enCare and Transportation• The <strong>VDW</strong>.GOLD ® RECIPROC ® ’s <strong>com</strong>ponentsare not delivered disinfected or sterilised:<strong>com</strong>ponents such as the central unit, themicromotor and the micromotor cable as wellas the lip clip and file clip cables must be disinfectedbefore the first use and after everyadditional use. The <strong>VDW</strong> 6:1 contra-angle,the lip clip and the file clip (without cables)must be sterilised before the first use andafter every additional use!• Never put the micromotor or other accessoryparts in an autoclave or an ultrasonicbath. Do not sterilise any <strong>VDW</strong>.GOLD ®RECIPROC ® <strong>com</strong>ponents (with the exceptionof the lip clip, the file clip (not includingcables) and the <strong>VDW</strong> 6:1 contra-angle). Seeseparate operating instructions on how tosterilise the <strong>VDW</strong> 6:1 contra-angle.• The plastic enclosure is not sealed. Donot use any liquids or sprays directly on theconsole, especially on the display or nearthe electrical sockets.Repair and Malfunctions• Do not use the <strong>VDW</strong>.GOLD ® RECIPROC ®if you suspect it is damaged or defective.• Repairing, changing or modifying the<strong>VDW</strong>.GOLD ® RECIPROC ® without the manufacturer’sprior approval is not permitted.<strong>VDW</strong> GmbH assumes no responsibility ifit has been changed or modified. Shoulda malfunction occur, contact your servicecentre instead of having repairs done by anunauthorized person.425. PrecautionsRead all safety information carefully before use.These precautionary measures help you use theproduct safely and thus prevent injury to bothyou and others. Keep this user’s manual in a safeplace for future reference. This manual must beincluded whenever the system is sold or passedon so that the new owner can observe these warningsand take the appropriate precautions.All special precautions to be taken before, duringand after operation can be found in Chapter 4Warnings. The manufacturer assumes no responsibilityin case of:• Use of the <strong>VDW</strong>.GOLD ® RECIPROC ® for purposesother than those specifically described in thismanual.• Performance of work or repairs by anyone notauthorized by the manufacturer or by the importerin the manufacturer’s name.• Use of non-original <strong>com</strong>ponents or <strong>com</strong>ponentsother than those described in Chapter 7.1 StandardComponents.• File breakage in the root canal during clinicaluse of the <strong>VDW</strong>.GOLD ® RECIPROC ® .• Connection of the micromotor to a power sourcewhich does not conform to IEC 364 norms.• Damage to device or accessories resulting fromsterilisation: <strong>VDW</strong>.GOLD ® RECIPROC ® <strong>com</strong>ponentscannot be sterilised (with the exception of the lipclip, the file clip (not including cables) and the <strong>VDW</strong>6:1 contra-angle. See also the separate operatinginstructions for information on sterilising the<strong>VDW</strong> 6:1 contra-angle.)Should you have any questions, please contactyour supplier or the <strong>VDW</strong> GmbH service centre.Disposal• Disposing of the <strong>VDW</strong>.GOLD ® RECIPROC ®in the normal household waste is not permitted.Dispose of the device in accordancewith Directive 2002/96/EEC regarding theseparate collection of electric/electronicdevices. For further details, please contact<strong>VDW</strong> GmbH directly.• For information on the proper disposalof the endodontic NiTi instruments, pleaserefer to the manufacturer’s instructions.These are not included in delivery.6. Adverse ReactionsThere are no known adverse reactions.7. Step-by-Step InstructionsThis chapter contains all necessary informationregarding the <strong>com</strong>missioning and operation of the<strong>VDW</strong>.GOLD ® RECIPROC ® .NOTEBefore using the device for the first time,familiarize yourself with Chapter 4 Warningswhich contains all special precautions to betaken before, during and after operation.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!