3<br />

ELECTRICAL CONNECTIONS<br />

ATTENZIONE:<br />

- Before making any electrical connections, make sure that both units have been disconnected from the electricity<br />

supply.<br />

- Make sure the systems to which the appliance should be connected comply with the applicable norms in force.<br />

- Only use the cables provided with the appliance or, in the event of replacement due to damage, only use cables with<br />

a suitable section.<br />

- Allow some extra length on the connection cables to allow for future maintenance.<br />

- Never connect the power supply cable by cutting it in half as this could cause a blaze.<br />

3.1 HOW TO ACCESS THE EXTERNAL UNIT TERMINAL BOARD<br />

1. Remove the terminal board cover.<br />

2. Connect the connector of the signal cable (only featured on the<br />

heat pump models).<br />

3. Connect the wires from the power supply cable to the terminal<br />

board according to the wiring diagrams illustrated below.<br />

4. Fasten the cables using the cable clamp.<br />

5. Put the cover back in place.<br />

EXTERNAL UNIT<br />

power supply cable<br />

cable clamp<br />

cover<br />

sensor cable<br />

NOTE: remove the sheath from both ends of the connection wires in the<br />

power supply cable as illustrated in the figure. Make sure the connection wires<br />

do not come into contact with the piping or other metal parts.<br />

70 mm<br />

15 mm<br />

31