Start up<br />

Electric drive<br />

Danger<br />

Risk of fatal injuries on account of electric<br />

voltage! Required electrical work must only<br />

be performed by an electrical specialist.<br />

– The socket must be secured through a<br />

wrong current protection switch with a<br />

triggering current of 30 mA.<br />

– This socket must be located close to the<br />

work station so that the plug can be<br />

pulled immediately in case of an emergency.<br />

– With a fixed power connection, a lockable<br />

main switch must be installed to<br />

completely separate it from the power<br />

supply.<br />

Electric drive 42 V and 400 V:<br />

Connect cable (4-core) to the threephase<br />

motor.<br />

Connect the motor cable on the power<br />

supply via a lockable main switch.<br />

Turn cleaning head on and check its rotation<br />

direction.<br />

The cleaning head must turn in the following<br />

direction when operated:<br />

Compressed air drive<br />

Warning<br />

In order to avoid damage to the compressed<br />

air drive by condensation wear and<br />

lack of lubrication, install a maintenance<br />

unit into the compressed air supply (order<br />

no. 6.610-020).<br />

This maintenance unit must be laid out as<br />

follows:<br />

– Air throughput of 500 l/min<br />

– Pressures up to 0.7 MPa<br />

The maintenance unit consists of:<br />

– Water separator<br />

– Pressure regulator with manometer<br />

– Proportional oiler<br />

Fill the proportional oiler with suitable lubrication<br />

oil by unscrewing the reservoir<br />

and filling it with lubricating oil (for oil<br />

type see "Care and Maintenance“).<br />

Connect compressed air hoses to the<br />

compressed air motor<br />

Note<br />

If the silencers are too small, the created<br />

backpressure of the exhaust air will cause<br />

an unstable run of the compressed air drive.<br />

Connect hoses to the exhaust air openings.<br />

Connect an air supply hose to connection<br />

no. 2.<br />

– Hose size for supply air: DN 6<br />

Connect exhaust air hoses to connection<br />

no. 1 and EXH.<br />

– Hose length: 1 -2 m<br />

– Hose size for exhaust air: DN 6<br />

Operation<br />

Danger<br />

Risk of injury on account of the escaping<br />

water jet that could be hot!<br />

– Only use the interior cleaner in closed<br />

containers.<br />

– Only insert the interior cleaner into a<br />

container or switch it into another container<br />

while the separate high pressure<br />

pump and internal drive are turned off.<br />

Place interior cleaner on top of container<br />

and secure if necessary.<br />

Connect the high pressure pump to the<br />

interior cleaner via a high pressure<br />

hose.<br />

Interior cleaners with electric drives:<br />

Switch on power supply.<br />

Interior cleaners with compressed air<br />

drives: Open the compressed air supply.<br />

Open the cleaning liquid supply.<br />

Switch on the separate high pressure<br />

pump.<br />

Shutting down<br />

Note<br />

Flush/rinse the interior cleaner for 30 seconds<br />

prior to shutting it off. This will avoid<br />

crusting and adhesion and thus a premature<br />

wear of the seals.<br />

Switch off the separate high pressure<br />

pump.<br />

Shut off the cleaning liquid supply.<br />

Interior cleaners with electric drives:<br />

Pull the power cord or shut off power<br />

supply.<br />

Interior cleaners with compressed air<br />

drives: Shut off the compressed air supply.<br />

Remove the interior cleaner from the<br />

container.<br />

Maintenance and care<br />

The basis for a safe operational plant is regular<br />

maintenance.<br />

Use only original parts of the manufacturer<br />

or part suggessted by him, such as<br />

– replacement and wear parts<br />

– Accessory parts<br />

– Fuel<br />

– Detergent<br />

Danger<br />

Risk of accident while working on the unit!<br />

During all tasks:<br />

Remove voltage from and secure high<br />

pressure pump at the main switch.<br />

Shut off the cleaning liquid supply.<br />

Interior cleaners with electric drives:<br />

Pull the power cord or shut off power<br />

supply.<br />

Interior cleaners with compressed air<br />

drives: Shut off the compressed air supply.<br />

Who may perform maintenance?<br />

• Operator<br />

Work designated with the sign “Operator”<br />

may only be carried out by persons<br />

who have been instructed in the safe<br />

operation and maintenance on the high<br />

pressure plant.<br />

Maintenance contract<br />

In order to guarantee a reliable operation og<br />

the equipment, we success, you signed a<br />

maintenance agreement. Please refer to<br />

you local Kärcher service department.<br />