TDS 1001/3 TDS 1201/4 - AL-KO
TDS 1001/3 TDS 1201/4 - AL-KO
TDS 1001/3 TDS 1201/4 - AL-KO
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Malfunctions<br />
!<br />
Before you attempt to remedy any malfunction of your pump, pull the plug to prevent injury<br />
or death due to electrocution!<br />
What is wrong? What is the possible reason? How to remedy the malfunction:<br />
Motor does not run. Impeller is blocked. Remove blockage in inlet area.<br />
Clean the impeller with a jet of<br />
water.<br />
Thermal switch has switched off. Wait until the thermal switch<br />
has automatically turned the<br />
pump on again. Check water<br />
temperature. Have the pump<br />
checked.<br />
No power. Have a qualified electrician<br />
check the power supply.<br />
Submersible pump runs but is<br />
not pumping out liquid.<br />
Submersible pump is only pumping<br />
out liquid very slowly or<br />
weakly.<br />
Float switch does not work even<br />
though liquid is above cut-in<br />
level.<br />
Air is trapped in the pump housing.<br />
Send pump to your nearest<br />
<strong>AL</strong>-<strong>KO</strong> service centre.<br />
Tilt the pump to let the trapped<br />
air out.<br />
Inlet strainer is blocked. Remove blockage and clean<br />
inlet strainer.<br />
Pressure line is blocked. Clear blockage in pressure<br />
line.<br />
The non-return valve is installed<br />
the wrong way round<br />
Install the non-return valve<br />
correctly (flap opens upwards)<br />
Pressure hose is bent. Straighten out pressure hose.<br />
Hose diameter is too small. Attach a hose with a larger<br />
diameter.<br />
Inlet strainer is blocked. Remove blockage and clean<br />
inlet strainer.<br />
Pumping height is too great. Lower pumping height.<br />
If you are unable to remedy a malfunction, please call the <strong>AL</strong>-<strong>KO</strong> service centre nearest you.<br />
Translation of original user instructions GB 4