Notice d'utilisation foyers vitrés - Flamespace
Notice d'utilisation foyers vitrés - Flamespace
Notice d'utilisation foyers vitrés - Flamespace
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
GB<br />
10. TECHNICAL DATA FOR<br />
FIREPLACE INSERT<br />
Mini<br />
R1V/<br />
R1Vh<br />
Mini Z1<br />
Mini<br />
Z1NSHF<br />
Mini<br />
S/Sh<br />
Speedy<br />
1V/1Vh<br />
Speedy<br />
1V NSHF*/<br />
1Vh NSHF*<br />
Varia<br />
1V/<br />
1Vh<br />
Varia<br />
Sh/SRh<br />
Varia<br />
Ah<br />
Rated heat output kW (closed operation) 6,0 7,0 10,0 7,0 9,0 10,0 11,0 11,0 11,0<br />
Heat output range kW 4,5–7,8 4,9–9,1 7,0–13,0 4,9–9,1 6,3–11,7 7,0–13,0 7,7–14,3 7,7–14,3 7,7–14,3<br />
Degree of efficiency % 84,1 78,1 87,3 78,1 78,0 82,0 78,3 80,0/78,6 80,4<br />
Rec. chimney diameter (for min. height 5 m D/mm) 160 180 180 180 200 200 200 200 200<br />
Flue gas dome diameter mm 160 180 180 180 200 200 200 200 200<br />
Weight kg (approx.) 150/150 160 160 205/205 200/270 200/270 245/260 270/280 300<br />
Req. min. cross section for supply and circulation air (with WAC cm 2 ) 700 700 – 700 700 – 700 700 700<br />
Req. min. cross section for supply and circulation air (with cm 2 ) 750/890 920/1100 1360/1640 810/970 1150/1390 1280/1540 1420/1710 1270/1530 1410/1690<br />
Operation for open combustion chamber DIN EN 13229 A<br />
Flue gas mass flow g/s 13,1 20,9 – 17,8 26,4 – 43,1 –/22,1 48,1<br />
Flue gas temperature °C 210 240 – 230 257 – 236 270 168<br />
Req. supply pressure (mbar) 10 12 – 12 12 – 8 –/10 10<br />
Rec. diameter for chamber volume compensation (cm) 40 40 – 45 50 – 47 –/55 49<br />
Operation for closed combustion chamber DIN EN 13229 A1<br />
Flue gas mass flow g/s 5,4 7,5 7,6 8,8 9,2 10,7 10 11/10 9,3<br />
Flue gas temperature °C 270 330 240 290 336 233<br />
(430 at neck)<br />
355 330 330<br />
(470 at neck)<br />
Req. supply pressure (Pa) 14 14 14 14 12 12 11 12 12<br />
CO 2<br />
% 10,6 8,6 11,1 7,9 9,2 7,5 9,5 10,1/9,6 10,2<br />
Req. diameter as per German Sample Combustion Ordinance (cm) 15 15 15 15 15 15 15 15 15<br />
Req. combustion air (m 3 /h) 16,4 25,5 25,2 27,6 30,6 34 36,1 33,1/35,6 32,8<br />
Tests and values<br />
Type A yes yes – yes yes – yes –/yes yes<br />
Type A1 yes yes yes yes yes yes yes yes/yes yes<br />
German Federal Immission Control Act phase 1 yes yes yes yes yes yes yes yes/yes yes<br />
German Federal Immission Control Act phase 2 yes/– yes yes yes yes yes yes yes/– –<br />
Austrian Directive BVG 15a yes yes yes yes yes yes yes yes/yes yes<br />
Subject to modification and errors without notice<br />
GB 17