Modifying the discharge settings<br />
Discharging the battery<br />
ENGLISH<br />
Follow this procedure to modify the discharge settings from the main screen, use the + or -<br />
keys to select discharge mode from the main screen (indicated by “DISCHARGE”).<br />
The charger will display the default settings for the<br />
selected type of battery.<br />
After you have selected the right parameters to discharge<br />
your battery, press and hold the ENTER key. The battery<br />
check will be displayed.<br />
If the battery is properly connected and functional the<br />
discharge screen will be displayed.<br />
ENGLISH<br />
You can change the settings if required:<br />
1. Press the ENTER key, the discharge current selection will blink, use the + or - keys to select a<br />
different discharge current (0.1A to 10A, 80W maximum).<br />
2. Press the ENTER key, the discharge cut-off voltage selection will blink, use the + or - keys to select<br />
a different cut-off voltage. The limit is 0.7V for NiCd/NiMH, 2.8V/cell for LiPo and 2.5V/cell for LiFe.<br />
The charger will discharge the batteries down to cutoff value.<br />
With LiPo and LiFe batteries, if the battery voltage is over the cutoff limit, the charger will balance<br />
the cells (if required and balancing mode is switched on) and then discharge the battery down to the<br />
cutoff limit. When balancing, the screen will display the „LIPO BALANCE“ message.<br />
After discharge It is recommended to recharge LiPo and LiFe batteries as they can be damaged if<br />
stored empty.<br />
Note: Changing the default cut-off voltage setting to a lower value can damage the battery. Only<br />
modify this setting if you are an experienced user.<br />
Note: Depending on the conditions of use, the charger thermal protection might activate so that the<br />
charger can cool down. After a brief interruption the discharge will resume and continue normally.<br />