procedure & prodotti<br />

<strong>NOBELSPEEDY</strong> <br />

Groovy<br />

Shorty


Novità assoluta da <strong>Nobel</strong> <strong>Biocare</strong>.<br />

Impianti NOBELPERFECT ® (NP, RP, WP), NOBELDIRECT ® (NP, RP, WP), Brånemark System ® , NOBELREPLACE e <strong>NOBELSPEEDY</strong> ,<br />

Un assortimento completo con approvazione dell’FDA (Food and Drug Administration) per Immediate<br />

Function in tutte le indicazioni: monoedentulia; edentulismi parziale e totale, in entrambe le arcate.<br />

<strong>Nobel</strong> <strong>Biocare</strong> AB e tutte le unità di produzione sono certificati in conformità<br />

all’Environmental Management System ISO 14001.<br />

Alcuni prodotti possono non essere disponibili in tutti i mercati. Rivolgersi all’ufficio locale<br />

di <strong>Nobel</strong> <strong>Biocare</strong> per informazioni sulla gamma dei prodotti esistente e la loro disponibilità.<br />

<strong>Nobel</strong> <strong>Biocare</strong> è conforme alle direttive<br />

ISO 13485:1996, alla Direttiva del Consiglio Europeo 93/42/EEC<br />

e alla Canadian Medical Devices Regulation.<br />

0086<br />

Solo per USA: le leggi federali limitano la vendita di questo dispositivo a o per ordine di un odontoiatra o di un medico specializzato.<br />

Tutti i prodotti sono soggetti a modifiche senza preavviso.


guida rapida – <strong>NOBELSPEEDY</strong> <br />

Groovy<br />

Congratulazioni! Avete fatto un’ottima scelta. Benvenuti nella famiglia<br />

<strong>Nobel</strong> <strong>Biocare</strong>.<br />

Prodotti necessari per il posizionamento dell’impianto:<br />

• Brånemark System ® Surgery Kit (kit chirurgico Brånemark<br />

System ® ), include gli strumenti per gli impianti RP<br />

• <strong>Nobel</strong> <strong>Biocare</strong> Flapless Surgery Kit<br />

(kit chirurgico <strong>Nobel</strong> <strong>Biocare</strong> Flapless)<br />

• Impianti:<br />

– <strong>Nobel</strong>Speedy Groovy<br />

– <strong>Nobel</strong>Speedy Shorty<br />

• Frese monouso<br />

Brånemark System ® Surgery Kit<br />

(kit chirurgico Brånemark System ® )<br />

<strong>Nobel</strong> <strong>Biocare</strong> Flapless<br />

Surgical Kit (kit chirurgico<br />

<strong>Nobel</strong> <strong>Biocare</strong> Flapless)<br />

Prodotti necessari per provvisori/Immediate Function <br />

Protesi di dente singolo preparate in studio<br />

• Temporary Immediate Abutment Brånemark System ® , NP, RP, WP<br />

(abutment provvisorio immediato Brånemark System ® )<br />

• Kit protesico<br />

Protesi multiple preparate in studio<br />

• Temporary Abutment Non-Engaging Brånemark System ® , NP, RP, WP<br />

(abutment provvisori non-antirotazionali Brånemark System ® )<br />

• Kit protesico<br />

Protesi preparate in laboratorio<br />

• Impression Coping Implant Level Brånemark System ® , NP, RP, WP<br />

(transfer di impronta a livello dell’impianto Brånemark System ® )<br />

• Healing Abutment Brånemark System ®<br />

(abutment di guarigione Brånemark System ® )<br />

• Abutment adattati dal laboratorio odontotecnico<br />

– Esthetic Abutment Brånemark System ®<br />

– Temporary Abutment Brånemark System ®<br />

(abutment provvisorio Brånemark System ® )<br />

3


tecnica senza lembo<br />

Drill Guide/Twist Drill w Tip<br />

∅ 2 mm (Guida della fresa/<br />

Twist Drill con punta)<br />

Tissue Punch/<br />

Tissue Punch Guide<br />

(Bisturi circolare/Guida<br />

del bisturi circolare<br />

Vedere la tabella nell’ultima<br />

pagina della Guida rapida per le<br />

sequenze delle frese per tutte le<br />

piattaforme e i diversi tipi di osso.<br />

Twist Drill w Tip ∅ 2 mm<br />

(Twist Drill con punta)<br />

Twist Step Drill<br />

∅ 2,4/2,8 mm<br />

tecnica con lembo<br />

4


Funzionalità differita<br />

in una fase<br />

Posizionamento dell’impianto<br />

Immediate Function <br />

in una fase<br />

Funzionalità differita in due fasi<br />

5


linea di riferimento dei prodotti<br />

Frese occorrenti<br />

Si raccomanda di adottare la seguente sequenza di fresaggio per assicurare una stabilità<br />

primaria ottimale dell’impianto quando si applica Immediate Function .<br />

Platform<br />

Implant ∅<br />

Drill Sequence (according too bone quality)<br />

Soft bone Medium bone Dense bone<br />

NP 3,3 ∅ 2,0 ∅ 2,0 ∅ 2,0<br />

∅ 2,4/2,8<br />

RP 4,0 ∅ 2,0<br />

(∅ 2,4/2,8)<br />

WP 5,0 ∅ 2,0<br />

∅ 2,4/2,8<br />

∅ 3,0<br />

WP 6,0 ∅ 2,0<br />

∅ 2,4/2,8<br />

∅ 3,2/3,6<br />

∅ 2,0<br />

∅ 2,4/2,8<br />

∅ 3,2<br />

∅ 2,0<br />

∅ 2,4/2,8<br />

∅ 3,2/3,6<br />

∅ 2,0<br />

∅ 2,4/2,8<br />

∅ 3,2/3,6<br />

∅ 3,8/4,2<br />

∅ 2,0<br />

∅ 2,4/2,8<br />

∅ 3,4<br />

∅ 2,0<br />

∅ 2,4/2,8<br />

∅ 3,2/3,6<br />

∅ 3,8/4,2<br />

∅ 2,0<br />

∅ 2,4/2,8<br />

∅ 3,2/3,6<br />

∅ 3,8/4,2<br />

∅ 5,0<br />

Note: tutte le misure sono espresse in mm.<br />

Le frese tra parentesi () denotano solamente l’allargamento della corticale marginale.<br />

Per gli impianti NP in osso estremamente morbido, è anche disponibile una Twist Drill da 1,5 mm.<br />

Sistema di misurazione della profondità<br />

Tutte le frese e i componenti sono contrassegnati in modo da permettere<br />

di preparare il sito implantare alla profondità corretta e di<br />

ottenere un posizionamento saldo e prevedibile dell’impianto.<br />

Nota: le tacche sulle frese (7, 10,13,15 and 18 mm) indicano<br />

lunghezze effettive in millimetri corrispondenti alla sommità del colletto<br />

dell’impianto.<br />

Il posizionamento verticale finale dipende da diversi parametri clinici,<br />

tra cui:<br />

• Estetica<br />

• Spessore tissutale<br />

• Altezza verticale disponibile<br />

La preparazione della fresa è 1 mm più lunga dell’impianto, quindi,<br />

durante il fresaggio in prossimità di strutture anatomiche vitali,<br />

occorre tenere conto di tale maggiore lunghezza.<br />

6


indice<br />

Beautiful Teeth Now .......................................................................................8<br />

<strong>NOBELSPEEDY</strong> Groovy ........................................................................................9<br />

Procedura chirurgica<br />

Con o senza lembo .......................................................................................10<br />

Sequenza di fresaggio ...................................................................................12<br />

Posizionamento dell’impianto .......................................................................15<br />

Procedure di finalizzazione ...........................................................................16<br />

Soluzioni di finalizzazione raccomandate ...................................................21<br />

Considerazioni preoperatorie<br />

Immediate Function ....................................................................................22<br />

Posizionamento dell’impianto al momento dell’estrazione del dente .............23<br />

Mascherine radiografiche ..............................................................................23<br />

Appendici<br />

Appendice I – Kit. ..........................................................................................24<br />

Appendice II – Manual Torque Wrench chirurgico/protesico. .........................26<br />

Appendice III – Utilizzo degli osteotomi. ........................................................27<br />

Appendice IV – Utilizzo del Drill Stop ............................................................28<br />

Appendice V – Pulizia e sterilizzazione ...........................................................29<br />

Diagramma di flusso ......................................................................................30<br />

Catalogo prodotti. ..........................................................................................34<br />

Elenco prodotti ...............................................................................................38<br />

7


eautiful teeth now <br />

Oggi <strong>Nobel</strong> <strong>Biocare</strong> è in grado di offrire ai dentisti una scelta ancora<br />

più ampia ma sempre con gli stessi obiettivi:<br />

• Assicurare che i vostri pazienti lascino il vostro studio<br />

soddisfatti, a proprio agio, con denti di aspetto gradevole<br />

e una rinnovata qualità della vita.<br />

• Aiutare a rendere la vostra pratica professionale più<br />

efficiente, quindi più redditizia.<br />

Questo manuale è progettato per fornire un accesso<br />

immediato a informazioni importanti su trattamenti,<br />

procedure e opzioni riguardanti la soluzione basata su<br />

sistemi implantari <strong>Nobel</strong>Speedy Groovy.<br />

Le soluzioni <strong>Nobel</strong> <strong>Biocare</strong> sono progettate per agevolare:<br />

• Immediate Function <br />

• Estetica di facile impiego a breve e lungo termine<br />

• Comfort del paziente<br />

... e possono essere impiegate anche nell’innovativo metodo<br />

di trattamento <strong>Nobel</strong>Guide di <strong>Nobel</strong> <strong>Biocare</strong>.<br />

Per ulteriori informazioni, vedere il manuale/CD <strong>Nobel</strong>Guide .<br />

La combinazione esclusiva di trama e<br />

porosità controllata dell’ossido di titanio<br />

consente all’osso di crescere direttamente<br />

sulla superficie e al suo interno.<br />

(Per gentile concessione del Dott. Peter<br />

Schüpbach, Svizzera.)<br />

Per gli abstract, i riferimenti bibliografici sugli studi e ulteriori informazioni, visitare<br />

il nostro sito Web: www.nobelbiocare.com<br />

8


<strong>NOBELSPEEDY</strong> <br />

Groovy<br />

• È l’impianto autofilettante universale che può essere utilizzato<br />

per il trattamento di tutte le indicazioni in cui il volume dell’osso<br />

disponibile sia appropriato per un impianto.<br />

Diametro dell’impianto<br />

• Impianto in due pezzi con connessione dell’abutment esagonale<br />

esterno.<br />

• La configurazione parallela significa semplice posizionamento e<br />

la versatilità assicura, virtualmente, la possibilità di trattamento di<br />

tutti i casi.<br />

Lunghezza<br />

dell’impianto<br />

• L’apice dell’impianto ha quattro camere di taglio e un diametro<br />

inferiore per facilitare il posizionamento in preparazioni di diametro<br />

ridotto, estendendo quindi le indicazioni di Immediate<br />

Function .<br />

Piattaforma<br />

Per facilitare la pianificazione del trattamento, le procedure cliniche e l’identificazione<br />

dei componenti, gli impianti <strong>Nobel</strong>Speedy Groovy sono organizzati<br />

secondo un “concetto di piattaforma”. La piattaforma corrisponde all’interfaccia<br />

impianto-abutment.<br />

Piattaforma Diametro Diametro Lunghezze<br />

piattaforma impianto<br />

∅ 3,5 ∅ 3,3 – 10 11,5 13 15 –<br />

Narrow Platform: spazio interdentale limitato. Volume di osso alveolare insufficiente per un impianto RP.<br />

∅ 4,1 ∅ 4,0 8,5 10 11,5 13 15 18<br />

Regular Platform: dalla perdita di un dente singolo anteriore alla ricostruzione di tutta l’arcata.<br />

∅ 5,1<br />

∅ 5,0 8,5 10 11,5 13 15 18<br />

∅ 6,0 8,5 10 11,5 13 15 18<br />

Wide Platform: nei casi in cui si prevede un carico addizionale. Un impianto/abutment di maggiore<br />

diametro per protesizzare corone di “dimensione molare”. Per ottenere una maggiore stabilità iniziale<br />

nell’osso morbido.<br />

<strong>NOBELSPEEDY</strong> Shorty<br />

• Versione 7 mm di <strong>Nobel</strong>Speedy Groovy.<br />

• Disponibile nelle piattaforme e diametri dell’impianto seguenti:<br />

Platform<br />

Lunghezza<br />

dell’impianto<br />

Implant diameter ∅ 4,0 ∅ 5,0 ∅ 6,0<br />

Nota: tutte le dimensioni sono espresse in millimetri.<br />

9


procedura chirurgica<br />

Utilizzare la tecnica senza lembo quando:<br />

• La qualità e la quantità di osso alveolare e di tessuto molle<br />

sono sufficienti.<br />

• Non è necessario procedere al sollevamento del lembo per<br />

indirizzare in modo sicuro la procedura di fresaggio in relazione<br />

all’anatomia.<br />

Utilizzare la tecnica con lembo quando:<br />

• È necessario osservare l’osso alveolare sottostante e le strutture<br />

anatomiche adiacenti.<br />

• Si esegue un innesto di osso e/o degli innesti di tessuto connettivo.<br />

Importante: confermare la quantità di osso disponibile e i punti<br />

di riferimento anatomici significativi, come vasi sanguigni, nervi e<br />

concavità, con strumenti diagnostici convenzionali, come radiografie,<br />

sondaggio e palpazione.<br />

Senza lembo<br />

Con lembo<br />

10


procedura chirurgica<br />

Posizionamento dell’impianto<br />

• Praticare il foro attraverso il tessuto gengivale e nella cresta<br />

alveolare con la Drill w Tip Tapered ∅ 2 mm (fresa con<br />

punta Tapered).<br />

• Utilizzare la Drill Guide (guida della fresa) come ausilio per<br />

il posizionamento corretto.<br />

• Forare fino alla linea di 15 mm indicata sulla fresa (misurata<br />

alla sommità della guida per fresa), per impianti di qualsiasi<br />

lunghezza, tranne 7 e 8,5 mm. Per gli impianti da 7 e 8,5<br />

mm, forare fino alla linea di 13 mm indicata sulla fresa.<br />

15<br />

13<br />

10<br />

7<br />

Senza lembo<br />

5 mm<br />

Alta velocità<br />

2000 giri/min<br />

Tissue Punch (bisturi circolare)<br />

Senza lembo<br />

• Inserire la Tissue Punch Guide (guida per bisturi circolare)<br />

delle dimensioni appropriate nel foro pilota ∅ 2 mm.<br />

• Connettere il Tissue Punch (bisturi circolare) al manipolo<br />

contrangolo e sistemare il bisturi sulla guida.<br />

8,5 mm<br />

• Ad alta velocità, incidere i tessuti molli fino alla cresta.<br />

Alta velocità<br />

800 giri/min<br />

Opercolo di tessuto/incisione<br />

• Con un bisturi, incidere intorno all’opercolo di tessuto in<br />

direzione perpendicolare rispetto alla cresta alveolare, per<br />

liberarlo da quest’ultima.<br />

• Per una procedura con lembo, come operazione preliminare<br />

praticare un’incisione adeguata per sollevare il lembo.<br />

Senza lembo<br />

Senza lem-<br />

Con lembo<br />

11


Senza lemprocedura<br />

chirurgica<br />

Le frese sono in acciaio chirurgico, ricoperte da uno strato di<br />

diamante amorfo che attribuisce loro il caratteristico colore<br />

nero. Le frese vengono utilizzate con irrigazione esterna.<br />

• Effettuare un movimento continuo “dentro e fuori” e fresare<br />

nell’osso per 1-2 secondi.<br />

• Sollevare la fresa senza fermare il motore per consentire all’irrigazione<br />

di rimuovere i frammenti di osso.<br />

• Continuare con questo metodo fino alla profondità adeguata<br />

in base alla qualità dell’osso e al diametro dell’impianto.<br />

15<br />

5<br />

13<br />

13<br />

10<br />

0<br />

7 17<br />

• Interrompere il fresaggio se non c’è l’irrigazione.<br />

• È necessario integrare l’irrigazione se si utilizza la prolunga<br />

per le frese. La prolunga per le frese deve essere utilizzata solo<br />

con le frese.<br />

Importante: la preparazione della fresa è 1 mm più lunga dell’impianto.<br />

Pertanto, durante il fresaggio in prossimità di strutture<br />

anatomiche vitali, occorre tenere conto della maggiore lunghezza.<br />

Senza lembo<br />

Nota: i maschiatori, le Twist Drill e le Twist Step Drill sono monouso<br />

e devono essere utilizzate per un solo intervento chirurgico.<br />

Non risterilizzare una fresa monouso.<br />

Con lembo<br />

Twist Drill with Tip ∅ 2 mm (Twist Drill con punta)<br />

• Fresare fino alla profondità appropriata usando la Twist Drill<br />

w Tip ∅ 2 mm (Twist Drill con punta).<br />

Nota: quando si esegue una procedura senza lembo, misurare lo<br />

spessore con una sonda. Aggiungere lo spessore tissutale alla profondità<br />

di fresaggio per la corretta preparazione del sito. Prestare<br />

attenzione ai punti di riferimento anatomici.<br />

• Controllare l’orientamento utilizzando un Direction Indicator<br />

∅ 2,0/2,4–2,8 mm (indicatore di direzione).<br />

• Durante il posizionamento di impianti multipli procedere alla<br />

preparazione del sito seguente prima di passare alla sequenza<br />

di fresaggio successiva.<br />

Alta velocità<br />

2000 giri/min<br />

Senza lembo<br />

Con lembo<br />

Questo è il passaggio finale di preparazione per: - impianti NP<br />

in osso morbido e medio<br />

Passare a “Determinare la lunghezza dell’impianto”<br />

Le illustrazioni mostrano la sequenza di fresaggio per <strong>Nobel</strong>Speedy <br />

Groovy RP 4,0 x 13 mm<br />

12


procedura chirurgica<br />

Twist Step Drill ∅ 2.4/2.8 mm<br />

• Proseguire la preparazione del sito usando una Twist Step<br />

Drill ∅ 2,4/2,8 mm<br />

• Controllare l’orientamento utilizzando un Direction Indicator<br />

∅ 2,0/2,4–2,8 mm (indicatore di direzione).<br />

Alta velocità<br />

2000 giri/min<br />

Senza lembo<br />

Senza lem-<br />

Con lembo<br />

Questo è il passaggio finale di preparazione per: – impianti NP<br />

in osso denso - impianti RP in osso morbido Passare a “Determinare<br />

la lunghezza dell’impianto”<br />

Preparazione della Twist Drill (cont.)<br />

A seconda della lunghezza dell’impianto da posizionare, fresare<br />

fino alla profondità appropriata utilizzando:<br />

impianti RP ∅ 4,0 mm:<br />

– Twist Drill ∅ 3,2 mm per osso medio<br />

– Twist Drill ∅ 3,4 mm per osso denso<br />

Senza lembo<br />

Senza lem-<br />

Con lembo<br />

Alta velocità<br />

2000 giri/min<br />

Stabilire la lunghezza dell’impianto<br />

• Utilizzare il misuratore di profondità per determinare la<br />

lunghezza dell’impianto<br />

Senza lembo<br />

Con lembo<br />

Senza lem-<br />

Importante:fare riferimento alla tabella della sezione Guida rapida di<br />

questo manuale per un elenco delle sequenze di fresaggio con Twist<br />

Drill necessarie a seconda dell’impianto <strong>Nobel</strong>Speedy (piattaforma e<br />

diametro) da posizionare.<br />

13


procedura chirurgica<br />

Senza lembo<br />

Counterbore (svasatori)<br />

O<br />

P<br />

Z<br />

I<br />

O<br />

N<br />

A<br />

L<br />

E<br />

• Se necessario, utilizzare lo Brånemark System ® Counterbore<br />

(svasatore Brånemark System ® ) corrispondente per preparare<br />

il sito implantare ad accogliere la testa dell’impianto.<br />

Nota: occorre tenere conto della qualità dell’osso e dello spessore<br />

dello strato corticale marginale. Al fine di ottenere una corretta<br />

stabilità dell’impianto, lo svasatore dovrebbe rimanere entro l’osso<br />

corticale marginale, specialmente in situazioni con osso spongioso.<br />

Senza lem-<br />

Con lembo<br />

Alta velocità<br />

2000 giri/min<br />

O<br />

P<br />

Z<br />

I<br />

O<br />

N<br />

A<br />

L<br />

E<br />

Screw Taps (maschiatori)<br />

• La pre-maschiatura può essere necessaria nei casi di osso<br />

medio/denso. Selezionare il maschiatore corrispondente al<br />

diametro della Twist Drill finale.<br />

• Posizionare a bassa velocità (25 giri/min) il maschiatore nel<br />

sito implantare preparato.<br />

• Esercitando una decisa pressione, avviare la lenta rotazione<br />

del maschiatore. Una volta ingaggiata la filettatura, far procedere<br />

il maschiatore senza applicare alcuna pressione.<br />

Vedere le tacche di riferimento nella figura.<br />

Senza lembo<br />

Senza lem-<br />

Con lembo<br />

• Invertire la direzione del manipolo ed estrarre il maschiatore.<br />

Bassa velocità<br />

Max 45 Ncm<br />

Senza lembo<br />

O<br />

P<br />

Z<br />

I<br />

O<br />

N<br />

A<br />

L<br />

E<br />

Precision Drill (fresa di precisione)<br />

• Per agevolare la penetrazione nei tessuti molli e la creazione di<br />

una punto di partenza crestale, si può utilizzare una Precision<br />

Drill (fresa di precisione) prima della Twist Drill ∅ 2 mm.<br />

• Praticare il foro attraverso il tessuto gengivale e nella cresta<br />

alveolare con la Precision Drill (fresa di precisione).<br />

• Utilizzare la Drill Guide (guida della fresa) come ausilio per<br />

il posizionamento corretto.<br />

Senza lem-<br />

16<br />

13<br />

10<br />

8<br />

∅ 2<br />

Alta velocità<br />

2000 giri/min<br />

14


procedura chirurgica<br />

Posizionamento dell’impianto<br />

Le illustrazioni mostrano gli impianti RP. La stessa procedura si<br />

applica agli impianti NP e WP.<br />

Confezione<br />

• Ogni impianto è confezionato in un sistema a doppio contenitore<br />

sterile.<br />

• La confezione esterna ha un’etichetta stampata che riporta i<br />

dati del prodotto. Annotare le dimensioni dell’impianto e il<br />

numero di lotto sulla cartella del paziente.<br />

• Le due etichette rimovibili, presenti sul contenitore esterno, possono<br />

essere incollate direttamente sulla cartella.<br />

• La capsula del contenitore esterno dell’impianto è bianca.<br />

Un’etichetta contrassegna il diametro e la lunghezza dell’impianto.<br />

• Sul contenitore interno in titanio sono indicate la piattaforma e le<br />

dimensioni dell’impianto.<br />

• Togliere il cappuccio in plastica per accedere all’impianto. (Alla<br />

confezione dell’impianto non è acclusa alcuna vite di copertura)<br />

Prendere l’impianto<br />

• Aprire la confezione esterna (non sterile).<br />

• Estrarre il contenitore interno sterile che contiene l’impianto.<br />

• Connettere il Implant Driver Brånemark System ® (driver per<br />

impianto Brånemark System ® ) appropriato al manipolo.<br />

• Estrarre l’impianto esercitando una leggera pressione sul driver.<br />

Posizionamento dell’impianto<br />

• Installare l’impianto nell’osteotomia a bassa velocità (25 giri/min)<br />

e con il valore di torque appropriato, tra 20 e 45 Ncm.<br />

• Ruotare l’impianto finché non si posiziona completamente.<br />

• Allineare il driver all’impianto durante l’installazione.<br />

• Rimuovere il driver estraendolo con un semplice movimento<br />

verso l’alto.<br />

Bassa velocità<br />

Max 45 Ncm<br />

Regolazioni/serraggio manuali<br />

• Connettere Implant Driver Wrench Adapter Brånemark<br />

System ® (l’adattatore per chiave del driver per impianto<br />

Brånemark System ® ) al Brånemark System ® Manual Torque<br />

Wrench (Manual Torque Wrench chirurgico Brånemark<br />

System ® ) e posizionare l’impianto alla profondità finale.<br />

• Per Immediate Function , l’impianto dovrebbe essere in grado di<br />

sostenere un torque di serraggio finale di 35–45 Ncm.<br />

15


procedure di finalizzazione<br />

Esistono tre opzioni per la finalizzazione degli interventi di chirurgia implantare<br />

con impianti <strong>Nobel</strong>Speedy Groovy.<br />

Per una descrizione più dettagliata delle procedure protesiche e di laboratorio<br />

riguardanti gli impianti esaminati in questo manuale, consultare i manuali<br />

Procedura di Laboratorio e <strong>Nobel</strong>Esthetics di <strong>Nobel</strong> <strong>Biocare</strong>.<br />

Immediate Function <br />

in una fase<br />

Funzionalità differita<br />

in una fase<br />

Funzionalità differita<br />

in due fasi<br />

Inserire un provvisorio per ottenere<br />

un’estetica e una funzionalità<br />

immediate usando i<br />

componenti provvisori o gli<br />

abutment definitivi <strong>Nobel</strong> <strong>Biocare</strong><br />

(vedere le procedure<br />

seguenti).<br />

Utilizzare un Unigrip Screwdriver<br />

(cacciavite Unigrip ) per<br />

connettere l’Healing Abutment<br />

Brånemark System ® . Se applicabile,<br />

suturare il tessuto molle.<br />

Utilizzare un Cover Screw<br />

Driver Hexagon (cacciavite<br />

esagonale per vite di copertura)<br />

per connettere la Cover<br />

Screw Brånemark System ®<br />

(vite di copertura Brånemark<br />

System ® ). Suturare il lembo<br />

adottando la tecnica desiderata.<br />

16


procedure di finalizzazione<br />

Immediate Function – protesi di elemento<br />

singolo (procedura in studio)<br />

Immediate Temporary Abutment (abutment provvisorio<br />

immediato)<br />

• Posizionare un Immediate Temporary Abutment<br />

Brånemark System ® . Serrare a 35 Ncm con Manual Torque<br />

Wrench protesico e cacciavite meccanico Multi-Unit.<br />

Nota: Immediate Temporary Abutment Brånemark System ® è<br />

indicato solamente per protesi provvisorie di elemento singolo.<br />

Regolazione dell’abutment<br />

• Il perno dell’abutment viene adattato in altezza e all’interno<br />

dello spazio disponibile, in base alle esigenze.<br />

• La Plastic Coping (cappetta in plastica) (fornita con Immediate<br />

Temporary Abutment) viene inserita per prova e regolata<br />

all’interno dello spazio disponibile, in base alle esigenze.<br />

Fabbricazione dei provvisori<br />

• Fabbricare una corona provvisoria secondo i metodi tradizionali<br />

utilizzando resina acrilica o composita.<br />

Cementazione del provvisorio<br />

• Il cemento provvisorio in eccesso viene rimosso secondo le<br />

procedure standard. Controllare l’occlusione.<br />

17


procedure di finalizzazione<br />

Immediate Function – protesi multiple<br />

(procedura in studio)<br />

Temporary Abutment Non-Engaging (abutment provvisorio<br />

non-antirotazionale)<br />

• Posizionare e adattare i Temporary Abutment Non-Engaging<br />

Brånemark System ® in altezza e all’interno dello spazio<br />

disponibile, in base alle esigenze.<br />

• Fissare sugli abutment perni guida sporgenti oltre il piano<br />

occlusale usando un cacciavite Unigrip .<br />

Modello acrilico<br />

• Costruire un modello acrilico per realizzare il provvisorio in studio.<br />

• Praticare i fori di accesso per consentire ai perni guida di sporgere.<br />

• Riempire il modello con materiale acrilico o composito e metterlo<br />

in sede sugli abutment provvisori.<br />

Regolazione della protesi provvisoria<br />

• Dopo l’inserimento, allentare i perni guida per rimuovere la protesi.<br />

• Rifinire e lucidare. È importante avere una superficie liscia adiacente<br />

ai tessuti molli circostanti.<br />

Collegamento della protesi provvisoria<br />

• Collegare la ricostruzione provvisoria con le viti per abutment fornite.<br />

• Serrare a 35 Ncm utilizzando il Manual Torque Wrench con adattatore<br />

protesico e cacciavite meccanico Unigrip .<br />

• Controllare l’occlusione.<br />

18


procedure di finalizzazione<br />

Immediate Function – protesi preparate in laboratorio<br />

Inserimento del transfer d’impronta<br />

• Controllare che non vi siano frammenti ossei o di tessuto<br />

nell’interfaccia dell’impianto.<br />

• Posizionare il Impression Coping Closed Tray Brånemark<br />

System ® (transfer per impronta per cucchiaio chiuso<br />

Brånemark System ® ) sull’impianto.<br />

• Effettuare una radiografia per verificare che il transfer sia<br />

completamente inserito.<br />

Impronta<br />

• Inserire un materiale d’impronta (tipo polietere o polivinilsiloxano)<br />

intorno a ogni transfer d’impronta e nel cucchiaio.<br />

• Prendere l’impronta. Rimuovere l’impronta. Rimuovere il transfer<br />

d’impronta. Avvitare il transfer sul riproduttore dell’impianto corrispondente.<br />

• Inserire il transfer di impronta e il riproduttore dell’impianto nella<br />

posizione corrispondente dell’impronta e colare il modello.<br />

• Posizionare l’Healing Abutment Brånemark System ® finché non<br />

viene inserito un provvisorio.<br />

Fabbricazione dei provvisori<br />

• L’altezza, l’angolazione e il margine di un abutment definitivo<br />

o provvisorio vengono regolati nel laboratorio odontotecnico.<br />

• Sempre in laboratorio viene costruita la protesi provvisoria<br />

utilizzando procedure convenzionali.<br />

Connessione e cementazione<br />

• Posizionare l’abutment sull’impianto.<br />

• Per verificare il corretto inserimento, può essere utile una radiografia.<br />

• Serrare a 35 Ncm usando un Manual Torque Wrench Prosthetic<br />

(Manual Torque Wrench protesico) e un Screwdriver Machine<br />

Unigrip (cacciavite da manipolo Unigrip ).<br />

• Controllare la protesi provvisoria e cementare con cemento<br />

provvisorio.<br />

• Il cemento provvisorio in eccesso viene rimosso secondo le<br />

procedure standard. Controllare l’occlusione.<br />

19


procedure di finalizzazione<br />

Funzionalità differita in due fasi<br />

La procedura chirurgica in due fasi protegge gli impianti dentali dal<br />

carico funzionale accidentale mantenendo gli impianti sotto la mucosa<br />

al momento dell’installazione.<br />

Utilizzare la funzionalità differita in due fasi:<br />

• Quando si desideri un periodo di guarigione prolungato.<br />

• In casi compromessi con ridotta capacità di guarigione<br />

• Quando si utilizzino procedure di innesto estese e avanzate.<br />

Seconda fase chirurgica<br />

Esposizione dell’impianto<br />

Brånemark System ® Second<br />

Stage Surgery Kit (kit chirurgico<br />

per seconda fase Brånemark<br />

System ® )<br />

• Utilizzare un Soft Tissue Punch (bisturi circolare) o praticare<br />

un’incisione separata per esporre la vite di copertura.<br />

Rimuovere la vite di copertura<br />

• Utilizzare lo Cover Screw Mill (strumento per rimuovere l’osso<br />

dalla vite di copertura) per l’asportazione di eventuale tessuto<br />

osseo formatosi sopra la vite di copertura.<br />

• Rimuovere la vite di copertura con il Cover Screw Driver Hexagon<br />

(cacciavite esagonale per vite di copertura).<br />

Connessione dell’abutment di guarigione<br />

• Utilizzare lo Bone Mill Brånemark System ® (strumento per la<br />

rimozione dell’osso Brånemark System ® ) per asportare eventuali<br />

frammenti di osso dalla sommità dell’impianto.<br />

• Connettere l’Healing Abutment Brånemark System ® adeguato<br />

con il Screwdriver Manual Unigrip (cacciavite manuale<br />

Unigrip ).<br />

20


soluzioni di finalizzazione raccomandate<br />

Dente singolo mancante Elementi multipli Edentulismo totale<br />

Basic<br />

Esthetic Abutment, Procera ® Crown<br />

(corona Procera ® ) e NOBELRONDO <br />

Procera ® Implant Bridge, a livello<br />

dell’impianto<br />

“All-on-4” (abutment Multi-Unit e<br />

ponte in acrilico)<br />

Premium<br />

Procera ® Abutment Zirconia,<br />

Procera ® Crown (corona Procera ® )<br />

e NOBELRONDO <br />

Procera ® Abutment Zirconia,<br />

Procera ® Bridge Zirconia (ponte Procera ®<br />

Zirconia) e NOBELRONDO <br />

Procera ® Implant Bridge<br />

21


considerazioni preoperatorie<br />

Immediate Function <br />

La validità della procedura Immediate Function con impianti <strong>Nobel</strong> <strong>Biocare</strong><br />

è clinicamente dimostrata e i tassi di successo sono pari o superiori a quelli<br />

dei protocolli convenzionali*. I risultati degli studi dimostrano che l’uso di<br />

Immediate Function è possibile in tutte le indicazioni.<br />

Criteri di inclusione/esclusione<br />

• Stato gengivale/parodontale/periapicale dei denti adiacenti buono<br />

• Relazione occlusale stabile e favorevole<br />

• Nessuna patologia apicale nel sito implantare<br />

• Volume e densità dell’osso adeguati<br />

• Nessun bruxismo pronunciato.<br />

Alta risoluzione delle proteine a livello dell’interfaccia<br />

tra tessuto connettivo e TiUnite ® .<br />

Come per qualunque altra procedura, il medico è responsabile dell’identificazione<br />

dei benefici e dei rischi di Immediate Function , rispetto al carico<br />

differito per quel determinato paziente e sito implantare.<br />

Nell’esecuzione del trattamento, occorre comunque tenere conto dei<br />

seguenti elementi:<br />

Elevata stabilità iniziale dell’impianto<br />

Il livello di stabilità è influenzato dalla diversa quantità e qualità ossea e dalle<br />

tecniche di preparazione. Gli impianti dovrebbero essere ben ancorati all’osso<br />

e dovrebbero essere in grado di sostenere un torque di serraggio di 35-45<br />

Ncm.<br />

Carichi controllati<br />

Ridurre fattori di carico potenziale come estensioni, contatto occlusale laterale,<br />

occlusione instabile e grave bruxismo. Gli impianti splintati sono<br />

preferibili rispetto a quelli non splintati.<br />

Estensioni ossee ancorate ai pori di<br />

TiUnite ® come appaiono dopo la<br />

rimozione dell’impianto.<br />

Superfici implantari osteoconduttive<br />

È stato dimostrato che la superficie TiUnite ® degli impianti <strong>Nobel</strong> <strong>Biocare</strong> favorisce<br />

il processo di guarigione e il migliore mantenimento della stabilità iniziale<br />

dell’impianto rispetto agli impianti in titanio. TiUnite ® è una superficie<br />

altamente osteoconduttiva ed è raccomandata per Immediate Function .<br />

Programma post-chirurgia e igiene orale<br />

Il follow-up post-chirurgico è lo stesso di qualunque altro intervento di<br />

chirurgia orale. Può essere indicata una terapia antibiotica per il giorno dell’intervento<br />

e successivamente ancora per qualche giorno.<br />

Protesi definitiva<br />

La protesi definitiva può essere posizionata dopo una valutazione clinica individuale<br />

e dipende principalmente dallo stato di guarigione dei tessuti.<br />

Crescita ossea sulla superficie TiUnite ®<br />

(SEM a 8,5 mesi di guarigione; istologia<br />

umana). Per gentile concessione del Dott.<br />

Peter Schüpbach e del Dott. Roland Glauser<br />

*Abstract degli studi sono disponibili sul sito www.nobelbiocare.com<br />

22


3.5 mm<br />

4.0 mm<br />

5.0 mm<br />

6.0 mm<br />

13<br />

10 mm 11.5 mm 13 mm<br />

10 11.5<br />

13<br />

15 mm<br />

15 18<br />

10 11.5 13 15 18<br />

10 11.5 13 15 18<br />

13<br />


appendice I – kit<br />

32302 Brånemark System ® Surgery Kit<br />

(kit chirurgico Brånemark System ® )<br />

32312<br />

29149<br />

29164<br />

32297**<br />

32261**<br />

32267**<br />

32270**<br />

32273**<br />

32948<br />

32110<br />

32264**<br />

32276**<br />

32112 × 4<br />

32279**<br />

W<br />

P<br />

R<br />

P<br />

DIB 097-0<br />

29126*<br />

29129<br />

29134*<br />

W<br />

P<br />

29128*<br />

29130<br />

29135*<br />

26017.ep<br />

29132<br />

26366.eps<br />

29136*<br />

* Articolo non incluso in questo kit<br />

** Articolo non incluso in questo kit e disponibile anche in altre lunghezze<br />

Nota: altri strumenti per gli impianti NP e wp devono essere<br />

ordinati separatamente.<br />

24


appendice I – kit<br />

<strong>Nobel</strong> <strong>Biocare</strong> ® Flapless Surgery Kit 32304<br />

Il kit comprende:<br />

(Gli articoli sono disponibili anche separatamente)<br />

<strong>Nobel</strong> <strong>Biocare</strong> ® Flapless Surgery Kit Box 32317<br />

Tissue Punch NP 29628<br />

Tissue Punch RP 29629<br />

Tissue Punch WP 29630<br />

Tissue Punch ∅ 6 32672<br />

Tissue Punch Guide NP 29631<br />

Tissue Punch Guide RP 29632<br />

Tissue Punch Guide WP 29633<br />

Tissue Punch Guide ∅ 6 32673<br />

Drill Guide NP 29634<br />

Drill Guide RP 29635<br />

Drill Guide WP 29636<br />

Drill Guide 6.0 29674<br />

Prosthetic Kit 32309<br />

Il kit comprende:<br />

(Gli articoli sono disponibili anche separatamente)<br />

Prosthetic Kit Box (senza strumenti) 32322<br />

Manual Torque Wrench Prosthetic 29165<br />

Screwdriver Machine Unigrip 20mm 29151<br />

Screwdriver Machine Unigrip 30mm 29153<br />

Screwdriver Machine Multi-unit 21mm 29158<br />

Brånemark System ® Second Stage Surgery Kit 32308<br />

Il kit comprende:<br />

(Gli articoli sono disponibili anche separatamente)<br />

Bone Mill NP 28977<br />

Bone Mill RP 28978<br />

Bone Mill WP 28979<br />

Cover Screw Mill NP 28980<br />

Cover Screw Mill RP 28981<br />

Cover Screw Mill WP 28982<br />

Cover Screw Driver<br />

DIB097-0<br />

Ungrip Driver 29149<br />

25


appendice II – manual torque wrench<br />

Manual Torque Wrench Surgical/Prosthetic<br />

(chirurgico/protesico)<br />

Per il chirurgo, il torque richiesto per posizionare gli impianti fornisce<br />

un’indicazione della stabilità iniziale dell’impianto.<br />

Nelle procedure protesiche, serrando l’abutment e le viti protesiche<br />

al torque raccomandato si otterrà un controllo più efficace della<br />

giunzione a vite durante la funzione.<br />

Il Manual Torque Wrench è uno strumento comodo per ottenere il<br />

grado di torque desiderato.<br />

Manual Torque Wrench – Surgical (chirurgico)<br />

Indicato per il serraggio o la regolazione della posizione degli<br />

impianti.<br />

• Inserire Implant Driver Wrench Adapter Brånemark System ®<br />

(l’adattatore per chiave del driver per impianto Brånemark<br />

System ® )<br />

Manual Torque Wrench – Prosthetic (protesico)<br />

Indicato per le viti di fissaggio con un torque di serraggio di<br />

15 – 35 Ncm. Compatibile con tutti i cacciaviti da manipolo.<br />

• Inserire il driver più indicato.<br />

• Per l’uso e il torque di serraggio corretti, vedere il manuale del<br />

prodotto che si sta utilizzando. Il massimo torque di serraggio,<br />

45 Ncm, è indicato da una linea sulla scala.<br />

Nota: nelle immagini è illustrata l’applicazione chirurgica.<br />

• Per allentare le viti o estrarre l’impianto utilizzare il cricchetto con<br />

la freccia indicatrice di posizione rivolta in senso antiorario.<br />

Nota: nelle immagini è illustrata l’applicazione chirurgica.<br />

Attenzione: utilizzando il corpo della chiave invece del braccio di leva<br />

si rischia di esercitare un torque eccessivo sulla vite e/o sul sito implantare.<br />

Nota: nelle immagini è illustrata l’applicazione chirurgica.<br />

26


appendice III – utilizzo degli osteotomi<br />

Utilizzo degli osteotomi<br />

Gli osteotomi devono essere utilizzati esclusivamente in osso mascellare<br />

morbido. Dopo la preparazione con la Twist Drill iniziale fino<br />

alla profondità, questi strumenti si utilizzano per creare manualmente<br />

il sito comprimendo lateralmente l’osso, compattandolo ed<br />

evitando di togliere l’osso stesso dal sito chirurgico.<br />

Il design universale degli osteotomi <strong>Nobel</strong> <strong>Biocare</strong> consente di utilizzarli<br />

con gli impianti Brånemark System ® , <strong>Nobel</strong>Replace Straight,<br />

<strong>Nobel</strong>Replace Tapered, <strong>Nobel</strong>Speedy , <strong>Nobel</strong>Direct ® e <strong>Nobel</strong>Perfect<br />

® .<br />

Procedura<br />

Kit osteotomi <strong>Nobel</strong><strong>Biocare</strong><br />

1. Segnare i fori pilota iniziali con una Twist Drill ∅ 2 mm fino a<br />

profondità completa.<br />

2. Inserire l’osteotomo con punta da 2,5 mm nel foro pilota e premere<br />

lo strumento nell’osso ruotandolo, evitando di fare leva da<br />

un lato all’altro o fuori asse. Se l’osso è un po’ più denso, può essere<br />

necessario battere l’osteotomo con un martelletto fino alla<br />

profondità desiderata. Lasciare l’osteotomo in posizione per circa<br />

10 secondi in modo che l’osso si rilassi. Rimuovere l’osteotomo<br />

ruotandolo ed estraendolo contemporaneamente.<br />

3. Procedendo allo stesso modo, continuare con gli osteotomi<br />

∅ 3,0 - 5,0 mm per allargare il sito in modo sequenziale fino alla<br />

larghezza e profondità desiderate.<br />

Nota: le profondità di posizionamento e i diametri degli osteotomi<br />

utilizzati possono variare dalla procedura standard in base al giudizio<br />

del chirurgo. In alcune situazioni, è possibile ricorrere a una procedura<br />

graduale, in cui l’osteotomo finale non raggiunge la profondità completa,<br />

consentendo così alla punta dell’impianto di ingaggiare l’osso<br />

prima dell’inizio dell’azione autofilettante.<br />

Le tacche di profondità degli osteotomi corrispondono<br />

a una lunghezza effettiva di 8, 10, 13, 16 mm.<br />

27


appendice – IV<br />

Utilizzo del Drill Stop<br />

Per una procedura chirurgica sicura e accurata, montare un Drill<br />

Stop sulla Twist Drill.<br />

Il kit per Drill Stop è impiegato per la loro conservazione e sterilizzazione<br />

in autoclave, nonché per agevolarne la procedura di montaggio.<br />

Il kit per Drill Stop contiene Drill Stop per Twist Drill e Twist Step<br />

Drill con diametro:∅ 2, ∅ 2,8, ∅ 3, ∅ 3,2, ∅ 3,4, ∅ 3,6 e ∅ 4,2<br />

mm.<br />

Fori di montaggio<br />

• Far scorrere il Drill Stop adatto sulla fresa.<br />

• Posizionare la fresa nel foro di montaggio corrispondente alla<br />

profondità desiderata della fresa.<br />

• Utilizzare fori larghi per frese ∅ 3,4 e superiori*.<br />

*<br />

Connessione del Drill Stop<br />

• Serrare la vite di fissaggio con un cacciavite Unigrip .<br />

Importante: i Drill Stop sono adatti esclusivamente a Twist Drill e a<br />

Twist Step Drill con lunghezze effettive in millimetri.<br />

Importante: il Drill Stop è valido solo per i seguenti impianti: Brånemark System ® Mk III<br />

Groovy, <strong>Nobel</strong>Speedy Groovy, <strong>Nobel</strong>Replace Straight Groovy e <strong>Nobel</strong>Speedy Replace ® .<br />

28


appendice – V<br />

Pulizia e sterilizzazione<br />

Frese monouso<br />

Tutte le frese e i maschiatori sono monouso e devono essere<br />

utilizzati per un solo intervento chirurgico. Non risterilizzare le<br />

frese monouso.<br />

Strumenti<br />

• Gli strumenti devono essere puliti e sterilizzati prima<br />

dell’uso intraorale seguendo le procedure abituali.<br />

Procedura generale di pulizia e sterilizzazione<br />

• Pulire e disinfettare gli strumenti e le frese in una lavastrumenti.<br />

In alternativa: disinfettarli e pulirli in una vasca a ultrasuoni.<br />

• Asciugare gli strumenti e confezionarli per la sterilizzazione.<br />

• Sterilizzare gli strumenti in autoclave a vapore (seguendo le<br />

istruzioni del produttore).<br />

Pulizia dei contrangoli<br />

• Il contrangolo deve essere pulito a fondo immediatamente<br />

dopo l’uso.<br />

• Prima pulire in una lavastrumenti o sotto acqua corrente. Separare<br />

la testina dal manipolo e lubrificare accuratamente entrambe<br />

le parti.<br />

In alternativa, pulire e lubrificare con un apparecchio automatico<br />

apposito.<br />

• Posizionare il contrangolo smontato in una doppia busta con<br />

apertura a strappo oppure in un vassoio, quindi sterilizzarlo in<br />

autoclave.<br />

5 min<br />

Protesi e abutment modificati<br />

135˚C/276˚F<br />

• Se indicato, gli abutment e le protesi modificati, forniti dal laboratorio<br />

odontotecnico, devono essere puliti e sterilizzati secondo<br />

le procedure comunemente adottate.<br />

Manual Torque Wrench<br />

Pulire accuratamente tutti i componenti. Lasciarli asciugare completamente.<br />

Sterilizzare gli strumenti in autoclave a vapore a<br />

135°C per un tempo di esposizione minimo di 5 minuti secondo<br />

le istruzioni del produttore.<br />

Strumento per rimuovere l’osso dalla vite di copertura<br />

1. Allentare la vite sul retro del manipolo e rimuoverlo<br />

2. Rimuovere la molla<br />

3. Rimuovere il perno<br />

4. Pulire lo strumento per rimuovere l’osso dalla vite di copertura<br />

come descritto sopra<br />

5. Lasciare asciugare completamente i componenti prima di riassemblarli<br />

6. Sterilizzare come descritto sopra.<br />

29


diagramma di flusso<br />

<strong>NOBELSPEEDY</strong> Groovy e Shorty<br />

Implants<br />

(Impianti)<br />

Drills<br />

(Frese)<br />

Drill Stop<br />

<strong>NOBELSPEEDY</strong> Groovy NP ∅ 3,3 mm<br />

TiUnite ®<br />

10 mm 3312<br />

11,5 mm 33124<br />

13 mm 33125<br />

15 mm 33126<br />

Twist Drills<br />

∅ 1.5 × 7–15 mm 31278<br />

∅ 2 × 7–10 mm 32296<br />

∅ 2 × 7–15 mm 32297<br />

∅ 2 × 10–18 mm 32299<br />

Vite di copertura non inclusa<br />

Twist Step Drills<br />

∅ 2.4/2.8 × 7–10 mm 32260<br />

∅ 2.4/2.8 × 7–15 mm 32261<br />

∅ 2.4/2.8 × 10–18 mm 32262<br />

Precision Drill 33071<br />

∅ 2.0 mm 33063<br />

∅ 2.8 mm 33064<br />

<strong>NOBELSPEEDY</strong> Shorty RP ∅ 4,0 mm<br />

TiUnite ®<br />

7 mm 32146<br />

<strong>NOBELSPEEDY</strong> Groovy RP ∅ 4,0 mm<br />

TiUnite ®<br />

8,5 mm 32147<br />

10 mm 32148<br />

11,5 mm 32149<br />

13 mm 32150<br />

15 mm 32151<br />

18 mm 32152<br />

Vite di copertura non inclusa<br />

Twist Drills<br />

∅ 1.5 × 7–15 mm 31278<br />

∅ 2 × 7–10 mm 32296<br />

∅ 2 × 7–15 mm 32297<br />

∅ 2 × 10–18 mm 32299<br />

∅ 3.2 × 7–10 mm 32269<br />

∅ 3.2 × 7–15 mm 32270<br />

∅ 3.2 × 10–18 mm 32271<br />

∅ 3.4 × 7–10 mm 32272<br />

∅ 3.4 × 7–15 mm 32273<br />

∅ 3.4 × 10–18 mm 32274<br />

Twist Step Drills<br />

∅ 2.4/2.8 × 7–10 mm 32260<br />

∅ 2.4/2.8 × 7–15 mm 32261<br />

∅ 2.4/2.8 × 10–18 mm 32262<br />

Precision Drill 33071<br />

∅ 2.0 mm 33063<br />

∅ 2.8 mm 33064<br />

∅ 3.0 mm 33075<br />

∅ 3.2 mm 33077<br />

∅ 3.4 mm 33078<br />

30


diagramma di flusso<br />

Counterbore<br />

(Svasatore)<br />

Screw Taps<br />

(Maschiatori)<br />

Implant Driver<br />

(Driver per impianto)<br />

Healing Abutment<br />

(Abutment di guarigione)<br />

R<br />

P<br />

Bmk Syst NP<br />

∅ 4.0 mm<br />

3 mm 28990<br />

4 mm 28991<br />

Bmk Syst<br />

10-15 mm 32289<br />

Bmk Syst NP<br />

5 mm 28992<br />

Counterbore NP 32281<br />

26 mm 29126<br />

34 mm 29127<br />

∅ 5.0 mm<br />

3 mm 28993<br />

4 mm 28994<br />

5 mm 28995<br />

R<br />

P<br />

Bmk Syst<br />

∅ 4 mm<br />

Bmk Syst RP<br />

Bmk Syst RP<br />

Counterbore RP 32283<br />

7–13 mm 33072<br />

7–18 mm 33073<br />

21 mm 29129<br />

26 mm 29130<br />

34 mm 29131<br />

∅ 5 mm<br />

3 mm 29137<br />

4 mm 29138<br />

5 mm 29139<br />

7 mm 29140<br />

Procedura chirurgica<br />

31


diagramma di flusso<br />

<strong>NOBELSPEEDY</strong> Groovy e Shorty<br />

Implants<br />

(Impianti)<br />

Drills<br />

(Frese)<br />

Drill Stop<br />

<strong>NOBELSPEEDY</strong> Shorty WP ∅ 5,0 mm<br />

TiUnite ®<br />

7 mm 32153<br />

<strong>NOBELSPEEDY</strong> Groovy WP ∅ 5,0 mm<br />

TiUnite ®<br />

Twist Drill<br />

∅ 1,5 × 7-15 mm 31278<br />

∅ 2 × 7-10 mm 32296<br />

∅ 2 × 7-15 mm 32297<br />

∅ 2 × 10-18 mm 32299<br />

∅ 3 × 7-10 mm 32266<br />

∅ 3 × 7-15 mm 32267<br />

∅ 3 × 10-18 mm 32268<br />

8,5 mm 32154<br />

10 mm 32155<br />

11,5 mm 32156<br />

13 mm 32157<br />

15 mm 32158<br />

18 mm 32159<br />

Vite di copertura non inclusa<br />

Twist Step Drill<br />

∅ 2,4/2,8 × 7-10 mm 32260<br />

∅ 2,4/2,8 × 7-15 mm 32261<br />

∅ 2,4/2,8 × 10-18 mm 32262<br />

∅ 3,2/3,6 × 7-10 mm 32263<br />

∅ 3,2/3,6 × 7-15 mm 32264<br />

∅ 3,2/3,6 × 10-18 mm 32265<br />

∅ 3,8/4,2 × 7-10 mm 32275<br />

∅ 3,8/4,2 × 7-15 mm 32276<br />

∅ 3,8/4,2 × 10-18 mm 32277<br />

∅ 2 mm 33063<br />

∅ 2,8 mm 33064<br />

∅ 3 mm 33075<br />

∅ 3,2 mm 33077<br />

∅ 3,6 mm 33084<br />

∅ 4,2 mm 33081<br />

Precision Drill 33071<br />

<strong>NOBELSPEEDY</strong> Shorty WP ∅ 6,0 mm<br />

TiUnite ®<br />

7 mm 32139<br />

<strong>NOBELSPEEDY</strong> Groovy WP ∅ 6,0 mm<br />

TiUnite ®<br />

8,5 mm 32140<br />

10 mm 32141<br />

11,5 mm 32142<br />

13 mm 32143<br />

15 mm 32144<br />

18 mm 32145<br />

Vite di copertura non inclusa<br />

Twist Drill<br />

∅ 2 × 7-10 mm 32296<br />

∅ 2 × 7-15 mm 32297<br />

∅ 2 × 10-18 mm 32299<br />

∅ 5 × 7-10 mm 32278<br />

∅ 5 × 7-15 mm 32279<br />

∅ 5 × 10-18 mm 32280<br />

Twist Step Drill<br />

Vedi sopra<br />

Precision Drill 33071<br />

∅ 2 mm 33063<br />

∅ 2,8 mm 33064<br />

∅ 3,2 mm 33077<br />

∅ 3,6 mm 33084<br />

∅ 4,2 mm 33081<br />

32


diagramma di flusso<br />

Counterbore<br />

(Svasatore)<br />

Screw Taps<br />

(Maschiatori)<br />

Implant Driver<br />

(Driver per impianto)<br />

Healing Abutment<br />

(Abutment di guarigione)<br />

Bmk Syst<br />

∅ 5.0 × 7–13 mm 32292<br />

Bmk Syst WP<br />

Bmk Syst WP<br />

Counterbore WP 32285<br />

∅ 5.0 × 7–18 mm 32293<br />

W<br />

P<br />

W<br />

P<br />

21 mm 29134<br />

26 mm 29135<br />

∅ 6.0 mm<br />

3 mm 29141<br />

4 mm 29142<br />

5 mm 29143<br />

Bmk Syst WP<br />

∅ 6.0 mm<br />

Bmk Syst<br />

Counterbore WP 32285<br />

∅ 6.0 × 7–13 mm 32294<br />

∅ 6.0 × 7–18 mm 32295<br />

Bmk Syst WP<br />

21 mm 29134<br />

26 mm 29135<br />

3 mm 29141<br />

4 mm 29142<br />

5 mm 29143<br />

Procedura chirurgica<br />

33


catalogo prodotti<br />

Implants (Impianti)<br />

33123 <strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 10 mm<br />

33124 <strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 11.5 mm<br />

33125 <strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 13mm<br />

33126 <strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 15 mm<br />

32146 <strong>NOBELSPEEDY</strong> Shorty RP ∅ 4<br />

32147 <strong>NOBELSPEEDY</strong> Groovy RP 4 × 8.5 mm<br />

32148 <strong>NOBELSPEEDY</strong> Groovy RP 4 × 10 mm<br />

32149 <strong>NOBELSPEEDY</strong> Groovy RP 4 × 11.5 mm<br />

32150 <strong>NOBELSPEEDY</strong> Groovy RP 4 × 13mm<br />

32151 <strong>NOBELSPEEDY</strong> Groovy RP 4 × 15 mm<br />

32152 <strong>NOBELSPEEDY</strong> Groovy RP 4 × 18 mm<br />

32153 <strong>NOBELSPEEDY</strong> Shorty WP ∅ 5<br />

32154 <strong>NOBELSPEEDY</strong> Groovy WP 5 × 8.5 mm<br />

32155 <strong>NOBELSPEEDY</strong> Groovy WP 5 × 10 mm<br />

32156 <strong>NOBELSPEEDY</strong> Groovy WP 5 × 11.5 mm<br />

32157 <strong>NOBELSPEEDY</strong> Groovy WP 5 × 13mm<br />

32158 <strong>NOBELSPEEDY</strong> Groovy WP 5 × 15 mm<br />

32159 <strong>NOBELSPEEDY</strong> Groovy WP 5 × 18 mm<br />

32139 <strong>NOBELSPEEDY</strong> Shorty WP ∅ 6<br />

32140 <strong>NOBELSPEEDY</strong> Groovy WP 6 × 8.5 mm<br />

32141 <strong>NOBELSPEEDY</strong> Groovy WP 6 × 10 mm<br />

32142 <strong>NOBELSPEEDY</strong> Groovy WP 6 × 11.5 mm<br />

32143 <strong>NOBELSPEEDY</strong> Groovy WP 6 × 13mm<br />

32144 <strong>NOBELSPEEDY</strong> Groovy WP 6 × 15 mm<br />

32145 <strong>NOBELSPEEDY</strong> Groovy WP 6 × 18 mm<br />

Drills (Frese)<br />

31278 Twist Drill 1.5 × 7–15 mm<br />

32296 Twist Drill w Tip 2 × 7–10 mm<br />

32297 Twist Drill w Tip 2 × 7–15 mm<br />

32299 Twist Drill w Tip 2 × 10–18 mm<br />

32266 Twist Drill 3 × 7–10 mm<br />

32267 Twist Drill 3 × 7–15 mm<br />

32268 Twist Drill 3 × 10–18 mm<br />

32269 Twist Drill 3.2 × 7–10 mm<br />

32270 Twist Drill 3.2 × 7–15 mm<br />

32271 Twist Drill 3.2 × 10–18 mm<br />

32272 Twist Drill 3.4 × 7–10 mm<br />

32273 Twist Drill 3.4 × 7–15 mm<br />

32274 Twist Drill 3.4 × 10–18 mm<br />

32278 Twist Drill 5 × 7–10 mm<br />

32279 Twist Drill 5 × 7–15 mm<br />

32280 Twist Drill 5 × 10–18 mm<br />

32260 Twist Step Drill 2.4/2.8 7–10 mm<br />

32261 Twist Step Drill 2.4/2.8 7–15 mm<br />

32262 Twist Step Drill 2.4/2.8 10–18 mm<br />

32263 Twist Step Drill 3.2/3.6 7–10 mm<br />

32264 Twist Step Drill 3.2/3.6 7–15 mm<br />

32265 Twist Step Drill 3.2/3.6 10–18 mm<br />

32275 Twist Step Drill 3.8/4.2 7–10 mm<br />

32276 Twist Step Drill 3.8/4.2 7–15 mm<br />

32277 Twist Step Drill 3.8/4.2 10–18 mm<br />

33071 Precision Drill<br />

34


catalogo prodotti<br />

Drill Stop<br />

33063 Drill Stop ∅ 2<br />

33064 Drill Stop ∅ 2.8<br />

33075 Drill Stop ∅ 3<br />

33077 Drill Stop ∅ 3.2<br />

33078 Drill Stop ∅ 3.4<br />

33084 Drill Stop ∅ 3.6<br />

33081 Drill Stop ∅ 4.2<br />

Counterbores (Svasatori)<br />

32281 Brånemark System ® Counterbore NP<br />

32283 Brånemark System ® Counterbore RP<br />

32285 Brånemark System ® Counterbore WP<br />

Screw Taps (Maschiatori)<br />

32289 Screw Tap NP 10–15 mm<br />

33072 Screw Tap RP ∅ 4 7–13mm<br />

33073 Screw Tap RP ∅ 4 7–18 mm<br />

32292 Screw Tap WP ∅ 5 7–13mm<br />

32293 Screw Tap WP ∅ 5 7–18 mm<br />

32294 Screw Tap NobRpl 6.0/Bmk Syst WP ∅ 6 7–13mm<br />

32295 Screw Tap NobRpl 6.0/Bmk Syst WP ∅ 6 7–18 mm<br />

Implant Driver (Driver per impianto)<br />

29126 Implant Driver Bmk Syst NP 26 mm<br />

29127 Implant Driver Bmk Syst NP 34 mm<br />

29129 Implant Driver Bmk Syst RP 21 mm<br />

29130 Implant Driver Bmk Syst RP 26 mm<br />

29131 Implant Driver Bmk Syst RP 34 mm<br />

29134 Implant Driver Bmk Syst WP 21 mm<br />

29135 Implant Driver Bmk Syst WP 26 mm<br />

29128 Impl Driver Wrench Adap Bmk Syst NP 21 mm<br />

29132 Impl Driver Wrench Adap Bmk Syst RP 12 mm<br />

29133 Impl Driver Wrench Adap Bmk Syst RP 21 mm<br />

29136 Impl Driver Wrench Adap Bmk Syst WP 12 mm<br />

Healing Abutment (Abutment di guarigione)<br />

28990 Healing Abutment Bmk Syst NP ∅ 4 × 3 mm<br />

28991 Healing Abutment Bmk Syst NP ∅ 4 × 4 mm<br />

28992 Healing Abutment Bmk Syst NP ∅ 4 × 5 mm<br />

28993 Healing Abutment Bmk Syst NP ∅ 5 × 3 mm<br />

28994 Healing Abutment Bmk Syst NP ∅ 5 × 4 mm<br />

28995 Healing Abutment Bmk Syst NP ∅ 5 × 5 mm<br />

29137 Healing Abutment Bmk Syst RP ∅ 5 × 3 mm<br />

29138 Healing Abutment Bmk Syst RP ∅ 5 × 4 mm<br />

29139 Healing Abutment Bmk Syst RP ∅ 5 × 5 mm<br />

29140 Healing Abutment Bmk Syst RP ∅ 5 × 7 mm<br />

29141 Healing Abutment Bmk Syst WP ∅ 6 × 3 mm<br />

29142 Healing Abutment Bmk Syst WP ∅ 6 × 4 mm<br />

29143 Healing Abutment Bmk Syst WP ∅ 6 × 5 mm<br />

35


catalogo prodotti<br />

Immediate Temporary Abutment<br />

31643 Immediate Temp Abutm Brånemark System ® NP<br />

31644 Immediate Temp Abutm Brånemark System ® RP<br />

31655 Immediate Temp Abutm Brånemark System ® WP<br />

Temporary Abutments Non–Eng<br />

29029 Temporary Abutment Non–Engaging Brånemark System ® NP<br />

29031 Temporary Abutment Non–Engaging Brånemark System ® RP<br />

29033 Temporary Abutment Non–Engaging Brånemark System ® WP<br />

Esthetic Abutment<br />

Esthetic Abutment BS<br />

32396 Esthetic Abutment Bmk Syst NP 2 mm<br />

32397 Esthetic Abutment Bmk Syst RP 1 mm<br />

32399 Esthetic Abutment Bmk Syst RP 3mm<br />

32398 Esthetic Abutment Bmk Syst WP 1 mm<br />

15° Esthetic Abutment<br />

32400 15º Esthetic Abutment Bmk Syst NP 2 mm<br />

32401 15º Esthetic Abutment Bmk Syst RP 1 mm<br />

32403 15º Esthetic Abutment Bmk Syst RP 3mm<br />

32402 15º Esthetic Abutment Bmk Syst WP 1 mm<br />

Screwdriver (Cacciavite)<br />

29148 Screwdriver Manual Unigrip 20 mm<br />

29149 Screwdriver Manual Unigrip 28 mm<br />

29150 Screwdriver Manual Unigrip 36 mm<br />

29151 Screwdriver Machine Unigrip 20 mm<br />

29152 Screwdriver Machine Unigrip 25 mm<br />

29153 Screwdriver Machine Unigrip 30 mm<br />

29154 Screwdriver Machine Unigrip 35 mm<br />

Cover Screw (Vite di copertura)<br />

28986 Cover Screw Brånemark System ® NP<br />

28987 Cover Screw Brånemark System ® RP<br />

28988 Cover Screw Brånemark System ® WP<br />

Manual Torque Wrench<br />

32110 Brånemark System ® Manual Torque Wrench Surgical<br />

32111 Brånemark System ® Manual Torque Wrench Adapt Surg<br />

29165 Manual Torque Wrench Prosthetic<br />

29167 Manual Torque Wrench Adapter Prosthetic<br />

36


catalogo prodotti<br />

Tissue Punch (Bisturi circolare)<br />

32672 Tissue Punch 6.0<br />

29628 Tissue Punch NP<br />

29629 Tissue Punch RP<br />

29630 Tissue Punch WP<br />

Tissue Punch Guide (Guida del bisturi circolare)<br />

29631 Tissue Punch Guide NP<br />

29632 Tissue Punch Guide RP<br />

29633 Tissue Punch Guide WP<br />

32673 Tissue Punch Guide 6.0<br />

32Z2000<br />

32Z2002<br />

32Z2004<br />

Soft Tissue Punch (Bisturi circolare)<br />

Soft Tissue Punch ∅ 4.1 mm, 5–pack<br />

Soft Tissue Punch ∅ 5.2 mm, 5–pack<br />

Soft Tissue Punch ∅ 6.2 mm, 5–pack<br />

Drill Guide (Guida della fresa)<br />

29634 Drill Guide NP<br />

29635 Drill Guide RP<br />

29636 Drill Guide WP<br />

32674 Drill Guide 6.0<br />

Cover Screw Mills<br />

(Strumenti per rimuovere l’osso dalla vite di copertura)<br />

28980 Cover Screw Mill Brånemark System ® NP<br />

28981 Cover Screw Mill Brånemark System ® RP<br />

28982 Cover Screw Mill Brånemark System ® WP<br />

28977 Bone Mill Brånemark System ® NP<br />

28978 Bone Mill Brånemark System ® RP<br />

28979 Bone Mill Brånemark System ® WP<br />

33129 Brånemark System ® Wall chart<br />

33097 Brånemark System ® /<strong>NOBELSPEEDY</strong> Radiographic Template<br />

32948 Depth Probe<br />

32112 Direction Indicator ∅ 2/∅ 2.4–2.8 mm<br />

29164 Drill Extension Shaft<br />

29543 Implant Sleeve Holder<br />

Kits (Kit)<br />

32308 Brånemark System ® Second Stage Surgery Kit<br />

32302 Brånemark System ® Surgery Kit<br />

32304 <strong>Nobel</strong> <strong>Biocare</strong> ® Flapless Surgery Kit<br />

32430 Drill Stop Kit<br />

32321 <strong>Nobel</strong> <strong>Biocare</strong> ® Osteotome Kit<br />

32315 Brånemark System ® Second Stage Surgery Kit Box<br />

32312 Brånemark System ® Surgery Kit Box<br />

32317 <strong>Nobel</strong> <strong>Biocare</strong> ® Flapless Surgery Kit Box<br />

32309 Prosthetic Kit<br />

33062 Drill Stop Kit Box<br />

33085 Guided Drill Stop Kit<br />

32311 Kit Organizer<br />

37


elenco prodotti<br />

Indice in ordine alfabetico<br />

Descrizione N. articolo Page<br />

B<br />

C<br />

Bone Mill Brånemark System ® NP . . . . . . . . . . . . . . . . .28977 . . . . . . . . . . . . . .25, 37<br />

Bone Mill Brånemark System ® RP . . . . . . . . . . . . . . . . .28978 . . . . . . . . . . . . . .25, 37<br />

Bone Mill Brånemark System ® WP . . . . . . . . . . . . . . . . .28979 . . . . . . . . . . . . . .25, 37<br />

Brånemark System ® /<strong>NOBELSPEEDY</strong> <br />

Radiographic Template . . . . . . . . . . . . . . . . . . . . . . . .33097 . . . . . . . . . . . . . .23, 38<br />

Brånemark System ® Wall chart . . . . . . . . . . . . . . . . . . .33129 . . . . . . . . . . . . . . . . .37<br />

Counterbores (Svasatori)<br />

Brånemark System ® Counterbore NP . . . . . . . . . . . . . .32281 . . . . . . . . . . . . . . . . .31<br />

Brånemark System ® Counterbore RP . . . . . . . . . . . . . .32283 . . . . . . . . . . . . . . . . .31<br />

Brånemark System ® Counterbore WP . . . . . . . . . . . . . .32285 . . . . . . . . . . . . . . . . .33<br />

Cover Screw (Viti di Copertura)<br />

Cover Screw Brånemark System ® NP . . . . . . . . . . . . . .28986 . . . . . . . . . . . . . .16, 36<br />

Cover Screw Brånemark System ® RP . . . . . . . . . . . . . . .28987 . . . . . . . . . . . . . .16, 36<br />

Cover Screw Brånemark System ® WP . . . . . . . . . . . . . .28988 . . . . . . . . . . . . . .16, 36<br />

Cover Screw Mill (Strumento per Rimuovere l'osso dalla Vite di Copertura)<br />

Cover Screw Mill Brånemark System ® NP . . . . . . . . . . .28980 . . . . . . . . . . .25, 29, 37<br />

Cover Screw Mill Brånemark System ® RP . . . . . . . . . . .28981 . . . . . . . . . . .25, 29, 37<br />

Cover Screw Mill Brånemark System ® WP . . . . . . . . . . .28982 . . . . . . . . . . .25, 29, 37<br />

Cover Screw Driver Bmk Syst Hexagon . . . . . . . . . . . .DIB 097-0 . . . . . . . . . . .20, 25<br />

D<br />

Depth Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32948 . . . . . . . . . . . . . .13, 37<br />

Direction Indicator ∅ 2/∅ 2.4–2.8 mm . . . . . . . . . . . .32112 . . . . . . . . . . .12, 13, 37<br />

Drill Extension Shaft . . . . . . . . . . . . . . . . . . . . . . . . . .29164 . . . . . . . . . . . . . . . . .37<br />

Drill Guide (Guida per Frese)<br />

Drill Guide NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29634 . . . . . . . . . . . .4, 25, 37<br />

Drill Guide RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29635 . . . . . . . . . . . .4, 25, 37<br />

Drill Guide WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29636 . . . . . . . . . . . .4, 25, 37<br />

Drill Guide 6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32674 . . . . . . . . . . . .4, 25, 37<br />

Drill Stop (Stop per Frese)<br />

Drill Stop ∅ 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33063 . . . . . . . . . . .28, 30, 32<br />

Drill Stop ∅ 2.8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33064 . . . . . . . . . . .28, 30, 32<br />

Drill Stop ∅ 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33075 . . . . . . . . . . .28, 30, 32<br />

Drill Stop ∅ 3.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33077 . . . . . . . . . . .28, 30, 32<br />

Drill Stop ∅ 3.4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33078 . . . . . . . . . . .28, 30, 32<br />

Drill Stop ∅ 3.6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33084 . . . . . . . . . . .28, 30, 32<br />

Drill Stop ∅ 4.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33081 . . . . . . . . . . .28, 30, 32<br />

Drill Stop Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32430 . . . . . . . . . . .28, 30, 32<br />

Drill Stop Kit Box . . . . . . . . . . . . . . . . . . . . . . . . . . . .33062 . . . . . . . . . . .28, 30, 32<br />

Drills (Frese)<br />

Twist Drill 1.5 × 7–15 mm . . . . . . . . . . . . . . . . . . . . . .31278 . . . . . . . . .6, 30, 32, 34<br />

Twist Drill 3 × 7–10 mm . . . . . . . . . . . . . . . . . . . . . . .32266 . . . . . . . . .6, 30, 32, 34<br />

Twist Drill 3 × 7–15 mm . . . . . . . . . . . . . . . . . . . . . . .32267 . . . . . . . . .6, 30, 32, 34<br />

Twist Drill 3 × 10–18 mm . . . . . . . . . . . . . . . . . . . . . .32268 . . . . . . . . .6, 30, 32, 34<br />

Twist Drill 3.2 × 7–10 mm . . . . . . . . . . . . . . . . . . . . . .32269 . . . . . .6, 13, 30, 32, 34<br />

Twist Drill 3.2 × 7–15 mm . . . . . . . . . . . . . . . . . . . . . .32270 . . . . . .6, 13, 30, 32, 34<br />

Twist Drill 3.2 × 10–18 mm . . . . . . . . . . . . . . . . . . . . .32271 . . . . . .6, 13, 30, 32, 34<br />

Twist Drill 3.4 × 7–10 mm . . . . . . . . . . . . . . . . . . . . . .32272 . . . . . .6, 13, 30, 32, 34<br />

Twist Drill 3.4 × 7–15 mm . . . . . . . . . . . . . . . . . . . . . .32273 . . . . . .6, 13, 30, 32, 34<br />

Twist Drill 3.4 × 10–18 mm . . . . . . . . . . . . . . . . . . . . .32274 . . . . . .6, 13, 30, 32, 34<br />

Twist Drill 5 × 7–10 mm . . . . . . . . . . . . . . . . . . . . . . .32278 . . . . . . . . .6, 30, 32, 34<br />

Twist Drill 5 × 7–15 mm . . . . . . . . . . . . . . . . . . . . . . .32279 . . . . . . . . .6, 30, 32, 34<br />

Twist Drill 5 × 10–18 mm . . . . . . . . . . . . . . . . . . . . . .32280 . . . . . . . . .6, 30, 32, 34<br />

Twist Drill w Tip 2 × 7–10 mm . . . . . . . . . . . . . . . . . .32296 . . . . . .6, 12, 30, 32, 34<br />

Twist Drill w Tip 2 × 7–15 mm . . . . . . . . . . . . . . . . . .32297 . . . . . .6, 12, 30, 32, 34<br />

Twist Drill w Tip 2 × 10–18 mm . . . . . . . . . . . . . . . . .32299 . . . . . .6, 12, 30, 32, 34<br />

Twist Step Drill 2.4/2.8 7–10 mm . . . . . . . . . . . . . . . .32260 . . . . . .6, 13, 30, 32, 34<br />

Twist Step Drill 2.4/2.8 7–15 mm . . . . . . . . . . . . . . . .32261 . . . . . .6, 13, 30, 32, 34<br />

Twist Step Drill 2.4/2.8 10–18 mm . . . . . . . . . . . . . . .32262 . . . . . .6, 13, 30, 32, 34<br />

Twist Step Drill 3.2/3.6 7–10 mm . . . . . . . . . . . . . . . .32263 . . . . . . . . .6, 30, 32, 34<br />

Twist Step Drill 3.2/3.6 7–15 mm . . . . . . . . . . . . . . . .32264 . . . . . . . . .6, 30, 32, 34<br />

Twist Step Drill 3.2/3.6 10–18 mm . . . . . . . . . . . . . . .32265 . . . . . . . . .6, 30, 32, 34<br />

Twist Step Drill 3.8/4.2 7–10 mm . . . . . . . . . . . . . . . .32275 . . . . . . . . .6, 30, 32, 34<br />

Twist Step Drill 3.8/4.2 7–15 mm . . . . . . . . . . . . . . . .32276 . . . . . . . . .6, 30, 32, 34<br />

Twist Step Drill 3.8/4.2 10–18 mm . . . . . . . . . . . . . . .32277 . . . . . . . . .6, 30, 32, 34<br />

E<br />

Precision Drill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33071 . . . . . . . . .14,30, 32, 34<br />

Esthetic Abutment<br />

Esthetic Abutment Bmk Syst NP 2 mm . . . . . . . . . . . . .32396 . . . . . . . . . . . . . .21, 36<br />

Esthetic Abutment Bmk Syst RP 1 mm . . . . . . . . . . . . .32397 . . . . . . . . . . . . . .21, 36<br />

Esthetic Abutment Bmk Syst RP 3 mm . . . . . . . . . . . . .32399 . . . . . . . . . . . . . .21, 36<br />

Esthetic Abutment Bmk Syst WP 1 mm . . . . . . . . . . . .32398 . . . . . . . . . . . . . .21, 36<br />

15° Esthetic Abutment<br />

15º Esthetic Abutment Bmk Syst NP 2 mm . . . . . . . . .32400 . . . . . . . . . . . . . . . . .36<br />

15º Esthetic Abutment Bmk Syst RP 1 mm . . . . . . . . . .32401 . . . . . . . . . . . . . . . . .36<br />

15º Esthetic Abutment Bmk Syst RP 3 mm . . . . . . . . . .32403 . . . . . . . . . . . . . . . . .36<br />

15º Esthetic Abutment Bmk Syst WP 1 mm . . . . . . . . .32402 . . . . . . . . . . . . . . . . .36<br />

H<br />

Healing Abutment (Abutment di Guarigione)<br />

Healing Abutment Bmk Syst NP ∅ 4 × 3 mm . . . . . . . .28990 . . . . . . . . . . . . . .31, 35<br />

Healing Abutment Bmk Syst NP ∅ 4 × 4 mm . . . . . . . .28991 . . . . . . . . . . . . . .31, 35<br />

Healing Abutment Bmk Syst NP ∅ 4 × 5 mm . . . . . . . .28992 . . . . . . . . . . . . . .31, 35<br />

Healing Abutment Bmk Syst NP ∅ 5 × 3 mm . . . . . . . .28993 . . . . . . . . . . . . . .31, 35<br />

Healing Abutment Bmk Syst NP ∅ 5 × 4 mm . . . . . . . .28994 . . . . . . . . . . . . . .31, 35<br />

Healing Abutment Bmk Syst NP ∅ 5 × 5 mm . . . . . . . .28995 . . . . . . . . . . . . . .31, 35<br />

Healing Abutment Bmk Syst RP ∅ 5 × 3 mm . . . . . . . .29137 . . . . . . . . . . . . . .31, 35<br />

Healing Abutment Bmk Syst RP ∅ 5 × 4 mm . . . . . . . .29138 . . . . . . . . . . . . . .31, 35<br />

Healing Abutment Bmk Syst RP ∅ 5 × 5 mm . . . . . . . .29139 . . . . . . . . . . . . . .31, 35<br />

Healing Abutment Bmk Syst RP ∅ 5 × 7 mm . . . . . . . .29140 . . . . . . . . . . . . . .31, 35<br />

Healing Abutment Bmk Syst WP ∅ 6 × 3 mm . . . . . . . .29141 . . . . . . . . . . . . . .33, 35<br />

Healing Abutment Bmk Syst WP ∅ 6 × 4 mm . . . . . . . .29142 . . . . . . . . . . . . . .33, 35<br />

Healing Abutment Bmk Syst WP ∅ 6 × 5 mm . . . . . . . .29143 . . . . . . . . . . . . . .33, 35<br />

I<br />

Immediate Temporary Abutment<br />

Immediate Temp Abutm Brånemark System ® NP . . . . .31643 . . . . . . . . . . . . . .17, 36<br />

Immediate Temp Abutm Brånemark System ® RP . . . . .31644 . . . . . . . . . . . . . .17, 36<br />

Immediate Temp Abutm Brånemark System ® WP . . . . .31655 . . . . . . . . . . . . . .17, 36<br />

Implant Driver (Driver per Impianto)<br />

Implant Driver Bmk Syst NP 26 mm . . . . . . . . . . . . . . .29126 . . . . . . . . . . . . . .31, 35<br />

Implant Driver Bmk Syst NP 34 mm . . . . . . . . . . . . . . .29127 . . . . . . . . . . . . . .31, 35<br />

Implant Driver Bmk Syst RP 21 mm . . . . . . . . . . . . . . .29129 . . . . . . . . . . . . . .31, 35<br />

Implant Driver Bmk Syst RP 26 mm . . . . . . . . . . . . . . .29130 . . . . . . . . . . . . . .31, 35<br />

Implant Driver Bmk Syst RP 34 mm . . . . . . . . . . . . . . .29131 . . . . . . . . . . . . . .31, 35<br />

Implant Driver Bmk Syst WP 21 mm . . . . . . . . . . . . . .29134 . . . . . . . . . . . . . .33, 35<br />

Implant Driver Bmk Syst WP 26 mm . . . . . . . . . . . . . .29135 . . . . . . . . . . . . . .33, 35<br />

Impl Driver Wrench Adap Bmk Syst NP 21 mm . . . . . .29128 . . . . . . . . . . . . . . . . .15<br />

Impl Driver Wrench Adap Bmk Syst RP 12 mm . . . . . .29132 . . . . . . . . . . . . . . . . .15<br />

Impl Driver Wrench Adap Bmk Syst RP 21 mm . . . . . .29133 . . . . . . . . . . . . . . . . .15<br />

Impl Driver Wrench Adap Bmk Syst WP 12 mm . . . . . .29136 . . . . . . . . . . . . . . . . .15<br />

Implant Sleeve Holder . . . . . . . . . . . . . . . . . . . . . . . . .29543 . . . . . . . . . . . . . . . . .37<br />

Implants (Impianti)<br />

<strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 10 mm . . . . . . . . . . . . .33123 . . . . . . . . . . . .9, 30, 34<br />

<strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 11.5 mm . . . . . . . . . . . .33124 . . . . . . . . . . . .9, 30, 34<br />

<strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 13 mm . . . . . . . . . . . . .33125 . . . . . . . . . . . .9, 30, 34<br />

<strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 15 mm . . . . . . . . . . . . .33126 . . . . . . . . . . . .9, 30, 34<br />

<strong>NOBELSPEEDY</strong> Shorty RP ∅ 4 . . . . . . . . . . . . . . . . . . . . .32146 . . . . . . . . . . . .9, 30, 34<br />

<strong>NOBELSPEEDY</strong> Groovy RP 4 × 8.5 mm . . . . . . . . . . . . . .32147 . . . . . . . . . . . .9, 30, 34<br />

<strong>NOBELSPEEDY</strong> Groovy RP 4 × 10 mm . . . . . . . . . . . . . . .32148 . . . . . . . . . . . .9, 30, 34<br />

<strong>NOBELSPEEDY</strong> Groovy RP 4 × 11.5 mm . . . . . . . . . . . . .32149 . . . . . . . . . . . .9, 30, 34<br />

<strong>NOBELSPEEDY</strong> Groovy RP 4 × 13 mm . . . . . . . . . . . . . . .32150 . . . . . . . . . . . .9, 30, 34<br />

<strong>NOBELSPEEDY</strong> Groovy RP 4 × 15 mm . . . . . . . . . . . . . . .32151 . . . . . . . . . . . .9, 30, 34<br />

<strong>NOBELSPEEDY</strong> Groovy RP 4 × 18 mm . . . . . . . . . . . . . . .32152 . . . . . . . . . . . .9, 30, 34<br />

<strong>NOBELSPEEDY</strong> Shorty WP ∅ 5 . . . . . . . . . . . . . . . . . . . . .32153 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 5 × 8.5 mm . . . . . . . . . . . . . .32154 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 5 × 10 mm . . . . . . . . . . . . . .32155 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 5 × 11.5 mm . . . . . . . . . . . . .32156 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 5 × 13 mm . . . . . . . . . . . . . .32157 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 5 × 15 mm . . . . . . . . . . . . . .32158 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 5 × 18 mm . . . . . . . . . . . . . .32159 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Shorty WP ∅ 6 . . . . . . . . . . . . . . . . . . . . .32139 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 6 × 8.5 mm . . . . . . . . . . . . . .32140 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 6 × 10 mm . . . . . . . . . . . . . .32141 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 6 × 11.5 mm . . . . . . . . . . . . .32142 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 6 × 13 mm . . . . . . . . . . . . . .32143 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 6 × 15 mm . . . . . . . . . . . . . .32144 . . . . . . . . . . . .9, 32, 34<br />

<strong>NOBELSPEEDY</strong> Groovy WP 6 × 18 mm . . . . . . . . . . . . . .32145 . . . . . . . . . . . .9, 32, 34<br />

K<br />

Kits<br />

Brånemark System ® Second Stage Surgery Kit . . . . . . .32308 . . . . . . . . . . .20, 25, 37<br />

Brånemark System ® Second Stage Surgery Kit Box . . .32315 . . . . . . . . . . .20, 25, 37<br />

Brånemark System ® Surgery Kit Box . . . . . . . . . . . . . .32312 . . . . . . . . . . . .3, 24, 37<br />

Brånemark System ® Surgery Kit . . . . . . . . . . . . . . . . . .32302 . . . . . . . . . . . .3, 24, 37<br />

<strong>Nobel</strong> <strong>Biocare</strong> ® Flapless Surgery Kit . . . . . . . . . . . . . . .32304 . . . . . . . . . . . .3, 25, 37<br />

<strong>Nobel</strong> <strong>Biocare</strong> ® Flapless Surgery Kit Box . . . . . . . . . . .32317 . . . . . . . . . . . .3, 25, 37<br />

<strong>Nobel</strong> <strong>Biocare</strong> ® Osteotome Kit . . . . . . . . . . . . . . . . . . .32321 . . . . . . . . . . . . . .27, 37<br />

Prosthetic Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32309 . . . . . . . . . . . .3, 25, 37<br />

38


elenco prodotti<br />

M<br />

Manual Torque Wrench<br />

Brånemark System ® Man Tor Wrench Adapt Surg . . . .32111 . . . . . . . . . . . . . .26, 37<br />

Brånemark System ® Man Tor Wrench Surgical . . . . . . .32110 . . . . . . . . . . .15, 26, 37<br />

Manual Torque Wrench Adapter Prosthetic . . . . . . . . .29167 . . . . . . . . . . .18, 26, 37<br />

Manual Torque Wrench Prosthetic . . . . . . . . . . . . . . .29165 . . . . . . . .19, 25, 26, 37<br />

S<br />

Screwdriver (Cacciaviti)<br />

Screwdriver Manual Unigrip 20 mm . . . . . . . . . . . . .29148 . . . . . . . . . . . . . .20, 36<br />

Screwdriver Manual Unigrip 28 mm . . . . . . . . . . . . .29149 . . . . . . . . . . . . . .20, 36<br />

Screwdriver Manual Unigrip 36 mm . . . . . . . . . . . . .29150 . . . . . . . . . . . . . .20, 36<br />

Screwdriver Machine Unigrip 20 mm . . . . . . . . . . . .29151 . . . . . . . . . . .19, 25, 36<br />

Screwdriver Machine Unigrip 25 mm . . . . . . . . . . . .29152 . . . . . . . . . . .19, 25, 36<br />

Screwdriver Machine Unigrip 30 mm . . . . . . . . . . . .29153 . . . . . . . . . . .19, 25, 36<br />

Screwdriver Machine Unigrip 35 mm . . . . . . . . . . . .29154 . . . . . . . . . . .19, 25, 36<br />

Screw Taps (Maschiatori)<br />

Screw Tap NP 10–15 mm . . . . . . . . . . . . . . . . . . . . . .32289 . . . . . . . . . . .14, 31, 35<br />

Screw Tap RP ∅ 4 7–13 mm . . . . . . . . . . . . . . . . . . . .33072 . . . . . . . . . . .14, 31, 35<br />

Screw Tap RP ∅ 4 7–18 mm . . . . . . . . . . . . . . . . . . . .33073 . . . . . . . . . . .14, 31, 35<br />

Screw Tap WP ∅ 5 7–13 mm . . . . . . . . . . . . . . . . . . . .32292 . . . . . . . . . . .14, 33, 35<br />

Screw Tap WP ∅ 5 7–18 mm . . . . . . . . . . . . . . . . . . . .32293 . . . . . . . . . . .14, 33, 35<br />

Screw Tap NobRpl 6.0/Bmk Syst WP ∅ 6 7–13 mm . . .32294 . . . . . . . . . . .14, 33, 35<br />

Screw Tap NobRpl 6.0/Bmk Syst WP ∅ 6 7–18 mm . . .32295 . . . . . . . . . . .14, 33, 35<br />

Soft Tissue Punch (Bisturi Circolare per Tessuti Molli)<br />

Soft Tissue Punch ∅ 4.1 mm, 5-pack . . . . . . . . . . . . .32Z2000 . . . . . . . . . . . .20, 37<br />

Soft Tissue Punch ∅ 5.2 mm, 5-pack . . . . . . . . . . . .32Z2002 . . . . . . . . . . . .20, 37<br />

Soft Tissue Punch ∅ 6.2 mm, 5-pack . . . . . . . . . . . . .32Z2004 . . . . . . . . . . . .20, 37<br />

T<br />

Temporary Abutments Non-Eng (Abutment Provvisori Non-antirotazionali)<br />

Temporary Abutment Non-Engaging<br />

Brånemark System ® NP . . . . . . . . . . . . . . . . . . . . . . . . .29029 . . . . . . . . . . . . . . . . .18<br />

Temporary Abutment Non-Engaging<br />

Brånemark System ® RP . . . . . . . . . . . . . . . . . . . . . . . . .29031 . . . . . . . . . . . . . . . . .18<br />

Temporary Abutment Non-Engaging<br />

Brånemark System ® WP . . . . . . . . . . . . . . . . . . . . . . . .29033 . . . . . . . . . . . . . . . . .18<br />

Tissue Punch (Bisturi Circolare)<br />

Tissue Punch NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29628 . . . . . . . . . . .11, 25, 37<br />

Tissue Punch RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29629 . . . . . . . . . . .11, 25, 37<br />

Tissue Punch WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29630 . . . . . . . . . . .11, 25, 37<br />

Tissue Punch 6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32672 . . . . . . . . . . .11, 25, 37<br />

Tissue Punch Guide (Guida per Bisturi Circolare)<br />

Tissue Punch Guide NP . . . . . . . . . . . . . . . . . . . . . . . .29631 . . . . . . . . . . .11, 25, 37<br />

Tissue Punch Guide RP . . . . . . . . . . . . . . . . . . . . . . . . .29632 . . . . . . . . . . .11, 25, 37<br />

Tissue Punch Guide WP . . . . . . . . . . . . . . . . . . . . . . . .29633 . . . . . . . . . . .11, 25, 37<br />

Tissue Punch Guide 6.0 . . . . . . . . . . . . . . . . . . . . . . .32673 . . . . . . . . . . .11, 25, 37<br />

39


40<br />

elenco prodotti<br />

Indice in ordine di numero di articolo<br />

Articolo Descrizione Pagina<br />

28977 . . . . .Bone Mill Brånemark System ® NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25, 37<br />

28978 . . . . .Bone Mill Brånemark System ® RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25, 37<br />

28979 . . . . .Bone Mill Brånemark System ® WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25, 37<br />

28980 . . . . .Cover Screw Mill Brånemark System ® NP . . . . . . . . . . . . . . . . . . . . .25, 29, 37<br />

28981 . . . . .Cover Screw Mill Brånemark System ® RP . . . . . . . . . . . . . . . . . . . . .25, 29, 37<br />

28982 . . . . .Cover Screw Mill Brånemark System ® WP . . . . . . . . . . . . . . . . . . . .25, 29, 37<br />

28986 . . . . .Cover Screw Brånemark System ® NP . . . . . . . . . . . . . . . . . . . . . . . . . . .16, 36<br />

28987 . . . . .Cover Screw Brånemark System ® RP . . . . . . . . . . . . . . . . . . . . . . . . . . .16, 36<br />

28988 . . . . .Cover Screw Brånemark System ® WP . . . . . . . . . . . . . . . . . . . . . . . . . . .16, 36<br />

28990 . . . . .Healing Abutment Bmk Syst NP ∅ 4 × 3 mm . . . . . . . . . . . . . . . . . . . .31, 35<br />

28991 . . . . .Healing Abutment Bmk Syst NP ∅ 4 × 4 mm . . . . . . . . . . . . . . . . . . . .31, 35<br />

28992 . . . . .Healing Abutment Bmk Syst NP ∅ 4 × 5 mm . . . . . . . . . . . . . . . . . . . .31, 35<br />

28993 . . . . .Healing Abutment Bmk Syst NP ∅ 5 × 3 mm . . . . . . . . . . . . . . . . . . . .31, 35<br />

28994 . . . . .Healing Abutment Bmk Syst NP ∅ 5 × 4 mm . . . . . . . . . . . . . . . . . . . .31, 35<br />

28995 . . . . .Healing Abutment Bmk Syst NP ∅ 5 × 5 mm . . . . . . . . . . . . . . . . . . . .31, 35<br />

29029 . . . . .Temporary Abutment Non-Engaging Brånemark System ® NP . . . . . . . . . . .18<br />

29031 . . . . .Temporary Abutment Non-Engaging Brånemark System ® RP . . . . . . . . . . . .18<br />

29033 . . . . .Temporary Abutment Non-Engaging Brånemark System ® WP . . . . . . . . . . .18<br />

29126 . . . . .Implant Driver Bmk Syst NP 26 mm . . . . . . . . . . . . . . . . . . . . . . . . . . .31, 35<br />

29127 . . . . .Implant Driver Bmk Syst NP 34 mm . . . . . . . . . . . . . . . . . . . . . . . . . . .31, 35<br />

29128 . . . . .Impl Driver Wrench Adap Bmk Syst NP 21 mm . . . . . . . . . . . . . . . . . . . . . .15<br />

29129 . . . . .Implant Driver Bmk Syst RP 21 mm . . . . . . . . . . . . . . . . . . . . . . . . . . .31, 35<br />

29130 . . . . .Implant Driver Bmk Syst RP 26 mm . . . . . . . . . . . . . . . . . . . . . . . . . . .31, 35<br />

29131 . . . . .Implant Driver Bmk Syst RP 34 mm . . . . . . . . . . . . . . . . . . . . . . . . . . .31, 35<br />

29132 . . . . .Impl Driver Wrench Adap Bmk Syst RP 12 mm . . . . . . . . . . . . . . . . . . . . . .15<br />

29133 . . . . .Impl Driver Wrench Adap Bmk Syst RP 21 mm . . . . . . . . . . . . . . . . . . . . . .15<br />

29134 . . . . .Implant Driver Bmk Syst WP 21 mm . . . . . . . . . . . . . . . . . . . . . . . . . . .33, 35<br />

29135 . . . . .Implant Driver Bmk Syst WP 26 mm . . . . . . . . . . . . . . . . . . . . . . . . . . .33, 35<br />

29136 . . . . .Impl Driver Wrench Adap Bmk Syst WP 12 mm . . . . . . . . . . . . . . . . . . . . . .15<br />

29137 . . . . .Healing Abutment Bmk Syst RP ∅ 5 × 3 mm . . . . . . . . . . . . . . . . . . . . .31, 35<br />

29138 . . . . .Healing Abutment Bmk Syst RP ∅ 5 × 4 mm . . . . . . . . . . . . . . . . . . . . .31, 35<br />

29139 . . . . .Healing Abutment Bmk Syst RP ∅ 5 × 5 mm . . . . . . . . . . . . . . . . . . . . .31, 35<br />

29140 . . . . .Healing Abutment Bmk Syst RP ∅ 5 × 7 mm . . . . . . . . . . . . . . . . . . . . .31, 35<br />

29141 . . . . .Healing Abutment Bmk Syst WP ∅ 6 × 3 mm . . . . . . . . . . . . . . . . . . . .33, 35<br />

29142 . . . . .Healing Abutment Bmk Syst WP ∅ 6 × 4 mm . . . . . . . . . . . . . . . . . . . .33, 35<br />

29143 . . . . .Healing Abutment Bmk Syst WP ∅ 6 × 5 mm . . . . . . . . . . . . . . . . . . . .33, 35<br />

29148 . . . . .Screwdriver Manual Unigrip 20 mm . . . . . . . . . . . . . . . . . . . . . . . . . .20, 36<br />

29149 . . . . .Screwdriver Manual Unigrip 28 mm . . . . . . . . . . . . . . . . . . . . . . . . . .20, 36<br />

29150 . . . . .Screwdriver Manual Unigrip 36 mm . . . . . . . . . . . . . . . . . . . . . . . . . .20, 36<br />

29151 . . . . .Screwdriver Machine Unigrip 20 mm . . . . . . . . . . . . . . . . . . . . . .19, 25, 36<br />

29152 . . . . .Screwdriver Machine Unigrip 25 mm . . . . . . . . . . . . . . . . . . . . . .19, 25, 36<br />

29153 . . . . .Screwdriver Machine Unigrip 30 mm . . . . . . . . . . . . . . . . . . . . . .19, 25, 36<br />

29154 . . . . .Screwdriver Machine Unigrip 35 mm . . . . . . . . . . . . . . . . . . . . . .19, 25, 36<br />

29164 . . . . .Drill Extension Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />

29165 . . . . .Manual Torque Wrench Prosthetic . . . . . . . . . . . . . . . . . . . . . .19, 25, 26, 37<br />

29167 . . . . .Manual Torque Wrench Adapter Prosthetic . . . . . . . . . . . . . . . . . .18, 26, 37<br />

29543 . . . . .Implant Sleeve Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />

29628 . . . . .Tissue Punch NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11, 25, 37<br />

29629 . . . . .Tissue Punch RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11, 25, 37<br />

29630 . . . . .Tissue Punch WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11, 25, 37<br />

29631 . . . . .Tissue Punch Guide NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11, 25, 37<br />

29632 . . . . .Tissue Punch Guide RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11, 25, 37<br />

29633 . . . . .Tissue Punch Guide WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11, 25, 37<br />

29634 . . . . .Drill Guide NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4, 25, 37<br />

29635 . . . . .Drill Guide RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4, 25, 37<br />

29636 . . . . .Drill Guide WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4, 25, 37<br />

31278 . . . . .Twist Drill 1.5 × 7–15 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

31643 . . . . .Immediate Temp Abutm Brånemark System ® NP . . . . . . . . . . . . . . . . . .17, 36<br />

31644 . . . . .Immediate Temp Abutm Brånemark System ® RP . . . . . . . . . . . . . . . . . .17, 36<br />

31655 . . . . .Immediate Temp Abutm Brånemark System ® WP . . . . . . . . . . . . . . . . . .17, 36<br />

32110 . . . . .Brånemark System ® Manual Torque Wrench Surgical . . . . . . . . . . .15, 26, 37<br />

32111 . . . . .Brånemark System ® Manual Torque Wrench Adapt Surg . . . . . . . . . . . .26, 37<br />

32112 . . . . .Direction Indicator ∅ 2/∅ 2.4–2.8mm . . . . . . . . . . . . . . . . . . . . . .12, 13, 37<br />

32139 . . . . .<strong>NOBELSPEEDY</strong> Shorty WP ∅ 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32140 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 6 × 8.5 mm . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32141 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 6 × 10 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32142 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 6 × 11.5 mm . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32143 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 6 × 13 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32144 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 6 × 15 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32145 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 6 × 18 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32146 . . . . .<strong>NOBELSPEEDY</strong> Shorty RP ∅ 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9, 30, 34<br />

32147 . . . . .<strong>NOBELSPEEDY</strong> Groovy RP 4 × 8.5 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 30, 34<br />

32148 . . . . .<strong>NOBELSPEEDY</strong> Groovy RP 4 × 10 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 30, 34<br />

32149 . . . . .<strong>NOBELSPEEDY</strong> Groovy RP 4 × 11.5 mm . . . . . . . . . . . . . . . . . . . . . . . .9, 30, 34<br />

32150 . . . . .<strong>NOBELSPEEDY</strong> Groovy RP 4 × 13 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 30, 34<br />

32151 . . . . .<strong>NOBELSPEEDY</strong> Groovy RP 4 × 15 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 30, 34<br />

32152 . . . . .<strong>NOBELSPEEDY</strong> Groovy RP 4 × 18 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 30, 34<br />

32153 . . . . .<strong>NOBELSPEEDY</strong> Shorty WP ∅ 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32154 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 5 × 8.5 mm . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32155 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 5 × 10 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32156 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 5 × 11.5 mm . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32157 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 5 × 13 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32158 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 5 × 15 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32159 . . . . .<strong>NOBELSPEEDY</strong> Groovy WP 5 × 18 mm . . . . . . . . . . . . . . . . . . . . . . . . .9, 32, 34<br />

32260 . . . . .Twist Step Drill 2.4/2.8 7–10 mm . . . . . . . . . . . . . . . . . . . .6, 13, 30, 32, 34<br />

32261 . . . . .Twist Step Drill 2.4/2.8 7–15 mm . . . . . . . . . . . . . . . . . . . .6, 13, 30, 32, 34<br />

32262 . . . . .Twist Step Drill 2.4/2.8 10–18 mm . . . . . . . . . . . . . . . . . . .6, 13, 30, 32, 34<br />

32263 . . . . .Twist Step Drill 3.2/3.6 7–10 mm . . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32264 . . . . .Twist Step Drill 3.2/3.6 7–15 mm . . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32265 . . . . .Twist Step Drill 3.2/3.6 10–18 mm . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32266 . . . . .Twist Drill 3 × 7–10 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32267 . . . . .Twist Drill 3 × 7–15 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32268 . . . . .Twist Drill 3 × 10–18 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32269 . . . . .Twist Drill 3.2 × 7–10 mm . . . . . . . . . . . . . . . . . . . . . . . . . .6, 13, 30, 32, 34<br />

32270 . . . . .Twist Drill 3.2 × 7–15 mm . . . . . . . . . . . . . . . . . . . . . . . . . .6, 13, 30, 32, 34<br />

32271 . . . . .Twist Drill 3.2 × 10–18 mm . . . . . . . . . . . . . . . . . . . . . . . . .6, 13, 30, 32, 34<br />

32272 . . . . .Twist Drill 3.4 × 7–10 mm . . . . . . . . . . . . . . . . . . . . . . . . . .6, 13, 30, 32, 34<br />

32273 . . . . .Twist Drill 3.4 × 7–15 mm . . . . . . . . . . . . . . . . . . . . . . . . . .6, 13, 30, 32, 34<br />

32274 . . . . .Twist Drill 3.4 × 10–18 mm . . . . . . . . . . . . . . . . . . . . . . . . .6, 13, 30, 32, 34<br />

32275 . . . . .Twist Step Drill 3.8/4.2 7–10 mm . . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32276 . . . . .Twist Step Drill 3.8/4.2 7–15 mm . . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32277 . . . . .Twist Step Drill 3.8/4.2 10–18 mm . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32278 . . . . .Twist Drill 5 × 7–10mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32279 . . . . .Twist Drill 5 × 7–15mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32280 . . . . .Twist Drill 5 × 10–18mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6, 30, 32, 34<br />

32281 . . . . .Brånemark System ® Counterbore NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31<br />

32283 . . . . .Brånemark System ® Counterbore RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31<br />

32285 . . . . .Brånemark System ® Counterbore WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33<br />

32289 . . . . .Screw Tap NP 10–15mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14, 31, 35<br />

32292 . . . . .Screw Tap WP ∅ 5 7–13 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14, 33, 35<br />

32293 . . . . .Screw Tap WP ∅ 5 7–18 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14, 33, 35<br />

32294 . . . . .Screw Tap NobRpl 6.0/Bmk Syst WP ∅ 6 7–13 mm . . . . . . . . . . . .14, 33, 35<br />

32295 . . . . .Screw Tap NobRpl 6.0/Bmk Syst WP ∅ 6 7–18 mm . . . . . . . . . . . .14, 33, 35<br />

32296 . . . . .Twist Drill w Tip 2 × 7–10 mm . . . . . . . . . . . . . . . . . . . . . . .6, 12, 30, 32, 34<br />

32297 . . . . .Twist Drill w Tip 2 × 7–15 mm . . . . . . . . . . . . . . . . . . . . . . .6, 12, 30, 32, 34<br />

32299 . . . . .Twist Drill w Tip 2 × 10–18 mm . . . . . . . . . . . . . . . . . . . . . .6, 12, 30, 32, 34<br />

32302 . . . . .Brånemark System ® Surgery Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . .3, 24, 37<br />

32304 . . . . .<strong>Nobel</strong> <strong>Biocare</strong> ® Flapless Surgery Kit . . . . . . . . . . . . . . . . . . . . . . . . .3, 25, 37<br />

32308 . . . . .Brånemark System ® Second Stage Surgery Kit . . . . . . . . . . . . . . . .20, 25, 37<br />

32309 . . . . .Prosthetic Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3, 25, 37<br />

32312 . . . . .Brånemark System ® Surgery Kit Box . . . . . . . . . . . . . . . . . . . . . . . . .3, 24, 37<br />

32315 . . . . .Brånemark System ® Second Stage Surgery Kit Box . . . . . . . . . . . . .20, 25, 37<br />

32317 . . . . .<strong>Nobel</strong> <strong>Biocare</strong> ® Flapless Surgery Kit Box . . . . . . . . . . . . . . . . . . . . . .3, 25, 37<br />

32321 . . . . .<strong>Nobel</strong> <strong>Biocare</strong> ® Osteotome Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27, 37<br />

32396 . . . . .Esthetic Abutment Bmk Syst NP 2 mm . . . . . . . . . . . . . . . . . . . . . . . . .21, 36<br />

32397 . . . . .Esthetic Abutment Bmk Syst RP 1 mm . . . . . . . . . . . . . . . . . . . . . . . . .21, 36<br />

32398 . . . . .Esthetic Abutment Bmk Syst WP 1 mm . . . . . . . . . . . . . . . . . . . . . . . . .21, 36<br />

32399 . . . . .Esthetic Abutment Bmk Syst RP 3 mm . . . . . . . . . . . . . . . . . . . . . . . . .21, 36<br />

32400 . . . . .15º Esthetic Abutment Bmk Syst NP 2 mm . . . . . . . . . . . . . . . . . . . . . . . . .36<br />

32401 . . . . .15º Esthetic Abutment Bmk Syst RP 1 mm . . . . . . . . . . . . . . . . . . . . . . . . .36<br />

32402 . . . . .15º Esthetic Abutment Bmk Syst WP 1 mm . . . . . . . . . . . . . . . . . . . . . . . . .36<br />

32403 . . . . .15º Esthetic Abutment Bmk Syst RP 3 mm . . . . . . . . . . . . . . . . . . . . . . . . .36<br />

32430 . . . . .Drill Stop Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 30, 32<br />

32672 . . . . .Tissue Punch 6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11, 25, 37<br />

32673 . . . . .Tissue Punch Guide 6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11, 25, 37<br />

32674 . . . . .Drill Guide 6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4, 25, 37<br />

32948 . . . . .Depth Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13, 37<br />

33062 . . . . .Drill Stop Kit Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 30, 32<br />

33063 . . . . .Drill Stop ∅ 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 30, 32<br />

33064 . . . . .Drill Stop ∅ 2.8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 30, 32<br />

33071 . . . . .Precision Drill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14,30, 32, 34<br />

33072 . . . . .Screw Tap RP ∅ 4 7–13 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14, 31, 35<br />

33073 . . . . .Screw Tap RP ∅ 4 7–18 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14, 31, 35<br />

33075 . . . . .Drill Stop ∅ 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 30, 32<br />

33077 . . . . .Drill Stop ∅ 3.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 30, 32<br />

33078 . . . . .Drill Stop ∅ 3.4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 30, 32<br />

33081 . . . . .Drill Stop ∅ 4.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 30, 32<br />

33084 . . . . .Drill Stop ∅ 3.6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 30, 32<br />

33097 . . . . .Brånemark System ® /<strong>NOBELSPEEDY</strong> Radiographic Template . . . . . . . . . . .23, 38<br />

33123 . . . . .<strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 10 mm . . . . . . . . . . . . . . . . . . . . . . . .9, 30, 34<br />

33124 . . . . .<strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 11.5 mm . . . . . . . . . . . . . . . . . . . . . .9, 30, 34<br />

33125 . . . . .<strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 13 mm . . . . . . . . . . . . . . . . . . . . . . . .9, 30, 34<br />

33126 . . . . .<strong>NOBELSPEEDY</strong> Groovy NP 3.3 × 15 mm . . . . . . . . . . . . . . . . . . . . . . . .9, 30, 34<br />

33129 . . . . .Brånemark System ® Wall chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />

32Z2000 . . .Soft Tissue Punch ∅ 4.1 mm, 5-pack . . . . . . . . . . . . . . . . . . . . . . . . . .20, 37<br />

32Z2002 . . .Soft Tissue Punch ∅ 5.2 mm, 5-pack . . . . . . . . . . . . . . . . . . . . . . . . . .20, 37<br />

32Z2004 . . .Soft Tissue Punch ∅ 6.2 mm, 5-pack . . . . . . . . . . . . . . . . . . . . . . . . . .20, 37<br />

DIB 097-0 . .Cover Screw Driver Bmk Syst Hexagon . . . . . . . . . . . . . . . . . . . . . . . .20, 25


le nostre credenziali sono<br />

Risultati<br />

• Eredi e sviluppatori del lavoro del Professor<br />

Brånemark – fondatore dell’implantologia<br />

moderna. Leader mondiali del settore<br />

• Fornitori delle soluzioni più complete e<br />

flessibili per corone, ponti e impianti a livello<br />

internazionale<br />

• Creatori dell’esclusivo materiale biocompatibile<br />

TiUnite ® per una osteointegrazione ottimale,<br />

Immediate Function e Soft Tissue<br />

Integration <br />

• Creatori dell’odontoiatria CAD/CAM<br />

• Creatori dell’esclusivo Procera ® System – una<br />

procedura completa, dalla progettazione 3D<br />

alla chirurgia guidata fino alla protesi personalizzata<br />

in ceramica<br />

• Approvazione FDA per Immediate Function <br />

(3.0 e Zygoma esclusi)<br />

• Approvazione FDA per Teeth In An Hour <br />

nel 2004<br />

Qualità<br />

• Non è stata rilevata alcuna non conformità<br />

nel controllo FDA del 2004 delle unità di<br />

produzione di <strong>Nobel</strong> <strong>Biocare</strong> a Göteborg,<br />

Karlskoga e Stoccolma<br />

la vostra sicurezza<br />

Ricerca<br />

• Collaborazione formale con più di 50 istituzioni<br />

accademiche e 600 scienziati indipendenti<br />

in tutto il mondo<br />

• Numero di studi clinici su carico immediato<br />

o precoce superiore a quello di tutti gli altri<br />

concorrenti (Medline Febbraio 2005)<br />

• Numero di studi clinici prospettici con followup<br />

minimo di 5 anni superiore a quello di<br />

tutti gli altri concorrenti (Berglund et al 2002)<br />

Supporto<br />

<strong>Nobel</strong> <strong>Biocare</strong> è attenta all’ambiente e tutte le unità<br />

di produzione sono certificate in conformità all’Environmental<br />

Management System ISO 14001.<br />

• 165.000 clienti addestrati da 1.985 professionisti<br />

del settore in 37 paesi e in 19 lingue,<br />

nel 2004<br />

• Proprie organizzazioni di vendita con personale<br />

locale <strong>Nobel</strong> <strong>Biocare</strong> in 29 Paesi<br />

• Sito Web commerciale in 8 lingue, con<br />

servizio online completo per la fornitura di<br />

tutti i prodotti e almeno 500 corsi disponibili<br />

in qualsiasi momento<br />

15134 Lot “IT 0506” Stampato in Svezia. © <strong>Nobel</strong> <strong>Biocare</strong> Services AG, 2005.<br />

<strong>Nobel</strong> <strong>Biocare</strong>, il tipo di logo <strong>Nobel</strong> <strong>Biocare</strong> e tutti gli altri marchi di fabbrica usati in questo documento sono, salvo diversa dichiarazione o evidenza dal contesto in un caso specifico, marchi di fabbrica del gruppo <strong>Nobel</strong> <strong>Biocare</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!