Varia 1V H 2O 1Vh H 2O Varia 1V H 2O XL 1Vh H 2O XL Varia 1V H 2O-4S XXL 1Vh H 2O-4S XXL Varia 2Lh H 2 O 2Rh H 2 O Nova E H 2 O Nova F - Air Renova A H 2 O Renova B - Air Mini M1 G2 Mini M1 G3 Rated heat output kW (closed operation) 11,0/ 5,5 (water side) 14,4/ 10,0 (water side) 21,2/ 15,6 (water side) 14,7/ 8,4 (water side) 14,0/ 9,0 (water side) 10,1 13,4/ 6,9 (water side) 8,8 2,8 3,0 Heat output range kW 7,7–14,3 10,1–18,7 14,8–22,0 10,3–19,1 9,8–18,2 7,1–13,1 9,4–17,4 6,2–11,4 – – Degree of efficiency % 82,2 81,3 85,9 81,9 89,6 89,0 89,3 > 88,0 79,8 79,8 Rec. chimney diameter (for min. height 5 m D/mm) 180 200 200 200 180 180 180 180 150 150 Flue gas dome diameter mm 180 200 200 200 180 180 180 180 150 150 Weight kg (approx.) 230/260 300/330 300/330 380/380 290 190 200 140 170 195 Req. min. cross section for supply and circulation air (with WAC cm 2 ) – – – – – – – – – – Req. min. cross section for supply and circulation air (with cm 2 ) 320/390 350/420 350/410 150/170 370/450 1580/1900 690/830 1420/1700 – – Operation for open combustion chamber DIN EN 13229 A Flue gas mass flow g/s – – – – – – – – – – Flue gas temperature °C – – – – – – – – – – Req. supply pressure (mbar) – – – – – – – – – – Rec. diameter for chamber volume compensation (cm) – – – – – – – – – – Operation for closed combustion chamber DIN EN 13229 A1 Flue gas mass flow g/s 9,6 15,2 18,9 12,2 12,7 9,5 12,8 9,4 6,8 6,8 Flue gas temperature °C 280 207 171 265 340 355 396 357 255 214 Req. supply pressure (Pa) 12 12 12 12 12 12 12 12 10 10 CO 2 % 9,6 7,8 8,6 8,2 8,2 8,1 7,7 7 6 6 Req. diameter as per German Sample Combustion Ordinance (cm) 15 15 15 15 15 15 15 15 12,5 12,5 Req. combustion air (m 3 /h) 34,2 55,2 69,6 45 46,3 34,1 47,3 34,7 14,2 15,2 Tests and values Type A – – – – – – – – – – Type A1 yes yes yes yes yes yes yes yes yes yes German Federal Immission Control Act phase 1 yes yes yes yes yes yes yes yes yes yes German Federal Immission Control Act phase 2 yes yes – yes yes yes yes yes yes yes Austrian Directive BVG 15a yes yes – yes yes yes yes yes yes yes * Ancillary heating surface GB 22
GB Mini M1 G4 Mini M1 GL/GL 45 Mini M1 GR/GR 45 Mini M2 G2 Mini M2 G3 Mini M2 G4 Mini M2 GL/GL 45 Mini M2 GR/GR 45 3,2 3,3 3,3 4,1 4,7 5,1 5,3 5,3 – – – – – – – – 79,8 79,8 79,8 82,9 82,9 82,9 82,9 82,9 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 220 160/160 170/170 230 270 310 215/215 225/225 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 6,8 6,8 6,8 10,1 10,1 10,1 10,1 10,1 182 167 167 339 285 246 223 223 9 10 10 10 10 9 10 10 6 6 6 7,7 7,7 7,7 7,7 7,7 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 16,2 16,7 16,7 15,6 17,9 19,4 20,2 20,2 – – – – – – – – yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes Subject to modification and errors without notice GB 23