HKF 200 - Karcher
HKF 200 - Karcher
HKF 200 - Karcher
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Start up<br />
Electric drive<br />
Danger<br />
Risk of fatal injuries on account of electric<br />
voltage! Required electrical work must only<br />
be performed by an electrical specialist.<br />
– The socket must be secured through a<br />
wrong current protection switch with a<br />
triggering current of 30 mA.<br />
– This socket must be located close to the<br />
work station so that the plug can be<br />
pulled immediately in case of an emergency.<br />
– With a fixed power connection, a lockable<br />
main switch must be installed to<br />
completely separate it from the power<br />
supply.<br />
Electric drive 42 V and 400 V:<br />
Connect cable (4-core) to the threephase<br />
motor.<br />
Connect the motor cable on the power<br />
supply via a lockable main switch.<br />
Turn cleaning head on and check its rotation<br />
direction.<br />
The cleaning head must turn in the following<br />
direction when operated:<br />
Compressed air drive<br />
Warning<br />
In order to avoid damage to the compressed<br />
air drive by condensation wear and<br />
lack of lubrication, install a maintenance<br />
unit into the compressed air supply (order<br />
no. 6.610-020).<br />
This maintenance unit must be laid out as<br />
follows:<br />
– Air throughput of 500 l/min<br />
– Pressures up to 0.7 MPa<br />
The maintenance unit consists of:<br />
– Water separator<br />
– Pressure regulator with manometer<br />
– Proportional oiler<br />
Fill the proportional oiler with suitable lubrication<br />
oil by unscrewing the reservoir<br />
and filling it with lubricating oil (for oil<br />
type see "Care and Maintenance“).<br />
Connect compressed air hoses to the<br />
compressed air motor<br />
Note<br />
If the silencers are too small, the created<br />
backpressure of the exhaust air will cause<br />
an unstable run of the compressed air drive.<br />
Connect hoses to the exhaust air openings.<br />
Connect an air supply hose to connection<br />
no. 2.<br />
– Hose size for supply air: DN 6<br />
Connect exhaust air hoses to connection<br />
no. 1 and EXH.<br />
– Hose length: 1 -2 m<br />
– Hose size for exhaust air: DN 6<br />
Operation<br />
Danger<br />
Risk of injury on account of the escaping<br />
water jet that could be hot!<br />
– Only use the interior cleaner in closed<br />
containers.<br />
– Only insert the interior cleaner into a<br />
container or switch it into another container<br />
while the separate high pressure<br />
pump and internal drive are turned off.<br />
Place interior cleaner on top of container<br />
and secure if necessary.<br />
Connect the high pressure pump to the<br />
interior cleaner via a high pressure<br />
hose.<br />
Interior cleaners with electric drives:<br />
Switch on power supply.<br />
Interior cleaners with compressed air<br />
drives: Open the compressed air supply.<br />
Open the cleaning liquid supply.<br />
Switch on the separate high pressure<br />
pump.<br />
Shutting down<br />
Note<br />
Flush/rinse the interior cleaner for 30 seconds<br />
prior to shutting it off. This will avoid<br />
crusting and adhesion and thus a premature<br />
wear of the seals.<br />
Switch off the separate high pressure<br />
pump.<br />
Shut off the cleaning liquid supply.<br />
Interior cleaners with electric drives:<br />
Pull the power cord or shut off power<br />
supply.<br />
Interior cleaners with compressed air<br />
drives: Shut off the compressed air supply.<br />
Remove the interior cleaner from the<br />
container.<br />
Maintenance and care<br />
The basis for a safe operational plant is regular<br />
maintenance.<br />
Use only original parts of the manufacturer<br />
or part suggessted by him, such as<br />
– replacement and wear parts<br />
– Accessory parts<br />
– Fuel<br />
– Detergent<br />
Danger<br />
Risk of accident while working on the unit!<br />
During all tasks:<br />
Remove voltage from and secure high<br />
pressure pump at the main switch.<br />
Shut off the cleaning liquid supply.<br />
Interior cleaners with electric drives:<br />
Pull the power cord or shut off power<br />
supply.<br />
Interior cleaners with compressed air<br />
drives: Shut off the compressed air supply.<br />
Who may perform maintenance?<br />
• Operator<br />
Work designated with the sign “Operator”<br />
may only be carried out by persons<br />
who have been instructed in the safe<br />
operation and maintenance on the high<br />
pressure plant.<br />
Maintenance contract<br />
In order to guarantee a reliable operation og<br />
the equipment, we success, you signed a<br />
maintenance agreement. Please refer to<br />
you local Kärcher service department.<br />
32 English