05.08.2013 Views

Indice - Giornale Italiano di Medicina del Lavoro ed Ergonomia ...

Indice - Giornale Italiano di Medicina del Lavoro ed Ergonomia ...

Indice - Giornale Italiano di Medicina del Lavoro ed Ergonomia ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

G Ital M<strong>ed</strong> Lav Erg 2006; 28:3, Suppl 35<br />

www.gimle.fsm.it<br />

ste osservazioni mostrano che l’esposizione ad alte concentrazioni <strong>di</strong> persolfato<br />

d’ammonio, riduce l’efficienza <strong>del</strong> controllo nervoso NANC-i<br />

<strong>del</strong>le vie aeree <strong>di</strong> cavia.<br />

DISCUSSIONE<br />

Il trattamento <strong>di</strong> cavie con un aereosol <strong>di</strong> persolfato d’ammonio, un<br />

agente asmogeno professionale (1), ad una concentrazione 10 volte superiore<br />

al proprio TLV-TWA, ha permesso <strong>di</strong> evidenziare una significativa<br />

riduzione <strong>del</strong>la risposta NANC-i tracheale.<br />

Ciò suggerisce che uno degli effetti <strong>del</strong> persolfato d’ammonio è probabilmente<br />

correlato a una ridotta funzionalità <strong>del</strong>l’innervazione inibitoria<br />

intrinseca, con conseguente ridotta liberazione dei neurotrasmettitori<br />

in essa contenuti (14), e/o una più veloce degradazione degli stessi. L’aver<br />

osservato la riduzione <strong>del</strong>le risposte NANC-i in assenza <strong>del</strong>l’epitelio,<br />

notoriamente bersaglio primario <strong>del</strong> danno prodotto soprattutto da agenti<br />

asmogeni irritanti, permette <strong>di</strong> escludere che gli effetti osservati siano riferibili<br />

a danno epiteliale. Pertanto, una ridotta efficienza <strong>del</strong>l’innervazione<br />

intrinseca inibitoria, che coopera al mantenimento <strong>del</strong>la pervietà<br />

<strong>del</strong>le vie aeree, può parzialmente spiegare l’insorgenza <strong>di</strong> iperreattività<br />

bronchiale in questa forma <strong>di</strong> asma professionale.<br />

Finora si è ritenuto che i meccanismi responsabili <strong>del</strong>l’iperreattività<br />

bronchiale indotta da persolfati includessero meccanismi immunome<strong>di</strong>ati<br />

umorali (con la partecipazione <strong>del</strong>le IgE non ancora definita) (1, 15) e/o<br />

cellulari (che coinvolgono la partecipazione <strong>di</strong> mastociti) (16) e meccanismi<br />

<strong>di</strong>retti <strong>di</strong> irritazione/danno <strong>del</strong>la mucosa bronchiale. I nostri dati in<strong>di</strong>cano<br />

che una riduzione <strong>del</strong>la funzionalità <strong>del</strong>l’innervazione NANC-i<br />

può rappresentare una nuova ipotesi patogenetica, che meriterebbe <strong>di</strong> essere<br />

stu<strong>di</strong>ata anche nelle forme <strong>di</strong> asma professionale sostenute da agenti<br />

con duplice azione irritante e sensibilizzante, nonché nelle forme, senza<br />

periodo <strong>di</strong> latenza, causate da agenti irritanti.<br />

BIBLIOGRAFIA<br />

1) Moscato G, Pignatti P, Yacoub MR, Romano C, Spezia S, Perfetti L.<br />

Occupational asthma and occupational rhinitis in hairdressers. Chest<br />

2005; 128: 3590-3598.<br />

2) Ameille J, Pauli G, Calastreng-Crinquand A, Vervloet D, Iwatsubo Y,<br />

Popin E, Bayeux-Dunglas MC, Kopferschmitt-Kubler MC; Observatoire<br />

National des Asthmes Professionnels. Report<strong>ed</strong> incidence of occupational<br />

asthma in France, 1996-99: the ONAP programme. Occup<br />

Environ M<strong>ed</strong> 2003; 60: 136-141.<br />

3) Mensing T, Marek W, Baur X. The influence of ammonium persulfate<br />

on guinea pig tracheal muscle tone: release of nitric oxide. Pharmacol<br />

Toxicol 1996; 78: 336-340.<br />

4) Barnes PJ. Neurogenic inflammation and asthma. J Asthma 1992;<br />

29: 165-180.<br />

5) Barnes PJ. Neurogenic inflammation in the airways. Int Arch Allergy<br />

Appl Immunol 1991; 94: 303-309.<br />

6) Lundberg JM, Lundblad L, Saria A, Angaard A. Inhibition of cigarette<br />

smoke-induc<strong>ed</strong> o<strong>ed</strong>ema in the nasal mucosa by capsaicin pretreatment<br />

and substance P antagonist. Naunyn Schmi<strong>ed</strong>ebergs Arch<br />

Pharmacol 1984; 326: 181-185.<br />

7) Lundberg JM, Saria A, Lundberg L et al. Bioactive peptides in capsaicin-sensitive<br />

C-fiber afferents of the airways: functional and<br />

pathophysiological implications. In: The airways: neural control in<br />

health and <strong>di</strong>sease, Kaliner MA, Barnes PJ <strong>ed</strong>s. New York, Marcel<br />

Dekker, 1987, pp. 417-445.<br />

8) Lundblad L. Protective reflexes and vascular effects in the nasal mucosa<br />

elicit<strong>ed</strong> by activation of capsaicin-sensitive substance P-immunoreactive<br />

trigeminal neurons. Acta Physiol Scand 1984; 529: S1-S42.<br />

9) Barnes PJ. Neuroeffector mechanisms: the interface between inflammation<br />

and neuronal responses. J Allergy Clin Immunol 1996; 98:<br />

S73-S81.<br />

10) Barnes PJ, Liew FY. Nitric oxide and asthmatic inflammation. Immunol<br />

Today 1995; 16: 128-130.<br />

11) Barnes PJ. Nitric oxide and asthma. Res Immunol 1995; 146: 698-702.<br />

12) Car<strong>del</strong>l LO, Uddman R, Edvinsson L. Low plasma concentration of<br />

VIP and elevat<strong>ed</strong> levels of other neuropeptides during exacerbations<br />

of asthma. Eur Respir J 1994; 7: 2169-2173.<br />

13) D’Agostino G, Chiari MC, Grana E, Subissi A, Kilbinger H. Muscarinic<br />

inhibition of acetylcholine release from a novel in vitro preparation<br />

of the guinea-pig trachea. Naunyn Schmi<strong>ed</strong>ebergs Arch Pharmacol<br />

1990; 342: 141-145.<br />

14) Dellabianca A, Sacchi M, Agazzi A, Di Nucci A, Anselmi L, Tonini<br />

M, Candura SM. Neurotransmitters in the airways: pharmacological<br />

characterization of the non-adrenergic non-cholinergic inhibitory system<br />

in guinea-pig trachea. G Ital M<strong>ed</strong> Lav Erg 2004; 26 (4 Suppl):<br />

50-51.<br />

15) Munoz X, Cruz MJ, Orriols R, Bravo C, Espuga M, Morell F. Occupational<br />

asthma due to persulfate salts: <strong>di</strong>agnosis and follow-up.<br />

Chest 2003; 123: 2124-2129.<br />

16) Blainey AD, Ollier S, Cun<strong>del</strong>l D, Smith RE, Davies RJ. Occupational<br />

asthma in a hairdressing salon. Thorax 1986; 41: 42-50.<br />

P-21<br />

UN’ESPERIENZA DI MONITORAGGIO AMBIENTALE DI FIBRE<br />

MINERALI ARTIFICIALI IN OPERAZIONI DI MANUTENZIONE<br />

DI CARROZZE FERROVIARIE<br />

M.G. Putzu1 , C. Causarano2 , C. Orria2 , B. Margaira2 , C. Romano1 1 Dipartimento <strong>di</strong> Traumatologia, ortope<strong>di</strong>a e Me<strong>di</strong>cina <strong>del</strong> <strong>Lavoro</strong>,<br />

Università degli stu<strong>di</strong> <strong>di</strong> Torino<br />

2 Unità Sanitaria Territoriale <strong>di</strong> Torino Direzione Sanità Rete<br />

Ferroviaria Italiana<br />

Corrispondenza: Dr. Carmelo Causarano - Unità Sanitaria Territoriale<br />

<strong>di</strong> Torino Direzione Sanità Rete Ferroviaria Italiana - Tel. 011-6652380,<br />

E-mail: c.causarano@rfi.it<br />

AN EXPERIENCE OF ENVIRONMENTAL MONITORING<br />

OF ARTIFICIAL MINERAL FIBERS IN ACTIVITIES<br />

OF MAINTENANCE OF RAILWAY WAGONS<br />

Key words: MMF (Man Made Mineral Fibres), ceramic fibres, rolling<br />

stok, environmental exposure at work.<br />

ABSTRACT. The environmental monitoring of maintenance on railway<br />

carriages insulat<strong>ed</strong> with man-made mineral fibres show<strong>ed</strong> very low<br />

fibre concentrations. The concentrations measur<strong>ed</strong> overlap the limits<br />

establish<strong>ed</strong> for non professional environments by the Recommendation<br />

of The Ministry of Health (20/12/1991). Moreover, no ceramic fibres,<br />

which are suspect<strong>ed</strong> carcinogens to man, were found. Further long-term<br />

monitoring will be carri<strong>ed</strong> out in order to ensure that fibre<br />

concentrations remain within this range.<br />

INTRODUZIONE<br />

Il problema <strong>del</strong>la tutela <strong>del</strong>la salute dei lavoratori nel senso più ampio<br />

<strong>del</strong> termine e l’esigenza <strong>di</strong> garantire le migliori con<strong>di</strong>zioni lavorative<br />

possibili hanno indotto a porre una speciale attenzione alle fibre minerali<br />

artificiali usate come sostitutive <strong>del</strong>l’asbesto. Per tale motivo sono state<br />

monitorate le lavorazioni <strong>di</strong> una officina <strong>di</strong> manutenzione <strong>di</strong> rotabili ferroviari<br />

in presenza <strong>di</strong> coibentazioni con fibre minerali artificiali al fine <strong>di</strong><br />

valutare l’eventuale aero<strong>di</strong>spersione e la concentrazione <strong>del</strong>le m<strong>ed</strong>esime.<br />

Di maggior interesse sono le fibre ceramiche, che sono considerate un<br />

possibile cancerogeno per l’uomo (1), ma proprio nell’ottica <strong>del</strong>la maggiore<br />

tutela possibile dei lavoratori si è valutata attentamente anche la<br />

presenza <strong>di</strong> lane minerali e fibre vetrose. Le lavorazioni sottoriportate<br />

non avrebbero dovuto esporre i lavoratori alla presenza <strong>di</strong> fibre ceramiche,<br />

in quanto secondo un’analisi attenta non sarebbero state in situ; esse<br />

sono tuttavia state accuratamente ricercate nell’aero<strong>di</strong>sperso.<br />

MATERIALI E METODI<br />

Sono stati effettuati campionamenti ambientali volti a valutare l’eventuale<br />

aero<strong>di</strong>spersione <strong>di</strong> fibre legata alle modalità operative <strong>del</strong>le attività<br />

<strong>di</strong> manutenzione sulle carrozze che presentano materiale coibentante<br />

costituito da fibre minerali artificiali non ermeticamente imbustate o con<br />

imbustatura deteriorata.<br />

Le lavorazioni monitorate sono state le seguenti:<br />

1. controllo visivo, prove funzionali e piccole lubrificazioni senza intervento<br />

riparativo (controlli eseguiti nel capannone in manutenzione<br />

corrente programmata a treno completo);<br />

2. sostituzione <strong>di</strong> un pistone pneumatico <strong>di</strong> comando porta <strong>di</strong> salita (lavorazione<br />

staticamente confinata con vettura in officina);

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!