Malfunctions<br />

!<br />

Before you attempt to remedy any malfunction of your pump, pull the plug to prevent injury<br />

or death due to electrocution!<br />

What is wrong? What is the possible reason? How to remedy the malfunction:<br />

Motor does not run. Impeller is blocked. Remove blockage in inlet area.<br />

Clean the impeller with a jet of<br />

water.<br />

Thermal switch has switched off. Wait until the thermal switch<br />

has automatically turned the<br />

pump on again. Check water<br />

temperature. Have the pump<br />

checked.<br />

No power. Have a qualified electrician<br />

check the power supply.<br />

Submersible pump runs but is<br />

not pumping out liquid.<br />

Submersible pump is only pumping<br />

out liquid very slowly or<br />

weakly.<br />

Float switch does not work even<br />

though liquid is above cut-in<br />

level.<br />

Air is trapped in the pump housing.<br />

Send pump to your nearest<br />

<strong>AL</strong>-<strong>KO</strong> service centre.<br />

Tilt the pump to let the trapped<br />

air out.<br />

Inlet strainer is blocked. Remove blockage and clean<br />

inlet strainer.<br />

Pressure line is blocked. Clear blockage in pressure<br />

line.<br />

The non-return valve is installed<br />

the wrong way round<br />

Install the non-return valve<br />

correctly (flap opens upwards)<br />

Pressure hose is bent. Straighten out pressure hose.<br />

Hose diameter is too small. Attach a hose with a larger<br />

diameter.<br />

Inlet strainer is blocked. Remove blockage and clean<br />

inlet strainer.<br />

Pumping height is too great. Lower pumping height.<br />

If you are unable to remedy a malfunction, please call the <strong>AL</strong>-<strong>KO</strong> service centre nearest you.<br />