20.10.2014 Views

CTU 24 - Ungaro srl

CTU 24 - Ungaro srl

CTU 24 - Ungaro srl

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

sc. ctu <strong>24</strong> - 170409<br />

<strong>CTU</strong> <strong>24</strong><br />

Scheda<br />

Tecnica<br />

<strong>Ungaro</strong> <strong>srl</strong><br />

Via S.Mango2<br />

88040 San Mango d’Aquino (CZ)<br />

0968.96484 0968.926838 fax 0968.926635<br />

info@ungaro<strong>srl</strong>.com - www.ungaro<strong>srl</strong>.com


710<br />

1220<br />

235<br />

384<br />

355<br />

uscita fumi<br />

(fume exit)<br />

entrata aria<br />

(air entrance)<br />

Ø80<br />

237<br />

Ø50<br />

730<br />

130<br />

<strong>24</strong>2<br />

65<br />

115<br />

65<br />

<strong>24</strong>2<br />

2<br />

mandata impianto 3/4"<br />

(system entrance 3/4")<br />

ritorno impianto 3/4"<br />

(system return 3/4")<br />

calda sanitaria 1/2" fredda sanitaria 1/2"<br />

(hot sanitary 1/2") (cold sanitary 1/2")


sc. ctu <strong>24</strong> - <strong>24</strong>0708<br />

Stufa a pellet modello/<br />

pellet stove model :<br />

<strong>CTU</strong> <strong>24</strong><br />

Potenza termochimica max / Heat Imput max kW <strong>24</strong>,8<br />

Potenza termochimica min / Heat Imput min kW 9,4<br />

Potenza nominale max / Nominal heat max kW 22,5<br />

Potenza nominale min / Nominal heat min kW 8,6<br />

Rendimento max / Efficiency max % 90,7<br />

Rendimento min / Efficiency min % 91,6<br />

Potenza all’acqua max / Water heat output max kW 21,5<br />

Potenza all’acqua min / Water heat output min kW 6,7<br />

Potenza all’aria max / Space heat output max kW /<br />

Potenza all’aria min / Space heat output min kW /<br />

Capacità serbatoio / Tank capacity Kg 46,0<br />

Consumo orario pellet max / Hourly pellet consumption max Kg 5,0<br />

Consumo orario pellet min / Hourly pellet consumption min Kg 1,9<br />

Autonomia di lavoro max / Working autonomy max h <strong>24</strong>,5<br />

Autonomia di lavoro min / Working autonomy min h 9,3<br />

Volume riscaldabile (Kcal 32 x m ³) / Heating volume (Kcal 32 x m³) m³ 600,0<br />

Ø uscita scarico fumi pellet / Ø pellet smoke outlet mm 80,0<br />

Tiraggio max / Draft max mbar 12,0<br />

Tiraggio min / Draft min mbar 10,0<br />

Ø entrata aria comburente pellet / Ø pellet primary air inlet mm 60,0<br />

Contenuto acqua in caldaia / Boiler water content l 14,0<br />

Prevalenza cricolatore / Water circulator prevalence m 6,0<br />

Pressione d'utilizzo / Pressure on working mode bar 0,8 / 1,2<br />

Dimensione vaso d'espansione / Expansion vase size l 8,0<br />

Produzione acqua sanitaria (optional) / Hot drinking water production (option) lt/min 10,0<br />

Tensione d'alimentazione / Working voltage supply<br />

V<br />

220<br />

V/50Hz<br />

Assorbimento elettrico in fase lavoro / Electric absorbment in working mode W 90 / 150<br />

Peso / Weight Kg 200<br />

Tiraggio min / Dra ft min mbar 10,0<br />

Prove eseguite usando come combustibile pellet di legno con potere calorifico pari a 4.9 kWh/kg.<br />

Tests done using wood pellet (as full) with heating power of 4.9 kWh/kg.<br />