31.07.2015 Views

4. Installation et montage - Kessel

4. Installation et montage - Kessel

4. Installation et montage - Kessel

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

8. Control of the septic system8.1.System menuSystem InformationSysteminfoTime: Uhrzeit: 00:00:00Floater: Schwimmer On/Off 1: Ein / AusTX: TX: (Phase T1 T1 - bis T24T24)TX1: TX1: (time: (Zeit: 00:00:00)InformationenMaintenanceWartungPositions EinstellungenB0 System InformationTime:Floater:T1 FeedingTX1< 00:05:54 FeedingDisplay of the hierarchy levelTimeDisplay of the activated floaters and their positionDisplay of the phaseDisplay of the currently expired time of the respective phaseDisplay of alarm/fault information8.2 Information menuInformationSysteminfo SysteminfoInformationenUhrzeit: Time: 00:00:00 Uhrzeit: 00:00:00Schwimmer Floater: Schwimmer 1: Ein On/Off / Aus 1: Ein / AusTX: (Phase TX: TX: T1 Phase (Phase bis T24) T1 T1 -bis T24T24)TX1: (Zeit: TX1:TX1: 00:00:00) (time: 00:00:00)(Zeit: 00:00:00)Wartung MaintenanceWartungPositions Einstellungen8.3 Maintenance menuSystemInformationSysteminfoInformationenMaintenance WartungPositions EinstellungenAttendend B<strong>et</strong>riebsstundenB timeEvents/ErrorsEreignisse / FehlerCommand Steuerungstyp typeMaintenance Wartungstermin DateWater Wasserhöhe levelParam<strong>et</strong>erman. Handb<strong>et</strong>rieb operationtest Testb<strong>et</strong>rieb operationMaintenance Wartungstermin Date8.2.2GIncidents / faultsDisplay of chronological faults and incidents (see alsochapter 10 "Malfunctions and remedial measures")All changes made to the s<strong>et</strong>tings are saved at this point.8.2.3 Control typeDisplay of purification class, size, language and softwareversion8.2.4 Maintenance deadlineDisplay of the next necessary and last performed maintenanceNote: Data are only available if these have been storedin the menu "S<strong>et</strong>tings" by the maintenance partner. (seealso 8.3.3)8.2.5 Water levelPressing the OK key carries out a measurement of thecurrent water level in the aeration basin.8.2.6 Param<strong>et</strong>ersDisplay of all s<strong>et</strong> control param<strong>et</strong>ers of the plant. Changingthe param<strong>et</strong>ers is not possible in this menu (see also8.<strong>4.</strong>1 and 8.<strong>4.</strong>2)8.3.1 Manual operationManual operation overrides automatic operation. Manualactivation of the ventilation plate lifters and of the aeratorspark plug.8.3.2 Test operationAutomatic test of the valves in the valve block. The compressoris not switched on during this process.123

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!