WARNING<br />

- Before all interventions, make sure that both units have been disconnected from the electricity supply.<br />

- Make sure the systems to which the appliance should be connected comply with the applicable norms in force.<br />

CHECKS WITHOUT THE USE OF TOOLS OR INSTRUMENTS<br />

Operation in Cooling mode - Visual checks on the Internal Unit<br />

Problem<br />

1 - Frost forms on the Internal Unit’s<br />

heat exchanger.<br />

2 - No condensation forms.<br />

3 - The compressor works but there<br />

is little cooling.<br />

4 - The air temperature is low, but<br />

there is little cooling.<br />

5 - The compressor stays still.<br />

6 - The appliance comes to a stop<br />

after a few minutes of operation.<br />

Problem<br />

Check<br />

1.A - Brina solo sulla parte bassa dello scambiatore:<br />

perdita di gas.<br />

1.B - Brina su tutto lo scambiatore: il filtro dell'aria<br />

è intasato.<br />

La temperatura ambiente è bassa<br />

(< 20° C).<br />

2.A - If the Internal Unit’s heat exchanger<br />

remains dry and the electricity consumption is<br />

much lower than the rated value, then there is<br />

a leak.<br />

3.A - The External Unit’s heat exchanger is<br />

clogged or covered: the heat exchange is poor.<br />

3.B - The fins on the External Unit’s heat<br />

exchanger are bent.<br />

4.A - The Internal Unit filter is clogged.<br />

4.B - The air recirculates in the Internal Unit.<br />

4.C - The appliance is not the right size or there<br />

is an overload (e.g. heat sources, overcrowding,<br />

etc.).<br />

5.A - The compressor is very hot: thermal protection.<br />

6.A - The Internal Unit fan is out of order.<br />

TROUBLESHOOTING - Electrical part -<br />

Check<br />

Intervention<br />

· Find the leak and recharge.<br />

· Clean the air filter.<br />

Unplug the appliance and switch off the<br />

dedicated switch before cleaning. (risk of<br />

electrocution)<br />

· Check the room temp.<br />

· Find the leak<br />

· Replace the heat exchanger<br />

· Clear the External Unit’s heat<br />

exchanger.<br />

· Straighten the fins on the external<br />

heat exchanger.<br />

· Clean the filter.<br />

· Encourage the free circulation of air.<br />

· Replace the appliance or remove<br />

the overload.<br />

· Wait for the temperature to drop.<br />

· Replace the motor.<br />

Only use original spare parts.<br />

Intervention<br />

1 - The appliance gives no sign of<br />

life (no LEDs lit, no beeps sounded),<br />

not even when you press the AUTO<br />

(or TEST) button on the Internal<br />

Unit.<br />

2 - The remote control does not<br />

work or only works at a close distance.<br />

1.A - Check whether there has been a<br />

power failure.<br />

1.B - Check whether the plug is inserted<br />

fully in the socket in the wall.<br />

1.C - Check whether the automatic switch<br />

has blown.<br />

1.D - Check whether the selector has been<br />

set to STOP.<br />

2.A - Check whether the batteries are low.<br />

2.B - Check whether there are any obstacles<br />

(curtains or ornaments) between the<br />

remote control and the air conditioning unit.<br />

2.C - Check whether the distance between<br />

the remote control and the unit is too far.<br />

· Restore the power supply and the<br />

correct connections.<br />

· Plug the appliance in fully.<br />

· Reset the automatic switch.<br />

· Set the selector to another function.<br />

· Replace the batteries.<br />

· Remove all obstacles.<br />

· Move closer to the air conditioning<br />

unit.<br />