26.03.2014 Views

THERMOLAST M - Kraiburg TPE

THERMOLAST M - Kraiburg TPE

THERMOLAST M - Kraiburg TPE

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>THERMOLAST</strong> ® M<br />

MT/CO – Materiali per il settore medicale e farmaceutico,<br />

adesione a PC, ABS, PC/ABS<br />

APPLICAZIONI POSSIBILI:<br />

Applicazioni per il settore medicale e<br />

farmaceutico<br />

ESEMPI DI APPLICAZIONI:<br />

guarnizioni<br />

valvole<br />

soft touch<br />

elementi di giunzioni flessibili<br />

membrane<br />

VANTAGGI OFFERTI DAL MATERIALE:<br />

Superato il test USP Class VI, USP 661<br />

e ISO 10993-4, -5, -10, -11<br />

Eccelente adesione a PC, ABS, PC/ABS<br />

Adatto all`estrusione<br />

Eccelenti caratteristiche mecaniche<br />

Sterilizabile (autoclave 134°C, gammaradiazione<br />

2x35 kGy, EtO)<br />

Il KRAIBURG <strong>TPE</strong> Medical Service Package è<br />

valido per questa serie (vede descrizione qui sotto)<br />

Serie MT/CO – medicale, adesione a materiali termoplastici polari<br />

Colore<br />

Durezza<br />

DIN 53505 / ISO 868<br />

Sh A<br />

Densitá<br />

DIN EN ISO 1183-1:2004<br />

g/cm³<br />

Resistenza alla trazione<br />

DIN 53504 / ISO 37<br />

N/mm²<br />

Allungamento a rottura<br />

DIN 53504 / ISO 37%<br />

Resistenza allo strappo<br />

ISO 34-1 Methode B (b)<br />

(Graves)<br />

N/mm<br />

Adesione a PC<br />

conforme al test Renault<br />

D41 1916 N/mm<br />

Adesione a ABS<br />

conforme al test Renault<br />

D41 1916 N/mm<br />

Adesione a PETG<br />

conforme al test Renault<br />

D41 1916 N/mm<br />

TM3ADT naturale 35 0.93 3.0 500 8 3.2 2.6 2.6<br />

TM4ADT naturale 40 0.94 3.5 500 8 4.4 3.7 4.7<br />

TM5ADT naturale 50 0.95 5.0 550 10 9.6 7.3 8.2<br />

TM6ADT naturale 60 0.96 6.0 550 12 10.5 8.7 10.3<br />

TM7ADT naturale 70 1.00 8.0 650 17 14.0 9.9 25.0<br />

Questa scheda informativa é tratta dal programma <strong>THERMOLAST</strong> ® . KRAIBURG <strong>TPE</strong> è a Vostra disposizione per consigliarVi il materiale più<br />

adatto alle Vostre applicazioni.<br />

Nota:<br />

Le informazioni contenute nel presente corrispondono al nostro livello di conoscenza al momento della pubblicazione. Non è escluso che queste<br />

ultime possano cambiare sulla scorta di ulteriori ricerche e studi. I nostri rapporti si basano su misurazioni effettuate su campioni e non esimono<br />

il cliente dalla responsabilità di condurre prove sui prodotti finiti al fine di stabilirne la idoneità. Di conseguenza, la KRAIBURG <strong>TPE</strong> non si<br />

assume alcuna responsabilità in relazione all´uso di queste informazioni.<br />

© 2013 by KRAIBURG <strong>TPE</strong> GmbH & Co. KG, 2013-04-11<br />

16<br />

KRAIBURG <strong>TPE</strong> GmbH & Co. KG<br />

Friedrich-Schmidt-Strasse 2 D-84478 Waldkraiburg GERMANY<br />

Salvo errori e/o omissioni<br />

La versione aggiornata si trova sul sito: www.kraiburg-tpe.com


<strong>THERMOLAST</strong> ® M<br />

Test dei materiali MT per il settore medicale e pharmaceutico<br />

USP class VI, USP 661, ISO 10993-4 hemolysis, indirect in human blood, ISO 10993-5<br />

TM3ADT<br />

cytotoxicity, ISO 10993-10 intracutaneous irritation, ISO 10993-11 acute system toxicity<br />

TM4ADT<br />

TM5ADT<br />

TM6ADT<br />

USP class VI, USP 661, ISO 10993-4 hemolysis, indirect in human blood, ISO 10993-5<br />

cytotoxicity, ISO 10993-10 intracutaneous irritation, ISO 10993-11 acute system toxicity<br />

USP class VI, USP 661, ISO 10993-4 hemolysis, indirect in human blood, ISO 10993-5<br />

cytotoxicity, ISO 10993-10 intracutaneous irritation, ISO 10993-11 acute system toxicity<br />

USP class VI, USP 661, ISO 10993-4 hemolysis, indirect in human blood, ISO 10993-5<br />

cytotoxicity, ISO 10993-10 intracutaneous irritation, ISO 10993-11 acute system toxicity<br />

TM7ADT USP class VI, USP 661, ISO 10993-4 hemolysis, indirect in human blood, ISO 10993-5<br />

cytotoxicity, ISO 10993-10 intracutaneous irritation, ISO 10993-11 acute system toxicity<br />

servizio speciale medicale <strong>THERMOLAST</strong> ® M:<br />

test di tutti i compound <strong>THERMOLAST</strong> ® M secondo le norme di base medicali e drug master file - costanza 100%<br />

delle ricette e procedure di produzione (adeguamento solo in caso di cambiamenti di legge) - almeno 24 mesi di<br />

avanzamento in caso di necessarie cambiamenti di ricette o procedure, con contemporanea certezza di consegne -<br />

produzione su macchine proprie per il settore medicale.<br />

Questa scheda informativa é tratta dal programma <strong>THERMOLAST</strong> ® . KRAIBURG <strong>TPE</strong> è a Vostra disposizione per consigliarVi il materiale più<br />

adatto alle Vostre applicazioni.<br />

Nota:<br />

Le informazioni contenute nel presente corrispondono al nostro livello di conoscenza al momento della pubblicazione. Non è escluso che queste<br />

ultime possano cambiare sulla scorta di ulteriori ricerche e studi. I nostri rapporti si basano su misurazioni effettuate su campioni e non esimono<br />

il cliente dalla responsabilità di condurre prove sui prodotti finiti al fine di stabilirne la idoneità. Di conseguenza, la KRAIBURG <strong>TPE</strong> non si<br />

assume alcuna responsabilità in relazione all´uso di queste informazioni.<br />

© 2013 by KRAIBURG <strong>TPE</strong> GmbH & Co. KG, 2013-04-11<br />

16<br />

KRAIBURG <strong>TPE</strong> GmbH & Co. KG<br />

Friedrich-Schmidt-Strasse 2 D-84478 Waldkraiburg GERMANY<br />

Salvo errori e/o omissioni<br />

La versione aggiornata si trova sul sito: www.kraiburg-tpe.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!