WARNING<br />
- Before all interventions, make sure that both units have been disconnected from the electricity supply.<br />
- Make sure the systems to which the appliance should be connected comply with the applicable norms in force.<br />
CHECKS WITHOUT THE USE OF TOOLS OR INSTRUMENTS<br />
Operation in Cooling mode - Visual checks on the Internal Unit<br />
Problem<br />
1 - Frost forms on the Internal Unit’s<br />
heat exchanger.<br />
2 - No condensation forms.<br />
3 - The compressor works but there<br />
is little cooling.<br />
4 - The air temperature is low, but<br />
there is little cooling.<br />
5 - The compressor stays still.<br />
6 - The appliance comes to a stop<br />
after a few minutes of operation.<br />
Problem<br />
Check<br />
1.A - Brina solo sulla parte bassa dello scambiatore:<br />
perdita di gas.<br />
1.B - Brina su tutto lo scambiatore: il filtro dell'aria<br />
è intasato.<br />
La temperatura ambiente è bassa<br />
(< 20° C).<br />
2.A - If the Internal Unit’s heat exchanger<br />
remains dry and the electricity consumption is<br />
much lower than the rated value, then there is<br />
a leak.<br />
3.A - The External Unit’s heat exchanger is<br />
clogged or covered: the heat exchange is poor.<br />
3.B - The fins on the External Unit’s heat<br />
exchanger are bent.<br />
4.A - The Internal Unit filter is clogged.<br />
4.B - The air recirculates in the Internal Unit.<br />
4.C - The appliance is not the right size or there<br />
is an overload (e.g. heat sources, overcrowding,<br />
etc.).<br />
5.A - The compressor is very hot: thermal protection.<br />
6.A - The Internal Unit fan is out of order.<br />
TROUBLESHOOTING - Electrical part -<br />
Check<br />
Intervention<br />
· Find the leak and recharge.<br />
· Clean the air filter.<br />
Unplug the appliance and switch off the<br />
dedicated switch before cleaning. (risk of<br />
electrocution)<br />
· Check the room temp.<br />
· Find the leak<br />
· Replace the heat exchanger<br />
· Clear the External Unit’s heat<br />
exchanger.<br />
· Straighten the fins on the external<br />
heat exchanger.<br />
· Clean the filter.<br />
· Encourage the free circulation of air.<br />
· Replace the appliance or remove<br />
the overload.<br />
· Wait for the temperature to drop.<br />
· Replace the motor.<br />
Only use original spare parts.<br />
Intervention<br />
1 - The appliance gives no sign of<br />
life (no LEDs lit, no beeps sounded),<br />
not even when you press the AUTO<br />
(or TEST) button on the Internal<br />
Unit.<br />
2 - The remote control does not<br />
work or only works at a close distance.<br />
1.A - Check whether there has been a<br />
power failure.<br />
1.B - Check whether the plug is inserted<br />
fully in the socket in the wall.<br />
1.C - Check whether the automatic switch<br />
has blown.<br />
1.D - Check whether the selector has been<br />
set to STOP.<br />
2.A - Check whether the batteries are low.<br />
2.B - Check whether there are any obstacles<br />
(curtains or ornaments) between the<br />
remote control and the air conditioning unit.<br />
2.C - Check whether the distance between<br />
the remote control and the unit is too far.<br />
· Restore the power supply and the<br />
correct connections.<br />
· Plug the appliance in fully.<br />
· Reset the automatic switch.<br />
· Set the selector to another function.<br />
· Replace the batteries.<br />
· Remove all obstacles.<br />
· Move closer to the air conditioning<br />
unit.<br />
38