12.07.2015 Views

gb use and maintenance manual blast chiller/shock freezer

gb use and maintenance manual blast chiller/shock freezer

gb use and maintenance manual blast chiller/shock freezer

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

A total of 2 of the 6 available cycles can be personalized, namely CA3, selected by pressing button (23), <strong>and</strong> CC3selected with button (21).To personalize the cycles:- switch on the control unit with the ON/OFF button (10);- hold down PROG. button (7) for approx. 5 seconds;- the display shows the first parameter 3CA;- press the DISPLAY button (14);- the display shows the value of the parameter to be modified;- edit the value using the UP (12) or DOWN (10) buttons;- press DISPLAY button (14) again to confirm;- the display shows parameter 3CA again;- press the UP (12) or DOWN (10) buttons to go to the next parameter;- when parameter 3SA is on the display;- press DISPLAY button (14);- the display shows the value of the parameter to be modified;- edit the value using UP (12) or DOWN (10);- press DISPLAY button (14) again to confirm;- the display shows parameter 3SA again;- .............................REPEAT THE ABOVE STEPS FOR ALL THE PARAMETERS LISTED BELOW!!CYCLE CA3PARAMETER DESCRIPTION LIM - LIM + DEFAULT UM3CA Blast chilling stage 1 compart. Set-point -15 +25 -12 °C3SA Blast chilling stage 1 core probe set-point -15 +25 105 °C3iA Blast chilling stage 1 duration 1 240 60 Min3Cb Blast chilling stage 2 compart. Set-point -15 +25 0 °C3Sb Blast chilling stage 2 core probe set-point -15 +25 3 °C3ib Blast chilling stage 2 duration 0 240 30 MinCYCLE CC3 (BLAST CHILLER / SHOCK FREEZER ONLY)PARAMETER DESCRIPTION LIM - LIM + DEFAULT UM6CA Shock freeze stage 1 compart. Set-point -40 +25 -10 °C6SA Shock freeze stage 1 core probe set-point -40 +25 10 °C6iA Shock freeze stage 1 duration 1 240 60 Min6Cb Shock freeze stage 2 compart. Set-point -40 +25 -40 °C6Sb Shock freeze stage 2 core probe set-point -40 +25 -18 °C6ib Shock freeze stage 2 duration 0 240 180 MindSrTime for automatic selection of timer or coreprobe control mode1 10 3 min5.4 GERMICIDAL LAMP (optional)To activate the sterilization cycle:- check that the appliance is in STOP status;- press the UVC button (12).The sterilization cycle starts as soon as the UVC button is pressed <strong>and</strong> lasts for the time set by the manufacturer(20’) provided the door is closed <strong>and</strong> the compartment temperature is above 4° C.WARNING: sterilizing foodstuffs is not recommended; UV radiation is harmful, avoid exposing parts of the body toUV radiation.Clean the compartment thoroughly before carrying out the sterilization cycle. Do not obstruct the rayswith containers or tools placed in the vicinity of the lamp (only surfaces irradiated directly or indirectlywill be sterilized).23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!