Technical Specification2604 ControllerC.4.ANALOGUE INPUTNo of inputs One fixed (Not isolated)Can be used with either floating or ground referenced transducers oflow impedance.Input range -10V to +10V linear or 0 -20 mA with burden resistor of 100W.Calibration: ±(1.5mV + 0.1% of reading)Resolution: 0.9mVDrift: < ±(0.1mV + 0.006% of reading) per °CInput Impedance: 0.46MΩ (floating input), 0.23MΩ (groundreferenced input)IsolationNot isolated from standard digital I/O . Differential type input withcommon mode range of + 42Vdc (the average voltage of the two inputswith respect to ‘Screen’ or ‘Common’ terminals should be within+42Vdc.CMRR : >110dB at 50/60Hz, >80dB at DCFunctionsProcess variable, remote setpoint, power limit, feedforward, etc.C.5.ANALOGUE INPUT MODULEAllocation Up to 4 analogue input modules can be fitted in I/O slots 1,3,4 & 6mV input100mV range - used for thermocouple, linear mV source, or 0-20mAwith 2.49Ω external burden resistor.Calibration: + 10µV + 0.2% of readingResolution: 6µVDrift: < + 0.2µV + 0.004% of reading per O CInput impedance: >10MΩ, Leakage: 10MΩ, Leakage: 69KΩPt100 input 0 to 400ohms (-200°C to +850°C), 3 matched wires - up to 22W ineach lead without errors.Calibration: ±(0.4°C + 0.15% of reading in °C)Resolution: 0.08°CDrift: < ±(0.015°C + 0.005% of reading in °C) per °CBulb current: 0.3mA.Thermocouple Internal compensation: CJC rejection ratio >25:1 typical.CJ Temperature calibration error at 25 O C:
2604 Controller Technical SpecificationC.6.Allocationnot isolatedDigital inputsDigital outputsSTANDARD DIGITAL I/O1 digital input standard and 7 I/O which can be configured as inputs oroutputs plus 1 changeover relayVoltage level : input active < 2Vdc, inactive >4VdcContact closure : input active 28kohmsOpen collector, 24Vdc at 40mA drive capability, requires externalsupplyContact rating 2A at 264Vac resistiveChangeover relayFunctions Refer to Chapter 17Operations 1,000,000 operations with addition of external snubberC.7.DIGITAL INPUT MODULESModule type Triple contact input, Triple logic inputAllocation Can be fitted into slots 1, 3, 4, 5 or 6Contact closure Active 28kohmsLogic inputs Current sinking : active 10.8Vdc to 30Vdc at 2.5mAinactive -3 to 5Vdc at
- Page 61 and 62: 2604 Controller Programmer Operatio
- Page 63 and 64: 2604 Controller Programmer Operatio
- Page 65 and 66: 2604 Controller Programmer Operatio
- Page 67 and 68: 2604 Controller Programmer Operatio
- Page 69 and 70: 2604 Controller Programmer Operatio
- Page 71 and 72: 2604 Controller Programmer Operatio
- Page 73 and 74: 2604 Controller Programmer Operatio
- Page 75 and 76: 2604 Controller Programmer Operatio
- Page 77 and 78: 2604 Controller Programmer Operatio
- Page 79 and 80: 2604 Controller Programmer Operatio
- Page 81 and 82: 2604 Controller Programmer Operatio
- Page 83 and 84: 2604 Controller Programmer Operatio
- Page 85 and 86: 2604 Controller Alarm Operation5. C
- Page 87 and 88: 2604 Controller Alarm Operation5.2.
- Page 89 and 90: 2604 Controller Alarm Operation5.3.
- Page 91 and 92: 2604 Controller Alarm Operation5.4.
- Page 93 and 94: 2604 Controller Alarm Operation5.5.
- Page 95 and 96: 2604 Controller Alarm Operation5.6.
- Page 97 and 98: 2604 Controller Alarm Operation5.7.
- Page 99 and 100: 2604 Controller Appendix AA. APPEND
- Page 101 and 102: 2604 Controller Appendix AA.2. CONF
- Page 103 and 104: 2604 Controller Safety and EMC Info
- Page 105 and 106: 2604 Controller Safety and EMC Info
- Page 107 and 108: 2604 Controller Safety and EMC Info
- Page 109 and 110: 2604 Controller Technical Specifica
- Page 111: 2604 Controller Technical Specifica
- Page 115 and 116: 2604 Controller Technical Specifica
- Page 117 and 118: 2604 Controller Technical Specifica
- Page 119 and 120: 2604 Controller Technical Specifica
- Page 121 and 122: 2604 Controller Technical Specifica
Technical Specification<strong>2604</strong> ControllerC.4.ANALOGUE INPUTNo of inputs One fixed (Not isolated)Can be used with either floating or ground referenced transducers oflow impedance.Input range -10V to +10V linear or 0 -20 mA with burden resistor of 100W.Calibration: ±(1.5mV + 0.1% of reading)Resolution: 0.9mVDrift: < ±(0.1mV + 0.006% of reading) per °CInput Impedance: 0.46MΩ (floating input), 0.23MΩ (groundreferenced input)IsolationNot isolated from standard digital I/O . Differential type input withcommon mode range of + 42Vdc (the average voltage of the two inputswith respect to ‘Screen’ or ‘Common’ terminals should be within+42Vdc.CMRR : >110dB at 50/60Hz, >80dB at DCFunctionsProcess variable, remote setpoint, power limit, feedforward, etc.C.5.ANALOGUE INPUT MODULEAllocation Up to 4 analogue input modules can be fitted in I/O slots 1,3,4 & 6mV input100mV range - used for thermocouple, linear mV source, or 0-20mAwith 2.49Ω external burden resistor.Calibration: + 10µV + 0.2% of readingResolution: 6µVDrift: < + 0.2µV + 0.004% of reading per O CInput impedance: >10MΩ, Leakage: 10MΩ, Leakage: 69KΩPt100 input 0 to 400ohms (-200°C to +850°C), 3 matched wires - up to 22W ineach lead without errors.Calibration: ±(0.4°C + 0.15% of reading in °C)Resolution: 0.08°CDrift: < ±(0.015°C + 0.005% of reading in °C) per °CBulb current: 0.3mA.Thermocouple Internal compensation: CJC rejection ratio >25:1 typical.CJ Temperature calibration error at 25 O C: