Technical Specification<strong>2604</strong> ControllerC.22.4.RTD (Pt-100) Input typeResistance measurement specification in Ohms:Range0 to 400Ω with up to 22Ωin each connecting leadNoise (resolution)8mΩ - 0.4sec,4mΩ - 1.6secCalibration accuracy limits @ 25 O C< + (35mΩ @110Ω + 0.03% of |reading - 110Ω|)Drift with ambient temperature+ (0.002% of |reading|) per o CLinearity error< +15 mΩPt-100 measurement specification in o C:Range-200 o C to +850 o CNoise (resolution)0.02 o C - 0.4sec, 0.01 o C - 1.6secCalibration accuracy limit @ 25 O C< + (0.1 o C + 0.03% of |reading in o C|)Drift with ambient temperature< +(0.0055 o C + 0.002% of |reading in o C|) per o C of ambient changeLinearity + Linearisation error< + 55 o mC (i.e. 50 o mC + 5 o mC )C-12 User Guide. Part No HA026491 Issue 3.0 Apr-02