MODEL 2604 CONTROLLER - USER GUIDE - d a n m a r k
MODEL 2604 CONTROLLER - USER GUIDE - d a n m a r k MODEL 2604 CONTROLLER - USER GUIDE - d a n m a r k
Programmer Operation2604 ControllerIf PSP 2 is configured, steps 4 to 7 are repeated for PSP2.If PSP 3 is configured, steps 4 to 7 are again repeated for PSP3.If Wait Events are configured:-14. Press to select WaitEvent15. Press or to selectthe wait eventS:Wait EventvNo WaitThe choice are:-No WaitEvent AEvent BEventCSee also 6.6.4If Digital Event Outputs have been Configured:-16. Press to select PrgDO Values17. Press or toselect the digital outputevent to be On or OffS:Prg DO ValuesThe first digital output willalternate between andindicating that it can bechanged.= Off= On18. Press to scrollthrough each eventoutput in turnS:Prg DO Values19. Press to return toSegment Number20. Press or toselect the next requiredsegment and repeat theabove.S:Segment Numberv1J Tip:- To avoid scrolling through parameters you do not need to change, pressreturn to the page header, then to select Segment Number.to4-22 User Guide Part No HA026491 Issue 3.0 Apr-02
2604 Controller Programmer Operation4.9.2. Prog Data Entry Example - Time to Target ProgrammerThis is the same as the previous procedure except that there are no Dwell, Rate or Stepsegments. They are all Time segments.From the PROGRAM EDIT (segment Page) header:-Do This1. Press to selectSegment Number2. Press or toselect the segmentThis Is The Display YouShould SeeS:Segment Numberv1Additional Notes3. Press to selectSegment Type4. Press or toselect Profile5. Press to select PSP1Target6. Press or to setthe start level of thesegment (if necessary)7. Press to select SegDuration8. Press or to setthe segment timeS:Segment TypevProfileS:PSP1 Targetv40S:Seg Durationv0:01:00The choices are :-ProfileEnd SegmentGo Back for segmentsafter the firstFor any segment ž 1, thisvalue will normally beinherited from the Targetlevel of the previoussegment.The setpoint will ramp to40 at the rate of 1 unit persec, min or hourAs in the previousexample, if PSP2, PSP3,Wait Events and EventOutputs have beenconfigured they willappear here.9. Press as many timesas necessary to selectSegment Number again10. Press or toselect the next segment (2)and repeat the above.S:Segment Numberv2For a ramp PSP1 - SegNo. 1& PSP1 - Seg No. 2will be different values.For a dwell PSP1 Seg No.1& PSP1 - Seg No. 2 willbe the same value.J Tip:- To avoid scrolling through parameters you do not need to change, pressreturn to the page header, then to select Segment Number.toUser Guide. Part No HA026491 Issue 3.0 Apr-02 4-23
- Page 29 and 30: 2604 Controller InstallationRS485 2
- Page 31 and 32: 2604 Controller InstallationI/O Mod
- Page 33 and 34: 2604 Controller InstallationI/O Mod
- Page 35 and 36: 2604 Controller InstallationTransdu
- Page 37 and 38: 2604 Controller Installation2.5.1.
- Page 39 and 40: 2604 Controller Operation3. CHAPTER
- Page 41 and 42: 2604 Controller Operation3.1. POWER
- Page 43 and 44: 2604 Controller Operation3.3. THE A
- Page 45 and 46: 2604 Controller Operation3.5.1. To
- Page 47 and 48: 2604 Controller Operation3.6.2. To
- Page 49 and 50: 2604 Controller Operation3.6.5. To
- Page 51 and 52: 2604 Controller Operation3.6.6. Par
- Page 53 and 54: 2604 Controller Operation3.7.1. Loo
- Page 55 and 56: 2604 Controller Operation3.12. PARA
- Page 57 and 58: 2604 Controller Programmer Operatio
- Page 59 and 60: 2604 Controller Programmer Operatio
- Page 61 and 62: 2604 Controller Programmer Operatio
- Page 63 and 64: 2604 Controller Programmer Operatio
- Page 65 and 66: 2604 Controller Programmer Operatio
- Page 67 and 68: 2604 Controller Programmer Operatio
- Page 69 and 70: 2604 Controller Programmer Operatio
- Page 71 and 72: 2604 Controller Programmer Operatio
- Page 73 and 74: 2604 Controller Programmer Operatio
- Page 75 and 76: 2604 Controller Programmer Operatio
- Page 77: 2604 Controller Programmer Operatio
- Page 81 and 82: 2604 Controller Programmer Operatio
- Page 83 and 84: 2604 Controller Programmer Operatio
- Page 85 and 86: 2604 Controller Alarm Operation5. C
- Page 87 and 88: 2604 Controller Alarm Operation5.2.
- Page 89 and 90: 2604 Controller Alarm Operation5.3.
- Page 91 and 92: 2604 Controller Alarm Operation5.4.
- Page 93 and 94: 2604 Controller Alarm Operation5.5.
- Page 95 and 96: 2604 Controller Alarm Operation5.6.
- Page 97 and 98: 2604 Controller Alarm Operation5.7.
- Page 99 and 100: 2604 Controller Appendix AA. APPEND
- Page 101 and 102: 2604 Controller Appendix AA.2. CONF
- Page 103 and 104: 2604 Controller Safety and EMC Info
- Page 105 and 106: 2604 Controller Safety and EMC Info
- Page 107 and 108: 2604 Controller Safety and EMC Info
- Page 109 and 110: 2604 Controller Technical Specifica
- Page 111 and 112: 2604 Controller Technical Specifica
- Page 113 and 114: 2604 Controller Technical Specifica
- Page 115 and 116: 2604 Controller Technical Specifica
- Page 117 and 118: 2604 Controller Technical Specifica
- Page 119 and 120: 2604 Controller Technical Specifica
- Page 121 and 122: 2604 Controller Technical Specifica
<strong>2604</strong> Controller Programmer Operation4.9.2. Prog Data Entry Example - Time to Target ProgrammerThis is the same as the previous procedure except that there are no Dwell, Rate or Stepsegments. They are all Time segments.From the PROGRAM EDIT (segment Page) header:-Do This1. Press to selectSegment Number2. Press or toselect the segmentThis Is The Display YouShould SeeS:Segment Numberv1Additional Notes3. Press to selectSegment Type4. Press or toselect Profile5. Press to select PSP1Target6. Press or to setthe start level of thesegment (if necessary)7. Press to select SegDuration8. Press or to setthe segment timeS:Segment TypevProfileS:PSP1 Targetv40S:Seg Durationv0:01:00The choices are :-ProfileEnd SegmentGo Back for segmentsafter the firstFor any segment ž 1, thisvalue will normally beinherited from the Targetlevel of the previoussegment.The setpoint will ramp to40 at the rate of 1 unit persec, min or hourAs in the previousexample, if PSP2, PSP3,Wait Events and EventOutputs have beenconfigured they willappear here.9. Press as many timesas necessary to selectSegment Number again10. Press or toselect the next segment (2)and repeat the above.S:Segment Numberv2For a ramp PSP1 - SegNo. 1& PSP1 - Seg No. 2will be different values.For a dwell PSP1 Seg No.1& PSP1 - Seg No. 2 willbe the same value.J Tip:- To avoid scrolling through parameters you do not need to change, pressreturn to the page header, then to select Segment Number.toUser Guide. Part No HA026491 Issue 3.0 Apr-02 4-23