Funzione Note Accessor. Mod. Precis. F.S. Function Notes<br />

Amperometro CC da<br />

shunt 0…60 mVcc<br />

ASH006<br />

ASH010<br />

ASH020<br />

ASH025<br />

ASH060<br />

ASH100<br />

9435 0.2%<br />

DC Ammeter via shunt<br />

0…60 mVdc<br />

ASH151<br />

ASH250<br />

ASH400<br />

ASH600<br />

Amperometro CA<br />

0…199,99 mA<br />

9443 0.5%<br />

AC Ammeter<br />

0…199.99 mA<br />

Amperometro CA<br />

0…1,9999 A<br />

Amperometro CA 0…5<br />

Aca diretta o da TA<br />

Amperometro CA<br />

Trms 0…199,99 mA<br />

Amperometro CA<br />

Trms 0…1,9999 A<br />

Amperometro CA<br />

Trms 0…5 A diretta o<br />

da TA<br />

Termometro PT100<br />

con 3 scale:<br />

-100,00…+199,99 °C<br />

-100,0…+650,0 °C<br />

-328,0…+1562,0 °F<br />

Ohmmetro con 4<br />

scale:<br />

0...199,99 Ω<br />

0…1,9999 kΩ<br />

0…19,999 kΩ<br />

0…199,99 kΩ<br />

Segnali da potenziometro<br />

con valore<br />

nominale compreso<br />

tra 0,5…50 kΩ<br />

Segnali da celle di carico<br />

da 0,5...3,5 mV/V<br />

Frequenzimetro /<br />

Tachimetro<br />

Vero valore efficace,<br />

per misure di corrente<br />

su segnali non perfettamente<br />

sinusoidali<br />

Misura della temperatura<br />

tramite sonde<br />

PT100 a 3 fili<br />

Misura della resistenza<br />

con sistema a 4 fili<br />

Misure tramite potenziometro<br />

a 3 fili<br />

Alimentazione cella<br />

10 V ±4% 35 mA<br />

Misura della frequenza<br />

di rete o numero di giri<br />

tramite pick-up, proximity,<br />

sonde ottiche,<br />

e sensori NPN/PNP.<br />

Dispone di alimentatore<br />

per sensori 5 V (15<br />

V opzionale)<br />

ATA020<br />

ATA025<br />

ATA050<br />

ATA150<br />

ATB050<br />

ATB100<br />

ATB150<br />

ATB250<br />

ATR202<br />

ATR204<br />

ATRLM1<br />

AV0156<br />

AV0157<br />

AV0162<br />

9444 0.5%<br />

9445 0.5%<br />

9447 ± 0.5 % F=<br />

20...2000 Hz<br />

9448 (Sin.)<br />

± 1 % DC+AC<br />

Crest Factor<br />

9449 ≤ 6<br />

9468 0.5%<br />

9470 0.2%<br />

9482 0.1%<br />

9484 0.1%<br />

9485 0.2%<br />

AC Ammeter<br />

0…1.9999 A<br />

AC Ammeter<br />

0…5 A or via C.T.<br />

AC Trms Ammeter<br />

0…199.99 mA<br />

AC Trms Ammeter<br />

0…1.9999 A<br />

AC Trms Ammeter<br />

0…5 A or via C.T.<br />

Pt100 Thermometer<br />

-100,00…+199,99 °C<br />

-100.0…+650.0 °C<br />

-328.0…+1562.0 °F<br />

Ohmmeter<br />

0...199,99 Ω<br />

0…1,9999 kΩ<br />

0…19,999 kΩ<br />

0…199,99 kΩ<br />

Signals from potentiometer<br />

with nominal<br />

value in range 0.5...50 kΩ<br />

Signals from load-cells<br />

with value in range<br />

0.5…3.5 mV/v<br />

Frequency meter /<br />

tachometer<br />

True RMS, useful for<br />

measuring current of<br />

imperfect-sinusoidal<br />

signals<br />

Temperature measure<br />

via 3-wire PT100<br />

sensors<br />

Resistance measure via<br />

4-wire system<br />

Measurement via<br />

3-wire potentiometer<br />

Cell power supply 10 V<br />

±4% 35 mA<br />

Measures mains line<br />

frequency or rpm’s via<br />

pick-ups, proximity<br />

sensors, optical and<br />

NPN/PNP sensors.<br />

It can power 5 V sensors<br />

(15 V optional)<br />

Continua nella pagina successiva...<br />

Continues on following page...<br />

www.binding.it 23