180 -0,7 I90 -1,2<br />

3. F0 -0,0 + 0,7 F90 inf -2,0 H180 -0,7 I90 -1,2<br />

4. H0 -0,0 + 0,6 F90 inf -2,0 H180 -0,7 I90 -1,2<br />

5. H0 -0,0 + 0,6 G90 -2,0 H180 -0,7 I90 -1,2<br />

6. H0 -0,0 + 0,6 F90 sup -2,4 H180 -0,7 I90 -1,2<br />

7. H0 -0,0 + 0,6 F90 sup -2,4 F180 -1,3 I90 -1,2<br />

8. H0 -0,0 + 0,6 H90 -1,3 F180 -1,3 I90 -1,2<br />

9. H0 -0,0 + 0,6 H90 -1,3 G180 -0,5 I90 -1,2<br />

10. H0 -0,0 + 0,6 H90 -1,3 H180 -0,7 I90 -1,2<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> 60°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 + 0,7 H90 -1,3 H180 -0,5 I90 -1,2<br />

2. F0 + 0,7 H90 -1,3 H180 -0,5 I90 -1,2<br />

3. F0 + 0,7 F90 inf -2,0 H180 -0,5 I90 -1,2<br />

4. H0 + 0,7 F90 inf -2,0 H180 -0,5 I90 -1,2<br />

5. H0 + 0,7 G90 -2,0 H180 -0,5 I90 -1,2<br />

6. H0 + 0,7 F90 sup -2,0 H180 -0,5 I90 -1,2<br />

7. H0 + 0,7 F90 sup -2,0 F180 -1,0 I90 -1,2<br />

8. H0 + 0,7 H90 -1,3 F180 -1,0 I90 -1,2<br />

9. H0 + 0,7 H90 -1,3 G180 -0,5 I90 -1,2<br />

10. H0 + 0,7 H90 -1,3 H180 -0,5 I90 -1,2<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> 75°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1. G0 + 0,8 H90 -1,3 H180 -0,5 I90 -0,5<br />

2. F0 + 0,8 H90 -1,3 H180 -0,5 I90 -0,5<br />

3. F0 + 0,8 F90 inf -2,0 H180 -0,5 I90 -0,5<br />

4. H0 + 0,8 F90 inf -2,0 H180 -0,5 I90 -0,5<br />

5. H0 + 0,8 G90 -2,0 H180 -0,5 I90 -0,5<br />

6. H0 + 0,8 F90 sup -2,0 H180 -0,5 I90 -0,5<br />

7. H0 + 0,8 F90 sup -2,0 F180 -1,0 I90 -0,5<br />

8. H0 + 0,8 H90 -1,3 F180 -1,0 I90 -0,5<br />

9. H0 + 0,8 H90 -1,3 G180 -0,5 I90 -0,5<br />

10. H0 + 0,8 H90 -1,3 H180 -0,5 I90 -0,5<br />

De diagrammen uit afbeelding 28 wer<strong>de</strong>n <strong>op</strong>gesteld door voor eenzelf<strong>de</strong> zone <strong>de</strong> cpe,10- en cpe,1waar<strong>de</strong>n<br />

te nemen <strong>van</strong> <strong>de</strong> verschillen<strong>de</strong> dakhellingen.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

125


BIJLAGE 4<br />

BEPALING VAN DE MEEST ONGUNSTIGE<br />

BUITENDRUKCOËFFICIËNTEN cpe VOOR DAKEN MET TWEE<br />

DAKSCHILDEN<br />

Uitgaan<strong>de</strong> <strong>van</strong> <strong>de</strong> zones F, G, H, I en J uit afbeelding 29 en <strong>de</strong> vier windrichtingen θ = 0°, 90°,<br />

90°(+) en 180°, en gelet <strong>op</strong> <strong>de</strong> symmetrie <strong>van</strong> <strong>de</strong> belastingen en <strong>de</strong> windwerking, was <strong>het</strong><br />

mogelijk acht zones met een verschillen<strong>de</strong> belastingscombinatie te on<strong>de</strong>rschei<strong>de</strong>n (afbeelding 30<br />

en tabel 10).<br />

Zone Wind θ = 0° Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 H90 I180 I90<br />

2 F0 H90 I180 I90<br />

3 F0 F90 I180 I90<br />

4 H0 F90 I180 I90<br />

5 H0 G90 I180 I90<br />

6 H0 G90 J180 I90<br />

7 H0 H90 J180 I90<br />

8 H0 H90 I180 I90<br />

A.4.1 Bepaling <strong>van</strong> <strong>de</strong> cpe,10-coëfficiënten<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> -45°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -0,6 H90 -1,0 I180 -0,7 I90 -0,9<br />

2 F0 -0,6 H90 -1,0 I180 -0,7 I90 -0,9<br />

3 F0 -0,6 F90 -1,4 I180 -0,7 I90 -0,9<br />

4 H0 -0,8 F90 -1,4 I180 -0,7 I90 -0,9<br />

5 H0 -0,8 G90 -1,2 I180 -0,7 I90 -0,9<br />

6 H0 -0,8 G90 -1,2 J180 -1,0 I90 -0,9<br />

7 H0 -0,8 H90 -1,0 J180 -1,0 I90 -0,9<br />

8 H0 -0,8 H90 -1,0 I180 -0,7 I90 -0,9<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> -30°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -0,8 H90 -1,0 I180 -0,6 I90 -0,9<br />

2 F0 -1,1 H90 -1,0 I180 -0,6 I90 -0,9<br />

3 F0 -1,1 F90 -1,5 I180 -0,6 I90 -0,9<br />

4 H0 -0,8 F90 -1,5 I180 -0,6 I90 -0,9<br />

5 H0 -0,8 G90 -1,2 I180 -0,6 I90 -0,9<br />

6 H0 -0,8 G90 -1,2 J180 -0,8 I90 -0,9<br />

7 H0 -0,8 H90 -1,0 J180 -0,8 I90 -0,9<br />

8 H0 -0,8 H90 -1,0 I180 -0,6 I90 -0,9<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

126


Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> -15°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -1,3 H90 -0,8 I180 -0,5 I90 -0,8<br />

2 F0 -2,5 H90 -0,8 I180 -0,5 I90 -0,8<br />

3 F0 -2,5 F90 -1,9 I180 -0,5 I90 -0,8<br />

4 H0 -0,9 F90 -1,9 I180 -0,5 I90 -0,8<br />

5 H0 -0,9 G90 -1,2 I180 -0,5 I90 -0,8<br />

6 H0 -0,9 G90 -1,2 J180 -0,7 I90 -0,8<br />

7 H0 -0,9 H90 -0,8 J180 -0,7 I90 -0,8<br />

8 H0 -0,9 H90 -0,8 I180 -0,5 I90 -0,8<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> -5°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -1,2 H90 -0,7 I180 -0,6 +0,2 I90 -0,6<br />

2 F0 -2,3 H90 -0,7 I180 -0,6 +0,2 I90 -0,6<br />

3 F0 -2,3 F90 -1,8 I180 -0,6 +0,2 I90 -0,6<br />

4 H0 -0,8 F90 -1,8 I180 -0,6 +0,2 I90 -0,6<br />

5 H0 -0,8 G90 -1,2 I180 -0,6 +0,2 I90 -0,6<br />

6 H0 -0,8 G90 -1,2 J180 -0,6 +0,2 I90 -0,6<br />

7 H0 -0,8 H90 -0,7 J180 -0,6 +0,2 I90 -0,6<br />

8 H0 -0,8 H90 -0,7 I180 -0,6 +0,2 I90 -0,6<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> +5°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -1,2 +0,0 H90 -0,7 I180 -0,6 +0,2 I90 -0,6<br />

2 F0 -1,7 +0,0 H90 -0,7 I180 -0,6 +0,2 I90 -0,6<br />

3 F0 -1,7 +0,0 F90 -1,6 I180 -0,6 +0,2 I90 -0,6<br />

4 H0 -0,6 +0,0 F90 -1,6 I180 -0,6 +0,2 I90 -0,6<br />

5 H0 -0,6 +0,0 G90 -1,3 I180 -0,6 +0,2 I90 -0,6<br />

6 H0 -0,6 +0,0 G90 -1,3 J180 -0,6 +0,2 I90 -0,6<br />

7 H0 -0,6 +0,0 H90 -0,7 J180 -0,6 +0,2 I90 -0,6<br />

8 H0 -0,6 +0,0 H90 -0,7 I180 -0,6 +0,2 I90 -0,6<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> +15°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -0,8 +0,2 H90 -0,6 I180 -0,4 +0,0 I90 -0,5<br />

2 F0 -0,9 +0,2 H90 -0,6 I180 -0,4 +0,0 I90 -0,5<br />

3 F0 -0,9 +0,2 F90 -1,3 I180 -0,4 +0,0 I90 -0,5<br />

4 H0 -0,3 +0,2 F90 -1,3 I180 -0,4 +0,0 I90 -0,5<br />

5 H0 -0,3 +0,2 G90 -1,3 I180 -0,4 +0,0 I90 -0,5<br />

6 H0 -0,3 +0,2 G90 -1,3 J180 -1,0 +0,0 I90 -0,5<br />

7 H0 -0,3 +0,2 H90 -0,6 J180 -1,0 +0,0 I90 -0,5<br />

8 H0 -0,3 +0,2 H90 -0,6 I180 -0,4 +0,0 I90 -0,5<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

127


Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> +30°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -0,5 +0,7 H90 -0,8 I180 -0,4 +0,0 I90 -0,5<br />

2 F0 -0,5 +0,7 H90 -0,8 I180 -0,4 +0,0 I90 -0,5<br />

3 F0 -0,5 +0,7 F90 -1,1 I180 -0,4 +0,0 I90 -0,5<br />

4 H0 -0,2 +0,4 F90 -1,1 I180 -0,4 +0,0 I90 -0,5<br />

5 H0 -0,2 +0,4 G90 -1,4 I180 -0,4 +0,0 I90 -0,5<br />

6 H0 -0,2 +0,4 G90 -1,4 J180 -0,5 +0,0 I90 -0,5<br />

7 H0 -0,2 +0,4 H90 -0,8 J180 -0,5 +0,0 I90 -0,5<br />

8 H0 -0,2 +0,4 H90 -0,8 I180 -0,4 +0,0 I90 -0,5<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> +45°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -0,0 +0,7 H90 -0,9 I180 -0,2 +0,0 I90 -0,5<br />

2 F0 -0,0 +0,7 H90 -0,9 I180 -0,2 +0,0 I90 -0,5<br />

3 F0 -0,0 +0,7 F90 -1,1 I180 -0,2 +0,0 I90 -0,5<br />

4 H0 -0,0 +0,6 F90 -1,1 I180 -0,2 +0,0 I90 -0,5<br />

5 H0 -0,0 +0,6 G90 -1,4 I180 -0,2 +0,0 I90 -0,5<br />

6 H0 -0,0 +0,6 G90 -1,4 J180 -0,3 +0,0 I90 -0,5<br />

7 H0 -0,0 +0,6 H90 -0,9 J180 -0,3 +0,0 I90 -0,5<br />

8 H0 -0,0 +0,6 H90 -0,9 I180 -0,2 +0,0 I90 -0,5<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> +60°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 +0,7 H90 -0,8 I180 -0,2 I90 -0,5<br />

2 F0 +0,7 H90 -0,8 I180 -0,2 I90 -0,5<br />

3 F0 +0,7 F90 -1,1 I180 -0,2 I90 -0,5<br />

4 H0 +0,7 F90 -1,1 I180 -0,2 I90 -0,5<br />

5 H0 +0,7 G90 -1,2 I180 -0,2 I90 -0,5<br />

6 H0 +0,7 G90 -1,2 J180 -0,3 I90 -0,5<br />

7 H0 +0,7 H90 -0,8 J180 -0,3 I90 -0,5<br />

8 H0 +0,7 H90 -0,8 I180 -0,2 I90 -0,5<br />

Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> +75°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 +0,8 H90 -0,8 I180 -0,2 I90 -0,5<br />

2 F0 +0,8 H90 -0,8 I180 -0,2 I90 -0,5<br />

3 F0 +0,8 F90 -1,1 I180 -0,2 I90 -0,5<br />

4 H0 +0,8 F90 -1,1 I180 -0,2 I90 -0,5<br />

5 H0 +0,8 G90 -1,2 I180 -0,2 I90 -0,5<br />

6 H0 +0,8 G90 -1,2 J180 -0,3 I90 -0,5<br />

7 H0 +0,8 H90 -0,8 J180 -0,3 I90 -0,5<br />

8 H0 +0,8 H90 -0,8 I180 -0,2 I90 -0,5<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

128


A.4.2 Bepaling <strong>van</strong> <strong>de</strong> cpe,1-coëfficiënten<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> -45°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -0,6 H90 -1,3 I180 -0,7 I90 -1,2<br />

2 F0 -0,6 H90 -1,3 I180 -0,7 I90 -1,2<br />

3 F0 -0,6 F90 -2,0 I180 -0,7 I90 -1,2<br />

4 H0 -0,8 F90 -2,0 I180 -0,7 I90 -1,2<br />

5 H0 -0,8 G90 -2,0 I180 -0,7 I90 -1,2<br />

6 H0 -0,8 G90 -2,0 J180 -1,5 I90 -1,2<br />

7 H0 -0,8 H90 -1,3 J180 -1,5 I90 -1,2<br />

8 H0 -0,8 H90 -1,3 I180 -0,7 I90 -1,2<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> -30°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -1,5 H90 -1,3 I180 -0,6 I90 -1,2<br />

2 F0 -2,0 H90 -1,3 I180 -0,6 I90 -1,2<br />

3 F0 -2,0 F90 -2,1 I180 -0,6 I90 -1,2<br />

4 H0 -0,8 F90 -2,1 I180 -0,6 I90 -1,2<br />

5 H0 -0,8 G90 -2,0 I180 -0,6 I90 -1,2<br />

6 H0 -0,8 G90 -2,0 J180 -1,4 I90 -1,2<br />

7 H0 -0,8 H90 -1,3 J180 -1,4 I90 -1,2<br />

8 H0 -0,8 H90 -1,3 I180 -0,6 I90 -1,2<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> -15°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -2,0 H90 -1,2 I180 -0,5 I90 -1,2<br />

2 F0 -2,8 H90 -1,2 I180 -0,5 I90 -1,2<br />

3 F0 -2,8 F90 -2,5 I180 -0,5 I90 -1,2<br />

4 H0 -1,2 F90 -2,5 I180 -0,5 I90 -1,2<br />

5 H0 -1,2 G90 -2,0 I180 -0,5 I90 -1,2<br />

6 H0 -1,2 G90 -2,0 J180 -1,2 I90 -1,2<br />

7 H0 -1,2 H90 -1,2 J180 -1,2 I90 -1,2<br />

8 H0 -1,2 H90 -1,2 I180 -0,5 I90 -1,2<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> -5°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -2,0 H90 -1,2 I180 -0,6 +0,2 I90 -1,2<br />

2 F0 -2,5 H90 -1,2 I180 -0,6 +0,2 I90 -1,2<br />

3 F0 -2,5 F90 -2,5 I180 -0,6 +0,2 I90 -1,2<br />

4 H0 -1,2 F90 -2,5 I180 -0,6 +0,2 I90 -1,2<br />

5 H0 -1,2 G90 -2,0 I180 -0,6 +0,2 I90 -1,2<br />

6 H0 -1,2 G90 -2,0 J180 -0,6 +0,2 I90 -1,2<br />

7 H0 -1,2 H90 -1,2 J180 -0,6 +0,2 I90 -1,2<br />

8 H0 -1,2 H90 -1,2 I180 -0,6 +0,2 I90 -1,2<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

129


Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> +5°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -2,0 +0,0 H90 -1,2 I180 -0,6 +0,2 I90 -0,6<br />

2 F0 -2,5 +0,0 H90 -1,2 I180 -0,6 +0,2 I90 -0,6<br />

3 F0 -2,5 +0,0 F90 -2,2 I180 -0,6 +0,2 I90 -0,6<br />

4 H0 -1,2 +0,0 F90 -2,2 I180 -0,6 +0,2 I90 -0,6<br />

5 H0 -1,2 +0,0 G90 -2,0 I180 -0,6 +0,2 I90 -0,6<br />

6 H0 -1,2 +0,0 G90 -2,0 J180 -0,6 +0,2 I90 -0,6<br />

7 H0 -1,2 +0,0 H90 -1,2 J180 -0,6 +0,2 I90 -0,6<br />

8 H0 -1,2 +0,0 H90 -1,2 I180 -0,6 +0,2 I90 -0,6<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> +15°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -1,5 +0,2 H90 -1,2 I180 -0,4 +0,0 I90 -0,5<br />

2 F0 -2,0 +0,2 H90 -1,2 I180 -0,4 +0,0 I90 -0,5<br />

3 F0 -2,0 +0,2 F90 -2,0 I180 -0,4 +0,0 I90 -0,5<br />

4 H0 -0,3 +0,2 F90 -2,0 I180 -0,4 +0,0 I90 -0,5<br />

5 H0 -0,3 +0,2 G90 -2,0 I180 -0,4 +0,0 I90 -0,5<br />

6 H0 -0,3 +0,2 G90 -2,0 J180 -1,5 +0,0 I90 -0,5<br />

7 H0 -0,3 +0,2 H90 -1,2 J180 -1,5 +0,0 I90 -0,5<br />

8 H0 -0,3 +0,2 H90 -1,2 I180 -0,4 +0,0 I90 -0,5<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> +30°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -1,5 0,7 H90 -1,2 I180 -0,4 +0,0 I90 -0,5<br />

2 F0 -1,5 0,7 H90 -1,2 I180 -0,4 +0,0 I90 -0,5<br />

3 F0 -1,5 0,7 F90 -1,5 I180 -0,4 +0,0 I90 -0,5<br />

4 H0 -0,2 0,4 F90 -1,5 I180 -0,4 +0,0 I90 -0,5<br />

5 H0 -0,2 0,4 G90 -2,0 I180 -0,4 +0,0 I90 -0,5<br />

6 H0 -0,2 0,4 G90 -2,0 J180 -0,5 +0,0 I90 -0,5<br />

7 H0 -0,2 0,4 H90 -1,2 J180 -0,5 +0,0 I90 -0,5<br />

8 H0 -0,2 0,4 H90 -1,2 I180 -0,4 +0,0 I90 -0,5<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> +45°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 -0,0 +0,7 H90 -1,2 I180 -0,2 +0,0 I90 -0,5<br />

2 F0 -0,0 +0,7 H90 -1,2 I180 -0,2 +0,0 I90 -0,5<br />

3 F0 -0,0 +0,7 F90 -1,5 I180 -0,2 +0,0 I90 -0,5<br />

4 H0 -0,0 +0,6 F90 -1,5 I180 -0,2 +0,0 I90 -0,5<br />

5 H0 -0,0 +0,6 G90 -2,0 I180 -0,2 +0,0 I90 -0,5<br />

6 H0 -0,0 +0,6 G90 -2,0 J180 -0,3 +0,0 I90 -0,5<br />

7 H0 -0,0 +0,6 H90 -1,2 J180 -0,3 +0,0 I90 -0,5<br />

8 H0 -0,0 +0,6 H90 -1,2 I180 -0,2 +0,0 I90 -0,5<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

130


Zone<br />

Wind θ = 0°<br />

cpe,10 – Helling <strong>van</strong> +60°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 +0,7 H90 -1,0 I180 -0,2 I90 -0,5<br />

2 F0 +0,7 H90 -1,0 I180 -0,2 I90 -0,5<br />

3 F0 +0,7 F90 -1,5 I180 -0,2 I90 -0,5<br />

4 H0 +0,7 F90 -1,5 I180 -0,2 I90 -0,5<br />

5 H0 +0,7 G90 -2,0 I180 -0,2 I90 -0,5<br />

6 H0 +0,7 G90 -2,0 J180 -0,3 I90 -0,5<br />

7 H0 +0,7 H90 -1,0 J180 -0,3 I90 -0,5<br />

8 H0 +0,7 H90 -1,0 I180 -0,2 I90 -0,5<br />

Zone<br />

Wind θ = 0°<br />

cpe,1 – Helling <strong>van</strong> +75°<br />

Wind θ = 90° Wind θ = 180° Wind θ = 90°(+)<br />

1 G0 +0,8 H90 -1,0 I180 -0,2 I90 -0,5<br />

2 F0 +0,8 H90 -1,0 I180 -0,2 I90 -0,5<br />

3 F0 +0,8 F90 -1,5 I180 -0,2 I90 -0,5<br />

4 H0 +0,8 F90 -1,5 I180 -0,2 I90 -0,5<br />

5 H0 +0,8 G90 -2,0 I180 -0,2 I90 -0,5<br />

6 H0 +0,8 G90 -2,0 J180 -0,3 I90 -0,5<br />

7 H0 +0,8 H90 -1,0 J180 -0,3 I90 -0,5<br />

8 H0 +0,8 H90 -1,0 I180 -0,2 I90 -0,5<br />

De diagrammen uit afbeelding 32 wer<strong>de</strong>n <strong>op</strong>gesteld door voor eenzelf<strong>de</strong> zone <strong>de</strong> cpe,10- en cpe,1waar<strong>de</strong>n<br />

te nemen <strong>van</strong> <strong>de</strong> verschillen<strong>de</strong> dakhellingen.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

131


BIJLAGE 5<br />

BEREKENING VAN DE GEMIDDELDE ELASTICITEITSMODULUS Em<br />

VOOR DE DIMENSIONERING VAN HOUTEN SCHRIJNWERK<br />

Wanneer een dragend element uit massief hout blootgesteld wordt aan blijven<strong>de</strong> belastingen Ap<br />

(eigengewicht, gewicht <strong>van</strong> <strong>de</strong> vulelementen, …) en aan kortetermijnbelastingen At (wind,<br />

sneeuw), is <strong>het</strong> mogelijk een gemid<strong>de</strong>l<strong>de</strong> elasticiteitsmodulus Em te berekenen die toelaat <strong>de</strong><br />

totale vervorming µfin in één enkele stap te bepalen.<br />

Deze bijlage is <strong>van</strong> toepassing <strong>op</strong> voorwaar<strong>de</strong> dat <strong>de</strong> blijven<strong>de</strong> belastingen Ap en <strong>de</strong><br />

kortetermijnbelastingen At <strong>het</strong>zelf<strong>de</strong> belastingsschema vertonen (bv. gelijkmatig ver<strong>de</strong>el<strong>de</strong><br />

belastingen over <strong>de</strong> volledige lengte <strong>van</strong> <strong>het</strong> element, trapezoïdale belastingen,<br />

puntbelastingen, …) en in <strong>het</strong>zelf<strong>de</strong> vlak liggen.<br />

L<br />

A p<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

A t<br />

L<br />

Afbeelding A5.1 Voorbeel<strong>de</strong>n <strong>van</strong> belastingsschema’s.<br />

Volgens <strong>de</strong> principes <strong>van</strong> <strong>de</strong> norm NBN EN 1995-1-1 (§ 2.2.3), is <strong>de</strong> totale vervorming gelijk<br />

aan <strong>de</strong> som <strong>van</strong> <strong>de</strong> vervormingen <strong>van</strong> <strong>de</strong> blijven<strong>de</strong> belastingen en <strong>de</strong> kortetermijnbelastingen :<br />

µfin = µAt + µAp<br />

Als men <strong>de</strong> gelijkmatig ver<strong>de</strong>el<strong>de</strong> belastingen in aanmerking neemt, krijgt men :<br />

5×<br />

( A + A )<br />

t<br />

384 × E<br />

m<br />

p<br />

× L<br />

× I<br />

4<br />

5×<br />

At<br />

× L<br />

=<br />

E<br />

384 ×<br />

0<br />

( 1+<br />

ψ × k )<br />

2<br />

4<br />

<strong>de</strong>f<br />

4<br />

5×<br />

Ap<br />

× L<br />

+<br />

E0<br />

× I 384 × × I<br />

1+<br />

k<br />

4<br />

5×<br />

L<br />

Indien men <strong>de</strong> vergelijking vereenvoudigt door en indien <strong>de</strong> waar<strong>de</strong> ψ2 = 0 (NBN EN<br />

384 × I<br />

1990-ANB, § A1.2.2) en k<strong>de</strong>f = 0,8 (NBN EN 1995-1-1, § 2.3.1.2, tabel 3.2), krijgt men :<br />

en<br />

Opmerking : <strong>de</strong> vereenvoudiging door<br />

belastingsschema.<br />

E<br />

At + Ap<br />

A A t p<br />

= +<br />

E E E<br />

m<br />

0 0<br />

1,<br />

8<br />

m<br />

= E<br />

0<br />

4<br />

5×<br />

L<br />

384 × I<br />

( A + 1,<br />

8×<br />

A )<br />

t<br />

A + A<br />

t<br />

p<br />

p<br />

maakt <strong>de</strong> formule <strong>van</strong> Em onafhankelijk <strong>van</strong> <strong>het</strong><br />

<strong>de</strong>f<br />

132


Voorbeeld<br />

We beschouwen :<br />

− een gelijkmatig ver<strong>de</strong>el<strong>de</strong> blijven<strong>de</strong> belasting Ap (eigengewicht) = 1200 N/m = 1,200 N/mm<br />

− een gelijkmatig ver<strong>de</strong>el<strong>de</strong> kortetermijnbelasting At = 800 N/m = 0,8 N/mm<br />

− een balk met sectie 8/23 en een lengte tussen <strong>de</strong> steunpunten L = 5000 mm<br />

E0 = 11 000 MPa<br />

3<br />

75×<br />

225<br />

4<br />

I 8x<br />

23 = = 71191406,<br />

62mm<br />

12<br />

1,<br />

2 + 0,<br />

8<br />

Em<br />

= 110000 ×<br />

= 7432N<br />

/ mm²<br />

0,<br />

8 + 1,<br />

8×<br />

1,<br />

2<br />

μ<br />

μ<br />

fin<br />

fin<br />

( A + A )<br />

5×<br />

t<br />

=<br />

384×<br />

E<br />

m<br />

p<br />

× L<br />

× I<br />

( 1,<br />

2 + 0,<br />

8)<br />

4<br />

5×<br />

× 5000<br />

=<br />

384 × 71191406 × 7432<br />

=<br />

30,<br />

76<br />

mm<br />

4<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

133


BIJLAGE 6<br />

ILLUSTRATIEF VOORBEELD VAN HET GUNSTIGE OF ONGUNSTIGE<br />

EFFECT VAN DE BELASTING OP DE BEREKENING VAN EEN<br />

SECUNDAIRE CONSTRUCTIE<br />

A6.1 Ontwerpsituatie<br />

We beschouwen <strong>het</strong> volgen<strong>de</strong> glazen dak :<br />

• gebouw met een normale wandin<strong>de</strong>ling<br />

• afmetingen <strong>van</strong> <strong>het</strong> glazen dak : breedte = 4,5 m, overspanning L = 4 m<br />

• hoogte <strong>van</strong> <strong>het</strong> bouwwerk <strong>van</strong>af <strong>de</strong> grond : 8 m<br />

• ligging <strong>van</strong> <strong>het</strong> terrein :<br />

lage vegetatie met geïsoleer<strong>de</strong> obstakels<br />

hoogte : 200 m<br />

• hart-<strong>op</strong>-hartafstand <strong>van</strong> <strong>de</strong> draagbalken : 0,7 m, houtkwaliteit C24 volgens NBN EN 338<br />

• helling α = 5°<br />

• glazen vulelement met een totale dikte <strong>van</strong> 10 mm<br />

• <strong>het</strong> glazen dak ligt in <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> een dak met één enkel dakschild.<br />

A6.2 Analyse <strong>van</strong> <strong>het</strong> <strong>ontwerp</strong> : type secundaire constructie<br />

• Totale <strong>op</strong>pervlakte : 4,2 m x 4 m = 16,8 m²<br />

• Overspanning : 4 m<br />

Dit schrijnwerkgeheel is dus een glazen dak (zie § 3.1 en § 3.4).<br />

A6.3 Belastingen <strong>op</strong> <strong>de</strong> secundaire constructie<br />

A6.3.1 Eigengewicht<br />

4,20<br />

• Lineair gewicht <strong>van</strong> <strong>het</strong> profiel = 100 N/m<br />

• Gewicht <strong>van</strong> <strong>het</strong> glas 33.2-12-4 = 10 x 25 x 0,7 = 175 N/m<br />

Totaal <strong>op</strong> <strong>de</strong> keper : gk = 275 N/m<br />

• gk┴ = 275 *cos (5°) = 273,9 N (zie § 4.5)<br />

• gk// = 275 *sin (5°) = 24 N<br />

Men dient dus niet over te gaan tot <strong>de</strong> ontbinding <strong>van</strong> <strong>de</strong> belastingen.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

4,00<br />

α =5°<br />

0,70<br />

134


A6.3.2 Wind<br />

We beschouwen : w = ce(z)qref 50jaar . cprob² . cp<br />

cp = cpe - cpi<br />

• ce(z) qref 50 jaar = 994 Pa (vb0 = 26 m/s - ruwheidsklasse 2)<br />

• belastings<strong>op</strong>pervlak : A = 0,7 x 4 = 2,8 m² (zie § 4.1.2.5.2)<br />

• cpi = +0,2 (overdruk binnen)<br />

-0,3 (on<strong>de</strong>rdruk binnen)<br />

(zie § 4.1.2.5.3.1)<br />

• cpe-coëfficiënt <strong>op</strong> één enkel dakschild (zie afbeelding 28, zone 10) :<br />

o cpe,10 = -0,80 (on<strong>de</strong>rdruk buiten)<br />

o cpe,1 = -1,20<br />

cpe,A = cpe,1 - (cpe,1 -cpe,10) log10 A (afbeelding 19)<br />

cpe 2,8 = -1,20 – (-1,20 + 0,80) log10 2,8<br />

cpe 2,8 = -1,02<br />

Totaal : w = 994 * (-1,02 - 0,2) = -1212 N/m²<br />

w = 994 * (-1,02 + 0,3) = -716N/m²<br />

Totaal <strong>op</strong> <strong>de</strong> keper : w = -0,7 * 1212 = -849 N/m<br />

Totaal <strong>op</strong> <strong>de</strong> keper : w = - 0,7 * 716 = -501 N/m<br />

• cpe,10 = cpe,1 = +0,2 in overdruk <strong>op</strong> één enkel dakschild (zie afbeelding 28, zone 10)<br />

Totaal : w = 994 * (0,2 –(-0,3)) = 497 N/m²<br />

Totaal <strong>op</strong> <strong>de</strong> keper : w = 0,7 * 497 = 348 N/m<br />

A6.3.3 Sneeuw<br />

• sk = 0,5 + 0,007(A-100)/6 = 0,616 kN/m² (zie tabel 13)<br />

• μi = 0,8 (zie tabel 14)<br />

Totaal : sk = 0,493 kN/m² = 493 N/m²<br />

Totaal <strong>op</strong> <strong>de</strong> keper : sk = 0,7 * 493 = 345 N/m<br />

A6.4 Belastingscombinaties<br />

A6.4.1 Gebruiksgrenstoestand<br />

Eigengewicht + wind (zie tabel 26)<br />

Belastingen : Fd(g,w) = gk + 0,9 ce(z)qref 50jaar cp<br />

− Wind in on<strong>de</strong>rdruk = 275+ 0,9*(- 849) = -489 N/m<br />

− Wind in overdruk = 275+ 0,9*(348) = 588 N/m<br />

Rekening hou<strong>de</strong>nd met voetnoot ( 3 ) <strong>van</strong> tabel 26 (zie ook § 4.6.1) : Fd (g,w) = gk + 0 = 275 N/m<br />

Materiaal (zie § 5, nota 2.2 en bijlage 5)<br />

Hout – Combinatie <strong>van</strong> blijven<strong>de</strong> en veran<strong>de</strong>rlijke belastingen :<br />

w + gk<br />

275 + ( 0,<br />

9×<br />

849)<br />

− Wind in on<strong>de</strong>rdruk : Em<br />

= E0<br />

= 11000<br />

= 9076MPa<br />

( wt<br />

+ 1,<br />

8×<br />

g k ) ( 849×<br />

0,<br />

9)<br />

+ 1,<br />

8×<br />

275<br />

w + gk<br />

275 + ( 0,<br />

9×<br />

348)<br />

− Wind in overdruk : Em<br />

= E0<br />

= 11000<br />

= 8005MPa<br />

( wt<br />

+ 1,<br />

8×<br />

g k ) ( 348×<br />

0,<br />

9)<br />

+ 1,<br />

8×<br />

275<br />

E0<br />

11000<br />

Hout – Blijven<strong>de</strong> belasting : E fin =<br />

= = 6111MPa<br />

1+<br />

k 1,<br />

8<br />

( )<br />

<strong>de</strong>f<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

135


Berekening <strong>van</strong> <strong>de</strong> vervorming en controle <strong>van</strong> <strong>het</strong> criterium<br />

De keper wordt on<strong>de</strong>rworpen aan een gelijkmatig ver<strong>de</strong>el<strong>de</strong> belasting over <strong>de</strong> volledige lengte.<br />

Tabel 26 geeft <strong>de</strong> maximale vervormingscriteria <strong>op</strong>. We willen eraan herinneren dat y//, gezien<br />

<strong>de</strong> zwakke helling, niet gecontroleerd wordt. Het toe te passen criterium is dus :<br />

y┴ ≤ 4+ L/330<br />

4 + 4000/330 = 16,12 mm.<br />

Controle on<strong>de</strong>r <strong>de</strong> windbelasting (overdruk) en <strong>het</strong> eigengewicht : <strong>de</strong> vereiste inertie bedraagt<br />

4<br />

4<br />

5×<br />

( w + g k ) × L 5×<br />

( 588 / 1000)<br />

× 4000<br />

I =<br />

=<br />

= 15.188.116 mm<br />

384×<br />

Em<br />

× y⊥<br />

384 × 8005×<br />

16,<br />

12<br />

4 ,<br />

wat overeenstemt met een sectie <strong>van</strong> 7 x 15 = 70*150³/12 = 19.687.500 mm 4 .<br />

De controle on<strong>de</strong>r <strong>de</strong> combinatie veroorzaakt door <strong>het</strong> eigengewicht en <strong>de</strong> wind in on<strong>de</strong>rdruk is<br />

niet nodig.<br />

Controle on<strong>de</strong>r <strong>het</strong> eigengewicht :<br />

4<br />

4<br />

5×<br />

( g k ) × L 5×<br />

( 275 / 1000)<br />

× 4000<br />

I =<br />

=<br />

= 9.305.380 mm<br />

384 × E fin × y⊥<br />

384×<br />

6111×<br />

16,<br />

12<br />

4 ,<br />

wat overeenstemt met een sectie <strong>van</strong> 7 x 15.<br />

Eigengewicht + sneeuw (zie tabel 28)<br />

Belastingen : Fd(g,s) = gk + μi sk = 275 + 345 = 620 N/m<br />

Rekening hou<strong>de</strong>nd met voetnoot ( 5 ) <strong>van</strong> tabel 28 (zie ook § 4.6.1) : Fd(g,s) = gk + 0 = 275 N/m<br />

(reeds in aanmerking genomen hierboven)<br />

Materiaal (zie § 5, nota’s 2.2, 2.3 en bijlage 5)<br />

Hout – Combinatie <strong>van</strong> blijven<strong>de</strong> en kortetermijnbelastingen :<br />

µ i × sk<br />

+ g k<br />

620<br />

Em<br />

= E0<br />

= 11000<br />

= 8119MPa<br />

( ( µ i × sk<br />

) + 1,<br />

8×<br />

gk<br />

) 345 + 1,<br />

8×<br />

275<br />

Berekening <strong>van</strong> <strong>de</strong> vervorming en controle <strong>van</strong> <strong>het</strong> criterium<br />

De keper wordt on<strong>de</strong>rworpen aan een gelijkmatig ver<strong>de</strong>el<strong>de</strong> belasting over <strong>de</strong> volledige lengte.<br />

Tabel 28 geeft <strong>de</strong> maximale vervormingscriteria <strong>op</strong>. We willen er<strong>op</strong> wijzen dat y//, gezien <strong>de</strong><br />

zwakke helling, niet gecontroleerd wordt. Het toe te passen criterium is dus :<br />

y┴ ≤ 4 + L/330<br />

4 + 4000/330 = 16,12 mm.<br />

Controle on<strong>de</strong>r <strong>de</strong> sneeuwbelasting en <strong>het</strong> eigengewicht : <strong>de</strong> vereiste inertie I bedraagt<br />

4<br />

4<br />

5×<br />

( µ i × sk<br />

+ g k ) × L 5×<br />

( 620 / 1000)<br />

× 4000<br />

I =<br />

=<br />

= 15.790.753 mm<br />

384×<br />

Em<br />

× y⊥<br />

384 × 8119 × 16,<br />

12<br />

4 ,<br />

wat overeenstemt met een sectie <strong>van</strong> 7 x 15 = 19.687.500 mm 4 .<br />

Besluit voor <strong>de</strong> gebruiksgrenstoestand : sectie <strong>van</strong> 7 x 15 = 19.687.500 mm 4 .<br />

A6.4.2 Uiterste grenstoestand<br />

Men dient na te gaan of <strong>de</strong> sectie, bepaald voor <strong>de</strong> gebruiksgrenstoestand, voldoet aan <strong>de</strong> criteria<br />

voor <strong>de</strong> uiterste grenstoestand.<br />

Berekening <strong>van</strong> <strong>de</strong> belasting en controle <strong>van</strong> <strong>het</strong> criterium<br />

De keper wordt on<strong>de</strong>rworpen aan een gelijkmatig ver<strong>de</strong>el<strong>de</strong> belasting over <strong>de</strong> volledige lengte.<br />

Tabel 26 geeft <strong>de</strong> criteria voor <strong>de</strong> uiterste grenstoestand <strong>op</strong>. We willen er<strong>op</strong> wijzen dat σ//, gezien<br />

<strong>de</strong> zwakke helling, niet gecontroleerd wordt. Het toe te passen criterium is dus : Ed ≤ Xk /γM.<br />

In ons geval dienen we <strong>de</strong> buigbelasting te controleren : Ed(g,w) = σ(g,w).<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

136


Controle on<strong>de</strong>r <strong>de</strong> windbelasting en <strong>het</strong> eigengewicht : <strong>de</strong> vergelijking voor <strong>de</strong> buigbelasting is :<br />

2 ⎛ Fd<br />

× L ⎞ h<br />

M v<br />

⎜<br />

⎟ × ( )<br />

2<br />

× ⎝ 8 ⎠ 2 Fd<br />

× L × h<br />

σ = =<br />

= , waarbij<br />

I<br />

I<br />

16×<br />

I<br />

M = <strong>het</strong> buigmoment (N.mm)<br />

v = <strong>de</strong> afstand <strong>van</strong> <strong>de</strong> neutrale as tot <strong>het</strong> uitein<strong>de</strong> <strong>van</strong> <strong>de</strong> sectie = helft <strong>van</strong> <strong>de</strong> keperhoogte = h/2<br />

h = <strong>de</strong> hoogte <strong>van</strong> <strong>de</strong> keper<br />

L = <strong>de</strong> lengte <strong>van</strong> <strong>de</strong> keper (mm)<br />

I = <strong>de</strong> inertie <strong>van</strong> <strong>de</strong> sectie (mm 4 )<br />

σ = <strong>de</strong> buigspanning<br />

Fd = <strong>de</strong> resultante <strong>van</strong> <strong>de</strong> belastingscombinatie (N/mm).<br />

Materiaal (zie § 5, nota’s 2.2 en 2.3)<br />

Hout – Combinatie <strong>van</strong> blijven<strong>de</strong> en veran<strong>de</strong>rlijke belastingen :<br />

X k 24<br />

X d = kmod<br />

× = 0,<br />

9×<br />

= 16,<br />

6MPa<br />

( γ M ) 1,<br />

3<br />

X k 24<br />

Hout – Blijven<strong>de</strong> belasting : X d = kmod<br />

× = 0,<br />

6 × = 11MPa<br />

1,<br />

3<br />

( γ )<br />

Eigengewicht + wind (zie tabel 26)<br />

Fd,1(g,w) = 1,15 gk + 1,25 ce(z)qref 50jaar cp = 1,15*275 +1,25*(+348) = 751,25 N/m<br />

Fd,2(g,w) = 1,00 gk + 1,25 ce(z)qref 50jaar cp = = 1,00*275 +1,25*(- 849) = -786,25 N/m<br />

2<br />

2<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

M<br />

Fd × L × h 0,<br />

786×<br />

4000 × 150<br />

σ = =<br />

= 5,<br />

98MPa<br />

≤ 16,6 MPa.<br />

16×<br />

I 16×<br />

19687500<br />

Rekening hou<strong>de</strong>nd met voetnoot ( 3 ) <strong>van</strong> tabel 26 (zie § 4.6.1) : Fd(g,w) = 1,15 gk + 0 = 316 N/m<br />

2<br />

2<br />

Fd × L × h 0,<br />

316×<br />

4000 × 150<br />

σ = =<br />

= 2,<br />

4MPa<br />

≤ 11 MPa.<br />

16×<br />

I 16×<br />

19687500<br />

Eigengewicht + sneeuw (zie tabel 28)<br />

Belastingen : Fd(g,w) = 1,15 gk + 1,25 μi sk = 1,15 x 275 + 1,25 x 345 = 748 N/m<br />

Rekening hou<strong>de</strong>nd met voetnoot ( 5 ) <strong>van</strong> tabel 28 (zie § 4.6.1) : Fd(g,w) = 1,15 gk + 0 = 316 N/m<br />

(reeds in aanmerking genomen hierboven)<br />

2<br />

2<br />

Fd × L × h 0,<br />

748×<br />

4000 × 150<br />

σ = =<br />

= 5,<br />

7MPa<br />

≤ 16,6 MPa.<br />

16×<br />

I 16×<br />

19687500<br />

Eigengewicht + sneeuw + wind (zie tabel 31)<br />

Fd(C1) = 1,15. gk + 1,25. μi . sk + 0,37. ce(z)qref 50jaar cp<br />

1,15.275 + 1,25.345 + 0,37. 348 = 876 N/m (wind in overdruk)<br />

In toepassing <strong>van</strong> § 4.6.1 : 275 + 0 + 0,37. (-849) = -39,13 N/m (wind in on<strong>de</strong>rdruk)<br />

Fd(C2) = 1,15. gk + 1,25. ce(z)qref 50jaar cp + 0,37 μi .sk<br />

1,15.275 + 1,25.348 + 0,37. 345 = 879 N/m<br />

In toepassing <strong>van</strong> § 4.6.1 : 275 + 1,25. (-849) + 0 = -786,25 N/m (wind in on<strong>de</strong>rdruk) = Fd,2<br />

(cf. hierboven)<br />

σ =<br />

2<br />

2<br />

Fd × L × h 0,<br />

879×<br />

4000 × 150<br />

=<br />

= 6,<br />

69MPa<br />

16×<br />

I 16×<br />

19687500<br />

Besluit voor <strong>de</strong> uiterste grenstoestand : sectie <strong>van</strong> 7 x 15.<br />

137


BIJLAGE 7 BEREKENING VAN HET GLAS<br />

INHOUD<br />

A7-1. GLASBREUKMECHANISMEN ............................................................................................... 139<br />

A7-2. KARAKTERISTIEKEN VAN GLAS........................................................................................ 140<br />

A7-2.1.Algemene fysische eigenschappen .................................................................................. 140<br />

A7-2.2.Mechanische eigenschappen ........................................................................................... 140<br />

A7-2.2.1.Uitgegloeid glas (float).................................................................................... 140<br />

A7-2.2.2.Dubbele isoleren<strong>de</strong> beglazing.......................................................................... 141<br />

A7-2.2.2.1.Inwendige druk in <strong>de</strong> isoleren<strong>de</strong> beglazing......................................... 141<br />

A7-2.2.2.2.Krachtenver<strong>de</strong>ling over <strong>de</strong> lagen <strong>van</strong> een isoleren<strong>de</strong> beglazing ......... 143<br />

A7-2.2.2.2.1.Eerste bena<strong>de</strong>ring ................................................................. 143<br />

A7-2.2.2.2.2.Meer precieze berekening .................................................... 143<br />

A7-2.2.3.Driedubbele beglazing..................................................................................... 143<br />

A7-2.2.4.Gelaagd glas .................................................................................................... 144<br />

A7-3. REKENMODELLEN .................................................................................................................. 146<br />

A7-3.1.Algemeen .......................................................................................................................... 146<br />

A7-3.1.1.Gebruiksgrenstoestand : berekening <strong>van</strong> <strong>de</strong> vervorming ................................ 146<br />

A7-3.1.2.Uiterste grenstoestand : berekening <strong>van</strong> <strong>de</strong> spanning...................................... 146<br />

A7-3.1.3.Lineair mo<strong>de</strong>l................................................................................................... 146<br />

A7-3.1.4.Niet-lineair mo<strong>de</strong>l............................................................................................ 146<br />

A7-3.1.5.Symbolen en afkortingen................................................................................. 146<br />

A7-3.2.Gelijkmatig belaste rechthoekige plaat, gewoon <strong>op</strong>gelegd <strong>op</strong> twee ran<strong>de</strong>n................ 147<br />

A7-3.2.1.UGT – Berekening <strong>van</strong> <strong>de</strong> belasting................................................................ 147<br />

A7-3.2.2.GGT – Berekening <strong>van</strong> <strong>de</strong> vervorming ........................................................... 147<br />

A7-3.3.Gelijkmatig belaste rechthoekige plaat, gewoon <strong>op</strong>gelegd <strong>op</strong> vier ran<strong>de</strong>n................. 148<br />

A7-3.3.1.Studie <strong>van</strong> <strong>de</strong> belasting.................................................................................... 148<br />

A7-3.3.2.Studie <strong>van</strong> <strong>de</strong> vervorming................................................................................ 149<br />

A7-3.4.Controle <strong>van</strong> <strong>de</strong> eigenfrequentie <strong>van</strong> beglazingen ........................................................ 149<br />

A7-4. BELASTINGSCOMBINATIES EN CONTROLE VAN DE GRENS-<br />

TOESTANDEN.......................................................................................................................... 150<br />

A7-4.1.Verticale gevel .................................................................................................................. 150<br />

A7-4.2.Hellen<strong>de</strong> gevel of hellend dak ......................................................................................... 151<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

138


A7-1. Glasbreukmechanismen<br />

De teksten uit dit hoofdstuk vormen een bekn<strong>op</strong>te samenvatting <strong>van</strong> diverse<br />

wetenschappelijke artikels.<br />

Tij<strong>de</strong>ns zijn fabricage kan <strong>het</strong> glas aan <strong>het</strong> <strong>op</strong>pervlak een (min of meer groot) aantal gebreken<br />

en microscheurtjes vertonen, die onzichtbaar zijn voor <strong>het</strong> blote oog, omdat <strong>de</strong> afstand tussen<br />

<strong>de</strong> ran<strong>de</strong>n <strong>van</strong> <strong>de</strong> gebreken kleiner is dan <strong>de</strong> golflengte <strong>van</strong> <strong>het</strong> licht, waardoor er bijna geen<br />

zichtbare reflectie <strong>op</strong>treedt.<br />

Wanneer <strong>het</strong> glas echter belast wordt, wor<strong>de</strong>n <strong>de</strong>ze gebreken groter en versprei<strong>de</strong>n ze zich in<br />

<strong>het</strong> glas. De factoren die <strong>de</strong>ze verspreiding beïnvloe<strong>de</strong>n zijn :<br />

• <strong>de</strong> snelheid en <strong>de</strong> tijdsduur <strong>van</strong> <strong>de</strong> belasting : naarmate <strong>de</strong> belasting langer duurt, zal <strong>de</strong><br />

glassterkte lager zijn<br />

• <strong>de</strong> belastingsgraad ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong> breukgrens<br />

• <strong>de</strong> eventuele aanwezigheid <strong>van</strong> water (on<strong>de</strong>r al zijn verschijningsvormen)<br />

• <strong>de</strong> temperatuur<br />

• <strong>de</strong> samenstelling <strong>van</strong> <strong>het</strong> glas (niet bepalend in <strong>het</strong> geval <strong>van</strong> genomaliseerd glas).<br />

Als men <strong>de</strong> verspreidingssnelheid uitdrukt aan <strong>de</strong> hand <strong>van</strong> <strong>de</strong> hierboven vermel<strong>de</strong> factoren,<br />

kan men ruwweg drie snelhe<strong>de</strong>n on<strong>de</strong>rschei<strong>de</strong>n :<br />

• een nulsnelheid : dit wil zeggen dat <strong>het</strong> geheel <strong>de</strong>r factoren die inwerken <strong>op</strong> <strong>het</strong> <strong>op</strong>pervlak<br />

geen verslechtering ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong> oorspronkelijke toestand veroorzaakt<br />

• een lage snelheid : <strong>de</strong> gebreken versprei<strong>de</strong>n zich langzaam in <strong>het</strong> glas, maar maar doch <strong>op</strong><br />

zulke wijze dat ze verenigbaar blijven met een gebruik waarbij <strong>de</strong> mechanische sterkte<br />

nodig is om <strong>de</strong> gebruiksveiligheid te waarborgen<br />

• een hoge snelheid, die, afhankelijk <strong>van</strong> <strong>de</strong> combinatie <strong>van</strong> <strong>de</strong> factoren, leidt tot een snelle<br />

breuk.<br />

De breuk <strong>van</strong> uitgegloeid floatglas on<strong>de</strong>r spanning, tengevolge <strong>van</strong> <strong>de</strong> verspreiding <strong>van</strong> <strong>de</strong><br />

gebreken <strong>van</strong> <strong>het</strong> <strong>op</strong>pervlak, wordt aangeduid als statische vermoeiing. Dit leidt tot<br />

dimensioneringsmetho<strong>de</strong>n die afwijken <strong>van</strong> <strong>de</strong> courant gebruikte metho<strong>de</strong>n. Deze zijn<br />

gebaseerd <strong>op</strong> <strong>de</strong> studie <strong>van</strong> <strong>de</strong> afmetingen <strong>van</strong> <strong>de</strong> microscheurtjes (crack size <strong>de</strong>sign) rekening<br />

hou<strong>de</strong>nd met <strong>de</strong> glaskenmerken (oorspronkelijke afmeting <strong>van</strong> <strong>de</strong> microscheurtjes, …), met<br />

<strong>het</strong> bereken<strong>de</strong> element (plaat, balk, steunpunt, …) en met <strong>de</strong> belastingswijze. Ook <strong>de</strong> kwaliteit<br />

<strong>van</strong> <strong>de</strong> versnijding en <strong>de</strong> bewerking <strong>van</strong> <strong>het</strong> glas is hierbij <strong>van</strong> belang.<br />

Wat <strong>de</strong> dynamische vermoeiing betreft, blijkt uit bepaal<strong>de</strong> studies dat er, in vergelijking tot<br />

een statische belasting, voor een lage verspreidingssnelheid geen bijkomen<strong>de</strong> beschadiging<br />

<strong>op</strong>treedt als gevolg <strong>van</strong> <strong>het</strong> cyclische karakter <strong>van</strong> <strong>de</strong> belasting. In tegenstelling tot an<strong>de</strong>re<br />

materialen waarvoor een cyclische belasting wel <strong>de</strong>structiever is dan een statische, vertoont<br />

glas geen bedui<strong>de</strong>n<strong>de</strong> dynamsiche vermoeiing. Wanneer <strong>het</strong> glas niet langer belast wordt,<br />

recupereert <strong>het</strong> in zekere mate zijn initiële sterkte.<br />

Deze bijlage heeft enerzijds tot doel om een rekenmetho<strong>de</strong> voor <strong>de</strong> meest voorkomen<strong>de</strong><br />

glazen vulelementen voor te stellen, en an<strong>de</strong>rzijds om coëfficiënten voor <strong>de</strong> materialen te<br />

formuleren die – in combinatie met <strong>de</strong> coëfficiënten voor <strong>de</strong> belastingscombinaties – toelaten<br />

om een voldoen<strong>de</strong> betrouwbaarheid te waarborgen. De metho<strong>de</strong> beperkt zich tot belastingen<br />

en belastingscombinaites die gelijkmatig ver<strong>de</strong>eld zijn over vierkante of rechthoekige platen<br />

die gewoon <strong>op</strong>gelegd zijn <strong>op</strong> twee of vier ran<strong>de</strong>n.<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

139


A7-2. Karakteristieken <strong>van</strong> glas<br />

A7-2.1. Algemene fysische eigenschappen<br />

De algemeen erken<strong>de</strong> fysische glaseigenschappen zijn <strong>op</strong>genomen in <strong>de</strong> normen met<br />

betrekking tot <strong>de</strong> verschillen<strong>de</strong> glastypes : voor uitgegloeid glas (float) : NBN EN 572-1; voor<br />

halfgehard glas : NBN EN 1863-1; voor gehard glas : NBN EN 12150-1.<br />

Gewoonlijk wor<strong>de</strong>n <strong>de</strong> volgen<strong>de</strong> waar<strong>de</strong>n weerhou<strong>de</strong>n :<br />

- volumieke massa ρ = 2 500 kg/m³<br />

- elasticiteitsmodulus (Young-modulus) E = 70 000 MPa<br />

- Poisson-coëfficiënt ν = 0,20.<br />

A7-2.2. Mechanische eigenschappen<br />

A7-2.2.1. Uitgegloeid glas (float)<br />

De rekenwaar<strong>de</strong> voor <strong>de</strong> spanning in <strong>het</strong> glas wordt als volgt uitgedrukt :<br />

kmod<br />

× k sp × ffg,k<br />

g;<br />

k<br />

XXg,d<br />

g,<br />

d = , waarbij<br />

γ<br />

M ; A<br />

- fg,k : <strong>de</strong> karakteristieke buigsterkte, gelijk aan 45 N/mm 2<br />

γM,A<br />

- γM,A : <strong>de</strong> partiële coëfficiënt voor uitgegloeid glas, gelijk aan 1,80<br />

- ksp : <strong>de</strong> profielfactor <strong>van</strong> <strong>het</strong> <strong>op</strong>pervlak (cf. tabel A7-1)<br />

- kmod : <strong>de</strong> tijdsduurfactor <strong>van</strong> <strong>de</strong> belasting of <strong>de</strong> belastingscombinatie.<br />

Tabel A7-1 Oppervlaktefactor ksp.<br />

Glastype ksp<br />

Uitgegloeid floatglas 1,0<br />

Figuurglas 0,75<br />

Gawapend gepolijst glas 0,75<br />

Gewapend figuurglas 0,60<br />

De factor kmod drukt <strong>de</strong> vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> bereken<strong>de</strong> buigspanning uit, naargelang <strong>van</strong> <strong>de</strong><br />

tijdsduur <strong>van</strong> <strong>de</strong> belasting of <strong>de</strong> belastingscombinatie. Voor uitgegloeid glas bedraagt<br />

mod<br />

1<br />

−<br />

16<br />

k = 0,<br />

663×<br />

t waarbij 0,25 ≤ kmod ≤ 1 en waarbij «t» uitgedrukt wordt in uur.<br />

De «t»-waar<strong>de</strong> vertegenwoordigt <strong>de</strong> tijd die overeenstemt met <strong>de</strong> integratie <strong>van</strong> <strong>het</strong> spectrum<br />

<strong>van</strong> <strong>de</strong> belasting, m.a.w. :<br />

− voor een constante belasting : <strong>de</strong> toepassingsduur <strong>van</strong> <strong>de</strong> belasting<br />

− voor een veran<strong>de</strong>rlijke belasting : <strong>de</strong> integraal <strong>van</strong> <strong>het</strong> spectrum <strong>van</strong> <strong>de</strong> belasting,<br />

teruggebracht <strong>op</strong> <strong>de</strong> piekbelasting.<br />

Wat <strong>de</strong> wind betreft, dient men dus niet zozeer rekening te hou<strong>de</strong>n met <strong>de</strong> tijd die<br />

overeenkomt met <strong>de</strong> piekdruk (veroorzaakt door een rukwind), maar veeleer met een tijd «t»,<br />

die overeenstemt met <strong>het</strong> spectrum <strong>van</strong> <strong>de</strong> druk (storm), teruggebracht <strong>op</strong> <strong>de</strong> piekdruk <strong>van</strong> <strong>de</strong><br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

140


storm voor <strong>de</strong> gekozen terugkeerperio<strong>de</strong>. De volgen<strong>de</strong> tabel stelt <strong>de</strong> karakteristieke duur <strong>van</strong><br />

elke afzon<strong>de</strong>rlijke belasting voor, evenals <strong>de</strong> tijdsduurfactor kmod.<br />

Tabel A7-2 Tijdsduurfactor kmod.<br />

Veran<strong>de</strong>rlijke belastingen qk,i<br />

Stormwind w kort<br />

Spectrum <strong>van</strong> <strong>de</strong> belasting<br />

Tijdsduur Karakteristiek<br />

Herhaal<strong>de</strong><br />

piekdrukken<br />

Tijd «t» die<br />

overeenstemt<br />

met <strong>de</strong><br />

integraal <strong>van</strong><br />

<strong>het</strong> spectrum<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

kmod,ind<br />

10 minuten 0,74<br />

Sneeuw sk gemid<strong>de</strong>ld Constante druk 1 maand 0,44<br />

Borstweringsfunctie Ab kort Eén enkele piekdruk 0,5 minuut 0,89<br />

Blijven<strong>de</strong> belastingen gk of an<strong>de</strong>re<br />

Eigengewicht gk of an<strong>de</strong>re lang Onveran<strong>de</strong>rlijke druk 25 jaar 0,30<br />

In <strong>het</strong> geval <strong>van</strong> een belastingscombinatie verkrijgt men <strong>de</strong> kmod,combi-factor door rekening te<br />

hou<strong>de</strong>n met elke nettobelasting en zijn kmod,ind-factor, via <strong>de</strong> volgen<strong>de</strong> vergelijking :<br />

σ g + σ q + ∑σ<br />

k k , 1<br />

q k,<br />

i<br />

i<br />

kmod,<br />

combi =<br />

, waarbij<br />

σ σ<br />

g k<br />

q σ<br />

k , 1<br />

q k,<br />

i<br />

+ + ∑<br />

kmod,<br />

ind , qk kmod,<br />

ind , qk1<br />

i k mod, ind , qki<br />

− σg,k : <strong>de</strong> buigspanning tengevolge <strong>van</strong> <strong>het</strong> eigengewicht γG.gk<br />

− σq,k,1 : <strong>de</strong> buigspanning tengevolge <strong>van</strong> <strong>de</strong> dominante veran<strong>de</strong>rlijke belasting γQ,1.qk,1<br />

− σq,k,i : <strong>de</strong> buigspanning tengevolge <strong>van</strong> <strong>de</strong> begelei<strong>de</strong>n<strong>de</strong> veran<strong>de</strong>rlijke belasting<br />

ψ0,i.γQ,ki.qk,i.<br />

Als men uitgaat <strong>van</strong> <strong>de</strong> veron<strong>de</strong>rstelling dat alle belastingen gelijkmatig ver<strong>de</strong>eld zijn over <strong>het</strong><br />

gehele <strong>op</strong>pervlak, is <strong>de</strong> volgen<strong>de</strong> equivalente vergelijking toepasbaar voor <strong>het</strong> lineaire mo<strong>de</strong>l<br />

en levert <strong>de</strong>ze gewoonlijk een aanvaardbare bena<strong>de</strong>ring <strong>op</strong> voor <strong>het</strong> niet-lineaire mo<strong>de</strong>l :<br />

γ G × g k + γ Q,<br />

1 × qk<br />

, 1 + ∑γ<br />

qk , i × ψ 0,<br />

i × qk<br />

, i<br />

kmod,<br />

combi =<br />

γ G × g k<br />

k<br />

i<br />

γ Q,<br />

1 × qk<br />

, 1 γ Qk,<br />

i × ψ 0,<br />

i × qk<br />

, i<br />

+ + ∑<br />

k<br />

k<br />

mod, ind , gk<br />

mod, ind , qk1<br />

A7-2.2.2. Dubbele isoleren<strong>de</strong> beglazing<br />

A7-2.2.2.1. Inwendige druk in <strong>de</strong> isoleren<strong>de</strong> beglazing<br />

i mod, ind , qki<br />

Een isoleren<strong>de</strong> beglazing kan <strong>het</strong> voorwerp uitmaken <strong>van</strong> inwendige drukverschillen. Deze<br />

wor<strong>de</strong>n vooral veroorzaakt door <strong>de</strong> temperatuurschommelingen en hoogteverschillen tussen<br />

<strong>de</strong> plaats waar <strong>de</strong> isoleren<strong>de</strong> beglazing geproduceerd werd en haar uitein<strong>de</strong>lijke plaats <strong>van</strong><br />

toepassing. Zodra <strong>de</strong> beglazing afgekit wordt, kunnen <strong>de</strong> variaties <strong>van</strong> <strong>de</strong> atmosferische druk<br />

bovendien <strong>het</strong> evenwicht tussen <strong>de</strong> inwendige druk en <strong>de</strong> uitwendige druk <strong>van</strong> <strong>de</strong> beglazing<br />

verstoren, wat aanleiding kan geven tot een vervorming. Deze vervorming vertaalt zich door<br />

<strong>de</strong> uitrekking <strong>van</strong> <strong>de</strong> dichtingsvoeg en door <strong>de</strong> doorbuiging <strong>van</strong> <strong>de</strong> beglazing. Dit verschijnsel<br />

is dus niet isochoor, zodat een geringe vervorming <strong>van</strong> <strong>de</strong> isoleren<strong>de</strong> beglazing reeds kan<br />

141


lei<strong>de</strong>n tot een aanzienlijke vermin<strong>de</strong>ring <strong>van</strong> <strong>de</strong> inwendige druk. Deze drukverschillen zijn<br />

voor <strong>de</strong> courante situaties bijgevolg verwaarloosbaar.<br />

Indien <strong>de</strong> beglazing omwille <strong>van</strong> haar <strong>ontwerp</strong> niet kan vervormen, zullen <strong>de</strong> schommelingen<br />

<strong>van</strong> <strong>de</strong> inwendige druk echter aanleiding geven tot aanzienlijke spanningen. Een volledige<br />

bena<strong>de</strong>ring is evenwel enkel mogelijk met behulp <strong>van</strong> gesofisticeer<strong>de</strong> computerapparatuur,<br />

<strong>het</strong>zij met <strong>de</strong> eindige-elementenmetho<strong>de</strong>, <strong>het</strong>zij door gebruik te maken <strong>van</strong> ingewikkel<strong>de</strong><br />

fysische formules waarbij rekening gehou<strong>de</strong>n wordt met parameters zoals <strong>de</strong> karakteristieken<br />

<strong>van</strong> <strong>de</strong> ingesloten gassen, <strong>de</strong> temperatuur, <strong>de</strong> druk die tij<strong>de</strong>ns <strong>de</strong> fabricage heerste in <strong>het</strong><br />

atelier, <strong>de</strong> atmosferische druk, ...<br />

P e P i + i<br />

Δ g<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

Δ b<br />

Afbeelding A7 - 1 Isoleren<strong>de</strong> beglazing – Vervorming Δpi.<br />

Wij stellen bijgevolg voor om <strong>de</strong> volgen<strong>de</strong> han<strong>de</strong>lswijze te volgen. In aanwezigheid <strong>van</strong> een<br />

weinig vervormbare isoleren<strong>de</strong> beglazing, d.w.z. :<br />

- indien <strong>de</strong> glasdikte <strong>van</strong> <strong>de</strong> isoleren<strong>de</strong> beglazing overgedimensioneerd werd ten <strong>op</strong>zichte<br />

<strong>van</strong> <strong>de</strong> rekenwaar<strong>de</strong>n voor <strong>de</strong> belastingen of <strong>de</strong> belastingscombinatie uit § A7-4 (bv. een<br />

explosiebestendige of kogelweren<strong>de</strong> beglazing, …)<br />

- indien één <strong>van</strong> <strong>de</strong> afmetingen kleiner is dan 0,7 m,<br />

wordt aanbevolen rekening te hou<strong>de</strong>n met <strong>de</strong> minimale glasdikten die <strong>op</strong>gegeven zijn in<br />

tabel A7-3. Hierin is ‘a’ <strong>de</strong> kleine zij<strong>de</strong> <strong>van</strong> <strong>de</strong> beglazing en ‘λ = b/a’ <strong>de</strong> verhouding tussen <strong>de</strong><br />

grote en <strong>de</strong> kleine zij<strong>de</strong> <strong>van</strong> <strong>de</strong> beglazing.<br />

Tabel A7-3 Beglazing – Inwendige druk – Minimale dikten.<br />

Minimale dikten<br />

a (m) λ ≤ 1 λ ≤ 2,5 λ ≥ 2,5<br />

0,4 4 + 4 5 + 5 6 + 6<br />

0,5 4 + 4 4 + 4 6 + 6<br />

0,6 4 + 4 4 + 4 4 + 4<br />

Δg<br />

Pi + Δi<br />

Δb<br />

142


A7-2.2.2.2. Krachtenver<strong>de</strong>ling over <strong>de</strong> lagen <strong>van</strong> een isoleren<strong>de</strong> beglazing<br />

A7-2.2.2.2.1. Eerste bena<strong>de</strong>ring<br />

De belasting of <strong>de</strong> resulteren<strong>de</strong> belastingscombinatie ver<strong>de</strong>elt zich als volgt over <strong>de</strong> glaslagen.<br />

Indien h1 en h2 <strong>de</strong> nominale dikten <strong>van</strong> <strong>de</strong> lagen <strong>van</strong> <strong>de</strong> isoleren<strong>de</strong> beglazing voorstellen,<br />

berekent men <strong>de</strong> coëfficiënten voor <strong>de</strong> belastingsver<strong>de</strong>ling zoals hierna weergegeven :<br />

3<br />

h1<br />

1 3 3<br />

h h<br />

3<br />

h2<br />

2 3 3<br />

h h<br />

1 1<br />

.<br />

1<br />

2<br />

Rekening hou<strong>de</strong>nd met <strong>de</strong> inwendige druk in <strong>de</strong> isoleren<strong>de</strong> beglazing, ver<strong>de</strong>elt <strong>de</strong> resulteren<strong>de</strong><br />

belasting zich dus als volgt :<br />

voor <strong>het</strong> glas met glasdikte h1 : Fd,1 = 1 x Fd<br />

voor <strong>het</strong> glas met glasdikte h2 : Fd,2 = 2 x Fd.<br />

A7-2.2.2.2.2. Meer precieze bena<strong>de</strong>ring<br />

Als men preciezer wil zijn, kan men rekening hou<strong>de</strong>n met <strong>het</strong> feit dat <strong>de</strong> externe belastingen<br />

F<strong>de</strong>,1 en F<strong>de</strong>,2, die elk aangrijpen <strong>op</strong> één <strong>van</strong> <strong>de</strong> twee lagen <strong>van</strong> <strong>de</strong> isoleren<strong>de</strong> beglazing<br />

ge<strong>de</strong>eltelijk <strong>op</strong>genomen wor<strong>de</strong>n door <strong>de</strong> an<strong>de</strong>re laag <strong>van</strong> <strong>de</strong> isoleren<strong>de</strong> beglazing. De externe<br />

belastingen F<strong>de</strong>,1 en F<strong>de</strong>,2 ver<strong>de</strong>len zich als volgt over elk <strong>van</strong> bei<strong>de</strong> lagen <strong>van</strong> <strong>de</strong> beglazing :<br />

Fd,1 = (1 + x 2) x F<strong>de</strong>,1 + (1- ) x 1 x F<strong>de</strong>,2<br />

Fd,2 = (1 - x 2 x F<strong>de</strong>,1 + (2 + x 1) x F<strong>de</strong>,2.<br />

In <strong>de</strong>ze uitdrukkingen vertegenwoordigt φ <strong>de</strong> factor voor <strong>de</strong> isoleren<strong>de</strong> beglazing, die<br />

overeenstemt met :<br />

1<br />

<br />

, waarbij<br />

4<br />

1<br />

( a / a*)<br />

a : <strong>de</strong> breedte (kortste zij<strong>de</strong>) <strong>van</strong> <strong>de</strong> beglazing<br />

a* : <strong>de</strong> karakteristieke breedte <strong>van</strong> <strong>de</strong> beglazing, die gelijk is aan<br />

0,<br />

25<br />

3 3 s h1<br />

h 2<br />

a * 28,<br />

9<br />

<br />

<br />

3 3 1 2 <br />

, waarin<br />

h h k5<br />

<br />

- s : <strong>de</strong> breedte <strong>van</strong> <strong>de</strong> afstandhou<strong>de</strong>r<br />

- k5 : <strong>de</strong> factor voor <strong>de</strong> volumeveran<strong>de</strong>ring, die gegeven wordt door <strong>de</strong> volgen<strong>de</strong><br />

vergelijking :<br />

z1<br />

1,33<br />

k5 0, 4198 0,22exp 6,8 <br />

2<br />

,<br />

<br />

16 <br />

<br />

waarvoor z1 gegeven wordt in § A7-3.3.2, en λ <strong>de</strong> slankheid <strong>van</strong> <strong>de</strong> glasplaat voorstelt<br />

(λ = a/b).<br />

=a/b 1,0 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1<br />

k5 0,0194 0,0237 0,0288 0,0350 0,0372 0,0421 0,0587 0,0676 0,0767 0,0857<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

1<br />

2<br />

1,33<br />

<br />

z1<br />

<br />

k5 0, 4198 0,22 exp 6,8 <br />

<br />

2 <br />

16 <br />

<br />

143


A7-2.2.3. Driedubbele beglazing<br />

Indien h1, h2 en h3 <strong>de</strong> dikten <strong>van</strong> <strong>de</strong> lagen <strong>van</strong> <strong>de</strong> isoleren<strong>de</strong> beglazing voorstellen (met h2 : <strong>de</strong><br />

mid<strong>de</strong>lste glaslaag), berekent men <strong>de</strong> coëfficiënten voor <strong>de</strong> belastingsverliezen als volgt :<br />

3<br />

3<br />

3<br />

h1<br />

h2<br />

h3<br />

1 <br />

3 3 3 2 <br />

3 3 3 3 <br />

.<br />

3 3 3<br />

h h h h h h h h h<br />

1<br />

2<br />

De resulteren<strong>de</strong> belasting uit zich dus zoals hierna weergegeven :<br />

voor <strong>het</strong> glas met glasdikte h1 : Fd,1 = 1 x Fd<br />

voor <strong>het</strong> glas met glasdikte h2 : Fd , 2 2 Fd<br />

voor <strong>het</strong> glas met glasdikte h3 : Fd,3 = 3 x Fd.<br />

A7-2.2.4. Gelaagd glas<br />

3<br />

Gelaagd glas is monolitisch glas dat bestaat uit verschillen<strong>de</strong> lagen die over hun volledige<br />

<strong>op</strong>pervlak gesolidariseerd zijn door mid<strong>de</strong>l <strong>van</strong> een organische tussenlaag. Deze tussenlaag<br />

kan al dan niet in staat zijn <strong>de</strong> afschuifkrachten tussen <strong>de</strong> lagen <strong>van</strong> <strong>het</strong> gelaag<strong>de</strong> glas over te<br />

dragen, afhankelijk <strong>van</strong> zijn kwaliteit, <strong>de</strong> tijdsduur <strong>van</strong> <strong>de</strong> belastingen en <strong>de</strong> temperatuur. Om<br />

rekening te hou<strong>de</strong>n met dit aspect werd een effectieve dikte hef in <strong>het</strong> rekenmo<strong>de</strong>l ingevoerd.<br />

Wanneer <strong>de</strong> tijdsduur <strong>van</strong> <strong>de</strong> belasting of <strong>de</strong> belastingscombinatie kort is, is <strong>de</strong> PVBtussenlaag<br />

<strong>van</strong> <strong>het</strong> gelaag<strong>de</strong> veiligheidsglas gewoonlijk in zekere mate in staat om <strong>de</strong><br />

overdracht <strong>van</strong> <strong>de</strong> afschuifkrachten tussen <strong>de</strong> glaslagen te waarborgen.<br />

Bij <strong>de</strong> bepaling <strong>van</strong> <strong>de</strong> vervorming, is <strong>de</strong> effectieve dikte die in aanmerking genomen wordt in<br />

<strong>de</strong> berekening gelijk aan :<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

1<br />

3<br />

h h <br />

3<br />

3<br />

ef ; w 1 i<br />

i i<br />

i<br />

h .<br />

Voor <strong>de</strong> bepaling <strong>van</strong> <strong>de</strong> spanning in <strong>de</strong> laag j, is <strong>de</strong> effectieve dikte die in aanmerking<br />

genomen wordt in <strong>de</strong> berekening gelijk aan :<br />

3 hef ; w <br />

hef<br />

; ; j <br />

.<br />

h 2 <br />

h<br />

<br />

j<br />

In <strong>de</strong>ze uitdrukkingen is :<br />

: <strong>de</strong> overdrachtscoëfficiënt, begrepen tussen 0 (geen overdracht <strong>van</strong> <strong>de</strong> afschuifkrachten)<br />

en 1 (volledige overdracht <strong>van</strong> <strong>de</strong> afschuifkrachten)<br />

hi en hj : <strong>de</strong> nominale dikten <strong>van</strong> <strong>de</strong> glaslagen<br />

hm;j : <strong>de</strong> afstand tussen <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> laag j en <strong>het</strong> mid<strong>de</strong>n <strong>van</strong> <strong>het</strong> gelaag<strong>de</strong> glas,<br />

zon<strong>de</strong>r <strong>de</strong> dikte <strong>van</strong> <strong>de</strong> tussenlagen in rekening te brengen.<br />

Wanneer <strong>de</strong> glaslagen <strong>de</strong>zelf<strong>de</strong> spanningsrekenwaar<strong>de</strong>n vertonen, is <strong>de</strong> effectieve dikte die in<br />

aanmerking moet genomen wor<strong>de</strong>n gelijk aan <strong>de</strong> minimale dikte, verkregen bij <strong>de</strong> berekening<br />

<strong>van</strong> <strong>de</strong> effectieve dikte hef,σ,j <strong>van</strong> <strong>de</strong> verschillen<strong>de</strong> lagen, hef,σ = minimum hef,σ,j.<br />

2<br />

3<br />

m;<br />

j<br />

1<br />

2<br />

3<br />

144


2<br />

h1<br />

h2<br />

h3<br />

hm;1<br />

hm;2<br />

1 Mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> dikte <strong>van</strong> elke glaslaag<br />

2 Mid<strong>de</strong>n <strong>van</strong> <strong>de</strong> dikte <strong>van</strong> <strong>het</strong> gelaag<strong>de</strong> glas<br />

Afbeelding A7 - 2 Bepaling <strong>van</strong> <strong>de</strong> dikte <strong>van</strong> een gelaagd glas.<br />

De waar<strong>de</strong> <strong>van</strong> <strong>de</strong> overdrachtscoëfficiënt ϖ kan <strong>op</strong>gegeven wor<strong>de</strong>n door <strong>de</strong> fabrikant en moet<br />

bovendien wetenschappelijk on<strong>de</strong>rbouwd zijn. Bij gebrek aan na<strong>de</strong>re informatie, of in<br />

gevallen die afwijken <strong>van</strong> <strong>de</strong> hiervoor vermel<strong>de</strong>, dient men rekening te hou<strong>de</strong>n met een<br />

overdrachtscoëfficiënt ϖ <strong>van</strong> 0,0.<br />

Tabel A7- 4 Overdrachtscoëfficiënt ϖ voor <strong>de</strong> afschuifkrachten <strong>van</strong> <strong>de</strong> tussenlaag.<br />

Belastingen <strong>op</strong> <strong>de</strong> gevel t ϖ<br />

Wind Fd (w) 10 minuten 0,2<br />

Borstweringsfunctie Fd (Ab) 1 minuut 0,2<br />

Belastingen en belastingscombinaties <strong>op</strong> hellen<strong>de</strong> daken en gevels 0,0<br />

De tabel hieron<strong>de</strong>r geeft <strong>de</strong> effectieve dikten voor <strong>de</strong> berekening <strong>van</strong> <strong>de</strong> spanning en <strong>de</strong><br />

overeenkomstige vervorming voor een gelaagd veiligheidsglas, <strong>op</strong>gebouwd uit twee lagen<br />

met gelijke dikte.<br />

Tabel A7- 5 Equivalente dikten voor gelaagd glas.<br />

Dikte <strong>van</strong> <strong>het</strong> glas ϖ = 0,2 (belastingen <strong>van</strong> korte duur) ϖ = 0,0<br />

(mm) hef;w (mm) hef;σ;j (mm) hef;w (mm) hef;σ;j (mm)<br />

3 + 3 4,42 4,90 3,78 4,24<br />

4 + 4 5,89 6,53 5,04 5,66<br />

5 + 5 7,34 8,17 6,30 7,07<br />

6 + 6 8,84 9,80 7,56 8,49<br />

8 + 8 11,79 13,06 10,08 11,31<br />

10 + 10 14,74 16,33 12,60 14,14<br />

Nota A7-1 : <strong>de</strong> berekening <strong>van</strong> <strong>de</strong> belastingsver<strong>de</strong>ling tussen <strong>de</strong> lagen <strong>van</strong> een gelaagd glas<br />

gebeurt met behulp <strong>van</strong> <strong>de</strong> equivalente dikte on<strong>de</strong>r vervorming «h ef;w ».<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

hm;3<br />

1<br />

145


A7-3. Rekenmo<strong>de</strong>llen<br />

A7-3.1. Algemeen<br />

A7-3.1.1. Gebruiksgrenstoestand : berekening <strong>van</strong> <strong>de</strong> vervorming<br />

De berekening <strong>van</strong> <strong>de</strong> vervorming kan zeer nuttig zijn, on<strong>de</strong>r meer wanneer er voldaan moet<br />

wor<strong>de</strong>n aan een aantal functionele criteria :<br />

- bij gebruik <strong>van</strong> thermisch behan<strong>de</strong>ld glas dat blootstaat aan zware belastingen (bv. om <strong>het</strong><br />

onveiligheidsgevoel <strong>van</strong> <strong>de</strong> gebruikers bij sterke wind te vermij<strong>de</strong>n)<br />

- bij gebruik <strong>van</strong> producten waarbij <strong>de</strong> vervorming beperkt moet blijven om <strong>de</strong> goe<strong>de</strong><br />

werking er<strong>van</strong> te waarborgen (bv. isoleren<strong>de</strong> beglazing).<br />

In <strong>de</strong>rgelijke gevallen dient men <strong>de</strong> maximale vervorming te bepalen ten <strong>op</strong>zichte <strong>van</strong> <strong>de</strong><br />

functionaliteit die men wenst te verzekeren. Voor isoleren<strong>de</strong> beglazingen wordt in bijlage B3<br />

<strong>van</strong> <strong>de</strong> norm NBN EN 1279-5 aanbevolen om <strong>de</strong> vervorming <strong>van</strong> <strong>de</strong> ran<strong>de</strong>n <strong>van</strong> <strong>de</strong> beglazing<br />

te beperken tot 1/200 of tot maximum 12 mm.<br />

A7-3.1.2. Uiterste grenstoestand : berekening <strong>van</strong> <strong>de</strong> spanning<br />

De uiterste grenstoestand moet altijd gecontroleerd wor<strong>de</strong>n.<br />

A7-3.1.3. Lineair mo<strong>de</strong>l<br />

Het lineaire mo<strong>de</strong>l is doorgaans precies genoeg voor beglazingen waarbij <strong>de</strong> vervorming in <strong>de</strong><br />

gebruiksgrenstoestand niet groter is dan 1 maal <strong>de</strong> glasdikte. Dit is gewoonlijk <strong>het</strong> geval<br />

wanneer <strong>de</strong> spanning in <strong>het</strong> glas in <strong>de</strong> uiterste grenstoestand beperkt is tot min<strong>de</strong>r dan 20 MPa<br />

(bv. in geval <strong>van</strong> uitgegloeid floatglas). We willen er ook <strong>op</strong> wijzen dat <strong>de</strong> strikt<br />

noodzakelijke glasdikte met <strong>de</strong> lineaire metho<strong>de</strong> <strong>de</strong>s te meer overschat wordt, naarmate <strong>de</strong><br />

slankheid <strong>van</strong> <strong>de</strong> beglazing λ (= a/b) dichter bij 1 ligt.<br />

A7-3.1.4. Niet-lineair mo<strong>de</strong>l<br />

Het niet-lineaire mo<strong>de</strong>l is geschikt voor beglazingen waarbij <strong>de</strong> vervorming in <strong>de</strong><br />

gebruiksgrenstoestand hoger is dan 1 maal <strong>de</strong> glasdikte. Dit is gewoonlijk <strong>het</strong> geval wanneer<br />

<strong>de</strong> spanning in <strong>het</strong> glas groter is dan 20 MPa (bv. in geval <strong>van</strong> thermisch behan<strong>de</strong>ld glas).<br />

Voor bepaal<strong>de</strong> glasproducten (bv. isoleren<strong>de</strong> beglazing) dient <strong>de</strong> vervorming beperkt te<br />

wor<strong>de</strong>n om hun goe<strong>de</strong> werking en duurzaamheid te waarborgen.<br />

A7-3.1.5. Symbolen en afkortingen<br />

In <strong>de</strong> formules <strong>van</strong> § A7-3.2 dient men er<strong>op</strong> toe te zien dat er voor <strong>de</strong> diverse parameters<br />

homogene eenhe<strong>de</strong>n gehanteerd wor<strong>de</strong>n, met name <strong>de</strong> Newton (N) en <strong>de</strong> millimeter (mm) :<br />

• a, <strong>de</strong> kleinste afmeting <strong>van</strong> <strong>de</strong> glasplaat [mm]<br />

• b, <strong>de</strong> grootste afmeting <strong>van</strong> <strong>de</strong> glasplaat [mm]<br />

• A, <strong>de</strong> <strong>op</strong>pervlakte <strong>van</strong> <strong>de</strong> glasplaat : A = a x b [mm²]<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

146


• λ, <strong>de</strong> slankheid <strong>van</strong> <strong>de</strong> glasplaat : λ = a/b<br />

• k1, <strong>de</strong> spanningscoëfficiënt<br />

• k4, <strong>de</strong> vervormingscoëfficiënt<br />

• h, <strong>de</strong> nominale dikte <strong>van</strong> <strong>de</strong> beglazing [mm]<br />

• p*, <strong>de</strong> adimensionale belastingscoëfficiënt<br />

• Fd, <strong>de</strong> rekenwaar<strong>de</strong> <strong>van</strong> <strong>de</strong> belastingscombinatie [N/mm²]<br />

• L, <strong>de</strong> vrije overspanning <strong>van</strong> <strong>de</strong> glasplaat [mm]<br />

• emin,w, <strong>de</strong> minimale glasdikte die beantwoordt aan <strong>het</strong> vervormingscriterium in <strong>de</strong> GGT<br />

• emin,σ, <strong>de</strong> minimale glasdikte die beantwoordt aan <strong>het</strong> belastingscriterium in <strong>de</strong> UGT<br />

• ymax, <strong>de</strong> maximale doorbuiging die beantwoordt aan <strong>het</strong> vervormingscriterium in <strong>de</strong> GGT<br />

[mm]<br />

• wmax, <strong>de</strong> maximale doorbuiging [mm].<br />

A7-3.2. Gelijkmatig belaste rechthoekige plaat, gewoon <strong>op</strong>gelegd <strong>op</strong> twee<br />

ran<strong>de</strong>n<br />

In dit geval is er geen uitgesproken verschil tussen <strong>het</strong> lineaire en <strong>het</strong> niet-lineaire mo<strong>de</strong>l.<br />

Vermits <strong>het</strong> eenvoudigere lineaire mo<strong>de</strong>l wordt aangenomen, dient <strong>de</strong> te voorziene nominale<br />

glasdikte h aan <strong>de</strong> volgen<strong>de</strong> eisen te voldoen : h ≥ emin,σ en h ≥ emin,w. Voor <strong>de</strong> bepaling <strong>van</strong><br />

emin,σ en emin,w verwijzen we naar <strong>de</strong> volgen<strong>de</strong> paragrafen.<br />

A7-3.2.1. UGT – Berekening <strong>van</strong> <strong>de</strong> belasting<br />

De maximale spanning wordt berekend aan <strong>de</strong> hand <strong>van</strong> <strong>de</strong> volgen<strong>de</strong> formule :<br />

2<br />

⎛ L ⎞<br />

σ max = 0,<br />

75×<br />

⎜ ⎟ × Fd<br />

.<br />

⎝ h ⎠<br />

Hieruit kan men <strong>de</strong> minimale dikte <strong>van</strong> <strong>de</strong> beglazing aflei<strong>de</strong>n, die beantwoordt aan <strong>het</strong><br />

belastingscriterium :<br />

2<br />

L<br />

e min , σ = 0,<br />

75×<br />

× F<br />

X<br />

A7-3.2.2. GGT – Berekening <strong>van</strong> <strong>de</strong> vervorming<br />

De maximale vervorming wordt berekend met behulp <strong>van</strong> <strong>de</strong> volgen<strong>de</strong> formule :<br />

4<br />

60 × L × Fd<br />

wmax<br />

= .<br />

384×<br />

E × h³<br />

Hieruit kan men <strong>de</strong> minimale nominale dikte <strong>van</strong> <strong>de</strong> beglazing aflei<strong>de</strong>n, die beantwoordt aan<br />

<strong>het</strong> vervormingscriterium :<br />

4<br />

60×<br />

Fd<br />

× L<br />

e 3<br />

min , w = .<br />

384×<br />

E × y<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

g,<br />

d<br />

max<br />

d<br />

147


A7-3.3. Gelijkmatig belaste rechthoekige plaat, gewoon <strong>op</strong>gelegd <strong>op</strong> vier<br />

ran<strong>de</strong>n<br />

De hierna vermel<strong>de</strong> formules zijn geldig voor een Poisson-coëfficiënt 0,20 ≤ ν ≤ 0,24.<br />

A7-3.3.1. Studie <strong>van</strong> <strong>de</strong> belasting<br />

De maximale spanning in <strong>de</strong> plaat wordt gegeven door <strong>de</strong> vergelijking :<br />

A<br />

σ max = k 1 × × F 2 d ,<br />

h<br />

1<br />

waarin : k 1 =<br />

0,<br />

5 ,<br />

2<br />

⎡ 1 p * ⎤<br />

4x4⎢<br />

+ 2 2<br />

2 ⎥<br />

⎣ z2<br />

( z3<br />

+ ( z4<br />

× p * ) ) ⎦<br />

⎡<br />

1,<br />

073<br />

⎛ ⎛<br />

⎞⎞⎤<br />

met<br />

⎢<br />

⎜ ⎜ ⎛ 1 ⎞<br />

z<br />

⎟⎟<br />

2 = 24×<br />

λ × 0,<br />

0447 + 0,<br />

0803×<br />

1−<br />

exp −1,<br />

17 ×<br />

⎥<br />

⎢<br />

⎜ ⎜<br />

⎜ −1⎟<br />

⎟⎟<br />

⎣<br />

⎝ ⎝ ⎝ λ ⎠ ⎠⎠⎥<br />

⎦<br />

2<br />

⎛ 1 ⎞<br />

z 3 = 4,<br />

5×<br />

⎜ −1⎟<br />

+ 4,<br />

5<br />

⎝ λ ⎠<br />

⎛ 1 ⎞<br />

z 4 = 0,<br />

585 − 0,<br />

05×<br />

⎜ −1⎟<br />

⎝ λ ⎠<br />

en p*, <strong>de</strong> adimensionale belastingscoëfficiënt die <strong>de</strong> volgen<strong>de</strong> waar<strong>de</strong>n aanneemt :<br />

− voor <strong>het</strong> lineaire rekenmo<strong>de</strong>l (kleine vervorming) : p* = 0 (in <strong>de</strong> praktijk moet in <strong>het</strong><br />

mo<strong>de</strong>l een p*-waar<strong>de</strong> <strong>van</strong> 0,00001 ingevoerd wor<strong>de</strong>n om geen mathematische<br />

onbepaaldheid te hebben)<br />

− voor <strong>het</strong> niet-lineaire rekenmo<strong>de</strong>l (grote vervorming) :<br />

⎛ A ⎞ Fd<br />

p*<br />

= ⎜ ⎟ × .<br />

2<br />

⎝ 4×<br />

h ⎠ E<br />

De volgen<strong>de</strong> tabel geeft <strong>de</strong> waar<strong>de</strong> <strong>van</strong> <strong>de</strong> belastingscoëfficiënt k1 <strong>op</strong>, rekening hou<strong>de</strong>nd met<br />

p* en met <strong>de</strong> slankheid <strong>van</strong> <strong>de</strong> plaat.<br />

Tabel A7- 6 Belastingscoëfficiënt k1<br />

λ = a/b<br />

0 1 2<br />

Adimensionale belastingscoëfficiënt p*<br />

3 5 10 20 50 100 200 300<br />

1,0 0,268 0,261 0,244 0,223 0,190 0,152 0,135 0,130 0,129 0,128 0,128<br />

0,9 0,287 0,278 0,258 0,234 0,197 0,155 0,137 0,131 0,130 0,129 0,129<br />

0,8 0,304 0,295 0,273 0,247 0,205 0,159 0,138 0,131 0,130 0,130 0,130<br />

0,7 0,314 0,306 0,285 0,261 0,218 0,165 0,140 0,130 0,129 0,129 0,129<br />

0,6 0,314 0,309 0,294 0,274 0,235 0,176 0,143 0,129 0,127 0,126 0,126<br />

0,5 0,300 0,298 0,290 0,279 0,253 0,197 0,151 0,128 0,124 0,123 0,122<br />

0,4 0,268 0,268 0,266 0,262 0,252 0,221 0,171 0,129 0,119 0,116 0,116<br />

0,3 0,217 0,217 0,217 0,216 0,215 0,208 0,189 0,141 0,116 0,107 0,105<br />

0,2 0,149 0,149 0,149 0,149 0,149 0,149 0,148 0,140 0,123 0,100 0,091<br />

0,1 0,075 0,075 0,075 0,075 0,075 0,075 0,075 0,075 0,075 0,074 0,073<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

2<br />

148


A7-3.3.2. Studie <strong>van</strong> <strong>de</strong> vervorming<br />

De maximale vervorming in <strong>de</strong> plaat wordt gegeven door <strong>de</strong> vergelijking :<br />

2<br />

A Fd<br />

wmax<br />

= k 4 × × ,<br />

3<br />

h E<br />

waarin :<br />

0,<br />

5<br />

⎡⎛<br />

1<br />

1 ⎞⎤<br />

2<br />

⎢⎜⎛<br />

⎞<br />

4 p * ⎟⎥<br />

4<br />

2<br />

⎢⎜<br />

⎜ + ×<br />

z ⎟ −<br />

1<br />

z ⎟<br />

⎝⎝<br />

⎠ 1 ⎠<br />

⎥<br />

⎢<br />

⎥<br />

⎢ 2 ⎥<br />

⎢<br />

⎥<br />

⎢<br />

⎥<br />

k<br />

⎣<br />

⎦<br />

4 = ,<br />

16 × p *<br />

met<br />

⎡<br />

⎛ ⎛<br />

2 2 ( ) ⎢<br />

⎜ ⎜ ⎛ 1 ⎞<br />

z 1 = 192 × 1−ν<br />

× λ × 0,<br />

00406 + 0,<br />

00896×<br />

1−<br />

exp −1,<br />

123×<br />

⎢<br />

⎜ ⎜<br />

⎜ −1⎟<br />

⎣<br />

⎝ ⎝ ⎝ λ ⎠<br />

en p* zoals <strong>op</strong>gegeven in § A7-3.3.1.<br />

Nota A7-2 : wanneer <strong>de</strong> belastingscoëfficiënt p* = 0, is <strong>de</strong> vervormingscoëfficiënt<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

0.<br />

5<br />

1,<br />

097<br />

⎞⎞⎤<br />

⎟⎟⎥<br />

⎟⎟<br />

⎠⎠⎥<br />

⎦<br />

z1<br />

k 4 = .<br />

16<br />

De volgen<strong>de</strong> tabel geeft <strong>de</strong> waar<strong>de</strong> <strong>van</strong> <strong>de</strong> vervormingscoëfficiënt k4, rekening hou<strong>de</strong>nd met<br />

<strong>de</strong> belastingscoëfficiënt p* en <strong>de</strong> slankheid <strong>van</strong> <strong>de</strong> plaat λ.<br />

Tabel A7- 7 Vervormingscoëfficiënt k4.<br />

Adimensionale belastingscoëfficiënt p*<br />

λ = a/b 0 1 2 3 5 10 20 50 100 200 300<br />

1,0 0,0461 0,0414 0,0354 0,0310 0,0255 0,0189 0,0137 0,0088 0,0062 0,0044 0,0036<br />

0,9 0,0452 0,0409 0,0351 0,0309 0,0254 0,0188 0,0136 0,0088 0,0062 0,0044 0,0036<br />

0,8 0,0437 0,0399 0,0346 0,0305 0,0253 0,0188 0,0136 0,0087 0,0062 0,0044 0,0036<br />

0,7 0,0404 0,0377 0,0333 0,0297 0,0248 0,0186 0,0136 0,0087 0,0062 0,0044 0,0036<br />

0,6 0,0354 0,0339 0,0309 0,0281 0,0240 0,0183 0,0134 0,0087 0,0062 0,0044 0,0036<br />

0,5 0,0287 0,0281 0,0267 0,0251 0,0222 0,0176 0,0132 0,0086 0,0062 0,0044 0,0036<br />

0,4 0,0208 0,0207 0,0204 0,0199 0,0187 0,0159 0,0125 0,0085 0,0061 0,0044 0,0036<br />

0,3 0,0128 0,0128 0,0127 0,0127 0,0125 0,0119 0,0105 0,0079 0,0059 0,0043 0,0035<br />

0,2 0,0059 0,0059 0,0059 0,0059 0,0059 0,0059 0,0058 0,0055 0,0048 0,0038 0,0033<br />

0,1 0,0015 0,0015 0,0015 0,0015 0,0015 0,0015 0,0015 0,0015 0,0015 0,0015 0,0015<br />

A7-3.4. Controle <strong>van</strong> <strong>de</strong> eigenfrequentie <strong>van</strong> beglazingen<br />

Indien <strong>de</strong> eigenfrequentie n <strong>van</strong> <strong>het</strong> glas kleiner is dan 5 Hz, verdwijnt <strong>het</strong> verwaarloosbare<br />

karakter <strong>van</strong> <strong>de</strong> trillingen en kan <strong>het</strong> nodig wor<strong>de</strong>n <strong>de</strong>ze in aanmerking te nemen, <strong>het</strong>zij door<br />

<strong>de</strong> veiligheid tegen trillingen na te gaan, <strong>het</strong>zij door <strong>de</strong> eigenfrequentie te verhogen. Trillingen<br />

doen zich voornamelijk voor in elementen met een grote overspanning.<br />

149


In <strong>het</strong> geval <strong>van</strong> een enkele beglazing, <strong>op</strong>gelegd <strong>op</strong> twee of vier ran<strong>de</strong>n, is <strong>de</strong> eigenfrequentie<br />

<strong>van</strong> <strong>de</strong> eerste trillingsmodulus n1 gelijk aan :<br />

π ⎛<br />

⎜ ⎛ a ⎞<br />

× 1+<br />

2 ⎜<br />

⎜ ⎟<br />

⎝ ⎝ b ⎠<br />

⎞<br />

⎟<br />

⎠<br />

2<br />

3<br />

E × hef<br />

; w<br />

n1<br />

= ⎟ ×<br />

−9<br />

4<br />

12×<br />

10 × ρ × htot<br />

× a × ( 1−ν<br />

²)<br />

waarbij<br />

− a : <strong>de</strong> kleinste afmeting <strong>van</strong> <strong>de</strong> beglazing [mm]<br />

− b : <strong>de</strong> grootste afmeting <strong>van</strong> <strong>de</strong> beglazing [mm]<br />

− E : <strong>de</strong> elasticiteitsmodulus = 70000 [N/mm²]<br />

− hef,w : <strong>de</strong> glasdikte in geval <strong>van</strong> monolitisch glas of <strong>de</strong> effectieve dikte bij vervorming in<br />

geval <strong>van</strong> gelaagd glas [mm]<br />

− htot : <strong>de</strong> totale dikte <strong>van</strong> <strong>de</strong> beglazing [mm]<br />

− ρ : <strong>de</strong> dichtheid <strong>van</strong> <strong>het</strong> glas = 2,5<br />

− ν : <strong>de</strong> Poisson-coëfficiënt <strong>van</strong> <strong>het</strong> glas = 0,2.<br />

Aan <strong>de</strong> hand <strong>van</strong> <strong>de</strong>ze uitdrukking en <strong>de</strong> glaskarakteristieken verkrijgen we dan <strong>de</strong> volgen<strong>de</strong><br />

formule :<br />

2<br />

3<br />

⎛ 6 a ⎞ hef<br />

, w<br />

n1<br />

2,<br />

4489 10 ⎜ ⎛ ⎞<br />

= × × 1+<br />

⎟ ×<br />

⎜<br />

⎜ ⎟<br />

4<br />

b ⎟<br />

⎝ ⎝ ⎠ ⎠ htot<br />

× a<br />

n1 ≥ 5Hz<br />

.<br />

A7-4. Belastingscombinaties en controle <strong>van</strong> <strong>de</strong> grenstoestan<strong>de</strong>n<br />

A7-4.1. Verticale gevel<br />

Belasting<br />

Wind<br />

Vulelement<br />

Rekenwaar<strong>de</strong> Criterium<br />

GGT : Fd(w) = 0,83 ce(z)qref 50jaar cp<br />

UGT : Fd(w) = 1,01 ce(z)qref 50jaar cp<br />

Doorgaans niet noodzakelijk. Het eventuele<br />

vervormingscriterium dat geformuleerd moet<br />

wor<strong>de</strong>n, betreft <strong>de</strong> functionaliteit of <strong>de</strong> duurzaamheid<br />

<strong>van</strong> <strong>het</strong> product<br />

Ed(w) ≤ Xg,d<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

150


A7-4.2. Hellen<strong>de</strong> gevel of hellend dak<br />

Belastingscombinatie<br />

Eigengewicht<br />

+ wind<br />

Eigengewicht<br />

+ sneeuw<br />

Eigengewicht<br />

+ wind<br />

+ sneeuw<br />

Eigengewicht<br />

+ sneeuw<br />

+ wind<br />

Vulelement<br />

Rekenwaar<strong>de</strong> Criterium<br />

GGT :<br />

Fd(g,w) = gk + 0,83 ce(z)qref 50jaar cp<br />

UGT :<br />

Fd (g,w) = 1,1 gk + 1,01 ce(z)qref50jaar cp<br />

GGT :<br />

Fd(g,s) = gk + 0,88.µi.sk<br />

Doorgaans niet noodzakelijk. Het eventuele<br />

vervormingscriterium dat geformuleerd moet<br />

wor<strong>de</strong>n, betreft <strong>de</strong> functionaliteit of <strong>de</strong><br />

duurzaamheid <strong>van</strong> <strong>het</strong> product<br />

Ed(w) ≤ Xg,d<br />

Doorgaans niet noodzakelijk. Het eventuele<br />

vervormingscriterium dat geformuleerd moet<br />

wor<strong>de</strong>n, betreft <strong>de</strong> functionaliteit of <strong>de</strong><br />

duurzaamheid <strong>van</strong> <strong>het</strong> product<br />

UGT : Fd(g,s) = 1,1 gk + 0,965 µi.sk Ed(w) ≤ Xg,d<br />

UGT : Fd(g,w,s) =<br />

1,1.gk + 0,965.µi.sk +0,30 ce(z)qref 50jaar cp<br />

UGT : Fd(g,s,w) =<br />

1,1 gk +1,01 ce(z)qref 50jaar cp+ 0,29 µi.sk<br />

Ed(w) ≤ Xg,d<br />

Ed(w) ≤ Xg ,d<br />

Eigengewicht UGT : Fd(g,w,s) = 1,1 gk Ed(w) ≤ Xg,d<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

151


Verantwoor<strong>de</strong>lijke uitgever : Carlo De Pauw<br />

WTCB, Lombardstraat 42<br />

1000 BRUSSEL<br />

WTCB-Rapport nr. 11 <strong>Toepassing</strong> <strong>van</strong> <strong>de</strong> Euroco<strong>de</strong>s <strong>op</strong> <strong>het</strong> <strong>ontwerp</strong> <strong>van</strong> <strong>buitenschrijnwerk</strong><br />

2009<br />

D/2009/0611/02<br />

152


B R U S S E L<br />

Maatschappelijke zetel<br />

Lombardstraat 42<br />

B-1000 Brussel<br />

e-mail : info@bbri.be<br />

algemene directie<br />

<br />

<br />

Z A V E N T E M<br />

Kantoren<br />

Lozenberg 7<br />

B-1932 Sint-Stevens-Woluwe<br />

<br />

<br />

(Zaventem)<br />

02/716 42 11<br />

02/725 32 12<br />

technisch advies - communicatie - kwaliteit<br />

toegepaste informatica bouw<br />

planningtechnieken<br />

ontwikkeling & valorisatie<br />

publicaties<br />

<br />

<br />

02/502 66 90<br />

02/502 81 80<br />

02/529 81 00<br />

02/529 81 10<br />

L I M E L E T T E<br />

Proefstation<br />

Avenue Pierre Holoffe 21<br />

<br />

<br />

B-1342 Limelette<br />

02/655 77 11<br />

02/653 07 29<br />

on<strong>de</strong>rzoek & innovatie<br />

laboratoria<br />

vorming<br />

documentatie<br />

bibliotheek<br />

HEUSDEN-ZOLDER<br />

Demonstratie- en informatiecentrum<br />

Marktplein 7 bus 1<br />

<br />

<br />

B-3550 Heus<strong>de</strong>n-Zol<strong>de</strong>r<br />

011/22 50 65<br />

02/725 32 12<br />

ICT-kenniscentrum voor<br />

bouwprofessionelen (ViBo)

Hooray! Your file is uploaded and ready to be published.