Introduction2604 Controller1.4. INSTALLATION - OVERVIEWThe 2604 controller must be mounted and wired in accordance with the instructions given inChapter 2.The controller is intended to be mounted through a cut out in the front panel of an electricalcontrol cabinet. It is retained in position using the panel mounting clips supplied.All wires are connected to terminals at the rear of the instrument. Each block of six terminalsis protected by a hinged cover which clicks into closed position.DigitalI/OPVinputDCD1D2D3D4D5D6D7VHVIV+V-MODULE4MODULE5MODULE64A4B4C4D5A5B5C5D6A6B6C6DMODULE1****MODULE31A1B1C1D2A2B2C2D3A3B3C3DCOMMSMODULEHCOMMSMODULEJHAHBHCHDHEHFJAJBJCJDJEJFLND8E1E2AAABACBABBBCPowerSupplyDigitalInputI/OExpanderor DigitalinputRelayAnalogueinput0-10VAnalogueinputscreenThe functionality of the two outer rows of terminals iscommon to all instrument variants, as follows:-PV input VH, VI, V+, V-Analogue inputBA, BBI/O expanderE1, E2Fixed changeover relay AA, AB, ACDigital I/O channels D1 to D8 and DCPower supplyL, N, Earth* Terminals 2A, 2B, 2C, 2D must not be wired to.Hingedcover inopenpositionFigure 1-5: Rear Terminals1-8 User Guide Part No HA026491 Issue 3.0 Apr-02
2604 Controller Introduction1.5. I/O MODULESThe 2604 controller has the facility to fit optional plug in modules. The connections for thesemodules are made to the inner three connector blocks as shown in Figure 1-6The modules are:• Communications modules See also section 2.4• I/O modules See also section 2.4These modules are fitted simply by sliding them into the relevant position as shown below.Figure 1-6: View of the Plug-in ModulesUser Guide Part No HA026491 Issue 3.0 Apr-02 1-9
- Page 1 and 2: 2604 Controller ContentsMODEL 2604
- Page 3 and 4: RESEARCHLETTERaReference beamHOEabO
- Page 5 and 6: 2604 Controller Introduction1.2. BE
- Page 9: 2604 Controller Introduction1.3.2.
- Page 17 and 18: 2604 Controller InstallationThe thr
- Page 19 and 20: 2604 Controller Installation2.3.2.
- Page 21 and 22: 2604 Controller Installation2.3.4.
- Page 23 and 24: 2604 Controller Installation2.3.6.
- Page 25: 2604 Controller InstallationRS485 4
- Page 29 and 30: 2604 Controller InstallationRS485 2
- Page 31 and 32: 2604 Controller InstallationI/O Mod
- Page 33 and 34: 2604 Controller InstallationI/O Mod
- Page 35 and 36: 2604 Controller InstallationTransdu
- Page 37 and 38: 2604 Controller Installation2.5.1.
- Page 39 and 40: 2604 Controller Operation3. CHAPTER
- Page 41 and 42: 2604 Controller Operation3.1. POWER
- Page 43 and 44: 2604 Controller Operation3.3. THE A
- Page 45 and 46: 2604 Controller Operation3.5.1. To
- Page 47 and 48: 2604 Controller Operation3.6.2. To
- Page 49 and 50: 2604 Controller Operation3.6.5. To
- Page 51 and 52: 2604 Controller Operation3.6.6. Par
- Page 53 and 54: 2604 Controller Operation3.7.1. Loo
- Page 55 and 56: 2604 Controller Operation3.12. PARA
- Page 57 and 58: 2604 Controller Programmer Operatio
- Page 59 and 60: 2604 Controller Programmer Operatio
Introduction<strong>2604</strong> Controller1.4. INSTALLATION - OVERVIEWThe <strong>2604</strong> controller must be mounted and wired in accordance with the instructions given inChapter 2.The controller is intended to be mounted through a cut out in the front panel of an electricalcontrol cabinet. It is retained in position using the panel mounting clips supplied.All wires are connected to terminals at the rear of the instrument. Each block of six terminalsis protected by a hinged cover which clicks into closed position.DigitalI/OPVinputDCD1D2D3D4D5D6D7VHVIV+V-MODULE4MODULE5MODULE64A4B4C4D5A5B5C5D6A6B6C6DMODULE1****MODULE31A1B1C1D2A2B2C2D3A3B3C3DCOMMSMODULEHCOMMSMODULEJHAHBHCHDHEHFJAJBJCJDJEJFLND8E1E2AAABACBABBBCPowerSupplyDigitalInputI/OExpanderor DigitalinputRelayAnalogueinput0-10VAnalogueinputscreenThe functionality of the two outer rows of terminals iscommon to all instrument variants, as follows:-PV input VH, VI, V+, V-Analogue inputBA, BBI/O expanderE1, E2Fixed changeover relay AA, AB, ACDigital I/O channels D1 to D8 and DCPower supplyL, N, Earth* Terminals 2A, 2B, 2C, 2D must not be wired to.Hingedcover inopenpositionFigure 1-5: Rear Terminals1-8 User Guide Part No HA026491 Issue 3.0 Apr-02